  • IPEN-DOC 19817

    MOURA, E.S.; ZEITUNI, C.A. ; SAKURABA, R.K.; GONCALVES, V.D.; CRUZ, J.C.; JUNIOR, D.K.; SOUZA, C.D.; ROSTELATO, M.E.C.M. . Absorbed dose simulations in near-surface regions using high dose rate iridium-192 sources applied for brachytherapy. Radiation Physics and Chemistry, v. 95, p. 299-301, 2014.

    Palavras-Chave: absorbed radiation doses; beta particles; brachytherapy; cobalt 60; computerized simulation; depth dose distributions; iridium 192; mammary glands; monte carlo method; pmma; prostate; surfaces

  • IPEN-DOC 21630

    CARVALHO, DIEGO V. de ; HAMADA, MARGARIDA M. . Análise de um Fantom multifásico usando tomógrafo industrial computadorizado de terceira geração desenvolvido no IPEN. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 17.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 8.; PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO DESENVOLVIMENTO TECNOLÓGICO E INOVAÇÃO, 1., 17-18 de novembro, 2011, São Paulo, SP. Resumo expandido... 2011. p. 135-136.

    Palavras-Chave: phantoms; computerized tomography; pmma; testing; industry

  • IPEN-DOC 25736

    FONTES, LADYJANE P. ; CORREA, EDUARDO L. ; POTIENS, MARIA da P.A. . Application of a Tandem system for HVL evaluation in computed tomography. Radiation Physics and Chemistry, v. 155, p. 62-64, 2019. DOI: 10.1016/j.radphyschem.2018.08.023

    Abstract: Computed tomography (CT) is a method of imaging used for the diagnosis and treatment of diseases. Different from the conventional diagnostic radiology equipment, where the test for the determination of the half value layer (HVL) is recommended, in CT equipment due to its geometry, the determination of the HVL is a difficult task and is usually only provided by the manufacturer. The effective energy of a beam is determined by definition, by means of HVL determination. When HVL values are not easily determined, as in the case of CT, it is possible to evaluate the effective energy of the beam through a system consisting of the use of different energy dependent dosimeters, where the ratio between the calibration curve responses in energy can provide the effective energy of the beam (Tandem system). The system used in this work for the evaluation of HVL in computed tomography is composed of groups formed by an ionization chamber of the pencil-type and cylindrical absorber layers of aluminum and Polymethyl methacrylate (PMMA).

    Palavras-Chave: tomography; computerized tomography; radiations; radiation chemistry; ionization chambers; pmma

  • IPEN-DOC 24057

    FONTES, LADYJANE P. ; POTIENS, MARIA da P.A. . Application of the correction factor for radiation quality Kq in dosimetry with pencil-type ionization chambers using a tandem system. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The pencil-type ionization chamber widely used in computed tomography (CT) dosimetry, is a measuring instrument that has a cylindrical shape and provides uniform response independent of the angle of incidence of ionizing radiation. Calibration and measurements performed with the pencil-type ionization chamber are done in terms of Kerma product in air-length (Pk,l) and values are given in Gy.cm. To obtain the values of (Pk,l) during clinical measurements, the readings performed with the ionization chamber are multiplied by the calibration coefficient (Nk,l) and the correction factor C for quality (Kq) which are given in Calibration certificates of the chambers. The application of the correction factor for radiation quality Kq is done as a function of the effective energy of the beam that is determined by the Half Value layer (HVL) calculation. In order to estimate the HVL values in this work, a Tandem system made up of cylindrical aluminum and PMMA absorber layers was used as a low cost and easy to apply method. From the Tandem curve, it was possible to construct the calibration curve and obtain the appropriate Kq to the beam of the computed tomography equipment studied.

    Palavras-Chave: calibration; computerized tomography; corrections; dosimetry; ionization chambers; kerma; layers; pmma; quality assurance

  • IPEN-DOC 17494

    ROCHA, FELICIA DEL G.; CAMPOS, VICENTE de P. de ; CAMPOS, LETICIA L. . Assessment of CaSOsub(4):Dy thermoluminescent detectors response for different phantom materials and proton energies. In: CONGRESSO BRASILEIRO DE METROLOGIA, 6., 27-30 de setembro, 2011, Natal, RN. Anais... 2011.

    Palavras-Chave: calcium sulfates; dysprosium; thermoluminescent dosemeters; radiotherapy; phantoms; tissue-equivalent materials; energy dependence; pmma; photons

  • IPEN-DOC 23121

    VENEZIANI, G.R. ; CORREA, E.L. ; POTIENS, M.P.A. ; CAMPOS, L.L. . Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams. Journal of Physics: Conference Series, v. 733, p. 1-6, 2016. DOI: 10.1088/1742-6596/733/1/012088

    Abstract: IAEA code of practice TRS-457 states that standard phantoms should offer the same primary attenuation and scatter production as relevant body section of a representative patient. Material cost, availability and dimensional stability must also be considered. The goal of this study is to determine the attenuation coefficient of printed ABS and PLA samples in standard X-ray beams, verifying if phantoms printed with these materials could be an easier-handle substitute for PMMA, enabling the creation of different designs in an easier and cheaper way. Results show that PMMA presents higher attenuation coefficient, followed by PLA and ABS, which means that thinner PMMA layer creates higher radiation attenuation.

    Palavras-Chave: attenuation; availability; design; layers; patients; phantoms; pmma; radiology; stability; standards; x radiation

  • IPEN-DOC 28658

    OLIVEIRA, M.V.L.; SAVI, M. ; ANDRADE, M.A.B.; VILLANI, D. ; POTIENS, M.P.A. ; BRANCO, H.S.; UBEDA, C.; MDLETSHE, S.. Attenuation properties of common 3D printed FFF plastics for mammographic applications. Brazilian Journal of Radiation Sciences, v. 10, n. 1, p. 1-17, 2022. DOI: 10.15392/bjrs.v10i1.1732

    Abstract: The aim of this study was to evaluate the feasibility of using acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) 3D printing filaments as materials for mammography phantom construction, comparing their attenuation properties at two different set-ups: at a Calibration Laboratory and directly to a mammography unit. The attenuation of 3D printed test phantoms of two types of common 3D printing Fused Filament Fabrication (FFF) filaments (ABS and PLA) were characterized in comparison with polymethylmethacrylate (PMMA). The measurements were carried out with standard IEC 61267 X-rays, using RQR 2-M and RQR 4-M beam qualities at the Instruments Calibration Laboratory, and then applied to a mammography unit, with measurements with 28 kV and 35 kV. Attenuation characteristics evaluated indicate the suitable equivalence of PLA to PMMA for 3D printing breast complex phantoms. The plastic materials used in this study suggest that the FFF technique may be suitable for mammography phantom development.

    Palavras-Chave: 3d printing; acrylonitrile; animal tissues; attenuation; butadiene; filaments; mammary glands; phantoms; pmma; styrene; x radiation

  • IPEN-DOC 11119

    SOUZA, W.B.; PARRA, D.F. ; LUGAO, A.B. . Avaliacao de propriedades mecanicas e termicas do composito de poli(metacrilato de metila) carregado com 'lama vermelha de bauxita'. In: CONGRESSO BRASILEIRO DE POLIMEROS, 8., 6-10 nov, 2005, Aguas de Lindoia, SP. Anais... 2005.

    Palavras-Chave: pmma; bauxite; mechanical properties; thermodynamic properties

  • IPEN-DOC 15329

    ALCANTARA, M.C.; SORDI, G.M.A.A.; CALDAS, L.V.E. ; FURQUIM, T.A.C.. Avaliacao dos criterios de qualidade de imagem, indice de rejeicao e estimativa de doses em um departamento de mamografia. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 14.; SIMPOSIO DE INSTRUMENTACAO E IMAGENS MEDICAS, 4., 10-12 de outubro, 2009, Sao Paulo, SP. Anais... 2009.

    Palavras-Chave: biomedical radiography; mammary glands; image processing; quality assurance; radiation doses; phantoms; pmma

  • IPEN-DOC 15745

    MATSUSHIMA, LUCIANA C.; VENEZIANI, GLAUCO R.; SAKURABA, ROBERTO K.; CRUZ, JOSE C. da; CAMPOS, LETICIA L. . Avaliacao dosimetrica do CaSOsub(4):Dy, LiF:Mg,Ti e microLiF:Mg, Ti na dosimetria de feixes clinicos de fotons (6 e 15 MV) utilizando simulador de PMMA. In: CONGRESSO DE FISICA APLICADA A MEDICINA, 29 de setembro - 2 de outubro, 2010, Botucatu, SP. Anais... 2010.

    Palavras-Chave: thermoluminescent dosemeters; calcium sulfates; doped materials; dysprosium; lithium fluorides; magnesium; titanium; photon beams; pmma

  • IPEN-DOC 24441

    OLIVEIRA, NATHALIA S.; SOUZA, SAMARA P.; FERREIRA, PAMELA Z.; DANTAS, NOELIO O.; SILVA, ANIELLE C.A.; NEVES, LUCIO P.; CALDAS, LINDA V.E. ; CARRERA, BETZABEL N.S.; WATANABE, SHIGUEO; PERINI, ANA P.. Avaliação das curvas de emissão termoluminescente de uma nova matriz vítrea / Evaluation of the glow curves of a new glass matrix. In: CONGRESSO BRASILEIRO DE METROLOGIA, 9.; CONGRESSO INTERNACIONAL DE METROLOGIA MECANICA, 4.; CONGRESSO INTERNACIONAL DE METROLOGIA ELETRICA, 12.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇOES IONIZANTES, 4.; WORKSHOP DA REDE DE METROLOGIA QUIMICA DO INMETRO, 3.; CONGRESSO BRASILEIRO DE METROLOGIA OPTICA, 2., 26-29 de novembro, 2017, Fortaleza, CE. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2017. p. 1-4.

    Abstract: Termoluminescência é uma técnica dosimétrica que pode ser aplicada para uso pessoal, clínico, ambiental e em doses altas. Neste trabalho foi estudada uma nova matriz vítrea, com composição nominal de 20Li2CO3.10Al2O3.25BaO.45B2O3 (mol%), pela técnica de termoluminescência. Para isto, foram analisadas as curvas de emissão termoluminescente, após a irradiação desta matriz vítrea com doses altas. Os resultados obtidos mostraram que esta nova matriz vítrea apresenta um pico na temperatura de 260°C, que é ideal para aplicações em dosimetria.

    Palavras-Chave: absorbed dose range; cobalt 60; dosimetry; glow curve; pmma; radiation doses; thermoluminescence; thermoluminescent dosemeters; glass

  • IPEN-DOC 28033

    SOUSA JUNIOR, ADERSON R. de . Avaliação de dose em radiologia diagnóstica pediátrica / Dose evaluation in pediatric diagnostic radiology . 2021. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 90 p. Orientador: Letícia Lucente Campos Rodrigues. DOI: 10.11606/D.85.2020.tde-15072021-163406

    Abstract: De acordo com o relatório do Conselho Nacional de Proteção Radiológica (NCRP, 2004), nos Estados Unidos foi registrado um aumento médio anual nas exposições médicas de 0,6 mSv/ano para 3 mSv/ano entre os anos de 1987 a 2006. No Brasil, vem crescendo a taxas próximas de 10% ao ano, e os exames de diagnóstico por imagem, segundo dados do DATASUS, tiveram acréscimo de 45,27% entre dezembro de 2000 a 2006 (SOARES, 2011). As crianças são mais sensíveis à exposição à radiação e por terem maior expectativa de vida, têm maior chance e risco de manifestar as consequências dessa exposição ao longo de suas vidas. "Este trabalho tem por objetivo geral a identificação e avaliação da dose entregue aos pacientes em radiografia médica, em exames de tórax pediátrico na faixa etária de um a cinco anos", conforme termos adotados pela ANVISA, Ministério da Saúde e OMS. Para isso, foi desenvolvido um objeto simulador de polimetilmetacrilato (PMMA), especialmente projetado para avaliação da dose de radiação em paciente pediátrico. Para as avaliações foram utilizados dosímetros termoluminescentes (TLD) de CaSO4:Dy (sulfato de cálcio dopado com disprósio), desenvolvido pelo Laboratório de Materiais Dosimétricos do IPEN/CNEN (FORNER, 2019), e seguidos os procedimentos do Comitê de Avaliação de Serviços de Ensaio e Calibração - CASEC (IRD, 2001). As exposições com raios X foram efetuadas em um Serviço Público Municipal de Pronto Atendimento (PA), situado no Município de Cotia, fora do IPEN, parceiro do trabalho.

    Palavras-Chave: pediatrics; children; diagnosis; radiotherapy; radiology; nuclear medicine; polyacrylates; pmma; radiation injuries; radiation detection; radiation detectors; thermoluminescent dosemeters; dosimetry; absorbed radiation doses; effective radiation doses; equivalent radiation doses; genetically significant dose; clinical trials; patients; occupational exposure; regional analysis

  • IPEN-DOC 11309

    CAVALCANTE, JONAS S. . Caracterizacao de copolimero reticulado, a base de acrilato e metacrilato obtido por fotopolimerizacao para aplicacao como guia de onda. 2005. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 73 p. Orientador: Jose Oscar Willian Vega Bustillos.

    Palavras-Chave: copolymers; cross-linking; pmma; polymerization; ultraviolet radiation; waveguides; optical fibers

  • IPEN-DOC 14456

    KAI, JIANG; PARRA, DUCLERC F. ; BRITO, HERMI F.. Caracterizacao e estudo fotoluminescente de filme bibolor de PMMA dopado com complexos de Eu(III) e Tb(III). In: REUNIAO ANUAL DA SOCIEDADE BRASILEIRA DE QUIMICA, 30., 31 de maio - 3 de junho, 2007, Aguas de Lindoia, SP. Resumo... 2007.

    Palavras-Chave: rare earths; ketones; photoluminescence; pmma; doped materials; europium; terbium

  • IPEN-DOC 14679

    KAI, J.; STEFANI, R.; FELINTO, M.C.F.C. ; BRITO, H.F.. Color tuning systems of polymer doped with rare earth complexes. In: INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS, 11th, September 20-25, 2009, Rio de Janeiro, RJ. Abstract... 2009.

    Abstract: Rare earth complexes were synthesized and doped into polymers resulting in luminescent films. The obtained systems were characterized with elemental analysis, IR, TGA/DTG and XRD techniques. Photoluminescence properties were investigated and processes of energy transfer and sensitization were studied. Monochromatic emissions of obtained polymeric systems enabled their potential applications in multicolor displays because of the primary colors emitted by TR3+: red (Sm3+ and Eu3+), blue (Gd3+) and green (Tb3+). The polymer matrix performs an essential role in the luminescent sensitization processes for systems containing Sm3+, Eu3+, Gd3+ and Tb3+, therefore the overall systems act as Light Conversion Molecular Devices (LCMDs).

    Palavras-Chave: rare earth complexes; synthesis; doped materials; pmma; polymers; films; luminescence; color; tuning

  • IPEN-DOC 20818

    BRAVIM, AMANDA ; SAKURABA, ROBERTO K. ; CRUZ, JOSE C. da; CAMPOS, LETICIA L. . Comparação da distribuição de dose obtida através do TLD-100 com a do sistema de planejamento eclipse 11.0 em radioterapia de arco modulado volumetrico (VMAT). In: CONGRESSO DE FISICA APLICADA A MEDICINA, 10., 24-27 de setembro, 2014, Botucatu, SP. Anais... 2014.

    Palavras-Chave: lithium fluorides; magnesium; titanium; nuclear medicine; phantoms; pmma; radiation doses; radiotherapy; thermoluminescent dosemeters

  • IPEN-DOC 18520

    BRAVIM, AMANDA; SAKURABA, ROBERTO K.; CRUZ, JOSE C. da; CAMPOS, LETICIA L. . Comparative study of different phantoms in 12 MeV clinical electron beam dosimetry. In: SYMPOSIUM ON RADIATION MEASUREMENTS AND APPLICATIONS, May 14-17, 2012, Oakland, USA. Proceedings... 2012.

    Palavras-Chave: lithium fluorides; magnesium; titanium; calcium sulfates; dysprosium; electron beams; thermoluminescent dosemeters; pmma; phantoms; patients; radiation doses; radiation protection; comparative evaluations

  • IPEN-DOC 13424

    GALANTE, A.M.S.; CAMPOS, L.L. . Comparative study of the dose rate influence in the radiochromic polymeric film dosimeter response. In: INTERNATIONAL CONFERENCE ON DEFECTS IN INSULATING MATERIALS, 16th, August 24-29, 2008, Aracaju, SE. Proceedings... 2008.

    Palavras-Chave: film dosimetry; polymers; pmma; polycarbonates; ionizing radiations; dose ratemeters; radiation effects

  • IPEN-DOC 28012

    GROPPO, DANIELA P. . Correlação de parâmetros físicos e dosimétricos de diferentes detectores utilizados em dosimetria de campos pequenos para radioterapia em um acelerador linear clínico / Correlation of physical and dosimetric parameters of different detectors used in small field dosimetry for radiotherapy in a clinical linear accelerator . 2020. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 135 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/T.85.2020.tde-16062021-145616

    Abstract: Atualmente, as doses administradas em procedimentos radiocirúrgicos são extremamente elevadas, quando comparadas a outros procedimentos radioterápicos. A acurácia dosimétrica para esses tipos de tratamentos requer um comissionamento de campos pequenos de radiação a serem parametrizados em um sistema de planejamento computadorizado. A medição dosimétrica (relativa e direta) de campos pequenos representa um desafio, pois pode introduzir erros na entrega de dose; assim, alguns parâmetros dosimétricos (perfil de dose e porcentagem de dose na profundidade) da interação da radiação com a matéria podem ser comprometidos como o equilíbrio de partículas carregadas. Para melhor mensurar esses dados dosimétricos, alguns detectores são empregados. Mesmo com o uso destes detectores específicos, faz-se necessário identificar e avaliar as incertezas que podem provir do efeito do tamanho do volume e do arranjo experimental do detector sob o campo de radiação. Neste trabalho, as medições dosimétricas foram obtidas com filmes radiocrômicos (medição de referência), câmaras de ionização de volume sensível pequeno, diodos e detectore de diamante. Para correlacionar os parâmetros físicos e dosimétricos obtidos com os detectores, foram utilizados formalismos matemáticos. Esses formalismos matemáticos propostos mostraram-se eficazes quando aplicados à dosimetria de campos pequenos circulares em aceleradores lineares clínicos da fabricante Elekta, modelo Versa HD®, com feixes de fótons (6 MV), com e sem o uso do filtro aplainador (flattening filter).

    Palavras-Chave: linear accelerators; rilac; linac-ring accelerators; quadrupole linacs; radiation detectors; small angle scattering; fractionated irradiation; surgical materials; filters; gamma sources; ionization chambers; dose rates; radiation doses distributions; radiation dose units; measuring methods; phantoms; pmma; computer-aided manufacturing; data covariances; three-dimensional calculations; mathematical solutions; clinical trials; dosimetry; radiotherapy; nuclear medicine

  • IPEN-DOC 15017

    ANTONIO, PATRICIA L.; OLIVEIRA, MERCIA L.; CALDAS, LINDA V.E. . Depth dose curves from sup(90)Sr+ sup(90)Y clinical applicators using the thermoluminescent technique. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: brachytherapy; calcium sulfates; calibration standards; depth dose distributions; diagrams; experimental data; eyes; phantoms; pmma; radiation doses; strontium 90; thermoluminescent dosemeters; thickness; yttrium 90

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.