Navegação por assunto "plasma"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 10075

    RIBEIRO, K.J.B.; ALVES JUNIOR, C.; GOMES, U.U.; HAJEK, V.; COSTA, F.A.. Gradiente de funcao obtido em pastilhas W-Cu sinterizadas em plasma. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 15., 9-13 nov, 2002, Natal, RN. Anais... 2002. p. 3309-3316.

    Palavras-Chave: tungsten; copper; sintering; plasma

  • IPEN-DOC 24366

    REIS, ADRIANO G. ; REIS, DANIELI A.P.; ABDALLA, ANTONIO J.; OTUBO, JORGE; COUTO, ANTONIO A. ; PIORINO NETO, FRANCISCO. Hot tensile behavior and fracture characteristics of a plasma nitrided maraging 300 steel. Materials Science Forum, v. 899, p. 436-441, 2017. DOI: 10.4028/www.scientific.net/MSF.899.436

    Abstract: The influence of plasma nitriding of a maraging 300 steel on mechanical properties at high temperature has been studied. Samples were tensile tested at 600°C in four conditions: solution treated (MAR-S), solution treated and aged (MAR-SA), solution treated and plasma nitrited (MAR-SP) and solution treated, aged and plasma nitrited (MAR-SAP). In the same sequence, the yield strength and ultimate tensile strength increased slightly respectively from 1073 to 1189 MPa and 1174 to 1301 MPa, an increase of about 10% due to plasma nitriding. All the samples presented similar values of elongation, around 18%, but the cross section area reduction decreased significantly by plasma nitriding from ~70% for MAR-S and MAR-SA to ~45% for MAR-SP and MAR-SAP, that is an decrease of 36% in average. This decrease is attributed to brittle fracture nucleated at 50 μm thick iron nitride layer. The inner fracture surface of the tensile tested specimens was predominantly ductile presenting characteristic microcavities.

    Palavras-Chave: plasma; nitridation; tensile properties; hot cells; fractures; maraging steels

  • IPEN-DOC 01189

    COPPI, B.; FERREIRA, A.; MARK, J.W.K.; RAMOS, J.J.. Ideal-MHD stability of finite-beta plasmas. Nuclear Fusion, v. 19, n. 6, p. 715-25, 1979.

    Palavras-Chave: ballooning instability; magnetohydrodynamics; plasma; stability

  • IPEN-DOC 11629

    DENADAI-SOUZA, A.; TEIXEIRA, S.A.; YSHII, L.M.; RIBELA, M.T.C.P. ; SPOLIDORIO, L.C.; CASATTI, C.A.; COSTA, S.K.; MUSCARA, M.N.. Inflammation maekers and mechanical allodynia following carrageenan-iduced arthritis of rat temporomandibular joint. In: CONGRESSO BRASILEIRO DE FARMACOLOGIA E TERAPEUTICA EXPERIMENTAL, 38., 18-21 de out, 2006, Ribeirao Preto, SP. Resumos... 2006.

    Palavras-Chave: rheumatic diseases; bone joints; inflammation; pain; radioprotective substances; plasma; algae; rats

  • IPEN-DOC 17337

    PINEDO, CARLOS E.; MONTEIRO, WALDEMAR A. . Influence of heat treatment and plasma nitring parameters on hardening an AISI 420 martensitic stainless steel. In: INTERNATIONAL FEDERATION FOR HEAT TREATMENT AND SURFACE ENGINEERING, 18th, July 26-30, 2010, Rio de Janeiro, RJ. Proceedings... 2010. p. 4750-4757.

    Palavras-Chave: stainless steels; martensitic steels; heat treatments; nitridation; plasma; surface hardening; surface treatments

  • IPEN-DOC 15883

    CAMPOS, M.; SOUZA, S.D. de; MARTINEZ, L.G. ; DIONYSIO, M.O.. Influencia da temperatura e tempo na nitretacao a plasma do aco inoxidavel AISI 316L. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 19., 21-25 de novembro, 2010, Campos do Jordao, SP. Resumos... 2010. p. 6148.

    Palavras-Chave: ceramography; crystallography; diffuse scattering; microhardness; nitridation; nitrides; plasma; scanning electron microscopy; structural chemical analysis; vickers hardness; x radiation; x-ray diffraction

  • IPEN-DOC 19537

    OLZON DIONYSIO, M.; CAMPOS, M. ; HIGA, O.Z. ; CUNHA, T.F. da; SOUZA, S.D. de. Investigating the correlation between some of the properties of plasma nitrided AISI 316L stainless steel. Materials Research, v. 16, n. 5, p. 1052-1057, 2013.

    Palavras-Chave: plasma; nitridation; stainless steels; thickness; hardness; x-ray diffraction; toxicity

  • IPEN-DOC 19048

    GROSSO, R.L.; BERTOLETE, M.; MACHADO, I.F.; MUCCILLO, R. ; MUCCILLO, E.N.S. . Ionic conductivity and phase stability of spark plasma sintered scandia and ceria-stabiliezed zirconia. Solid State Ionics, v. 230, p. 48-51, 2013.

    Palavras-Chave: scandium oxides; cerium oxides; zirconium oxides; ionic conductivity; phase stability; plasma; microstructure; impedance; spectroscopy

  • IPEN-DOC 28999

    GOMES, PAULO V.R. ; AZEREDO, NATHALIA F.B. ; GARCIA, LUIS M.S. ; ZAMBIAZI, PRISCILLA J. ; MORSELLI, GIOVANNI R.; ANDO, ROMULO A.; OTUBO, LARISSA ; LAZAR, DOLORES R.R. ; SOUZA, RODRIGO F.B. de ; RODRIGUES, DEBORA F.; NETO, ALMIR O. . Layered graphene/hexagonal boron nitride nanosheets (Gr/h-BNNs) applied to the CO2 photoconversion into methanol. Applied Materials Today, v. 29, p. 1-8, 2022. DOI: 10.1016/j.apmt.2022.101605

    Abstract: Photocatalysts based on heterostructure 2D materials show promising properties for the construction of optoelectronic devices for selective reduction of CO2 to methanol. In this sense, a fast and simple method to produce 2D hexagonal hybrid BN nanosheets (h-BNNs) doped with graphene heterostructure by van der Waals interactions was developed. The method used plasma created by a Tesla coil. The Gr/h-BNNs hybrid material obtained presented a stacking structure containing h-BNNs and graphene layers. The structure included doping of carbon atoms along the h-BN edge structures. The doping of the h-BN nanostructure with graphene sheets, conferred adaptable optical properties to the semiconductor, resulting in band gap energy values favorable to photocatalysis. The reaction promoted selective reduction of CO2 to methanol, and synthesis of other products, such as formaldehyde and formic acid, due to multielectronic transfer processes.

    Palavras-Chave: plasma; boron nitrides; doped materials; graphene; nanofilms

  • IPEN-DOC 27730

    MANGIAROTTI, A.; PETRI, A.R.; MALAFRONTE, A.A.; GONCALVES, J.A.C. ; BARROS, S.F.; BUENO, C.C. ; FERNANDEZ-VAREA, J.M.; MAIDANA, N.L.; MARTINS, M.N.; VANIN, V.R.. A low-cost small-size commercial PIN photodiode: II. Comparison of measurements with monoenergetic electrons to analytical expressions and Monte Carlo simulations. Radiation Physics and Chemistry, v. 182, p. 1-20, 2021. DOI: 10.1016/j.radphyschem.2020.109102

    Abstract: Commercial PIN photodiodes, repurposed as particle detectors, have received a lot of attention along the past decades because they can offer a low-cost solution suitable for several applications. The BPX-65 photodiode has been chosen because of its interesting features for measuring electrons in a harsh radiation environment close to the beam of an accelerator. Its electrical characterisation and its application to photon spectrometry have been presented in the companion paper I. Here, its response function (RF) to electrons is investigated using the beam from an electron accelerator with a small energy spread. The empirical expressions for the RF available in the literature have been improved, simplified, and combined to obtain a final form with 7 free parameters: 4 non-linear and 3 linear. A special fitting procedure, which takes advantage of the presence of the linear parameters, is described. The behaviour of these parameters with beam energy and bias is investigated to uncover the physical origin of the three components included in the proposed RF. The interpretation of the features of the spectra is confirmed by Monte Carlo simulations carried out employing the general-purpose PENELOPE/penEasy package. To take into account the charge-collection properties of the device, a simple model has been implemented and is compared to data. It has then been possible to estimate the thickness of the partially dead layer from the experiment.

    Palavras-Chave: photodiodes; silicon; monte carlo method; plasma; experiment planning; response functions

  • IPEN-DOC 27376

    MALAFRONTE, A.A.; PETRI, A.R.; GONCALVES, J.A.C. ; BARROS, S.F.; BUENO, C.C. ; MAIDANA, N.L.; MANGIAROTTI, A.; MARTINS, M.N.; QUIVY, A.A.; VANIN, V.R.. A low-cost small-size commercial PIN photodiode: I. Electrical characterisation and low-energy photon spectrometry. Radiation Physics and Chemistry, v. 179, p. 1-11, 2021. DOI: 10.1016/j.radphyschem.2020.109103

    Abstract: Silicon PIN (p-type-intrinsic-n-type) photodiodes are well suited as particle detectors. Here the interest is on a low-cost solution by repurposing a commercial device meant to be used as a light sensor. The intended application is to measure the energy spectra of electrons scattered by thin metallic foils covering small angles close to the beam of the accelerator. The main requirements for a suitable device are: 1) a low-cost solution to allow frequent replacements; 2) a small size to avoid as much as possible an unused area that contributes with unnecessary capacitance; 3) a good energy resolution; and 4) an easy repurposing as a charged-particle detector. The photodiode type BPX 65 manufactured by Osram® fulfils well these requirements. Four samples of these commercial devices have been electrically characterised with respect to reverse current and depleted-region capacitance. At the selected working point of 18 V, comfortably below the maximum rating of 20 V recommended by the manufacturer for continuous operation, the total thickness of the depleted and intrinsic regions is estimated to be (60 ± 3) μm. For the four samples considered, the measured reverse currents for a reverse bias of 18 V are around 0.1 nA, well below the typical value specified by the manufacturer (1 nA). To evaluate the performance of the device as a detector, energy spectra have been acquired for γ-rays with energies from 10 to 140 keV using 241Am, 133Ba, and 57Co radioactive sources. The resolution of the BPX 65 encountered with the γ-rays emitted by 241Am at 59.5-keV is 2.5 keV (FWHM - Full Width at Half Maximum), which is close to the value obtained with a pulser, showing that its main limitation is the electronic chain employed in the setup. The response function to monoenergetic electrons in the same energy range is studied in the companion paper.

    Palavras-Chave: photodiodes; p-type conductors; silicon; si semiconductor detectors; x-ray spectroscopy; gamma spectroscopy; semiconductor diodes; plasma

  • IPEN-DOC 09769

    NARDES, A.M.; ANDRADE, A.M.; FONSECA, F.J.; DIRANI, E.A.T.; MUCCILLO, R. ; MUCCILLO, E.N.S. . Low-temperature PECVD deposition of highly conductive microcrystalline silicon thin films. In: INTERNATIONAL CONFERENCE ON MATERIALS FOR MICROELECTRONICS AND NANOENGINEERING, 4th, June 10-12, 2002, Espoo, Finland. Proceedings... 2002. p. 407-411.

    Palavras-Chave: silicon; thin films; chemical vapor deposition; plasma; temperature range 0273-0400 k; temperature range 0400-1000 k; electric conductivity; structural chemical analysis; hall effect; impedance; spectroscopy

  • IPEN-DOC 09768

    NARDES, A.M.; ANDRADE, A.M.; FONSECA, F.J.; DIRANI, E.A.T.; MUCCILLO, R. ; MUCCILLO, E.N.S. . Low-temperature PECVD deposition of highly conductive microcrystalline silicon thin films. Journal of Materials Science: Materials in Electronics, v. 14, n. 5/7, p. 407-411, 2003.

    Palavras-Chave: silicon; thin films; chemical vapor deposition; plasma; temperature range 0273-0400 k; temperature range 0400-1000 k; electric conductivity; structural chemical analysis; hall effect; impedance; spectroscopy

  • IPEN-DOC 24803

    ULRICH, J.C. ; GUILHEN, S.N. ; COTRIM, M.E.B. ; PIRES, M.A.F. . Method development and validation for simultaneous determination of IEA-R1 reactor’s pool water uranium and silicon content by ICP OES. Journal of Physics: Conference Series, v. 975, n. 012012, p. 1-5, 2018. DOI: 10.1088/1742-6596/975/1/012012

    Abstract: IPEN’s research reactor, IEA-R1, an open pool type research reactor moderated and cooled by light water. High quality water is a key factor in preventing the corrosion of the spent fuel stored in the pool. Leaching of radionuclides from the corroded fuel cladding may be prevented by an efficient water treatment and purification system. However, as a safety management policy, IPEN has adopted a water chemistry control which periodically monitors the levels of uranium (U) and silicon (Si) in the pool’s reactor, since IEA-R1 employs U3Si2-Al dispersion fuel. An analytical method was developed and validated for the determination of uranium and silicon by ICP OES. This work describes the validation process, in a context of quality assurance, including the parameters selectivity, linearity, quantification limit, precision and recovery.

    Palavras-Chave: validation; pool type reactors; uranium; silicon; emission spectroscopy; optical systems; plasma

  • IPEN-DOC 24450

    ULRICH, JOAO C. ; GUILHEN, SABINE N. ; COTRIM, MARYCEL E.B. ; PIRES, MARIA A.F. . Method development and validation for simultaneous determination of IEAR1 reactor's pool water U and Si content by ICP OES. In: CONGRESSO BRASILEIRO DE METROLOGIA, 9.; CONGRESSO INTERNACIONAL DE METROLOGIA MECANICA, 4.; CONGRESSO INTERNACIONAL DE METROLOGIA ELETRICA, 12.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇOES IONIZANTES, 4.; WORKSHOP DA REDE DE METROLOGIA QUIMICA DO INMETRO, 3.; CONGRESSO BRASILEIRO DE METROLOGIA OPTICA, 2., 26-29 de novembro, 2017, Fortaleza, CE. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2017. p. 1-5.

    Palavras-Chave: validation; pool type reactors; uranium; silicon; emission spectroscopy; optical systems; plasma

  • IPEN-DOC 18360

    CASTAGNET, M. ; YOGI, L.M.; SILVA, M.M.; UEDA, M.; COUTO, A.A. ; REIS, D.A.P.; MOURA NETO, C.. Microstructural analysis of Ti6Al-4V alloy after plasma immersion ion implantation (PIII). Materials Science Forum, v. 727-728, p. 50-55, 2012.

    Palavras-Chave: titanium alloys; aluminium alloys; microstructure; mechanical properties; creep; plasma; ion implantation; optical microscopy

  • IPEN-DOC 17925

    CASTAGNET, M. ; YOGI, L.M.; SILVA, M.M.; UEDA, M.; COUTO, A.A. ; REIS, D.A.P.; MOURA NETO, C.. Microstructural analysis of Ti6Al-4V alloy after plasma immersion ion implantation (PIII). In: INTERNATIONAL LATIN-AMERICAN CONFERENCE ON POWDER TECHNOLOGY, 8th, November 6-9, 2011, Florianopolis, SC. Proceedings... 2011. p. 77-82.

    Palavras-Chave: titanium alloys; aluminium alloys; microstructure; mechanical properties; creep; plasma; ion implantation; optical microscopy

  • IPEN-DOC 29038

    ALENCAR E SILVA, G.S. de; LEAL NETO, R.M. ; FILGUEIRA, M.; BAPTISTA, C.A.R.P.; SANTOS, C. dos; RAMOS, A.S.. Microstructure and diametral fracture strength of spark plasma sintered WC-6Co-0.2B and WC-6Co-0.5B ceramic composites from nanosized and metastable WC powders. Cerâmica, v. 68, n. 386, p. 188-198, 2022. DOI: 10.1590/0366-69132022683863210

    Abstract: The present work aimed at evaluating the microstructures and mechanical properties of spark plasma sintered WC-6 wt% Co ceramic composites doped with boron (0.2 and 0.5 wt%). W-50 at% C (W-6.13 wt% C) powders produced under different milling times (20, 60, 180, and 600 min) were used as starting materials and subsequently mixed with Co (6 wt%) and B (0.2 or 0.5 wt%) powders for 5 min. The resultant WC-Co-B powder mixtures were consolidated by spark plasma sintering at 1450 °C for 10 min at 40 MPa under vacuum in order to obtain the samples with 10 mm diameter and 3 mm thickness. The starting powders and the sintered samples were characterized by laser diffraction particle size analysis, X-ray diffraction with Rietveld refinement, relative density, scanning electron microscopy, energy dispersive spectrometry, Vickers hardness test, and diametral compression test. Supersaturated W solid solution (WSS) with a crystallite size of <50 nm was formed in W-50C (at%) powder mixtures. The relative density of the sintered composites increased with the increasing milling time up to 180 min from 79.7%±0.6% to 86.7%±0.5% for WC-6Co-0.2B and from 86.7%±0.6% to 90.9%±0.4% for WC-6Co-0.5B. Furthermore, the WC phase appeared as the matrix in the sintered samples, and W2CoB2 precipitated homogeneously around WC grain boundaries, mainly to those containing 0.5% B. The Vickers hardness values of the sintered WC-6Co-0.2B and WC-6Co-0.5B ranged from 1790±39 to 2158±25 HV and 1858±31 to 2182±28 HV, respectively. The fracture strength (determined by diametral compression test) varied between 144-353 MPa due to the porosity and precipitates in thin-thickness cylinder samples.

    Palavras-Chave: boron; ceramics; cobalt; composite materials; density; mechanical properties; microstructure; particle size; plasma; sintering; tungsten carbides; vickers hardness

  • IPEN-DOC 25795

    FERREIRA, NELSON D.; LEAL NETO, RICARDO M. ; FILGUEIRA, MARCELLO; FERREIRA, LUCAS M.; ALVES, MANUEL F.R.P.; RAMOS, ERIKA C.T.; NUNES, CARLOS A.; SANTOS, CLAUDINEI dos; RAMOS, ALFEU S.. Microstructure and Vickers hardness of mechanically alloyed and spark plasma sintered Ti-2Zn-22Si-11B and Ti-6Zn-22Si-11B alloys. Journal of Alloys and Compounds, v. 794, p. 615-624, 2019. DOI: 10.1016/j.jallcom.2019.04.172

    Abstract: This work reports on effect of zinc and milling time on microstructure and Vickers hardness of mechanically alloyed and spark plasma sintered (66,7-x)Ti-xZn-22,2Si-11,1B alloys (at.-%, with x ¼ 2 and 6 at.-%). Ball milling at different times (20, 60, 180 and 300 min) was performed under argon atmosphere in a planetary ball mill from these elemental powder mixtures. Cylinder bodies with 10mm diameter were consolidated by spark plasma sintering (1100 C, 12 min, 20MPa) under argon atmosphere. Asmilled powders and sintered Ti-Zn-Si-B samples were evaluated by X-ray diffraction, scanning electron microscopy, energy dispersive spectrometry, laser diffraction particle size analysis, and Vickers hardness tests. It was noted a similar behavior during ball milling of Ti-Zn-Si-B powder mixtures. Only the a-Ti and Si peaks were indexed in XRD patterns of Ti-Zn-Si-B powders milled for 300min. Rietveld refining indicated that the amount of amorphous structures has increased during milling up to 300 min, which was more pronounced for the Ti-6Zn-22Si-11B powders. The particle sizes of the Ti-2Zn-22Si-11B and Ti-6Zn-22Si-11B powder mixtures increased during milling from 94 (20 min) to 156 (300min) mm and from 101 (20 min) to 136 (300 min) mm, respectively. Coherently, the average specific surface area of powder particles was continuously reduced during milling. Despite the adopted parameters, the SPS process produced dense Ti-xZn-22Si-11B (x ¼ 2 and 6 at.-%) alloys with 98% from their theoretical specific mass. Regardless of milling time, the Ti6Si2B formation was inhibited in microstructure of the spark plasma sintered Ti-6Zn-22Si-11B alloy previously milled for longer times. EDS analysis indicated that the Ti6Si2B phase dissolved close to 1.8 at.-% Zn. Beside the TiB and Ti5Si3, the Ti2Zn and Ti3Zn (not explored) phases were also found in microstructure of sintered Ti-Zn-Si-B alloys. The Ti-2Zn-22Si-11B alloy presented average Vickers hardness values higher than 1050 HV whereas the Ti-6Zn-22Si-11B alloy varied between 970 and 1036 HV, which could be associated with the Ti6Si2B formation.

    Palavras-Chave: zinc; titanium alloys; vickers hardness; plasma; sintering; microstructure; healing; bone mineral density

  • IPEN-DOC 22540

    SOUZA, S.D. de; OLZON DIONYSIO, M.; BASSO, R.L.O.; SOUZA, S. de . Mossbauer spectroscopy study on the corrosion resistance of plasma nitrided ASTM F138 stainless steel in chloride solution. Materials Characterization, v. 61, p. 992-999, 2010.

    Palavras-Chave: stainless steels; plasma; spectroscopy; x-ray diffraction; corrosion; corrosion resistance; chlorides; solutions

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.