INSTITUTO DE PESQUISAS ENERGÉTICAS E NUCLEARES
Repositório Digital da Produção Técnico Científica

Navegação por Agências de fomento "Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)"

Navegação por Agências de fomento "Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 26034

    SOUZA, LUCAS W.G.; POZZO, LORENA ; PERINI, ANA P. ; BELINATO, WALMIR; SANTOS, WILLIAM S.; CALDAS, LINDA V.E. ; NEVES, LUCIO P.. Monte Carlo simulation of microPET/CT occupational exposure using 18F and 68Ga tracers. In: RUBIO, MARCELO (Ed.); TIRAO, GERMAN (Ed.) INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 14th, October 7-11, 2018, Córdoba, Argentina. Abstract... Córdoba: Centro de Excelencia en Productos y Procesos, 2018. p. 179-179.

  • IPEN-DOC 26036

    SANTOS, WILLIAM S.; SANTOS, CARLA J.; NEVES, LUCIO P.; BELINATO, WALMIR; CALDAS, LINDA V.E. ; PERINI, ANA P. . Numerical dosimetry in brachytherapy to variable mama sizes using two different types of 125I seeds. In: RUBIO, MARCELO (Ed.); TIRAO, GERMAN (Ed.) INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 14th, October 7-11, 2018, Córdoba, Argentina. Abstract... Córdoba: Centro de Excelencia en Productos y Procesos, 2018. p. 190-190.

  • IPEN-DOC 24376

    SANTOS, WILLIAM S.; BELINATO, WALMIR; PERINI, ANA P. ; CALDAS, LINDA V.E. ; GALEANO, DIEGO C.; SANTOS, CARLA J.; NEVES, LUCIO P. . Occupational exposures during abdominal fluoroscopically guided interventional procedures for different patient sizes — A Monte Carlo approach. Physica Medica - European Journal of Medical Physics, v. 45, p. 35-43, 2018. DOI: 10.1016/j.ejmp.2017.11.016

    Abstract: In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes. In addition to these phantoms, a female and a male phantom, named FASH3 and MASH3 (reference virtual anthropomorphic phantoms), were also used to represent the medical radiation workers. The CC values, obtained as a function of the dose area product, were calculated for 87 exposure scenarios. In each exposure scenario, three phantoms, implemented in the MCNPX 2.7.0 code, were simultaneously used. These phantoms were utilized to represent a patient and medical radiation workers. The results showed that increasing the BMI of the patient, adjusted for each patient protocol, the CC values for medical radiation workers decrease. It is important to note that these results were obtained with fixed exposure parameters.

    Palavras-Chave: radiology; dosimetry; phantoms; occupational exposure; monte carlo method; patients

  • IPEN-DOC 26022

    BELINATO, W.; ALMEIDA, E.P.B. de; NEVES, L.P.; PERINI, A.P. ; CALDAS, L.V.E. ; SANTOS, W.S.. Occupational exposures in PET procedures with 18F-FDG. In: RUBIO, MARCELO (Ed.); TIRAO, GERMAN (Ed.) INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 14th, October 7-11, 2018, Córdoba, Argentina. Abstract... Córdoba: Centro de Excelencia en Productos y Procesos, 2018. p. 55-55.

  • IPEN-DOC 29512

    MARCONDES, POLLYANA; ROSAS, GISELA H.; GONZALEZ, MARIA E.L.; QUEIROZ, ALVARO A.A. de ; MARQUES, PAULO S.. Poly(vinyl alcohol)/poly(glycerol) dendrimer hydrogel mediated green synthesis of silver nanoparticles. Polímeros, v. 32, n. 3, p. 1-9, 2022. DOI: 10.1590/0104-1428.20220025

    Abstract: In this paper, we report the synthesis and evaluation of a poly(vinyl alcohol)/poly(glycerol) dendrimer hydrogel incorporated with green synthesized silver nanoparticles (PVA/PGLD-AgNPs) using Cinnamomum verum extract as the reducting agent (Cz-extract). The Cz-extract was prepared using ultrasonic technique. UV-visible (UV-vis) spectra of Cz-extract confirmed the presence of cinnamaldehyde. PVA/PGLD-AgNPs films were prepared using 5, 10 and 20 mL of Cz-extract and characterized by UV-vis, Fourier transform infrared spectroscopy, Thermogravimetric analysis and X-ray diffraction (XRD). The surface plasmon resonance band in the UV-vis spectra confirmed the formation of AgNPs. XRD pattern confirmed the presence of silver, with average crystallite sizes calculated by Scherrer equal to 13.64 nm, 16.63nm and 20.27 nm for AgNPs prepared with 5 mL, 10 mL and 20 mL of Cz-extract, respectively. AgNPs release kinetic was studied by Korsmeyer– Peppas model. The antimicrobial results revealed that the PVA/PGLD-AgNPs hydrogels showed good antibacterial activity behavior against Escherichia coli.

  • IPEN-DOC 28410

    SILVA, MATHEUS S.; TAVARES, ANA P.M.; COELHO, LUIZ F.L.; DIAS, LIGIA E.M.F. ; CHURA-CHAMBI, ROSA M. ; FONSECA, FLAVIO G. da; SALES, MARIA G.F.; FIGUEIREDO, EDUARDO C.. Rational selection of hidden epitopes for a molecularly imprinted electrochemical sensor in the recognition of heat-denatured dengue NS1 protein. Biosensors and Bioelectronics, v. 191, p. 1-8, 2021. DOI: 10.1016/j.bios.2021.113419

    Abstract: Rational selection of predicted peptides to be employed as templates in molecular imprinting was carried out for the heat-denatured non-structural protein 1 (NS1) of dengue virus (DENV). Conservation analysis among 301 sequences of Brazilian isolates of DENV and zika virus (ZIKV) NS1 was carried out by UniProtKB, and peptide selection was based on in silico data of the conservational, structural and immunogenic properties of the sequences. The selected peptide (from dengue 1 NS1) was synthesized and employed as a template in the electropolymerization of polyaminophenol-imprinted films on the surface of carbon screen-printed electrodes. Heat denaturation of the protein was carried out prior to analysis, in order to expose its internal hidden epitopes. After removal of the template, the molecularly imprinted cavities were able to rebind to the whole denatured protein as determined by electrochemical impedance spectroscopy. This label-free sensor was efficient to distinguish the NS1 of DENV from the NS1 of ZIKV. Additionally, the sensor was also selective for dengue NS1, in comparison with human serum immunoglobulin G and human serum albumin. Additionally, the device was able to detect the DENV NS1 at concentrations from 50 to 200 μg L−1 (RSD below 5.04%, r = 0.9678) in diluted human serum samples. The calculated LOD and LOQ were, respectively, 29.3 and 88.7 μg L−1 and each sensor could be used for six sequential cycles with the same performance.

    Palavras-Chave: viral diseases; viral diseases; zika virus; protein denaturation; polymers; sensors

  • IPEN-DOC 26030

    AMARAL, CAIO E.S.; LIMA, CAIO L.; BELINATO, WALMIR; NEVES, LUCIO P.; PERINI, ANA P. ; SANTOS, WILLIAM S.; ALMEIDA, EDSON P.B. de; NAVARRO, MARCUS V.T.. Simulation of a laboratory for the radiation detectors calibration. In: RUBIO, MARCELO (Ed.); TIRAO, GERMAN (Ed.) INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 14th, October 7-11, 2018, Córdoba, Argentina. Abstract... Córdoba: Centro de Excelencia en Productos y Procesos, 2018. p. 103-103.

  • IPEN-DOC 25155

    SILVA, ANDERSON G.M. da; BATALHA, DANIEL C.; RODRIGUES, THENNER S. ; CANDIDO, EDUARDO G.; LUZ, SULUSMON C.; FREITAS, ISABEL C. de; FONSECA, FABIO C. ; OLIVEIRA, DANIELA C. de; TAYLOR, JASON G.; TORRESI, SUSANA I.C. de; CAMARGO, PEDRO H.C.; FAJARDO, HUMBERTO V.. Sub-15 nm CeO2 nanowires as an efficient nonnoble metal catalyst in the room-temperature oxidation of aniline. Catalysis Science and Technology, v. 8, n. 7, p. 1828-1839, 2018. DOI: 10.1039/c7cy02402a

    Abstract: We described herein the facile synthesis of sub-15 nm CeO2 nanowires based on a hydrothermal method without the use of any capping/stabilizing agent, in which an oriented attachment mechanism took place during the CeO2 nanowire formation. The synthesis of sub-15 nm CeO2 nanowires could be achieved on relatively large scales (∼2.6 grams of nanowires per batch), in high yields (>94%), and at low cost. To date, there are only a limited number of successful attempts towards the synthesis of CeO2 nanowires with such small diameters, and the reported protocols are typically limited to low amounts. The nanowires displayed uniform shapes and sizes, high surface areas, an increased number of oxygen defects sites, and a high proportion of Ce3+/Ce4+ surface species. These features make them promising candidates for oxidation reactions. To this end, we employed the selective oxidation of aniline as a model transformation. The sub-15 nm CeO2 nanowires catalyzed the selective synthesis of nitrosobenzene (up to 98% selectivity) from aniline at room temperature using H2O2 as the oxidant. The effect of solvent and temperature during the catalytic reaction was investigated. We found that such parameters played an important role in the control of the selectivity. The improved catalytic activities observed for the sub-15 nm nanowires could be explained by: i) the uniform morphology with a typical dimension of 11 ± 2 nm in width, which provides higher specific surface areas relative to those of conventional catalysts; ii) the significant concentration of oxygen vacancies and high proportion of Ce3+/Ce4+ species at the surface that represent highly active sites towards oxidation reactions; iii) the crystal growth along the (110) highly catalytically active crystallographic directions, and iv) the mesoporous surface which is easily accessible by liquid substrates. The results reported herein demonstrated high activities under ambient conditions, provided novel insights into selectivities, and may inspire novel metal oxide-based catalysts with desired performances.

    Palavras-Chave: nanostructures; nanowires; cerium oxides; aniline; oxidation; catalytic effects; synthesis

  • IPEN-DOC 26134

    SANTOS, WILLIAM S. ; NEVES, LUCIO P.; PERINI, ANA P.; SANTOS, CARLA J.; BELINATO, WALMIR; CALDAS, LINDA V.E. . The influence of the lead eyewear geometry on the doses to the eye lens. In: ABEN (Ed.) INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro, 2019. p. 186-191.

    Abstract: The scattered radiation from interventional procedures is an important source of radiological risk for the medical staff. Considering all affected organs, the eye lens are among the most critical organs. As pointed out by several studies, even for low radiation doses, the appearance of cataract may occur. Considering this scenario, the radiation doses to the eye lens were determined using three different lead eyewear models commonly employed. The fluoroscopist was represented by an adult virtual anthropomorphic phantom (MASH3), coupled to the Monte Carlo code MCNP6.1™, in a typical cardiac interventional radiology procedure. The eyewear had 0.5 mmPb each, and the evaluation was carried out for four different beam angulations (PA, LAO90, LAO65 e RAO65), 80 kVp of tube voltage and HVL of 4 mmAl. The results pointed out that the shielding efficiency has a strong dependence on the eyewear type utilized, which may be very useful for the decision-making during the acquisition of such equipments.

    Palavras-Chave: crystalline lens; equivalent radiation doses; fluoroscopy; lead; monte carlo method; occupational exposure; phantoms; radiation protection; shielding

  • IPEN-DOC 27869

    SANTOS, W.S.; NEVES, L.P.; PERINI, A.P.; SANTOS, C.J.; BELINATO, W.; CALDAS, L.V.E. . The influence of the lead eyewear geometry on the doses to the eye lens. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-9, 2021. DOI: 10.15392/bjrs.v9i1A.1347

    Abstract: The scattered radiation from interventional procedures is an important source of radiological risk for the medical staff. Considering all affected organs, the eye lens is among the most critical organs. As pointed out by several studies, even for low radiation doses, the appearance of cataract may occur. Considering this scenario, the radiation doses to the eye lens were determined using three different lead eyewear models commonly employed in the interventional radiology. The interventional radiologist was represented by an adult virtual anthropomorphic phantom (MASH3), coupled to the Monte Carlo code MCNP 6.1, in a typical cardiac interventional radiology procedure. The eyewear had a thickness 0.5 mmPb each, and the evaluation was carried out for four different beam angulations (PA, LAO90, LAO65 e RAO65), utilizing a tube voltage of 80 kVp, and HVL of 4 mmAl. The results pointed out that the shielding efficiency has a strong dependence on the eyewear type utilized, which may be very useful for the decision-making during the acquisition of such equipments.

    Palavras-Chave: crystalline lens; equivalent radiation doses; fluoroscopy; glass; lead; monte carlo method; occupational exposure; phantoms; radiation protection; shielding

  • IPEN-DOC 27216

    SOARES, MARIA R. ; SANTOS, WILLIAM S. ; NEVES, LUCIO P.; PERINI, ANA P.; BATISTA, WILSON O.G.; MAIA, ANA F.; BELINATO, WALMIR; CALDAS, LINDA V.E. . The use of personal protection equipment for the absorbed doses of eye lens and thyroid gland in CBCT exams using Monte Carlo. Radiation Physics and Chemistry, v. 167, p. 1-6, 2020. DOI: 10.1016/j.radphyschem.2019.108347

    Abstract: The purpose of this study was to evaluate the absorbed dose in the thyroid and eye lens when the patient uses individual protection. For this purpose, Monte Carlo (MC) simulation was employed using five different field of view (FOV) sizes, available in the i-Cat classic CBCT equipment. To represent the patient, a male virtual anthropomorphic phantom was used. Three different models of lead eyewear and thyroid shield were evaluated, as well as the dose difference with and without the personal protection equipment. The difference in the absorbed dose in relation to the use of the lead eyewear presented a reduction of 19% for the 8 cm×6 cm FOV (diameter×height), and 73% for the 14 cm×22 cm FOV. In relation to the thyroid, only the shield that involved the whole neck contributed to the reduction of the absorbed dose by up to 72% for a 14 cm×22 cm FOV. For the thyroid shields there was a maximum increase of 59% (14 cm×6 cm FOV), consequently, increasing the effective dose for the protocol. The results showed that the lead eyewear contributed to the protection of the eye lens, but the efficiency of the thyroid shield depends on several factors, as FOV and shield model.

    Palavras-Chave: radiation protection; computerized tomography; monte carlo method; simulation; protective clothing; equipment; eyes; phantoms; neck

  • IPEN-DOC 27236

    SANTOS, W.S. ; NEVES, L.P.; PERINI, A.P.; CALDAS, L.V.E. . Uso de modelagem computacional para avaliação da exposição médica e ocupacional durante procedimento de cardiologia intervencionista. Brazilian Journal of Radiation Sciences, v. 8, n. 1A, p. 1-12, 2020. DOI: 10.15392/bjrs.v8i1A.1086

    Abstract: A cardiologia intervencionista (CI) é uma modalidade comum que utiliza imagens fluoroscópicas para o diagnóstico e a terapia de problemas cardiovasculares. Embora os equipamentos de fluoroscopia mais modernos empreguem sistema de redução de dose, além de feixes bem colimados, a radiação espalhada atinge órgãos circundantes do paciente que não estão localizados no feixe primário de radiação. A radiação espalhada pelo corpo do paciente acarreta a exposição ocupacional do médico intervencionista. A avaliação das exposições ocupacional e médica é importante para a determinação dos riscos e das consequências biológicas em diferentes órgãos e tecidos. Neste trabalho, a avalição foi feita por meio do conceito de coeficiente de conversão (CC). Para quantificar os valores de CC, foi utilizado o programa computacional MCNPX e o simulador antropomórfico masculino virtual adulto (MASH3), para representar o paciente e o médico. Os resultados comprovaram a eficiência da proteção dos equipamentos suspensos. Quando não utilizados, um aumento dos valores de CC de dose efetiva podem ser superiores a 1000%.

    Palavras-Chave: cardiovascular diseases; computerized simulation; effective radiation doses; equivalent radiation doses; lenses; medical personnel; monte carlo method; occupational exposure; patients; phantoms; photon beams; radiation protection

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.