Navegação por assunto "photodiodes"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 07092

    COSTA, F.E. ; HAMADA, M.M. . Development of a portable counter with data acquisition system for flow measurements, using radioactive tracers. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; radioisotopes; fluid flow; pulses; data acquisition systems; cesium iodides; thallium; photodiodes; industrial plants

  • IPEN-DOC 09093

    COSTA, F.E. ; HAMADA, M.M. . Development of a scintillator detector set with counter and data acquisition for flow measurements. Nuclear Instruments and Methods in Physics Research, v. 486, n. 1/2, Section A, p. 150-155, 2002.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; cesium iodides; thallium; photodiodes; fluid flow; data acquisition systems; pulses

  • IPEN-DOC 09071

    COSTA, F.E. ; HAMADA, M.M. . Development of a scintillator detector set with counter and data acquisition for flow measurements. In: AUFFRAY, E. (Ed.); CHIPAUX, R. (Ed.); LECOQ, P. (Ed.); PEDRINI, C. (Ed.); SCHNEEGANS, M. (Ed.) INTERNATIONAL CONFERENCE ON INORGANIC SCIN TILLATORS AND THEIR USE IN SCIENTIFIC AND INDUSTRIAL APPLICATIONS, 6th, Sept. 16-21, 2001, Chamonix, France. Proceedings... 2001. p. 150-155.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; cesium iodides; thallium; photodiodes; fluid flow; data acquisition systems; pulses

  • IPEN-DOC 09253

    MESQUITA, C.H. ; MADI FILHO, T. ; HAMADA, M.M. . Development of neutron detector using the PIN photodiode with polyethylene (n,p) converter. IEEE Transactions on Nuclear Science, v. 50, n. 4, Part 1, p. 1170-1174, 2003.

    Palavras-Chave: neutron detectors; photodiodes; si semiconductor detectors; polyethylenes; films; thickness; mathematical models; experimental data

  • IPEN-DOC 09252

    MESQUITA, C.H. ; MADI FILHO, T. ; HAMADA, M.M. . Development of neutron detector using the PIN photodiode with polyethylene (n,p) converter. In: 2002 NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGINING CONFERENCE, Nov. 10-16, 2002, Norfolk, VA, USA. Proceedings... Piscataway, NJ: IEEE, 2003, 2002. p. 416-419.

    Observação: arquivo não disponível no Repositório

    Palavras-Chave: neutron detectors; photodiodes; si semiconductor detectors; polyethylenes; films; thickness; mathematical models; experimental data

  • IPEN-DOC 05295

    BUENO, C.C. ; SANTOS, M.D.S.; GONCALVES, J.A.C. . Efeito da temperatura na resolucao de diodos PIN em espectroscopia de particulas alfa. In: 16a. REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 8-12 de setembro, 1993, Serra Negra, SP. Resumo... 1993. p. 81.

    Palavras-Chave: photodiodes; silicon; alpha spectroscopy

  • IPEN-DOC 27286

    PEREIRA, SAULO de T. . Efeitos de uma única irradiação de luz de baixa potência em camundongos portadores de tumor de mama / Effects of a single low-power light irradiation in mice with breast tumor . 2019. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 72 p. Orientador: Martha Simões Ribeiro. DOI: 10.11606/D.85.2019.tde-21092020-100052

    Abstract: A fotobiomodulação (FBM) vem sendo utilizada nas áreas da Saúde como estratégia terapêutica para doenças de etiologias variadas. No entanto, seus efeitos em células tumorais ainda não são bem elucidados, gerando controvérsias sobre sua utilização na prática clínica. O objetivo deste trabalho é avaliar os efeitos da FBM em tumor de mama in vitro e em modelo animal. In vitro, nós verificamos a ação da FBM na viabilidade de células de tumor de mama de linhagem murino (4T1) em condições de normoxia e hipóxia. In vivo, as células foram inoculadas em camundongos. Após indução do tumor, o seu volume foi acompanhado diariamente com um paquímetro digital.Quando o tumor atingiu 100 mm3, o tratamento foi iniciado. Para a FBM, foi utilizado um LED na região do vermelho (660 ±20nm) com irradiância de 24,3 mW/cm2. Os animais foram aleatoriamente divididos em grupos onde cada grupo recebeu uma dose de energia diferente: G0 (não recebeu irradiação), G1 (1,2 J), G3 (3,6 J) e G6 (6 J). Após a irradiação, dados como volume tumoral, nível de plaquetas e células brancas e vermelhas, foram acompanhados durante 3 semanas após tratamento para a obtenção de dados estatísticos. Os dados mostram que as células irradiadas com a energia de 6 J apresentaram significativaredução na viabilidade celular em condições de normoxia. Para o experimento in vivo, os grupos irradiados têm uma sobrevida maior em relação ao grupo controle, embora não tenham sido observadas diferenças significativas entre os grupos com relação ao volume tumoral. Em relação ao hemograma, não foram observadas diferenças significativas entre os grupos com relação ao número total de células brancas, vermelhas e plaquetas.

    Palavras-Chave: neoplasms; tumor cells; anoxia; hysteresis; photodiodes; light emitting diodes; low level counters; laser radiation; infrared divergences; therapy; blood cells; survival curves; biological effects; mice; in vivo; in vitro

  • IPEN-DOC 24157

    COSTA, PRISCILA ; COSTA, FABIO E. ; RAELE, MARCUS P. ; ZAHN, GUILHERME S. ; GERALDO, BIANCA ; VIEIRA JUNIOR, NILSON D. ; SAMAD, RICARDO E. ; GENEZINI, FREDERICO A. . Eletronic response of a photodiode coupled to a boron thin film. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A portable thermal neutron detector is proposed in this work using a silicon photodiode coupled to a boron thin film. The aim of this work was to verify the effect in the electronic response of this specific photodiode due to boron deposition, since the direct deposition of boron in the semiconductor surface could affect its electrical properties specifically the p-type layer that affects directly the depletion region of the semiconductor reducing the neutron detector efficiency count. Three boron depositions with different thickness were performed in the photodiode (S3590-09) surface by pulsed laser deposition and the photodiode was characterized, before and after the deposition process, using a radioactive americium source. Energy spectra were used to verify the electronic response of the photodiode, due to the fact that it is possible to relate it to the photopeak pulse height and resolution. Spectra from the photodiode without and with boron film deposition were compared and a standard photodiode (S3590-04) that had the electronic signal conserved was used as reference to the pulse height for electronics adjustments. The photopeak energy resolution for the photodiode without boron layer was 10.26%. For the photodiode with boron deposition at different thicknesses, the resolution was: 7.64 % (0.14 μm), 7.30 % (0.44 μm) and 6.80 % (0.63 μm). From these results it is possible to evaluate that there was not any degradation in the silicon photodiode.

    Palavras-Chave: americium 241; boron; electrical properties; energy spectra; brazilian cnen; neutron detectors; photodiodes; portable equipment; thermal neutrons; thin films

  • IPEN-DOC 24575

    COSTA, P. ; COSTA, F.E. ; RAELE, M.P. ; ZAHN, G. ; GERALDO, B. ; VIEIRA JUNIOR, N.D. ; SAMAD, R.E. ; GENEZINI, F.A. . Eletronic response of photodiode coupled to a boron thin film. In: 60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORS, November 28 - December 01, 2017, São Paulo, SP. Abstract... São Paulo, SP: Instituto de Pesquisas Energéticas e Nucleares, 2017. p. 56-56.

    Abstract: A portable thermal neutron detector is proposed using a silicon photodiode coupled to a boron thin film. The aim of this work was to verify the effect in the electronic response of this specific photodiode due to boron deposition, since the direct deposition of boron in the semiconductor surface could affect its electrical properties specifically the p-type layer that affects directly the depletion region of the semiconductor reducing the neutron detector efficiency count. Three boron depositions with different thickness were performed in the photodiode (S3590-09) surface by pulsed laser deposition and the photodiode was characterized, before and after the deposition process, using a radioactive americium source. Energy spectra were used to verify the electronic response of the photodiode, due to the fact that it is possible to relate it to the photopeak pulse height and resolution. Spectra from the photodiode without and with boron film deposition were compared and a standard photodiode (S3590-04) that had the electronic signal conserved was used as reference to the pulse height for electronics adjustments. The photopeak energy resolution for the photodiode without boron layer was 10.26%. For the photodiode with boron deposition at different thicknesses, the resolution was: 7.64% (0.14 m), 7.30% (0.44 m) and 6.80% (0.63 m). From these results it is possible to evaluate that there was not any degradation in the silicon photodiode.

    Palavras-Chave: americium 241; boron; electrical properties; energy spectra; neutron detectors; photodiodes; portable equipment; thermal neutrons; thin films; brazilian cnen

  • IPEN-DOC 02705

    BUENO, C.C. ; GONCALVES, J.A.C. ; SANTOS, M.D.S.. Espectrometria de particulas carregadas com fotodiodos de Si. In: 3o. ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7-11 de agosto, 1995, Aguas de Lindoia, SP. 1995. p. 649-653.

    Palavras-Chave: silicon; photodiodes; particles; x-ray detection; x-ray spectra; radiation detectors

  • IPEN-DOC 06889

    MAGALHAES, RODRIGO R. de . Espectrometria de raios-x com diodos de Si. 2000. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 79 p. Orientador: Carmem Cecilia Bueno Tobias.

    Palavras-Chave: x-ray spectroscopy; photodiodes; silicon diodes; semiconductor detectors

  • IPEN-DOC 07802

    MAGALHAES, R.R.; BUENO, C.C. ; GONCALVES, J.A.C. ; SANTOS, M.D.S.. Espectrometria de raios-X com diodos de Si. In: REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 21., 8-12 set, 1998, Itatiaia, RJ. Resumos... 1998. p. 81-82.

    Palavras-Chave: x-ray spectroscopy; silicon diodes; photodiodes; x-ray detection

  • IPEN-DOC 09403

    COSTA, F.E. ; PEREIRA, M.C.C. ; HAMADA, M.M. . Espectrometro de energia portatil utilizando detector de CsI(Tl) com fotodiodo. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 2, p. 1271-1274, 2002.

    Palavras-Chave: gamma spectrometers; scintillation counters; cesium iodides; crystals; photodiodes; computer output devices

  • IPEN-DOC 08800

    COSTA, F.E. ; PEREIRA, M.C.C. ; HAMADA, M.M. . Espectrometro de energia portatil utilizando detector de CsI(Tl) com fotodiodo. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: gamma spectrometers; scintillation counters; cesium iodides; crystals; photodiodes; computer output devices

  • IPEN-DOC 07246

    BUENO, C.C. ; GONCALVES, J.A.C. ; MAGALHAES, R.R.; SANTOS, M.D.S.. Espectrometro de radiacao eletromagnetica com fotodiodos de Si. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 5., 5-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: electromagnetic radiation; spectrometers; silicon; photodiodes; x-ray spectroscopy; energy resolution; americium 241

  • IPEN-DOC 04169

    HAMADA, M.M. ; MESQUITA, C.H. ; RELA, P.R. ; HASHIMOTO, T.; SHIRAISHI, F.. Estudo do desempenho da combinacao do cristal de CsI(Tl) com o fotodiodo tipo PIN. In: 4o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 5-9 de julho, 1992, Rio de Janeiro, RJ. 1992. p. 611-614.

    Palavras-Chave: cesium iodides; photodiodes

  • IPEN-DOC 04877

    PEREIRA, M.C.C. ; HAMADA, M.M. ; MADI FILHO, T. . Estudo do tempo de decaimento, resolucao energetica, transmitancia e luminescencia em cristais de iodeto de cesio ativados com talio (CsI(Tl)). In: 6o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 27 de outubro - 1 de novembro, 1996, Rio de Janeiro, RJ. 1996.

    Palavras-Chave: scintillation counters; cesium iodides; thallium; gamma radiation; detection; silicon; photodiodes; bridgman method; luminescence; decay

  • IPEN-DOC 25772

    NASCIMENTO, C.R.; ASFORA, V.K.; BARROS, V.S.M.; GONCALVES, J.A.C. ; ANDRADE, L.F.R.; KHOURY, H.J.; BUENO, C.C. . Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-9, 2019. DOI: 10.15392/bjrs.v7i2A.577

    Abstract: The response of the commercial XRA-24 PIN photodiode (5.76 mm2 active area) for clinical electron beam dosimetry covering the range of 8-12 MeV was investigated. Within this energy range, the charge generated in the diode’s sensitive volume is linearly dependent on the absorbed dose up to 320 cGy. However, charge sensitivity coefficients evidenced that the dose response of the diode is slightly dependent on the electron beam energy. Indeed, the diode’s energy dependence was within 8.5% for 8-12 MeV electron beams. On the other hand, it was also observed an excellent repeatability of these results with a variation coefficient (VC) lower than 0.4%, which is within the 1% tolerance limit recommended by the AAPM TG-62. Furthermore, the agreement between the percentage depth dose profiles (PDD) gathered with the diode and the ionization chamber allowed achieving the electron beam quality within 1% of that obtained with the ionization chamber. Based on these results, the photodiode XRA-24 can be a reliable and inexpensive alternative for electron beams dosimetry.

    Palavras-Chave: dosimetry; electron beams; feasibility studies; ionization chambers; photodiodes; depth dose distributions; energy dependence; mev range 01-10; silicon diodes

  • IPEN-DOC 24059

    NASCIMENTO, CRISTINA R.; ASFORA, VIVIANE K.; BARROS, VINICIUS S.M.; GONÇALVES, JOSEMARY A.C. ; ANDRADE, LUCAS F.R.; KHOURY, HELEN J.; BUENO, CARMEN C. . Feasibility studies of using thin entrance window photodiodes for clinical electron beam dosimetry. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The response of the commercial XRA-24 PIN photodiode (5.76 mm2 active area) for clinical electron beam dosimetry covering the range of 8-12 MeV was investigated. Within this energy range, the charge generated in the diode’s sensitive volume is linearly dependent on the absorbed dose up to 320 cGy. However, charge sensitivity coefficients evidenced that the dose response of the diode is slightly dependent on the electron beam energy. Indeed, the diode’s energy dependence was within 8.5% for 8-12MeV electron beams. On the other hand, it was also observed an excellent repeatability of these results with a variation coefficient (VC) lower than 0.4%, which is within the 1% tolerance limit recommended by the AAPM TG-62. Furthermore, the agreement between the percentage depth dose profiles (PDD) gathered with the diode and the ionization chamber allowed achieving the electron beam quality within 1% of that obtained with the ionization chamber. Based on these results, the photodiode XRA-24 can be a reliable and inexpensive alternative for electron beams dosimetry.

    Palavras-Chave: depth dose distributions; electron beams; energy dependence; feasibility studies; ionization chambers; mev range 01-10; photodiodes; silicon diodes

  • IPEN-DOC 07849

    MAGALHAES, R.R.; BUENO, C.C. ; GONCALVES, J.A.C. ; SANTOS, M.D.S.. Influencia do ruido eletronico em sistemas de espectrometria de raios-X com diodos de Si. In: REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 22., 8-12 set, 1999, Sao Lourenco, MG. Resumos... 1999. p. 62-63.

    Palavras-Chave: x-ray spectroscopy; semiconductor detectors; silicon diodes; photodiodes; noise; preamplifiers; temperature dependence

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.