Navegação por assunto "proton beams"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 15178

    OLIVEIRA, HENRIQUE B. de ; BRAZAO, NEI G. ; SCIANI, VALDIR . Analytical solutions for thermal transient profile in solid target irradiated with low energy and high beam current protons. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: analytical solution; beam currents; cyclone cyclotron; experimental data; gallium 67; heat transfer; isotope production; proton beams; protons; targets; temperature gradients; thallium 201; time dependence; transients

  • IPEN-DOC 21612

    ARAUJO, S.G. ; SCIANI, V. . Automated irradiation systems for use in cyclotrons. In: INTERNATIONAL SYMPOSIUM ON UTILIZATION OF ACCELERATORS, November 26-30, 2001, São Paulo, SP. Abstract... Vienna, Austria: International Atomic Energy Agency (IAEA), 2001. p. 28-29.

    Observação: Report Number IAEA-SM-366/106

    Abstract: The objective of this work was the development of irradiating systems completely automatized, always aiming to reduce the radiation exposition dose to the workers and to increase the reliability of use of these systems, because very high activities are expected in these processes.

    Palavras-Chave: automation; computerized control systems; cooling systems; cyclotrons; irradiation devices; mev range 10-100; proton beams; target chambers

  • IPEN-DOC 18891

    ROSSI, PEDRO C.R.; MAIORINO, JOSE R. . Benchmark on computer simulation of radioactive nuclides production rate in lead target exposed to 660 MeV protons. In: VANIN, VITO R. (Ed.) BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 33rd, September 7-11, 2010, Campos do Jordão, SP. Proceedings... American Institute of Physics, 2010. p. 369-375.

    Palavras-Chave: benchmarks; computerized simulation; coordinated research programs; irradiation; jinr cyclotrons; lead 206 target; lead 208 target; mev range; proton beams; proton reactions; protons; radioisotopes

  • IPEN-DOC 04908

    LIMA, W. . Ciclotron para producao industrial de radioisotopos - caracteristicas relevantes. In: 4th MEETING ON NUCLEAR APPLICATIONS, ENCONTRO NACIONAL DE APLICACOES NUCLEARES, August 18-22, 1997, Pocos de Caldas, MG. 1997. p. 1019-1022.

    Palavras-Chave: cyclotrons; isotope production; industry; targets; beam currents; magnetic fields; proton beams

  • IPEN-DOC 08358

    LION, LUCIANA F. de . Desenvolvimento de novo metodo de producao de sup(111)In a partir da irradiacao de Cd com protons. 2002. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 75 p. Orientador: Joao Alberto Osso Junior.

    Palavras-Chave: indium 111; isotope production; cyclotrons; proton beams; cadmium 112 target; radioisotopes; nuclear medicine

  • IPEN-DOC 07789

    MORAES, V.; OSSO JUNIOR, J.A. . Desenvolvimento de um metodo de preparacao de um tracador de estanho, o sup(117m)Sn, a partir da irradiacao de estanho natural com feixe de protons do ciclotron do IPEN. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 7., 31 ago. - 3 set, 1999, Belo Horizonte, MG. Anais... Rio de Janeiro: ABEN, 1999, 1999.

    Palavras-Chave: tin 117; radioisotopes; production; tin; irradiation; proton beams; proton reactions; antimony 117; tin isotopes; antimony isotopes; ion exchange chromatography; technetium 99; nuclear medicine

  • IPEN-DOC 29113

    BARCELLOS, HENRIQUE ; MATSUDA, HYLTON ; LAPOLLI, ANDRE L. ; SUMIYA, LUIZ C. do A. ; JUNQUEIRA, FERNANDO de C. ; COSTA, OSVALDO L. da . Design and assembly of an XY-type beam current monitor for cyclotron accelerators. Applied Radiation and Isotopes, v. 192, p. 1-5, 2023. DOI: 10.1016/j.apradiso.2022.110550

    Abstract: A water-cooled XY-type beam current monitor was designed, manufactured and assembled in a cyclotron accelerator beam transport line. Tests were performed, demonstrating that apparatus is an instrument of great assistance in proton beam position. The XY-type beam current monitor has been widely used in liquid target irradiations, employing irradiation system which were originally designed for irradiations on 18 MeV cyclotron accelerator (Cyclone 18, IBA) only, however, with this apparatus, the target may be exchanged between the 30 MeV (Cyclone 30, IBA) and 18 MeV cyclotrons.

    Palavras-Chave: cyclotrons; beam monitors; beam analyzers; proton beams; targets

  • IPEN-DOC 29096

    BURIN, A.L. ; BRANCO, I.S.L. ; YORIYAZ, H. . Determination of WER and WET equivalence estimators for proton beams in the therapeutic energy range using MCNP6.1 and TOPAS codes. Radiation Physics and Chemistry, v. 203, n. Part A, p. 1-9, 2023. DOI: 10.1016/j.radphyschem.2022.110606

    Abstract: To use the dosimetric advantages that proton therapy provides, the exact knowledge of the range and its associated parameters of the beam is essential. Since the human body is composed of several tissues whose composition and density differ from water it is important to relate the range in water to the range in those tissues. Those range associated parameters are the Water Equivalent Ratio (WER) and Water Equivalent Thickness (WET). This work presents the Range, WER and WET values obtained from the simulations using the Monte Carlo codes MCNP6.1 and TOPAS for several tissue-equivalent materials, which are materials that reproduce the radiation behavior of the human tissues in a phantom. Simulations have been done in the therapeutic proton energy range from 70 to 225 MeV. Therefore, the main objective of this work is to provide and contribute to the improvement of dose calculation in proton therapy, more specifically in the calculation of WER and WET in tissue equivalent medium. The results showed good agreement between codes, presenting only small differences less than 1.9% in the cortical bone, but they did not affect the dose calculation in the therapeutic range used in this study.

    Palavras-Chave: proton beams; thickness; water; monte carlo method; particles; simulation

  • IPEN-DOC 21165

    CARMO, LUCAS S. do . Dosimetria termoluminescente de altas doses de raios gama, raios beta, feixe de prótons e de nêutrons epitérmicos utilizando minerais naturais de silicatos e dosímetros de LiF: Mg, Cu, P (MCP) / High-dose thermoluminescent dosimetry of gamma rays, beta rays, proton beams and epithermal neutrons using natural silicate minerals and LiF: Mg, Cu, P (MCP) detectors . 2015. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 90 p. Orientador: Shigueo Watanabe. DOI: 10.11606/D.85.2015.tde-09102015-084259

    Abstract: No mundo de hoje, onde o uso da radiação de diversas naturezas está generalizado, a quantificação da energia depositada por essas diferentes radiações se tornou uma atividade de grande importância, principalmente quando a faixa de energia é considerada elevada, estas altas energias de radiação estão presentes, geralmente, em aceleradores de partículas, reatores nucleares e em irradiadores industriais, por exemplo. Este trabalho tem como objetivo medir altas doses de radiação de raios gama, feixes de elétrons e feixes de prótons utilizando duas variedades de um silicato natural (água-marinha e goshenita) e medir altas doses de nêutrons epitérmicos de alta fluência utilizando dosímetros de Fluoreto de Lítio dopados com Mg, Cu e P (MCP). A técnica utilizada para medir a dose absorvida por esses materiais foi a termoluminescência. As irradiações com raios- γ provenientes de fontes de 60Co foram de 100 kGy a 2000 kGy para a água-marinha e de 600 kGy a 2000 kGy para a goshenita, os resultados de intensidade TL vs Dose mostram que a partir de certa dose - 250 kGy e 1234,8 kGy para água-marinha e goshenita, respectivamente - o sinal TL começa a decrescer. Foi observado neste trabalho que, estes materiais quando irradiados com tais doses e posteriormente irradiados com doses baixas de alguns Gys até cerca de 400-500 Gy, o sinal TL decresce regularmente, podendo ser utilizado na dosimetria das radiações nessa faixa de dose. Para a irradiação de feixe de prótons e de feixe de elétrons foram utilizados dosímetros em placa de goshenita e dosímetros de pastilhas de água-marinha, a carga do feixe de prótons vai de 20 a 216 μC e a dose do feixe de elétrons vai de 10 kGy a 70 kGy. As irradiações com nêutrons epitérmicos utilizando LiF: Mg, Cu, P foram realizadas no reator IEA-R1/IPEN com fluências de 1014 a 1017 n/cm² e a quantificação das doses absorvidas foram realizadas utilizando o método UHTR (Ultra High Temperature Ratio).

    Palavras-Chave: thermoluminescent dosimetry; gamma radiation; beta sources; proton beams; epithermal neutrons; silicate minerals; lithium fluorides; magnesium; copper; phosphorus; radiation detectors

  • IPEN-DOC 06867

    LANDINI, LILIANE . Estudo da producao de sup(57)Co e sup(109)Cd em ciclotron. 2000. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 112 p. Orientador: Joao Alberto Osso Junior.

    Palavras-Chave: cobalt 57; cadmium 109; isotope production; nickel; irradiation; proton beams; cyclotrons; parametric analysis; ion exchange chromatography; nickel

  • IPEN-DOC 11586

    SUMIYA, LUIZ C. do A. . Estudo de parâmetros relevantes na irradiação de sup(124)Xe, visando a otimização na obtenção de sup(123)I ultra puro no ciclotron cyclone-30 IPEN-CNEN/SP. 2006. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Valdir Sciani. DOI: 10.11606/T.85.2006.tde-06062007-164028

    Abstract: O desenvolvimento da Medicina Nuclear, aliado à evolução dos equipamentos de diagnóstico e terapia, necessita, cada vez mais, da disponibilidade comercial de radioisótopos. Nesse contexto, o IPEN tem buscado atender e abastecer o mercado nacional. Um dos investimentos nesta área foi a aquisição de um ciclotron de 30 MeV, modelo Cyclone-30, que permitiu a produção dos radioisótopos tais como, o 18F, 67Ga, 201Tl e o 123I, sendo este último o foco do presente trabalho. Através de dados de produções rotineiras de 123I via irradiação com prótons em alvo gasoso de Xenônio com enriquecimento superior a 99,8% em 124Xe, foi realizado um estudo para identificar os fatores relevantes que influenciam diretamente o rendimento de obtenção de 123I com altíssimo grau de pureza. Embora a metodologia seja bem conhecida, quando se trata de produção comercial há uma escassez de dados sobre os parâmetros operacionais utilizados. Os parâmetros avaliados foram: pressão do gás 124Xe, intensidade de corrente de feixe de prótons, tempo de irradiação, temperatura de operação do sistema durante a irradiação, tempo de espera para formação de 123I, tempo de aquecimento do porta-alvo para recuperação do 123I formado, temperatura de aquecimento da solução de lavagem e influência do revestimento interno da câmara de irradiação com Ni. Com os resultados obtidos, foi possível alterar as condições operacionais nas produções rotineiras, conduzindo a um aumento de eficiência do processo em torno de 30%.

    Palavras-Chave: radioisotope generators; isotope production; cyclone cyclotron; irradiation; xenon 124; iodine 123; proton beams; efficiency; quality assurance

  • IPEN-DOC 27941

    BRANCO, I.S.L. ; ANTUNES, P.C.G. ; SIQUEIRA, P.T.D. ; SHORTO, J.M.B. ; YORIYAZ, H. . Estudo dos efeitos de composição e densidade de materiais tecido equivalentes na distribuição de dose longitudinal em protonterapia / Study of the composition and density effects of tissue equivalent materials on the longitudinal dose distribution in proton therapy. In: CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 24., 21-24 de agosto, 2019, Santos, SP. Anais... São Paulo, SP: Associação Brasileira de Física Médica, 2019. p. 1-6.

    Abstract: A eficiência de procedimentos radioterápicos depende do equilíbrio entre o fornecimento de altas doses conformadas ao volume tumoral e a restrição das doses recebidas pelos tecidos e órgãos saudáveis circundantes. Sendo uma modalidade de radioterapia, a protonterapia destaca-se neste cenário por possuir vantagens dosimétricas, que, quando combinadas com avanços tecnológicos, permitem que um grande potencial na conformidade da distribuição de dose. Este trabalho visa contribuir em um estudo dosimétrico, especificamente considerando os efeitos da heterogeneidade devido à presença de materiais tecido equivalentes com diferentes densidades e composições químicas, de modo a analisar qual destes parâmetros exerce maior influência na distribuição de dose longitudinal. A metodologia desenvolvida neste trabalho foi baseada em simulações de Monte Carlo com o código GEANT4 (através da interface TOPAS). Os objetos simuladores cilíndricos representados foram compostos inteiramente por diversos materiais tecido-equivalentes. Três grupos de estudo guiaram as simulações, o primeiro manteve a composição e densidade originais dos materiais, ao seguinte foi atribuída a todos os materiais heterogêneos a mesma densidade da água, mas mantiveram-se suas composições químicas originais; e por fim, foram realizadas simulações com as densidades originais dos materiais heterogêneos e composição química da água para todos os casos. Através da análise da distribuição de dose longitudinal variando com a profundidade, foi possível observar o comportamento da influência dos parâmetros de composição e densidade no alcance do feixe (d90) para os diferentes materiais e energias analisados. O estudo mostrou que, o efeito que a densidade dos materiais tecido equivalentes exerce sobre a deposição de dose é mais expressivo que o efeito de sua composição. A maior exatidão no range de tratamento permite evitar uma sub ou sobre dosagem da área irradiada. Esta é uma das diversas linhas de pesquisa que contribuem para a diminuição das incertezas em protonterapia.

    Palavras-Chave: radiotherapy; proton beams; radiation dose distributions; tissue-equivalent materials; monte carlo method; heterogeneous effects

  • IPEN-DOC 26444

    YORIYAZ, HELIO ; BRANCO, ISABELA S.L. ; ALMEIDA, ISABEL P.; FONSECA, GABRIEL P.. Fundamentos de transporte e cálculo de dose em tratamentos com feixes de prótons / Fundamentals of transport and dose calculation in proton beam therapy. Revista Brasileira de Física Médica, v. 13, n. 1, p. 109-115, 2019. DOI: 10.29384/rbfm.2019.v13.n1.p109-115

    Abstract: Este artigo de revisão apresenta um breve histórico, com os principais fatos da evolução da terapia com feixe de prótons, seguido de uma descrição das principais características dosimétricas apresentadas em faixas de energia utilizadas em terapia. É feita uma breve comparação entre a protonterapia e as demais modalidades de radioterapia com feixe de fótons. Também estão descritos alguns códigos de Monte Carlo atualmente utilizados na simulação do transporte de prótons no meio e suas peculiaridades.

    Palavras-Chave: calculation methods; comparative evaluations; computerized simulation; dosimetry; monte carlo method; photon beams; planning; proton beams; proton transport; radiation dose distributions; radiotherapy

  • IPEN-DOC 24481

    MAIORINO, J.R. ; PEREIRA, S.A. ; SANTOS, A. ; SILVA, A.T. . MEA - Modified Energy Amplifier proposal. In: INTERNATIONAL SYMPOSIUM ON UTILIZATION OF ACCELERATORS, November 26-30, 2001, São Paulo, SP. Abstract... Vienna, Austria: International Atomic Energy Agency (IAEA), 2001. p. 19-19.

    Observação: Report Number IAEA-SM-366/101

    Abstract: Recently Rubbia et al proposed a conceptual design of an Accelerator Driven System, known as Energy Amplifier (EA), as an advanced innovative reactor which utilizes a spallation neutron source induced by protons, from a Cyclotron or Linac, in a subcritical array imbibed in liquid lead coolant. Besides of being breeder and waste burner, the conceptual design generates energy and allows the use of Thorium as fuel. This paper introduces some qualitative changes in the Rubbia's concept. More than one point of spallation is proposed in order to reduce the requirement of proton energy and current of the accelerator, and mainly to make a flatter power density distribution. The subcritical core, which in the Rubbia's concept is an hexagonal array of pins immersed in a liquid lead coolant, is replaced by a concept of a solid lead calandria with the fuel elements in channels cooled by Helium. This concept allows on line refueling or shuffling, and the utilization of a direct thermodynamic cycle (Brayton), which is more efficient than a vapor cycle. Although the calculations to demonstrate the feasibility of the MEA concept are underway and not yet finished, these ideas do not violate the basic physics of the EA, but reduces requirement in the accelerator complex, which is more realistic and economical in today accelerators technology. Finally, the utilization of He as coolant, compared with liquid Pb, is more realistic since the gas cooled reactors technology is well established and more efficient from the thermodynamic view, allowing simplification and the utilization in high temperature process, like hydrogen generation.

    Palavras-Chave: accelerator breeders; comparative evaluations; cyclotrons; helium cooled reactors; linear accelerators; liquid metal cooled reactors; proton beams; proton beams

  • IPEN-DOC 10551

    BRINGAS, F.; YAMASHITA, M.T.; GOLDMAN, I.D.; PASCHOLATI, P.R.; SCIANI, V. . Measurement of proton-induced reaction cross sections in Ti, Ni and Zr near the Threshold. In: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, Sept. 26 - Oct. 1, 2004, Santa Fe, New Mexico. Proceedings... 2004.

    Palavras-Chave: cross sections; energy resolution; foils; high-purity ge detectors; kev range; mev range; nickel 56; proton beams; proton reactions; proton-nucleon interactions; protons; titanium 44; zirconium 88

  • IPEN-DOC 14549

    OLIVEIRA, HENRIQUE B. de . Modelos analiticos para o desenvolvimento de alvos metalicos de alta performance irradiados nos ciclotrons cyclone 30 e cyclone 18 do IPEN-CNEN/SP / Analytical models for development of high performance metal targets irradiated in IPEN-CNEN/SP cyclone 30 and cyclone 18 cyclotrons . 2009. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, Sõo Paulo. 194 p. Orientador: Valdir Sciani. DOI: 10.11606/T.85.2009.tde-22092011-095307

    Abstract: Foram desenvolvidos modelos analíticos que descrevem os elementos básicos para irradiações de alvos metálicos em ciclotrons. Parâmetros importantes como valor máximo de corrente de feixe e potência térmica depositada sobre o alvo foram obtidos e confrontados com situações práticas. De forma totalmente inédita, foram determinados analiticamente as características encontradas em situações de intensos transientes térmicos, quando altas concentrações de prótons em uma pequena região do feixe provocam intensos gradientes de temperatura em pequenas regiões do alvo. A comparação dos resultados obtidos com aqueles encontrados na literatura mostraram que os modelos desenvolvidos são satisfatórios, tendo em vista todas as limitações do modelo proposto.

    Palavras-Chave: cyclones; targets; irradiation; radioisotopes; cyclone cyclotron; temperature gradients; transients; proton beams; protons

  • IPEN-DOC 03590

    SANTOS, L.L.M. ; OSSO JUNIOR, J.A. . Producao de cobalto57 da irradiacao de niquel com protons no ciclotron CV-28 do IPEN-CNEN/SP. In: 6o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 27 de outubro - 1 de novembro, 1996, Rio de Janeiro, RJ. 1996.

    Palavras-Chave: cobalt 57; cyclotrons; irradiation; nickel; proton beams; targets; radioisotopes; impurities; excitation functions; nuclear reactions

  • IPEN-DOC 04904

    SANTOS, L.L.M. ; OSSO JUNIOR, J.A. . Reacoes nucleares induzidas por protons em niquel natural, para a producao de sup(57)Co, no Ciclotron do IPEN. In: 4th MEETING ON NUCLEAR APPLICATIONS, ENCONTRO NACIONAL DE APLICACOES NUCLEARES, August 18-22, 1997, Pocos de Caldas, MG. 1997. p. 1023-1026.

    Palavras-Chave: cyclotrons; brazilian cnen; nuclear reactions; cross sections; proton beams; nickel; foils; cobalt 57; targets; gamma spectroscopy

  • IPEN-DOC 24094

    BARCELLOS, HENRIQUE ; MATSUDA, HYLTON ; SUMIYA, LUIZ C. do A. ; JUNQUEIRA, FERNANDO de C. ; COSTA, OSVALDO L. da . A simple and powerful XY-type current monitor for 30 MeV IPEN/CNEN-SP cyclotron. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A water-cooled XY-type current monitor was designed and built in the Cyclotrons Laboratory of the Nuclear and Energy Research Institute (IPEN). It is a very simple design and easily adaptable to the cyclotron beam lines. Tests were done demonstrating to be an instrument of great assistance in proton beam position along beam transport line and target port. Nowadays the XY-type current monitor has been widely used in 18F-FDG routine productions, employing irradiation system which were originally designed for productions on 18 MeV cyclotron accelerator only, however, applying the XY-type current monitor the target port may be exchanged between the 30 MeV and 18 MeV cyclotrons and the observed results are in perfect agreement with expected.

    Palavras-Chave: beam currents; beam monitoring; beam monitors; design; mev range 10-100; proton beams; testing

  • IPEN-DOC 07788

    LANDINI, L. ; OSSO JUNIOR, J.A. . Sup(57)Co produzido em ciclotron. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 5., 5-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: cobalt 57; radiation sources; radioisotopes; isotope production; cyclotrons; nickel; irradiation; proton beams

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.