JavaScript is disabled for your browser. Some features of this site may not work without it.
Navegação por Autores IPEN "ALENCAR, MAICON C. de"
-
MICELLI, ANA L.P.
; NIGRO, FREDERICO
; MUCSI, CRISTIANO S.
; ALENCAR, MAICON C. de
; ARANHA, LUIS C.
; ROSSI, JESUALDO L.
.
Analysis of the pullout testing of straight and angled abutments in narrow diameter implants.
Materials Science Forum,
v. 1012,
p. 461-465,
2020.
DOI:
10.4028/www.scientific.net/MSF.1012.461
Abstract:
Despite the success of osseointegrated implants, some biomechanical problems such as
loosening or fracture of the abutment, crown fixation screw loosening and prosthetic instability, are
common problems reported in the literature. Thus, the objective of the present study was to analyze
the pullout resistance of straight and angled abutments in narrow diameter implants installed by
means of friction. The specimen was composed of an implant of 3.3 mm x 11 mm fixed 2 mm above
of a resin block. The abutments were fixed by friction receiving 3, 5 and 7 strikes of 0.05 J along the
implant axis, and were positioned with 0˚, 10˚ and 20˚ of angulation. The abutments were subjected
to pullout load, totalizing 10 repetitions for each test, i.e., the abutment was reinserted up to 10 times
in the same implant. The results showed higher values of pullout load for the abutments with 7 strikes,
and no statistical difference with 5 strikes suggesting better mechanical stability.
Palavras-Chave:
implants;
dentistry;
bone tissues;
testing;
prostheses;
teeth;
extraction;
connectors
MICELLI, ANA L.P.; NIGRO, FREDERICO; MUCSI, CRISTIANO S.; ALENCAR, MAICON C. de; ARANHA, LUIS C.; ROSSI, JESUALDO L.
Analysis of the pullout testing of straight and angled abutments in narrow diameter implants.
Materials Science Forum,
v. 1012,
p. 461-465,
2020.
DOI:
10.4028/www.scientific.net/MSF.1012.461.
Disponível em: http://repositorio.ipen.br/handle/123456789/31828. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VIVEIROS, BARBARA V.G. de
; DONATUS, UYIME
; ALENCAR, MAICON C. de
; BERBEL, LARISSA O.
; COSTA, ISOLDA
.
Comparing the corrosion behaviour of AA2050 and AA7050 aluminium alloys by scanning vibrating electrode and scanning ion-selective electrode techniques.
Corrosion Engineering, Science and Technology,
v. 57,
n. 1,
p. 85-96,
2022.
DOI:
10.1080/1478422X.2021.1992132
Abstract:
The susceptibility to localised corrosion of the high strength alloys, AA2050-T84 and AA7050-T7451, used in the aerospace industry, was investigated in this study by localised electrochemical techniques, specifically, scanning vibrating electrode technique (SVET) and scanning ion-selective electrode technique (SIET), in 0.005 mol L−1 NaCl solution. The study was initially carried out using both alloys individually and then, coupling the two alloys and evaluating the effect of galvanic coupling between them. The results revealed that the AA2050-T84, being nobler than the AA7050-T7451, presented higher corrosion current density values when tested in isolation and the depth of corrosion penetration was significantly deeper in the AA2050-T84 alloy than in the AA7050-T7451. However, galvanic coupling of the two alloys resulted in cathodic protection of the AA2050-T84 alloy and a reduction in corrosion current densities on both alloys.
Palavras-Chave:
aluminium alloys;
corrosion resistance;
intergranular corrosion;
pitting corrosion;
coupling;
electrochemical corrosion;
electrodes;
ion-selective electrodes
VIVEIROS, BARBARA V.G. de; DONATUS, UYIME; ALENCAR, MAICON C. de; BERBEL, LARISSA O.; COSTA, ISOLDA.
Comparing the corrosion behaviour of AA2050 and AA7050 aluminium alloys by scanning vibrating electrode and scanning ion-selective electrode techniques.
Corrosion Engineering, Science and Technology,
v. 57,
n. 1,
p. 85-96,
2022.
DOI:
10.1080/1478422X.2021.1992132.
Disponível em: http://repositorio.ipen.br/handle/123456789/33038. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
DONATUS, UYIME
; VIVEIROS, BARBARA V.G. de
; ALENCAR, MAICON C. de
; FERREIRA, RAPHAEL O.; MILAGRE, MARIANA X.
; COSTA, ISOLDA
.
Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in friction stir weldment of AA2198 alloy.
Materials Characterization,
v. 144,
p. 99-112,
2018.
DOI:
10.1016/j.matchar.2018.07.004
Abstract:
Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in the friction stir weldment of AA2198-T851 alloy has been investigated. Different microscopy techniques, scanning vibrating electrode technique (SVET) and potentiodynamic polarization tests were employed in the investigation. Unlike other 3rd generation Al-Cu-Li alloys where the regions that are most susceptible to corrosion are always within the weld region, the results reveal that the parent material is the most susceptible in this case. There is a direct correlation between corrosion resistance, anodic hydrogen evolution and microhardness in the weldment, and the T1 phase is associated with the direct correlation.
Palavras-Chave:
aluminium alloys;
corrosion resistance;
friction;
microhardness;
pitting corrosion;
polarization;
welded joints
DONATUS, UYIME; VIVEIROS, BARBARA V.G. de; ALENCAR, MAICON C. de; FERREIRA, RAPHAEL O.; MILAGRE, MARIANA X.; COSTA, ISOLDA.
Correlation between corrosion resistance, anodic hydrogen evolution and microhardness in friction stir weldment of AA2198 alloy.
Materials Characterization,
v. 144,
p. 99-112,
2018.
DOI:
10.1016/j.matchar.2018.07.004.
Disponível em: http://repositorio.ipen.br/handle/123456789/29299. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
LEITE, DANIELA M.C.
; ALENCAR, MAICON C. de
; MUCSI, CRISTIANO S.
; ARAUJO, JOAO V.S.
; TAVARES, LUIZ A.
; BERBEL, LARISSA O.
; ARANHA, LUIS C.
; ROSSI, JESUALDO L.
.
Modifications of titanium and zirconium alloy surfaces for use as dental implants.
Materials Science Forum,
v. 1012,
p. 477-482,
2020.
DOI:
10.4028/www.scientific.net/MSF.1012.477
Abstract:
The use of dental implants of titanium and its alloys has proved to be effective, through
well established and documented parameters, both in the dimensions and in the manufacturing
processes and also in the surgical techniques. There are clinical situations where there is a need to
reduce the diameter of the implants, below 3.75 mm in diameter. In the current state of art of the
implant technology it is desirable that these also have surfaces capable of decreasing the period of
osseointegration. In the present work, to improve the mechanical strength of the material, an alloy
of 80% of Ti and 20% of Zr % in mass was proposed and elaborated, aiming its use as biomaterial.
Physical, chemical, microstructural and mechanical characterization was carried out. The surfaces
of the treated samples were observed using: scanning electron microscopy (SEM); semi
quantitatively chemically analyzed using dispersive energy spectroscopy (EDS: wettability of the
samples was determined and, finally, the roughness was measured using optical profilometry. For
the conditions used in the present work, it was concluded, that the best surface treatment for the
TiZr 80/20 alloy was acid etching with 1% vol. hydrofluoric acid for 5 minutes, as this treatment
presented the most prominent results of wettability and roughness simultaneously.
Palavras-Chave:
titanium;
zirconium;
alloys;
implants;
dentistry;
biological materials;
melting;
scanning electron microscopy;
spectroscopy;
energy;
dispersion relations;
bone tissues
LEITE, DANIELA M.C.; ALENCAR, MAICON C. de; MUCSI, CRISTIANO S.; ARAUJO, JOAO V.S.; TAVARES, LUIZ A.; BERBEL, LARISSA O.; ARANHA, LUIS C.; ROSSI, JESUALDO L.
Modifications of titanium and zirconium alloy surfaces for use as dental implants.
Materials Science Forum,
v. 1012,
p. 477-482,
2020.
DOI:
10.4028/www.scientific.net/MSF.1012.477.
Disponível em: http://repositorio.ipen.br/handle/123456789/31829. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ARAUJO, JOAO V. de S.
; DONATUS, UYIME
; QUEIROZ, FERNANDA M.; TERADA, MAYSA; MILAGRE, MARIANA X.
; ALENCAR, MAICON C. de
; COSTA, ISOLDA
.
On the severe localized corrosion susceptibility of the AA2198-T851 alloy.
Corrosion Science,
v. 133,
p. 132-140,
2018.
DOI:
10.1016/j.corsci.2018.01.028
Abstract:
The time dependent susceptibility of AA2198-T851 Al-Cu-Li alloy to severe localized corrosion in 0.01 mol L-1 NaCl solution has been investigated by immersion and SVET tests. The results reveal that the propagation of severe localized corrosion, in the alloy, is crystallographic and it is associated with the slip bands in the individual grains of the alloy. The slip bands caused uneven precipitation of the active T1 particles. Also, oscillations in SVET current density values associated with deposition and detachment of corrosion products were observed. Furthermore, the intensity of corrosion activities increased over time for open or partially covered pits.
Palavras-Chave:
corrosion;
aluminium alloys;
pitting corrosion;
transmission electron microscopy;
scanning electron microscopy;
optical microscopy;
microstructure
ARAUJO, JOAO V. de S.; DONATUS, UYIME; QUEIROZ, FERNANDA M.; TERADA, MAYSA; MILAGRE, MARIANA X.; ALENCAR, MAICON C. de; COSTA, ISOLDA.
On the severe localized corrosion susceptibility of the AA2198-T851 alloy.
Corrosion Science,
v. 133,
p. 132-140,
2018.
DOI:
10.1016/j.corsci.2018.01.028.
Disponível em: http://repositorio.ipen.br/handle/123456789/28922. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
COUTO, CAMILA P.
; COSTA, ISOLDA
; VIVEIROS, BARBARA V.G. de
; ALENCAR, MAICON C. de
; COLOSIO, MARCO A.; PANOSSIAN, ZEHBOUR; ROSSI, JESUALDO L.
.
The use of scanning vibrating electrode technique to evaluate the effect of hot stamping on the corrosion resistance of 22MnB5 press-hardened steel electroplated with Zn-Ni.
Materials Research,
v. 22,
suppl. 1,
p. 1-6,
2019.
DOI:
10.1590/1980-5373-MR-2019-0163
Abstract:
Carmakers must achieve the worldwide targets for lightweight materials, safety and reducing the
fuel consumption. The use of press-hardened steel (PHS), in vehicle structures has been contributing
with these requirements. This type of steel is widely used for the hot-stamping which consists in heating
the steel blank to total austenitization temperature and then transferring it from the furnace into the
die tool where the steel is formed and quenched at the same time. PHS is usually protect with metallic
coatings in order to avoid both steel oxidation and decarburization. Hot-dip Al-Si coating is currently
the main used in this application. However, alternative coatings, like zinc-based, are under investigation.
This work aims at evaluating the corrosion resistance of the 22MnB5 grade PHS, electroplated with
Zn-Ni, before and after hot stamping, using the scanning vibrating electrode technique (SVET). Results
from SVET showed that samples prior to hot stamping, the corrosion mechanism was uniform over
the exposed surface, and was mainly related to selective dissolution of zinc from the coating. On the
other hand, hot stamped samples showed localized corrosion mechanism with decrease in current with
time of immersion due to the formation of corrosion products on the exposed surface.
Palavras-Chave:
coatings;
metals;
hardening;
steels;
automotive industry;
electrolytes;
zinc;
nickel;
electroplating;
corrosion resistance;
scanning electron microscopy;
backscattering;
electrons;
corrosion protection
COUTO, CAMILA P.; COSTA, ISOLDA; VIVEIROS, BARBARA V.G. de; ALENCAR, MAICON C. de; COLOSIO, MARCO A.; PANOSSIAN, ZEHBOUR; ROSSI, JESUALDO L.
The use of scanning vibrating electrode technique to evaluate the effect of hot stamping on the corrosion resistance of 22MnB5 press-hardened steel electroplated with Zn-Ni.
Materials Research,
v. 22,
p. 1-6,
2019.
suppl. 1,
DOI:
10.1590/1980-5373-MR-2019-0163.
Disponível em: http://repositorio.ipen.br/handle/123456789/31340. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.