JavaScript is disabled for your browser. Some features of this site may not work without it.
Navegação por assunto "absorbed radiation doses"
-
FONSECA, GABRIEL P.
; YORIYAZ, HELIO
.
Experimentos de medidas de doses absorvidas com dosimetros termoluminescentes do tipo LiF-100 para uso clínico em radioterapia com feixes de elétrons.
In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 12.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 3.,
9-10 de novembro, 2006,
São Paulo, SP.
Resumo expandido...
2006.
p. 125-126.
Palavras-Chave:
experimental data;
dosemeters;
absorbed radiation doses;
thermoluminescent dosimetry;
lithium fluorides;
radiotherapy;
electron beams
FONSECA, GABRIEL P.; YORIYAZ, HELIO.
Experimentos de medidas de doses absorvidas com dosimetros termoluminescentes do tipo LiF-100 para uso clínico em radioterapia com feixes de elétrons.
In:
PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 12.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 3.,
9-10 de novembro, 2006,
São Paulo, SP.
Resumo expandido...
2006.
p. 125-126.
Disponível em: http://repositorio.ipen.br/handle/123456789/26042. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FONSECA, GABRIEL P.
; YORIYAZ, HELIO
.
Experimentos de medidas de doses absorvidas com dosimetros termoluminescentes do tipo LiF-100 para uso clínico em radioterapia com feixes de elétrons.
In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 13.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 4.,
29-30 de agosto, 2007,
São Paulo, SP.
Resumo expandido...
2007.
Palavras-Chave:
experimental data;
dosemeters;
absorbed radiation doses;
thermoluminescent dosimetry;
lithium fluorides;
radiotherapy;
electron beams
FONSECA, GABRIEL P.; YORIYAZ, HELIO.
Experimentos de medidas de doses absorvidas com dosimetros termoluminescentes do tipo LiF-100 para uso clínico em radioterapia com feixes de elétrons.
In:
PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 13.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 4.,
29-30 de agosto, 2007,
São Paulo, SP.
Resumo expandido...
2007.
Disponível em: http://repositorio.ipen.br/handle/123456789/26097. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BELLEZZO, MURILLO
; NASCIMENTO, EDUARDO do
; YORIYAZ, HELIO
.
A GPU-based Monte Carlo dose calculation code for photon transport in a voxel phanton.
In: INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY , 14th,
April 13-16, 2014,
Cusco, Peru.
Proceedings...
2014.
p. 377-390.
Palavras-Chave:
absorbed radiation doses;
c codes;
computer calculations;
dose rates;
dosimetry;
monte carlo method;
p codes;
parallel processing;
phantoms;
photon transport;
radiotherapy
BELLEZZO, MURILLO; NASCIMENTO, EDUARDO do; YORIYAZ, HELIO.
A GPU-based Monte Carlo dose calculation code for photon transport in a voxel phanton.
In:
INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY , 14th,
April 13-16, 2014,
Cusco, Peru.
Proceedings...
2014.
p. 377-390.
Disponível em: http://repositorio.ipen.br/handle/123456789/23567. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BRANT, ANTONIO J.C.
; NAIME, NATALIA
; LUGAO, ADEMAR B.
; PONCE, PATRICIA
.
Influence of ionizing radiation on biodegradable foam trays for food packaging obtained from irradiated cassava starch.
Brazilian Archives of Biology and Technology,
v. 61,
n. e18160520,
2018.
DOI:
10.1590/1678-4324-2018160520
Abstract:
Biodegradable polymers, such as starch, cellulose, and derivatives thereof, are being studied to produce innovative packaging in the most diverse shapes (films, bags, trays, bottles, etc.) to attend this current market trend. The aim of this work was to produce foam trays from cassava starch for food packaging via extrusion followed by thermoforming process. Their formulations were based on unirradiated and γ-irradiated starches at diverse radiation absorbed doses (in kGy) in order to evaluate the influence of the irradiated starches on the physical properties of the trays. Water absorption results showed an irregular increase with the increase of the absorbed dose ( for example, 26.32% and 39.84% for the trays based on unirradiated starch 0 kGy and 1:1 (w/w) mixture of starches 0 kGy and 100.0 kGy, respectively). Other physicochemical properties were evaluated from the starches utilized and the trays obtained. Aerobic biodegradation of the foams by mass loss also was checked in soil burial test.
Palavras-Chave:
ionizing radiations;
gamma radiation;
cassava;
starch;
packaging;
biodegradation;
compression strength;
physical properties;
hot pressing;
foams;
absorbed radiation doses;
extrusion;
flexibility
BRANT, ANTONIO J.C.; NAIME, NATALIA; LUGAO, ADEMAR B.; PONCE, PATRICIA.
Influence of ionizing radiation on biodegradable foam trays for food packaging obtained from irradiated cassava starch.
Brazilian Archives of Biology and Technology,
v. 61,
n. e18160520,
2018.
DOI:
10.1590/1678-4324-2018160520.
Disponível em: http://repositorio.ipen.br/handle/123456789/29411. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, LUCAS N. de; SCHIMIDT, FERNANDO; ANTONIO, PATRICIA L.
; ANDREETA, MARCELLO R.B.; CALDAS, LINDA V.E.
.
Lithium borate glass for high-dose dosimetry using the UV-Vis and FTIR spectrophotometrics techniques.
In: INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 18th,
July 03-08, 2016,
Munich, Germany.
Abstract...
2016.
Palavras-Chave:
absorbed radiation doses;
dosemeters;
dosimetry;
evaluation;
fourier transformation;
glass;
infrared spectra;
irradiation;
lithium;
radiation detectors;
spectrophotometry
OLIVEIRA, LUCAS N. de; SCHIMIDT, FERNANDO; ANTONIO, PATRICIA L.; ANDREETA, MARCELLO R.B.; CALDAS, LINDA V.E.
Lithium borate glass for high-dose dosimetry using the UV-Vis and FTIR spectrophotometrics techniques.
In:
INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 18th,
July 03-08, 2016,
Munich, Germany.
Abstract...
2016.
Disponível em: http://repositorio.ipen.br/handle/123456789/27560. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, LUCAS N. de
; SCHIMIDT, FERNANDO; ANTONIO, PATRICIA L.
; ANDREETA, MARCELLO R.B.; CALDAS, LINDA V.E.
.
Lithium diborate glass for high-dose dosimetry using the UV-Vis and FTIR spectrophotometry techniques.
Radiation Measurements,
v. 106,
n. SI,
p. 225-228,
2017.
DOI:
10.1016/j.radmeas.2017.05.015
Abstract:
Glass has been used in radiation dosimetry mainly for its linear response with absorbed dose, low cost
and easy evaluation. The lithium diborate glasses were irradiated with doses from 200 Gy to 10 kGy using
a60Co Gamma-Cell system 220 and evaluated with the UV-Vis and FTIR techniques. The results indicate
that the samples present lithium diborate, linearity with the absorbed dose, usefulness as YES/NO radiation
detectors (due to their color change), low fading for time periods up to 60 days and a good
response reproducibility. In conclusion, the lithium diborate glass may be promising for dosimetry in
high doses of radiation.
Palavras-Chave:
absorbed radiation doses;
dosemeters;
dosimetry;
evaluation;
fourier transformation;
glass;
infrared spectra;
irradiation;
lithium;
radiation detectors;
spectrophotometry
OLIVEIRA, LUCAS N. de; SCHIMIDT, FERNANDO; ANTONIO, PATRICIA L.; ANDREETA, MARCELLO R.B.; CALDAS, LINDA V.E.
Lithium diborate glass for high-dose dosimetry using the UV-Vis and FTIR spectrophotometry techniques.
Radiation Measurements,
v. 106,
n. SI,
p. 225-228,
2017.
DOI:
10.1016/j.radmeas.2017.05.015.
Disponível em: http://repositorio.ipen.br/handle/123456789/28522. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SOUZA, LUIZA F.; SANTOS, WILLIAM S.
; BELINATO, WALMIR; SILVA, ROGERIO M.V.; CALDAS, LINDA V.E.
; SOUZA, DIVANIZIA N..
Mass energy absorption coefficients and energy responses of magnesium tetraborate dosimeters for 0.02 MeV to 20 MeV photons using Monte Carlo simulations.
Applied Radiation and Isotopes,
v. 148,
p. 232-239,
2019.
DOI:
10.1016/j.apradiso.2019.04.015
Abstract:
Thermoluminescence dosimeters containing boron, such as magnesium tetraborate (MgB4O7), are of interest
because of their very high sensitivity, near tissue-equivalent absorption coefficients, low cost, easy handling, and
very large linearity range for absorbed dose. Another important parameter that should be considered when
working with thermoluminescent dosimeter (TLD) is the mass energy absorption coefficient (μen/ρ), which is a
close approximation to the energy available for production of chemical, biological and other effects associated
with exposure to ionizing radiation, therefore important in estimating dose in medical and health physics. In this
study the mass energy absorption coefficients and energy responses of undoped and some doped magnesium
tetraborates were calculated by Monte Carlo N-particle transport code for a range of photon energies between
20 keV and 20 MeV. The calculated parameters for MgB4O7, MgB4O7:Dy and MgB4O7:Dy,Li were evaluated in
comparison with standard TLDs as Al2O3:C and TLD-100 (LiF: Mg, Ti) and ICRU tissue data. The influence of the
dopant concentration in the MgB4O7 matrix on the energy dependence of TLD was also investigated. The analyses
indicated a good agreement between the simulations and theoretical calculations. The μen/ρ and energy
dependence of the materials are higher in the low energy range (E < 100 keV), which is related to the high
probability of interaction between radiation and matter due to photoelectric absorption. With regard to the
influence of dysprosium concentration in the MgB4O7 matrix an increase in the energy dependence of MgB4O7
for higher concentrations of dopants was observed in the low energy range.
Palavras-Chave:
absorbed radiation doses;
borates;
boron;
computerized simulation;
concentration ratio;
doped materials;
energy absorption;
energy dependence;
icru;
ionizing radiations;
kev range;
lithium fluorides;
magnesium;
magnesium compounds;
mev range;
monte carlo method;
radiation protection;
sensitivity;
thermoluminescent dosemeters
SOUZA, LUIZA F.; SANTOS, WILLIAM S.; BELINATO, WALMIR; SILVA, ROGERIO M.V.; CALDAS, LINDA V.E.; SOUZA, DIVANIZIA N.
Mass energy absorption coefficients and energy responses of magnesium tetraborate dosimeters for 0.02 MeV to 20 MeV photons using Monte Carlo simulations.
Applied Radiation and Isotopes,
v. 148,
p. 232-239,
2019.
DOI:
10.1016/j.apradiso.2019.04.015.
Disponível em: http://repositorio.ipen.br/handle/123456789/30448. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
POLO, IVON O.
; SANTOS, WILLIAM S.
; CALDAS, LINDA V.E.
.
Modelling the absorbed dose rate of the beta standard BSS2 147Pm source.
Applied Radiation and Isotopes,
v. 140,
p. 83-86,
2018.
DOI:
10.1016/j.apradiso.2018.06.015
Abstract:
The dosimetric measurements of 147Pm beta radiation beams have limitations due to their low energy, low dose
rate, great dispersion and attenuation in air or tissue. In this work, the Monte Carlo model was developed for a
147Pm absorbed dose rate determination. This model consists of an extrapolation chamber and a 147Pm beta
radiation source. Moreover, the absorbed dose rate was determined by experimental measurements and the
MCNP Monte Carlo code was used. The relative number of particles that crossed the radioactive source window
and the particles that crossed the extrapolation chamber entrance window were determined. The source fluence
spectrum was also determined. The results of the simulation and the experimental calculations are in agreement
with the absorbed dose rate from the PTB calibration certificate. The results obtained are considered acceptable,
and they agree within the uncertainties. The difference between the experimental result and that from the Monte
Carlo model, compared to that from the calibration certificate, was only 0.8% in both cases.
Palavras-Chave:
absorbed radiation doses;
beta sources;
dose rates;
extrapolation chambers;
monte carlo method;
promethium 147;
simulation
POLO, IVON O.; SANTOS, WILLIAM S.; CALDAS, LINDA V.E.
Modelling the absorbed dose rate of the beta standard BSS2 147Pm source.
Applied Radiation and Isotopes,
v. 140,
p. 83-86,
2018.
DOI:
10.1016/j.apradiso.2018.06.015.
Disponível em: http://repositorio.ipen.br/handle/123456789/29338. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FONSECA, GABRIEL P.
.
Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
/ Modelagem pelo método de Monte Carlo do paciente e das complexidades dos tratamentos braquiterápicos com alta taxa de dose
.
2015.
Tese (Doutorado em Tecnologia Nuclear) -
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP,
São Paulo.
110 p.
Orientador: Helio Yoriyaz.
DOI:
10.11606/T.85.2016.tde-06012016-155103
Abstract:
Tratamentos braquiterápicos são comumente realizados conforme o relatório da American Association of Physicists in Medicine (AAPM), Task Group report TG-43U1, o qual define o formalismo para cálculo de dose absorvida na água e não considera a composição dos materiais, densidades, dimensões do paciente e o efeito dos aplicadores. Estes efeitos podem ser significantes, conforme descrito pelo recente relatório da AAPM, Task Group report TG- 186, que define diretrizes para que sistemas de planejamento modernos, capazes de considerar as complexidades descritas acima, sejam implementados. Esta tese tem como objetivo contribuir para o aumento da exatidão dos planejamentos de tratamento braquiterápicos, seguindo as recomendações do TG-186 e indo além do mesmo. Um software foi desenvolvido para integrar planejamentos de tratamento e simulações pelo método de Monte Carlo (MC); modelos acurados, CAD-Mesh, foram utilizados para representar aplicadores braquiterápicos; Grandezas utilizadas para reportar dose absorvida, Dw,m (dose para água no meio) e Dm,m (dose para o meio no meio), foram calculadas para um tratamento de cabeça e pescoço, considerando a teoria para pequenas (SCT small cavity theory) e grandes cavidades (LCT large cavity theory); a componente da dose em razão do movimento da fonte foi avaliada para tratamentos de próstata e ginecológicos. Perfis de velocidade obtidos na literatura foram utilizados; medidas de velocidade de uma fonte braquiterapica foram realizadas com uma câmera de alta taxa de aquisição. Cálculos de dose obtidos usando MC (incluindo a composição e densidade dos tecidos, ar e o aplicador) mostram sobredoses de aproximadamente 5% dentro do volume alvo, em um tratamento ginecológico, quando comparados aos resultados obtidos com um meio homogêneo de água. Por sua vez, subdoses de aproximadamente 5% foram observadas ao considerar a composição dos tecidos e regiões com ar em um tratamento intersticial de braço. Um aplicador cilíndrico oco resultou na sobredose observada no caso ginecológico, ressaltando a necessidade de modelos acurados para representar os aplicadores. Os modelos CAD-Mesh utilizados incluem um aplicador Fletcher-Williamson, com blindagem, e um balão deformável para irradiação de mama. Os resultados obtidos com estes modelos são equivalentes aos obtidos com modelos geométricos convencionais. Este recurso pode ser conveniente para aplicadores complexos e/ou quando o projeto dos aplicadores for disponibilizado pelo fabricante. Cálculos de dose, com a composição real dos tecidos humanos, podem apresentar diferenças significativas em razão da grandeza adotada. Diferenças entre Dm,m e Dw,m (SCT ou LCT) chegam a 14% em razão da composição do osso. A metodologia adotada (SCT ou LCT) resulta em diferenças de até 28% para o osso e 36% para os dentes. A componente de dose de trânsito também pode levar a diferenças significativas, uma vez que baixas velocidades ou movimentos uniformemente acelerados foram descritos na literatura. Considerando a pior condição e sem incluir nenhuma correção no tempo de parada, a dose de trânsito pode chegar a 3% da dose prescrita para um caso ginecológico, com 4 cateteres, e até 11.1% da dose prescrita para um tratamento de próstata, com 16 cateteres. A dose de trânsito para a fonte avaliada (velocidade obtida experimentalmente) não é uniformemente distribuída e pode levar a sub ou sobredoses de até 1.4% das doses comumente prescritas (310 Gy). Os tópicos estudados são relevantes para tratamentos braquiterápicos e podem contribuir para o aumento de sua acurácia. Os efeitos estudados podem ser avaliados com o uso do software, associado a um código MC, desenvolvido.
Palavras-Chave:
brachytherapy;
iridium 192;
absorbed radiation doses;
monte carlo method;
algorithms;
calculation methods;
computer codes
FONSECA, GABRIEL P.
Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy.
Orientador: Helio Yoriyaz.
2015.
110 f.
Tese (Doutorado em Tecnologia Nuclear) -
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP,
São Paulo.
DOI:
10.11606/T.85.2016.tde-06012016-155103.
Disponível em: http://repositorio.ipen.br/handle/123456789/25298. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CAVINATO, C.C.; SAKURABA, R.K.; SANTOS, E.S.; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
.
MRI evaluation optimization of Fricke Xylenol gel dosimeter irradiated with clinical photon beams.
In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 12th,
October 7-12, 2012,
Rio de Janeiro, RJ.
Abstract...
2012.
Palavras-Chave:
magnetic resonance;
chemical dosemeters;
gels;
absorbed radiation doses;
spatial resolution;
radiation dose distributions;
phantoms;
quality control
CAVINATO, C.C.; SAKURABA, R.K.; SANTOS, E.S.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.
MRI evaluation optimization of Fricke Xylenol gel dosimeter irradiated with clinical photon beams.
In:
INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 12th,
October 7-12, 2012,
Rio de Janeiro, RJ.
Abstract...
2012.
Disponível em: http://repositorio.ipen.br/handle/123456789/20562. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CAVALCANTE, FERNANDA
; PECEQUILO, BRIGITTE R.S.
.
Natural and anthropogenic radionuclides in Brazilian commercial dog food: preliminary results.
In: INTERNATIONAL CONFERENCE ON RADIOECOLOGY AND ENVIRONMENTAL RADIOACTIVITY, 3rd,
September 7-12, 2014,
Barcelona, Espanha.
Proceedings...
2014.
Palavras-Chave:
absorbed radiation doses;
americium 241;
brazil;
cats;
cesium 137;
cobalt 60;
concentration ratio;
dogs;
food;
gross domestic product;
gamma spectroscopy;
indium 100;
ingestion;
iodine 131;
nitrogen;
polyethylenes;
potassium 40;
radioecological concentration;
radionuclide kinetics;
ge semiconductor detectors
CAVALCANTE, FERNANDA; PECEQUILO, BRIGITTE R.S.
Natural and anthropogenic radionuclides in Brazilian commercial dog food: preliminary results.
In:
INTERNATIONAL CONFERENCE ON RADIOECOLOGY AND ENVIRONMENTAL RADIOACTIVITY, 3rd,
September 7-12, 2014,
Barcelona, Espanha.
Proceedings...
2014.
Disponível em: http://repositorio.ipen.br/handle/123456789/23754. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, ALINE S.G.R. de
; DAMATTO, SANDRA R.
.
Natural radioactivity and estimated dose in brazilian tobacco products.
In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 22-27, 2017,
Belo Horizonte, MG.
Proceedings...
Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear,
2017.
Abstract:
Tobacco products contain significant concentrations of natural radionuclides from 238U and 232Th series. The consumption of these products increases the internal dose of radiation due to the inhalation of the natural radionuclides. Studies from literature emphasize that tobacco products have measurable concentrations of 210Po and 210Pb, and may contribute significantly to the increase of internal radiation dose and a large number of lung cancer in smokers. The objectives of this work were to determine the concentrations (Bq/kg) of the radionuclides 226Ra, 228Ra, 210Pb and 210Po and calculate the internal doses of radiation due to the consumption of these products. In the present work 71 samples were analyzed, consisting of cigars, unflavored and flavored cigarettes, straw cigarettes, cigars and roll smoke. The samples were purchased in Brazilian popular commercial establishments. The analytical techniques employed were the gross alpha and beta measurement after radiochemical separation for the radionuclides 226Ra, 228Ra, 210Pb and alpha spectrometry for 210Po. The internal radiation doses were calculated with the activity concentrations determined and using the ICRP Publication 119 dose coefficients. An annual consumption of 3,650 kg of tobacco products was considered. The inhalation rates of each radionuclide followed the rates of the current literature. The estimated mean annual dose varied from 76 to 263μSv/y for the tobacco product studied in this work.
Palavras-Chave:
absorbed radiation doses;
activity levels;
alpha decay;
alpha spectroscopy;
beta decay;
concentration ratio;
inhalation;
natural radioactivity;
thorium 232;
tobacco products;
uranium 238
OLIVEIRA, ALINE S.G.R. de; DAMATTO, SANDRA R.
Natural radioactivity and estimated dose in brazilian tobacco products.
In:
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 22-27, 2017,
Belo Horizonte, MG.
Proceedings...
Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear,
2017.
Disponível em: http://repositorio.ipen.br/handle/123456789/28226. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FONSECA, LEANDRO M.
; PECEQUILO, BRIGITTE R.S.
.
Natural radioactivity in wall paints: preliminary results.
In: INTERNATIONAL NUCLEAR CHEMISTRY CONGRESS, 4th,
September 14-19, 2014,
Maresias, São Paulo.
Abstract...
2014.
Palavras-Chave:
natural radioactivity;
paints;
building materials;
radium 226;
thorium 232;
potassium 40;
absorbed radiation doses;
radiation effects
FONSECA, LEANDRO M.; PECEQUILO, BRIGITTE R.S.
Natural radioactivity in wall paints: preliminary results.
In:
INTERNATIONAL NUCLEAR CHEMISTRY CONGRESS, 4th,
September 14-19, 2014,
Maresias, São Paulo.
Abstract...
2014.
Disponível em: http://repositorio.ipen.br/handle/123456789/23758. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FUNARI, ANA P.
; ANTEBI, URI; SANTOS, LUIZ A.; VIEIRA, DANIEL P.
; MIRANDA, JURANDIR T. de; ALVES, NELSON M.; FREITAS, ANDERSON Z. de
; MATHOR, MONICA B.
.
Optical and histological evaluation in human tendon tissue sterilized by ionizing radiation.
In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 22-27, 2017,
Belo Horizonte, MG.
Proceedings...
Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear,
2017.
Abstract:
Sterilization by irradiation is a technique that is used by tissue banks aiming to eliminate contamination of human
allografts, being a safe method, free of residue and used as final sterilization. After the tissue procurement, these
undergo a series of processing stages and then are packaged and preserved by freezing. Despite aseptic care of the
material those may be subjected to sterilization in the final packing by ionizing radiation, raising the security level
of sterility of the tissue. The aim of this study was to evaluate the effects of application of ionizing radiation,
produced by 60Co source in human tendons preprocessed (A-alcohol + antibiotic; B- H2O2 + ultrasound) obtained
through collaboration with tissue banks and preserved by freezing in -80° C, the radiation absorbed doses in
processing were 12.5, 15 and 25 kGy, each one with their corresponding non-irradiated control, to examine possible
structural or morphological alterations. The irradiated samples and their controls were analyzed by means of optical
coherence tomography (OCT) and optical coherence tomography polarization sensitive (PS-OCT), and histological
tests had been stained with hematoxylin-eosin (HE). According to the results the tissue processed with
alcohol/antibiotic in conjunction with irradiation proved to be the most effective.
Palavras-Chave:
absorbed radiation doses;
alcohols;
animal tissues;
antibiotics;
cobalt 60;
freezing;
histological techniques;
ionizing radiations;
radiation effects;
sterilization;
tendons;
tomography
FUNARI, ANA P.; ANTEBI, URI; SANTOS, LUIZ A.; VIEIRA, DANIEL P.; MIRANDA, JURANDIR T. de; ALVES, NELSON M.; FREITAS, ANDERSON Z. de; MATHOR, MONICA B.
Optical and histological evaluation in human tendon tissue sterilized by ionizing radiation.
In:
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 22-27, 2017,
Belo Horizonte, MG.
Proceedings...
Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear,
2017.
Disponível em: http://repositorio.ipen.br/handle/123456789/28277. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FUNARI, ANA P.
; ANTEBI, URI; SANTOS, LUIZ A.; VIEIRA, DANIEL P.
; MIRANDA, JURANDIR T. de; ALVES, NELSON M.; FREITAS, ANDERSON Z. de
; MATHOR, MONICA B.
.
Optical and histological evaluation of human tendon tissue sterilized by ionizing radiation.
Regenerative Research,
v. 7,
n. 1,
p. 122-122,
2018.
Abstract:
Sterilization by irradiation is a technique that is used by tissue banks aiming to eliminate
contamination of human allografts, being a safe method, free of residue and used as final
sterilization. After the tissue procurement, these undergo a series of processing stages and
then are packaged and preserved by freezing. Despite aseptic care of the material those may
be subjected to sterilization in the final packing by ionizing radiation, raising the security
level of sterility of the tissue. The aim of this study was to evaluate the effects of application
of ionizing radiation, produced by 60Co source in human tendons preprocessed (A-alcohol +
antibiotic; B- H2O2 + ultrasound) obtained through collaboration with tissue banks and
preserved by freezing in -80° C, the radiation absorbed doses in processing were 12.5, 15 and
25 kGy, each one with their corresponding non-irradiated control, to examine possible
structural or morphological alterations. The irradiated samples and their controls were
analyzed by means of optical coherence tomography (OCT) and optical coherence
tomography polarization sensitive (PS-OCT), and histological tests had been stained with
hematoxylin-eosin (HE). According to the results the tissue processed with alcohol/antibiotic
in conjunction with irradiation proved to be the most effective.
Palavras-Chave:
absorbed radiation doses;
alcohols;
animal tissues;
antibiotics;
cobalt 60;
freezing;
histological techniques;
ionizing radiations;
radiation effects;
sterilization;
tendons;
tomography
FUNARI, ANA P.; ANTEBI, URI; SANTOS, LUIZ A.; VIEIRA, DANIEL P.; MIRANDA, JURANDIR T. de; ALVES, NELSON M.; FREITAS, ANDERSON Z. de; MATHOR, MONICA B.
Optical and histological evaluation of human tendon tissue sterilized by ionizing radiation.
Regenerative Research,
v. 7,
n. 1,
p. 122-122,
2018.
Disponível em: http://repositorio.ipen.br/handle/123456789/29715. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ANTUNES, PAULA C.G.
; VIJANDE, JAVIER; GIMENEZ-ALVENTOSA, VICENT; YORIYAZ, HELIO
; BALLESTER, FACUNDO.
Photon energy-fluence correction factor in low energy brachytherapy.
In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 22-27, 2017,
Belo Horizonte, MG.
Proceedings...
Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear,
2017.
Abstract:
The AAPM TG-43 brachytherapy dosimetry formalism has become a standard for brachytherapy dosimetry
worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed
dose to water at different locations. At the time of relating dose to tissue and dose to water, or vice versa, it is
usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose
in the two media can be related by their ratio of mass energy-absorption coefficients. The purpose of this work is
to study the influence of photon energy-fluence in different media and to evaluate a proposal for energy-fluence
correction factors for the conversion between dose-to-tissue ( ) tis D and dose-to-water ( ) w D .State-of-the art
Monte Carlo (MC) calculations are used to score photon fluence differential in energy in water and in various
human tissues (muscle, adipose and bone) in two different codes, MCNP and PENELOPE, which in all cases
include a realistic modeling of the 125I low-energy brachytherapy seed in order to benchmark the formalism
proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences using
the large-cavity theory. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to
tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seed is
proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue
and absorbed dose to water with an accuracy better than 0.5% in the most critical cases.
Palavras-Chave:
absorbed radiation doses;
animal tissues;
brachytherapy;
corrections;
dosimetry;
iodine 125;
monte carlo method;
p codes;
photon emission;
protons;
radiation source implants;
water
ANTUNES, PAULA C.G.; VIJANDE, JAVIER; GIMENEZ-ALVENTOSA, VICENT; YORIYAZ, HELIO; BALLESTER, FACUNDO.
Photon energy-fluence correction factor in low energy brachytherapy.
In:
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 22-27, 2017,
Belo Horizonte, MG.
Proceedings...
Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear,
2017.
Disponível em: http://repositorio.ipen.br/handle/123456789/28233. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, L.N.
; NASCIMENTO, E.O.; ANTONIO, P.L.
; CALDAS, L.V.E.
.
Plastic bottle caps as radiation detectors for high gamma radiation doses.
Brazilian Journal of Radiation Sciences,
v. 10,
n. 2A,
p. 1-18,
2022.
DOI:
10.15392/bjrs.v10i2A.1761
Abstract:
Dosimetric evaluation is indicated for material characterization seeking to identify possible
applications; still, proper preprocessing techniques are critical features of this process. This
work aimed to determine the linearity response of plastic samples irradiated with gamma
rays using the Fourier Transform Infrared (FTIR) measurements. The plastic samples were
analyzed using Derivatives and Principal Component Analysis (PCA) methods. They applied
linear and Principal Component Regression (PCR) methods to obtain linearity. The methods
obtained good results for linearity and also showed the evolution of each technique. In
conclusion, the results indicate that the applied methods can be useful in radiation physics
and for plastic samples as interesting potential radiation detectors.
Palavras-Chave:
absorbed radiation doses;
cobalt 60;
dosemeters;
dosimetry;
fourier transformation;
gamma radiation;
polyethylene terephthalate;
principal component analysis;
radiation detectors
OLIVEIRA, L.N.; NASCIMENTO, E.O.; ANTONIO, P.L.; CALDAS, L.V.E.
Plastic bottle caps as radiation detectors for high gamma radiation doses.
Brazilian Journal of Radiation Sciences,
v. 10,
n. 2A,
p. 1-18,
2022.
DOI:
10.15392/bjrs.v10i2A.1761.
Disponível em: http://repositorio.ipen.br/handle/123456789/33384. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MUNHOZ, PEDRO M.
; SILVA, LEONARDO G. de A. e
; HARADA, JULIO
; NASCIMENTO, FERNANDO C.
; CALVO, WILSON A.P.
.
Poly (butylene adipate co-terephthalate)/poly (lactic acid) (PBAT/PLA) blend characterization processed by electron beam.
In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 21-25, 2019,
Santos, SP.
Proceedings...
Rio de Janeiro: Associação Brasileira de Energia Nuclear,
2019.
p. 2510-2524.
Abstract:
The aim of this research was to check the changes in the mechanical and thermal properties of poly(butylene
adipate co-terephthalate)/poly(lactic acid) (PBAT/PLA) polymeric blend, which commercial name is Ecovio®,
after radiation processing in different absorbed doses. PBAT and PLA are biodegradable polymers and the
Ecovio® polymeric blend consists of at least 80% of polymers from renewable resources. The irradiation was
performed in a Radiation Dynamics Inc. electron beam accelerator, with 1.5 MeV of energy and electric current
of 25 mA. Samples were prepared for micrograph, mechanical and thermal analyses. These samples were
irradiated with absorbed doses of 5 kGy, 10 kGy, 15 kGy, 25 kGy and 50 kGy. The samples, after irradiation,
were submitted to experiments of ultimate strength, tensile strength, ultimate elongation, differential scanning
calorimetry (DSC) and scanning electron microscopy (SEM). The results showed a good interaction between the
components of the polymeric blends and the radiation effect on polymeric blend promoted changes in PBAT and
PLA polymers, increasing tenacity of these biopolymers and consequently facilitating yarn formation in
processing. In conclusion, these irradiated blends could be used to make environmental friendly products.
Palavras-Chave:
absorbed radiation doses;
accelerators;
calorimetry;
electron beams;
irradiation;
mechanical properties;
mixing;
polymers;
radiation dose units;
scanning electron microscopy;
thermodynamic properties
MUNHOZ, PEDRO M.; SILVA, LEONARDO G. de A. e; HARADA, JULIO; NASCIMENTO, FERNANDO C.; CALVO, WILSON A.P.
Poly (butylene adipate co-terephthalate)/poly (lactic acid) (PBAT/PLA) blend characterization processed by electron beam.
In:
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 21-25, 2019,
Santos, SP.
Proceedings...
Rio de Janeiro: Associação Brasileira de Energia Nuclear,
2019.
p. 2510-2524.
Disponível em: http://repositorio.ipen.br/handle/123456789/30637. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VIEIRA, FABIO P.B.; BEVILACQUA, JOYCE S.; RODRIGUES JUNIOR, ORLANDO
.
Pós-processamento de espectros de RPE de substâncias dosimétricas por filtragem da transformada discreta de Fourier.
In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4.,
August 26-29, 2014,
Gramado, RS.
Anais...
2014.
Palavras-Chave:
electron spin resonance;
absorbed radiation doses;
spectra;
radioactive materials;
fourier analysis;
algorithms
VIEIRA, FABIO P.B.; BEVILACQUA, JOYCE S.; RODRIGUES JUNIOR, ORLANDO.
Pós-processamento de espectros de RPE de substâncias dosimétricas por filtragem da transformada discreta de Fourier.
In:
CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4.,
August 26-29, 2014,
Gramado, RS.
Anais...
2014.
Disponível em: http://repositorio.ipen.br/handle/123456789/23397. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ARAUJO, SUMAIR G.
; LANDINI, LILIANE
; ZEFERINO, GABRIEL R.; SALVADOR, VERA L.R.
; SCAPIN, MARCOS A.
.
Preliminary assessment of the content of rare earth elements, uranium and thorium in tantalite after processing with microwave.
In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 21-25, 2019,
Santos, SP.
Proceedings...
Rio de Janeiro: Associação Brasileira de Energia Nuclear,
2019.
p. 2525-2531.
Abstract:
The microwave application of (MW) was studied with the aim of verifying the potentiality in the processing of tantalite containing compounds of rare earth elements (REEs), uranium and thorium (radioactivity level was below the background). The samples were prepared powdered and had, as initial composition, mainly: Ta2O5 (24.20)%, La2O3 (18.00%), CeO2 (6.30%), Nd2O3 (2.35%), Pr6O11 (1.99%), Y2O3 (1.57%), ThO2(0.11%) and U3O8(0.035%). They were processed in the microwave batch reactor (2.45GHz, 2kW). After the processing, the results of characterization by X-Ray Fluorescence (FRX), Scanning Electron Microscopy (SEM) and Energy-Disperse X-Ray Spectroscopy (EDS) showed that the content of the main compounds of REEs, besides Th and U were: La2O3 (9.38%), CeO2 (20.00%), Nd2O3 (6.29%), Pr6O11 (3.58%), Y2O3 (2.57%), ThO2(0.33%) and U3O8(0.036%). This occurred in the samples prepared with distilled water and irradiated with 15bar of H2. These preliminary tests were promising, but more experiments are needed, since many variables may still be explored and laboratory infrastructure is available for this purpose, at IPEN-CNEN/SP. As the demand for the use of REEs is rapidly increasing, due to the various applications (for example, as neutron moderators in nuclear reactors, special magnets, TV screens, cell phones and computers, catalysts, missiles, electric vehicles, wind and solar energy, among others), future studies would make it possible to add value and improve the quality of this ore. Finally, microwave technology could be used as an alternative for the reuse of these elements contained in mineral exploration residues.
Palavras-Chave:
absorbed radiation doses;
accelerators;
electron beams;
irradiation;
lactic acid;
mechanical properties;
mixing;
polymers;
thermodynamic properties
ARAUJO, SUMAIR G.; LANDINI, LILIANE; ZEFERINO, GABRIEL R.; SALVADOR, VERA L.R.; SCAPIN, MARCOS A.
Preliminary assessment of the content of rare earth elements, uranium and thorium in tantalite after processing with microwave.
In:
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE,
October 21-25, 2019,
Santos, SP.
Proceedings...
Rio de Janeiro: Associação Brasileira de Energia Nuclear,
2019.
p. 2525-2531.
Disponível em: http://repositorio.ipen.br/handle/123456789/30638. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o
significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo
será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.