Navegação por assunto "portable equipment"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 26296

    SOMESSARI, SAMIR L. ; FEHER, ANSELMO ; SPRENGER, FRANCISCO E. ; DUARTE, CELINA L. ; SAMPA, MARIA H. de O. ; OMI, NELSON M. ; GASPER, RENATO R. ; LAINETTI, FABIANA ; FUGA, DANILO F.; RODRIGUES, MARCOS; CALVO, WILSON A.P. . Development of a mobile unit with an electron beam accelerator (20 kw and 700 keV). In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2628-2637.

    Abstract: The purpose of the present study is therefore to install an electron beam accelerator (20 kW and 700 keV) in a mobile unit to treat effluent from petroleum production, for petroleum desulfurization and, in addition, for degradation of toxic organic compounds in wastewater for reusein, in partnerships with private and public institutions. Several technical aspects were considered in this installation, such as following the national transport legislation and the safety requirements (BSS, IAEA and CNEN Safety Standards). Technical characteristics of the electron beam accelerator (EBA) are energy of 700 keV and 28.5 mA of beam current, with 60 cm scan length. The installation of the EBA includes the developing and manufacturing a radiological shield. In several points of the mobile unit, GM type radiation sensors will be installed for radiological monitoring during irradiation processing, interlocked with the accelerator’s safe operating system. For the design of a vacuum system with mechanical pumps, ion pump and sensors, the following procedures will be carried out: a) design of an optimized system of the mobile unit power supply; b) development of a cooling system with deionized water and pressurized air for the cooling of the EBA systems in the scan horn, high voltage generator, control panel, vacuum system, among other peripherals; c) installation of the fan to cool the thin titanium window; d) installation of an ozone filter in the exhaust system to remove gas generated during irradiation; e) project of a mechanical structural reinforcement of the trailer was studied, improved and executed. In the mobile unit, a space was created for an analysis laboratory to monitor the wastewater before and after irradiation, establishing parameters in the quality control of the irradiated material.

    Palavras-Chave: accelerators; decomposition; desulfurization; electron beams; organic compounds; petroleum industry; portable equipment; radiation protection; safety standards; waste water

  • IPEN-DOC 07092

    COSTA, F.E. ; HAMADA, M.M. . Development of a portable counter with data acquisition system for flow measurements, using radioactive tracers. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; radioisotopes; fluid flow; pulses; data acquisition systems; cesium iodides; thallium; photodiodes; industrial plants

  • IPEN-DOC 09093

    COSTA, F.E. ; HAMADA, M.M. . Development of a scintillator detector set with counter and data acquisition for flow measurements. Nuclear Instruments and Methods in Physics Research, v. 486, n. 1/2, Section A, p. 150-155, 2002.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; cesium iodides; thallium; photodiodes; fluid flow; data acquisition systems; pulses

  • IPEN-DOC 09071

    COSTA, F.E. ; HAMADA, M.M. . Development of a scintillator detector set with counter and data acquisition for flow measurements. In: AUFFRAY, E. (Ed.); CHIPAUX, R. (Ed.); LECOQ, P. (Ed.); PEDRINI, C. (Ed.); SCHNEEGANS, M. (Ed.) INTERNATIONAL CONFERENCE ON INORGANIC SCIN TILLATORS AND THEIR USE IN SCIENTIFIC AND INDUSTRIAL APPLICATIONS, 6th, Sept. 16-21, 2001, Chamonix, France. Proceedings... 2001. p. 150-155.

    Palavras-Chave: radiation detectors; scintillation counters; portable equipment; cesium iodides; thallium; photodiodes; fluid flow; data acquisition systems; pulses

  • IPEN-DOC 07251

    KODAMA, Y. ; SUZUKI, F.F. ; SANCHES, M.P. ; RODRIGUES, D.L. . Discussion on surface contamination monitoring using portable zinc sulfide scintillation detectors. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 5., 5-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: surface contamination; surface contamination monitors; scintillation counters; zinc sulfides; portable equipment; activity levels; alpha detection; radiation protection

  • IPEN-DOC 06395

    POTIENS, M.P.A. ; CALDAS, L.V.E. ; PANZER, W.. Dosimetric basis for a calibration protocol of survey meters for diagnostic radiology. In: 4o. CONGRESO REGIONAL DE SEGURIDAD RADIOLOGICA Y NUCLEAR, 19-23 de octubre, 1998, La Habana, Cuba. 1998. p. 6.39-6.42.

    Palavras-Chave: radiation detectors; portable equipment; calibration; dosimetry; diagnostic techniques; radiology

  • IPEN-DOC 24157

    COSTA, PRISCILA ; COSTA, FABIO E. ; RAELE, MARCUS P. ; ZAHN, GUILHERME S. ; GERALDO, BIANCA ; VIEIRA JUNIOR, NILSON D. ; SAMAD, RICARDO E. ; GENEZINI, FREDERICO A. . Eletronic response of a photodiode coupled to a boron thin film. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A portable thermal neutron detector is proposed in this work using a silicon photodiode coupled to a boron thin film. The aim of this work was to verify the effect in the electronic response of this specific photodiode due to boron deposition, since the direct deposition of boron in the semiconductor surface could affect its electrical properties specifically the p-type layer that affects directly the depletion region of the semiconductor reducing the neutron detector efficiency count. Three boron depositions with different thickness were performed in the photodiode (S3590-09) surface by pulsed laser deposition and the photodiode was characterized, before and after the deposition process, using a radioactive americium source. Energy spectra were used to verify the electronic response of the photodiode, due to the fact that it is possible to relate it to the photopeak pulse height and resolution. Spectra from the photodiode without and with boron film deposition were compared and a standard photodiode (S3590-04) that had the electronic signal conserved was used as reference to the pulse height for electronics adjustments. The photopeak energy resolution for the photodiode without boron layer was 10.26%. For the photodiode with boron deposition at different thicknesses, the resolution was: 7.64 % (0.14 μm), 7.30 % (0.44 μm) and 6.80 % (0.63 μm). From these results it is possible to evaluate that there was not any degradation in the silicon photodiode.

    Palavras-Chave: americium 241; boron; electrical properties; energy spectra; brazilian cnen; neutron detectors; photodiodes; portable equipment; thermal neutrons; thin films

  • IPEN-DOC 24575

    COSTA, P. ; COSTA, F.E. ; RAELE, M.P. ; ZAHN, G. ; GERALDO, B. ; VIEIRA JUNIOR, N.D. ; SAMAD, R.E. ; GENEZINI, F.A. . Eletronic response of photodiode coupled to a boron thin film. In: 60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORS, November 28 - December 01, 2017, São Paulo, SP. Abstract... São Paulo, SP: Instituto de Pesquisas Energéticas e Nucleares, 2017. p. 56-56.

    Abstract: A portable thermal neutron detector is proposed using a silicon photodiode coupled to a boron thin film. The aim of this work was to verify the effect in the electronic response of this specific photodiode due to boron deposition, since the direct deposition of boron in the semiconductor surface could affect its electrical properties specifically the p-type layer that affects directly the depletion region of the semiconductor reducing the neutron detector efficiency count. Three boron depositions with different thickness were performed in the photodiode (S3590-09) surface by pulsed laser deposition and the photodiode was characterized, before and after the deposition process, using a radioactive americium source. Energy spectra were used to verify the electronic response of the photodiode, due to the fact that it is possible to relate it to the photopeak pulse height and resolution. Spectra from the photodiode without and with boron film deposition were compared and a standard photodiode (S3590-04) that had the electronic signal conserved was used as reference to the pulse height for electronics adjustments. The photopeak energy resolution for the photodiode without boron layer was 10.26%. For the photodiode with boron deposition at different thicknesses, the resolution was: 7.64% (0.14 m), 7.30% (0.44 m) and 6.80% (0.63 m). From these results it is possible to evaluate that there was not any degradation in the silicon photodiode.

    Palavras-Chave: americium 241; boron; electrical properties; energy spectra; neutron detectors; photodiodes; portable equipment; thermal neutrons; thin films; brazilian cnen

  • IPEN-DOC 07244

    VIVOLO, V. ; CALDAS, L.V.E. . Estudo das caracteristicas de monitores portateis de radiacao gama. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 5., 5-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: radiation detectors; portable equipment; performance; gamma radiation; radiation monitoring; geiger-mueller counters; ionization chambers; scintillation counters; energy dependence; electric potential

  • IPEN-DOC 07098

    VIVOLO, V. ; CALDAS, L.V.E. . Estudo das caracteristicas operacionais e de seguranca de monitores portateis de radiacao gama. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: radiation detectors; radiation monitors; portable equipment; gamma radiation; performance testing; geiger-mueller counters; ionization chambers; scintillation counters

  • IPEN-DOC 11584

    RELA, CAROLINA S. . Estudo de viabilidade técnica e econômica para implementação de uma unidade móvel para tratamento de efluentes industriais com feixe de elétrons. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Margarida Mizue Hamada. DOI: 10.11606/D.85.2006.tde-16052012-091709

    Abstract: O tratamento de efluentes industriais é uma prática que vem se disseminando em ritmo acelerado, porque além de contribuir para reforçar a imagem pública, através do combate à poluição, ela traz vantagens econômicas para as empresas que podem reutilizar a água tratada do efluente em seus próprios processos. A técnica de tratamento estudada no presente trabalho é a que utiliza a oxidação/redução química destacando-se a utilização da radiação ionizante por meio de feixes de elétrons. Esta técnica utiliza um processo oxidativo avançado, gerando radicais altamente reativos que provocam a oxidação, redução, dissociação e degradação em compostos orgânicos e exercendo efeito letal nos microorganismos, protozoários e parasitas em geral. Neste trabalho desenvolveu-se um projeto conceituai e básico de uma unidade móvel de tratamento de efluentes utilizando radiação ionizante, fazendo com que a unidade se desloque até o ponto de tratamento, facilitando assim a logística. Em seguida, elaborou-se um estudo de viabilidade técnica e econômica permitindo dados consistentes sobre a capacidade e custo de processamento de efluentes e valores consolidados dos investimentos necessários para serem apresentados a órgãos financiadores para a construção de uma unidade móvel. Os resultados dos estudos demonstram que é viável tecnicamente a construção de uma unidade móvel, pois atende a legislação pertinente do Brasil, nos aspectos de Radioproteção e limite de transporte de carga. O custo unitário do processamento mostrou-se superior ao de uma unidade fixa em razão da diminuição da eficiência da interação da radiação incidente no efluente processado, devido à redução de energia do acelerador de elétrons e da disponibilidade de operação da unidade.

    Palavras-Chave: accelerators; investment; portable equipment; industrial wastes; irradiation; electron beams; liquid wastes; waste processing; chemical effluents

  • IPEN-DOC 12403

    AFONSO, LUCIANA C.; POTIENS, MARIA da P.A. ; CALDAS, LINDA V.E. . Estudo do comportamento dos feixes de um irradiador gama (sup(137Cs e sup(60)Co a curtas distancias. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 12., 6-9 de jun., 2007, Foz do Iguacu, PR. Resumo... 2007.

    Palavras-Chave: gamma radiation; dosimetry; calibration; radiation monitors; portable equipment

  • IPEN-DOC 26307

    ALMEIDA, MATEUS R. de ; ZAMBONI, CIBELE B. ; SILVA, DALTON G.N. da ; AZEVEDO, MARIA R.. Evaluation of iron in blood of athletes by the EDXRF technique. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2865-2868.

    Abstract: The aim of this study was evaluate Fe in blood of athletes from different modalities (judo athletes, cyclist and long distance runners) by X-ray Fluorescence methodology using portable equipment, as an alternative for clinical practice. The study showed the practicality and efficacy of using this methodology for successive clinical evaluations, during the preparation period of competitions, providing data that help in the elaboration of a balanced diet, as well as contribute to the proposal of new clinical evaluation protocols. In addition, the results emphasize the need to adopt differentiated diets for adequate iron intake as a function of sports activity.

    Palavras-Chave: blood; clinical trials; concentration ratio; efficiency; iron; nutritional deficiency; portable equipment; x-ray fluorescence analysis

  • IPEN-DOC 12130

    POTIENS, MARIA da P.A. ; LUCENA, RODRIGO F.; SANTOS, GELSON P. ; VIVOLO, VITOR . Improvement of gamma calibration procedures with commecial management software. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... São Paulo: ABEN, 2007, 2007.

    Palavras-Chave: a codes; air; calibration; cesium 137; cobalt 60; data covariances; experimental data; gamma radiation; iso; kerma; laboratory equipment; portable equipment; radiation sources

  • IPEN-DOC 20000

    ALVARENGA, TALLYSON S. . Instalação e caracterização básica de um laboratório para testes de monitores portáteis com radiação de nêutrons / Installation and basic characterization of a laboratory for testing of portable monitors with neutron radiation . 2014. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 81 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2014.tde-16062014-155542

    Abstract: Foi realizada a implantação de um laboratório para testes de detectores com radiação de nêutrons. Uma sala foi reformada e adaptada para ser o Laboratório de TestescomNêutrons(LTN) no subsolo do prédio do Laboratório de Calibração de Instrumentos do IPEN. Foi criada uma sala de controle do sistema de exposição e posicionamento da fonte e para o operador responsável pelos procedimentos de testes dos instrumentos. Foi desenvolvida uma blindagem adequada para a fonte de 241Am(Be), previamente calibrada no Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), num sistema padrão primário. Um arranjo de irradiação automatizado foi implantado, possibilitando a variação da distância fonte-detector por meio de um comando à distância por um painel eletrônico localizado na sala de controle. Os resultados obtidos do levantamento radiométrico permitiram avaliar as condições existentes no LTN e a sua classificação. Foi realizado um estudo de estabilidade a curto e a médio prazo da resposta de vários detectores de nêutrons, que apresentaram resultados dentro do limite recomendado pela norma internacional. A influência da radiação espalhada foi determinada por duas técnicas: Método de Monte Carlo e método experimental, com a utilização de um cone de sombra e um detector de radiação de nêutrons portátil calibrado no LNMRI. Alguns monitores portáteis foram testados no arranjo estabelecido. Dos resultados obtidos por meio da simulação foi possível concluir que a estrutura do LTN está em concordância com os resultados obtidos em outros laboratórios que oferecem o mesmoserviço.

    Palavras-Chave: brazilian cnen; laboratories; testing; radiation detectors; neutron detection; neutron monitors; portable equipment; radiation monitors; monte carlo method

  • IPEN-DOC 07084

    MANZOLI, J.E. ; POTIENS, M.P.A. . Irradiacao gama no Laboratorio de Calibracao do IPEN para fins de calibracao em radioprotecao. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: radiation detectors; portable equipment; calibration; gamma radiation; irradiation; radiation quality; radiation protection

  • IPEN-DOC 22466

    DAMATTO, WILLIAN B. ; POTIENS, MARIA da P.A. ; VIVOLO, VITOR . Portable meter study of ionizing radiation teletector in high rates of air kerma. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 2 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: air; brazilian cnen; calibration standards; energy dependence; ionizing radiations; kerma; meters; portable equipment; quality control; radiation monitors; radiation protection; testing

  • IPEN-DOC 21080

    DAMATTO, WILLIAN B. ; POTIENS, MARIA da P.A. ; VIVOLO, VITOR . Portable radiation meters evaluation in high rates of air kerma. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: air; kerma; portable equipment; calibration; dose rates; dosimetry; ionizing radiations; meters; monitors; quality control; performance testing

  • IPEN-DOC 17578

    FUKUMORI, NEUZA T.O. ; CAMPOS, DOMINGOS G. de ; MASSICANO, ADRIANA V.F.; PEREIRA, NILDA P.S. de ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . A portable test system for determination of bacterial endotoxins in sup(18)F-FDG, sup(99m)Tc, and lyophilized reagents for labeling with sup(99m)Tc. Journal of Nuclear Medicine Technology, v. 39, p. 121-124, 2011. DOI: 10.2967/jnmt.110.081380

    Palavras-Chave: bacteria; endotoxins; testing; portable equipment; fluorine 18; fluorodeoxyglucose; technetium 99; labelling; lyophilization; radiopharmaceuticals

  • IPEN-DOC 22773

    VELO, A.F. ; HAMADA, M.M. ; CARVALHO, D.V.S. ; MARTINS, J.F.T. ; MESQUITA, C.H. . A portable tomography system with seventy detectors and five gamma-ray sources in fan beam geometry simulated by Monte Carlo method. Flow Measurement and Instrumentation, v. 53, p. 89-94, 2017. DOI: 10.1016/j.flowmeasinst.2016.09.015

    Abstract: This paper describes the Monte Carlo simulation, using MCNP4C, of a portable instant non-scanning tomography containing five radioactive sources with the same activities and seventy NaI(Tl) detectors constituted of five sets of fourteen detectors, diametrically opposite to each radioactive source. The detector was validated by comparison with the experimental measurements. The full width at half maximum (FWHM) deviation between the experimental and the simulated spectra was 3.5%. A steel pipe of 17 cm×0.5 cm (diameter×thickness) containing water and two dynamic bubbles of 2 cm and 4 cm diameter were simulated. The SIRT algorithm was used to reconstruct the images. The simulated images are presented in frames. On the first frame, no bubble is observed. On the subsequent frames, the growing of the bubbles is observed, reaching the maximum diameter; after that, the bubble begins to decrease progressively, until its disappearance. The measured bubble diameters generated by simulation were 43 ± 3 mm and 27 ± 2 mm for the bubbles of 40 mm and 20 mm diameters, respectively. The spatial resolution of the proposed simulated tomography was estimated by the Modulation Transfer Function (MTF), presenting a spatial resolution of 18.3 mm and 20.2 mm for samplings at 137Cs photopeak and full window, respectively.

    Palavras-Chave: monte carlo method; tomography; portable equipment; industrial plants; images; simulation

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.