  • IPEN-DOC 07092

    COSTA, F.E. ; HAMADA, M.M. . Development of a portable counter with data acquisition system for flow measurements, using radioactive tracers. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; radioisotopes; fluid flow; pulses; data acquisition systems; cesium iodides; thallium; photodiodes; industrial plants

  • IPEN-DOC 09093

    COSTA, F.E. ; HAMADA, M.M. . Development of a scintillator detector set with counter and data acquisition for flow measurements. Nuclear Instruments and Methods in Physics Research, v. 486, n. 1/2, Section A, p. 150-155, 2002.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; cesium iodides; thallium; photodiodes; fluid flow; data acquisition systems; pulses

  • IPEN-DOC 09071

    COSTA, F.E. ; HAMADA, M.M. . Development of a scintillator detector set with counter and data acquisition for flow measurements. In: AUFFRAY, E. (Ed.); CHIPAUX, R. (Ed.); LECOQ, P. (Ed.); PEDRINI, C. (Ed.); SCHNEEGANS, M. (Ed.) INTERNATIONAL CONFERENCE ON INORGANIC SCIN TILLATORS AND THEIR USE IN SCIENTIFIC AND INDUSTRIAL APPLICATIONS, 6th, Sept. 16-21, 2001, Chamonix, France. Proceedings... 2001. p. 150-155.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; cesium iodides; thallium; photodiodes; fluid flow; data acquisition systems; pulses

  • IPEN-DOC 15081

    BRANCACCIO, FRANCO ; DIAS, MAURO da S. ; TOLEDO, FABIO . Development of an analysis methodology applied to 4'pi'beta'gama' software coincidence data acquisition system. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: c codes; cobalt 60; coincidence methods; counting rates; data acquisition systems; experimental data; four-pi counting; l codes; proportional counters; radiation sources; standardization

  • IPEN-DOC 11925

    BUENO, ELAINE I.; TING, DANIEL K.S. ; GONCALVES, IRACI M. P. . Development of an artificial neural network for monitoring and diagnosis of sensor fault and detection in the IEA-R1 research reactor at IPEN. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... São Paulo: ABEN, 2007, 2007.

    Palavras-Chave: artificial intelligence; data acquisition systems; dose rates; experimental data; fuzzy logic; iear-1 reactor; m codes; neural networks; power distribution; reactor monitoring systems; reactor operation; system failure analysis; temperature measurement; thermocouples

  • IPEN-DOC 10734

    BUENO, E.I.; TING, D.K.S. ; GONCALVES, I.M.P. . Development of an artificial neural network for nuclear power monitoring and fault detection in the IEA-R1 research reactor at IPEN. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE FISICA E REATORES THERMAL HIDRAULICA, 14th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: artificial intelligence; data acquisition systems; iear-1 reactor; m codes; neural networks; reactor monitoring systems

  • IPEN-DOC 15082

    LAPOLLI, ANDRE L. ; YAMAGISHI, SUELI; DOMIENIKAN, CLAUDIO ; SCHOUERI, ROBERTO M. ; CARBONARI, ARTUR W. ; SAXENA, RAJENDRA N. . Development of an object-oriented software based on fuzzy-logic for controlling temperatures in pac experiments. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: algorithms; data acquisition systems; data acquisition; furnaces; fuzzy logic; java; m codes; perturbed angular correlation; temperature control; temperature dependence; v codes

  • IPEN-DOC 11251

    SILVA, ROSIANE A. da . Dosimetria de filtros dinamicos aprimorados. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Laura Natal Rodrigues. DOI: 10.11606/D.85.2006.tde-08012007-195253

    Abstract: O objetivo deste trabalho foi realizar a dosimetria de filtros dinâmicos aprimorados (“Enhanced Dynamic Wedge” – EDW). Isso foi feito com dois intuitos: 1) a avaliação da implementação clínica do filtro dinâmico aprimorado considerando-se suas vantagens e desvantagens; e 2) a comparação entre a eficiência e a melhor aplicabilidade de três sistemas dosimétricos diferentes em conjunto com o filtro dinâmico aprimorado. Os sistemas dosimétricos utilizados foram: o Sistema de Imagem de Feixe (“Beam Image System” – BIS2G), da Scanditronix-Wellhöfer, uma câmara de ionização cilíndrica de 0,6 cm3 do tipo Farmer, e um arranjo linear de câmaras de ionização múltiplas (“Ionization Chamber Linear Detector Array”) com 23 câmaras de ionização cilíndricas de 0,14 cm3, tipo Farmer. Com o Sistema de Imagem de Feixe – BIS2G foi possível obter curvas de fluência que permitiram analisar a simetria dos perfis de fluência, linearidade da dose, efeito da taxa de dose e efeito da gravidade, características diretamente ligadas à qualidade do funcionamento do filtro dinâmico aprimorado, além de ter sido possível também calcular o fator filtro para campos simétricos. Com a câmara de ionização mediu-se a porcentagem de dose em profundidade - PDP e calculou-se o fator filtro para campos simétricos e campos assimétricos (uma das vantagens do EDW). Com o arranjo linear de câmaras de ionização múltiplas foi possível obter curvas de isodose que permitiram a verificação da simetria e a comparação com os resultados obtidos com o BIS2G, além do cálculo do fator filtro para campos simétricos. O fator filtro calculado através de medidas tomadas com os três sistemas foi também comparado com resultados obtidos por dois formalismos, de Gibbons1 e de Klein et al 2, bem conhecidos da literatura e que serviram para a validação dos resultados e deste trabalho. Destas comparações verificou-se que os ângulos do filtro dinâmico aprimorado que apresentam maior diferença entre resultados obtidos e os formalismos foram os ângulos de 45º e de 60º em relação ao método de Klein et al que apresentaram diferenças de 2,1% em relação ao BIS2G, 1,9% em relação à câmara de ionização e 1,1% em relação ao arranjo linear de câmaras de ionização.

    Palavras-Chave: dosemeters; ionization chambers; radiation dose distributions; data acquisition systems; dosimetry; experimental data

  • IPEN-DOC 12194

    SANTOS, ADIMIR dos ; COSTA, PEDRO de C.. Elaboracao de uma base de dados experimentais para obtencao do nivel de subcriticalidade do reator IPEN/MB-01. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: critical mass; criticality; data acquisition systems; data acquisition; data analysis; data base management; ipen-mb-1 reactor; reactors; research reactors

  • IPEN-DOC 18295

    BETTI, FLAVIO ; POTIENS, MARIA da P.A. . Estudo de implantação de um sistema remoto de comando e coleta de dados para eletrômetros PTW-unidos. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE FISICA E REATORES THERMAL HIDRAULICA, 14th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: brazilian cnen; calibration; data acquisition systems; dosemeters; electrometers; l codes; remote control

  • IPEN-DOC 25119

    MURATA, H.M.; MORALLES, M. ; BONIFACIO, D.A.B.. Evaluation of digital methods for energy calculation and timing pick-off in positron emission tomography. Journal of Instrumentation, v. 13, n. P09024, 2018. DOI: 10.1088/1748-0221/13/09/P09024

    Abstract: Traditionally, pulse processing in Positron Emission Tomography (PET) has been based on analog or discrete circuits forming a decentralized processing system. However, there is a convergence for digital and integrated implementations due to the characteristics of the modern electronic devices which are real-time processing capable, such as Application-Specific Integrated Circuit (ASIC) and Field Programmable Gate Array (FPGA) with fast Analog to Digital Converters (ADC). However, FPGA can provide fast implementation at relatively low cost and also enables the development of sophisticated digital pulse processing algorithms to improve energy, position and time resolutions in PET systems. Our group has developed and evaluated one energy calculation and three timing pick-off methods for implementation onto an FPGA-based system. For a typical PET detector setup, our charge integration method presents energy resolution similar to previously designed PET detectors. The best performance for timing pick-off was achieved by the Initial Rise Interpolation (IRI) method, where a coincidence time resolution of around 440 ps is suitable for Time of Flight (TOF) PET. Future works include embedding the proposed algorithms in a FPGAbased data acquisition system under development by our group which will be employed in a PET prototype.

    Palavras-Chave: algorithms; analog-to-digital converters; data acquisition systems; design; energy resolution; evaluation; positron computed tomography; time resolution; time-of-flight method

  • IPEN-DOC 12195

    ANDRADE, DELVONEI A. de ; NETO, JOSE G.. Falcao - a relational database to storaging the variables monitored in the research reactor IEA-R1. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: data acquisition systems; data acquisition; data base management; iear-1 reactor; information dissemination; internet; numerical data; primary coolant circuits; temperature dependence

  • IPEN-DOC 12196

    KURAMOTO, RENATO Y.R.; SANTOS, ADIMIR dos ; JEREZ, ROGERIO ; DINIZ, RICARDO . Kinetic parameters determination through power sectral densities measurements using pulse-type detectors in the IPEN/MB-01 research reactor. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: data acquisition systems; delayed neutron fraction; experimental data; ipen-mb-1 reactor; neutron detectors; power density; prompt neutrons; reactor kinetics; reactor noise; rossi alpha method; spectral density

  • IPEN-DOC 27929

    VIEIRA NETO, ANTONIO S. ; OLIVA, AMAURY M. ; OLIVEIRA, PATRICIA da S.P. de ; HUNOLD, MARCOS C. ; SAUER, MARIA E.L.J. ; ANDREA, VINICIUS . Knowledge base about risk and safety of nuclear facilities to support analysts and decision-makers. Brazilian Journal of Radiation Sciences, v. 9, n. 2B, p. 1-11, 2021. DOI: 10.15392/bjrs.v9i2B.1501

    Abstract: Epistemic uncertainty (related to lack of knowledge), often found in the documentation of nuclear facility engineering projects, can affect the decision-making process of managers and analysts on safety and risk issues. This article conceptualizes the nature of the major uncertainties involved in engineering projects. It describes a knowledge base developed to gather data and information related to an Open-Pool Light-water Research Reactor (OPLRR) project and whose purpose is to assist professionals who work in nuclear facilities. To reduce the epistemic uncertainties that may arise in the project, the OPLRR knowledge base is designed with a set of information that allows identifying and facilitating the forwarding of solutions to address inconsistencies and/or pending issues that may exist in the project. In this sense, the information and the documents related to the project are organized in a graphical and hierarchical architecture, allowing the knowledge base users to quickly and easily obtain information regarding the systems, processes, equipment, and components of the project. Besides that, a set of documents containing descriptions, reliability data, and some other information about the systems and components are specially created to the knowledge base, and it is crucial to reduce epistemic uncertainties once it raises the issues and the inconsistencies of the project, as well as it clarifies the interrelations between the systems, the functioning of the equipment, their failures modes and the consequences of their failures, and some other data, which are not originally contained in the documents of the project.

    Palavras-Chave: knowledge base; information dissemination; data acquisition systems; decision making; failure mode analysis; pool type reactors

  • IPEN-DOC 06916

    NAHUEL CARDENAS, JOSE P. . Monitoracao continua do balanco termico para determinacao da potencia do reator IEA-R1. 2000. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 159 p. Orientador: Valdemir Gutierrez Rodrigues.

    Palavras-Chave: iear-1 reactor; reactor operation; reactor monitoring systems; data acquisition systems; computer graphics; reactor instrumentation; temperature measurement

  • IPEN-DOC 07208

    NAHUEL CARDENAS, J.P. ; RODRIGUES, V.G.. Monitoracao continua do balanco termico para determinacao da potencia do reator IEA-R1. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE FISICA DE REATORES E TERMOHIDRAULICA, 12., 15-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: iear-1 reactor; power; reactor cores; data acquisition systems; real time systems; on-line measurement systems; computer codes; temperature monitoring; fluid flow

  • IPEN-DOC 11298

    GONCALVES, IRACI M. P. . Monitoração e diagnóstico para detecção de falhas de sensores utilizando a metodologia GMDH. 2006. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Daniel Kao Sun Ting. DOI: 10.11606/T.85.2006.tde-04062012-144516

    Abstract: O sistema de detecção de falhas e diagnóstico é um sistema de suporte ao operador dedicado a funções específicas que alertam os operadores para problemas de falhas em sensores e atuadores, e auxiliam no diagnóstico antes que os limites normais de alarmes sejam atingidos. Sistemas de suporte ao operador surgiram para diminuir a complexidade dos painéis causada pelo grande aumento de informação disponível nas salas de controle das centrais nucleares. Neste trabalho foi desenvolvido um Sistema de Monitoração e Diagnóstico utilizando a metodologia GMDH (Group Method of Data Handling) aplicado ao reator de pesquisas do Ipen IEA-R1. O sistema faz a monitoração, comparando os valores calculados pelo modelo GMDH com os valores medidos. A metodologia desenvolvida foi aplicada inicialmente em modelos teóricos: um modelo teórico de trocador de calor e um modelo teórico do reator IEA-R1. Os resultados obtidos com os modelos teóricos propiciaram uma base para a aplicação da metodologia aos dados de operação do reator. Para a monitoração de dados de operação foram desenvolvidos três modelos GMDH: o primeiro utilizou apenas variáveis de processo, o segundo modelo foi desenvolvido considerando-se algumas variáveis nucleares e três variáveis de temperatura, e o terceiro modelo GMDH considerou todas as variáveis possíveis. Os três modelos apresentaram resultados excelentes, mostrando amplamente a viabilidade da utilização da metodologia GMDH na monitoração de dados de operação. A comparação entre os resultados dos três modelos desenvolvidos mostrou ainda a capacidade da metodologia GMDH de escolher as melhores variáveis para otimização do modelo. Para a implementação de um sistema de diagnóstico, foram adicionadas falhas sinteticamente aos valores das variáveis de temperatura. Os valores de falhas correspondem a uma descalibração da temperatura e o resultado da monitoração de dados com falhas foi utilizado para a elaboração de um sistema de diagnóstico simples e objetivo baseado na lógica nebulosa.

    Palavras-Chave: accuracy; computerized simulation; data acquisition systems; experimental data; fuzzy logic; g codes; heat exchangers; iear-1 reactor; m codes; neural networks; optimization; reactor monitoring systems; reactor operation; temperature measurement

  • IPEN-DOC 11056

    GONCALVES, I.M. ; TING, D.K.S. ; FERREIRA, P.B. ; UPADHYAYA, B.R.. Monitoring an experimental reactor using the group method of data handling approach. Nuclear Technology, v. 149, p. 101-109, 2005.

    Palavras-Chave: reactor monitoring systems; algorithms; algebra; iear-1 reactor; experimental reactors; data acquisition systems; reactor operation

  • IPEN-DOC 10748

    BRANCACCIO, F. ; DIAS, M.S. ; KOSKINAS, M.F. . Monte Carlo simulation of a digital coincidence system applied to sup(60)Co standardization. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: beta spectra; cobalt 60; coincidence methods; computerized simulation; data acquisition systems; data analysis; digital systems; gamma spectra; monte carlo method; standardization

  • IPEN-DOC 11956

    GENEZINI, FREDERICO A. ; RAELE, MARCUS P. ; ZAHN, GUILHERME S. ; ZAMBONI, CIBELE B. . Multiparametric coincidence measurements of sup(155)SM beta-decay. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: beta-minus decay; coincidence spectrometry; data acquisition systems; europium 155; high-purity ge detectors; linear accelerators; multi-parameter analysis; samarium 155

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.