  • IPEN-DOC 12830

    GONCALVES, J.A.C. ; BOTELHO, S.; PASCHOLATI, P.R.; RIDENTI, M.A.; FRAGA, M.M.F.R.; CAMARA, J.R. ; CALVO, W.A. ; BUENO, C.C. . Activity measurements of sup(192)Ir solid sources using a well-type ionization chamber. Nuclear Instruments and Methods in Physics Research, v. 580, Section A, p. 222-225, 2007.

    Palavras-Chave: iridium 192; technetium 99; ionization chambers; activity levels; decay; sealed sources

  • IPEN-DOC 10684

    BUENO, C.C. ; CAMARGO, F.; GONCALVES, J.A.C. . Analysis of satellite peaks generation in MGR Si diode. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: alpha spectra; americium 241; curium 244; experimental data; ion implantation; n-type conductors; plutonium 239; radiation sources; silicon diodes

  • IPEN-DOC 20243

    SANTOS, T.C. dos ; NEVES JUNIOR, W.F.P.; GONCALVES, J.A.C. ; HADDAD, C.M.K.; HARKONEN, J.; BUENO, C.C. . Characterization of miniature RAD-HARD silicon diodes as dosimeters for small fields of photon beams used in radiotherapy. Radiation Measurements, v. 71, p. 396-401, 2014.

    Palavras-Chave: silicon diodes; zone melting; radiotherapy; dosemeters; photon beams; phantoms; microstructure

  • IPEN-DOC 19771

    SANTOS, T.C.; NEVES JUNIOR, W.F.P.; GONCALVES, J.A.C.; HADDAD, C.M.K.; HARKONEN, J.; BUENO, C.C. . Characterization of rad-hard silicon diodes as dosimeters for small fields of photon and electron beams used in radiotherapy. In: INTERNATIONAL CONFERENCE ON SOLID STATE DOSIMETRY, 17th, 22-27 de setembro, 2013, Recife, PE. Abstract... 2013.

    Palavras-Chave: silicon diodes; dosemeters; photons; electron beams; phantoms; plastics; radiotherapy

  • IPEN-DOC 27864

    GONCALVES, J.A.C. ; BUENO, C.C. ; MANGIAROTTI, A.. Comparative evaluation of the performance of thin diodes used as on-line dosimeters in radiation processing applications. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-8, 2021. DOI: 10.15392/bjrs.v9i1A.1327

    Abstract: In this work, we report a comparison between the performance of two samples of commercial PIN photodiodes (SFH206K from Osram® and S2506-04 from Hamamatsu®) mainly addressing the variation of their current sensitivities with accumulated dose ranging from 0-15 kGy. All the results so far obtained have revealed that the radiation induced currents are linearly dependent on dose rates from 3.65 to 55.64 Gy/h. The current sensitivity of both unirradiated diodes (0.178 nA.h/Gy.mm3) slightly decreases with accumulated dose, namely 0.32%/kGy (SFH206K) and 1.4%/kGy (S2506-04). Although the SFH206K device compares favorably with the S2506-04, both diodes can be considered as a low budge alternative, good enough for on-line dosimetry applications in the field of radiation processing.

    Palavras-Chave: cobalt 60; comparative evaluations; dose rates; dosemeters; dosimetry; gamma radiation; performance; photodiodes; sensitivity

  • IPEN-DOC 25705

    CAMARGO, F.; GONCALVES, J.A.C. ; BUENO, C.C. . A comparison between rad-hard float zone silicon diodes as gamma dosimeter in radiation processing. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-13, 2019. DOI: 10.15392/bjrs.v7i2A.681

    Abstract: In this work, we report on the results obtained with rad-hard Standard Float Zone (STFZ) and Diffused Oxygenated Float Zone (DOFZ) silicon diodes in radiation processing dosimetry. The dosimetric probes were designed to operate in the direct current mode, as on-line radiation dosimeter. The irradiation of the samples was performed using a 60Co source with a dose rate of almost 2.4 kGy/h. The current response of each diode was measured as a function of the exposure time in steps from 5 kGy up to 50 kGy to achieve a total absorbed dose of 275 kGy. In this dose range it is observed a significant decrease in the photocurrent generated in both devices due to gamma radiation defects produced in their active volumes. To mitigate this effect, the samples were pre-irradiated with 60Co gamma rays at 700 kGy. Despite of being less sensitive, these devices presented stable and reproducible current signals with a relative sensitivity decrease of about 19% within the whole range of dose studied. The dose-response curves of the pre-irradiated diodes showed quadratic behavior with correlation coefficient higher than 0.9999 for total absorbed dose up to 275 kGy. The comparison of the diodes’ dosimetric responses evidenced that the best result was achieved with the DOFZ, which exhibited slightly higher sensitivity and stability than the STFZ devices. However, it is important to note that all pre-irradiated diodes can be used as gamma dosimeters in radiation processing applications.

    Palavras-Chave: gamma dosimetry; gamma radiation; absorbed radiation doses; comparative evaluations; zone melting; cobalt 60; silicon diodes; radiation dose units; irradiation; dose rates; oxygen; radiation dose ranges

  • IPEN-DOC 18859

    MANGIAROTTI, A.; BUENO, C.C. . A computer code to calculate then fast induced signals by electron swarms in gases. In: VANIN, VITO R. (Ed.) BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 32rd, September 7-11, 2010, Campos do Jordão, SP. Proceedings... American Institute of Physics, 2010. p. 189-194.

    Palavras-Chave: anodes; boundary conditions; cathodes; computer codes; continuity equations; data analysis; diffusion; electron drift; electron-atom collisions; electrons; finite difference method; gases; laser radiation; townsend discharge

  • IPEN-DOC 08802

    PEIXOTO, T.P.; PASCHOLATI, P.R.; VANIN, V.R.; GONCALVES, J.A.C. ; BUENO, C.C. . Data acquisition system for resistive cathode detectors. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: radiation detectors; data acquisition systems; real time systems; energy spectra; g codes; nuclear instrument modules

  • IPEN-DOC 07864

    PEIXOTO, T.P.; PASCHOLATI, P.R.; VANIN, V.R.; BUENO, C.C. ; GONCALVES, J.A.C. . Data acquisition system for resistive detectors. In: REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 23., 23-27 set, 2000, Campinas, SP. Resumos... 2000. p. 56-57.

    Palavras-Chave: radiation detectors; data acquisition systems; analog-to-digital converters; pulses; peaks; cathodes

  • IPEN-DOC 14856

    FONTE, P.; MANGIAROTTI, A.; BOTELHO, S.; GONCALVES, J.A.C. ; RIDENTI, M.A.; BUENO, C.C. . A dedicated setup for the measurement of the electron transport parameters in gases at large electric fields. Nuclear Instruments and Methods in Physics Research, A, v. 613, n. 1, p. 40-45, 2010.

    Palavras-Chave: electrons; charged-particle transport; electron drift; velocity; townsend discharge; gases; nitrogen; 2-methylpropane

  • IPEN-DOC 23671

    PETRI, A.R. ; MANGIAROTTI, A.; GONÇALVES, J.A.C. ; BUENO, C.C. . Density- normalized first Townsend ionization coefficients in a CH4-based tissue-equivalent gas mixture. In: IEEE NUCLEAR SCIENCE SYMPOSIUM, October 29 - November 5, 2016, Strasbourg, France. Abstract... Nova Iorque: IEEE, 2016.

    Abstract: Since 1950 methane-based tissue-equivalent gas (TEG) mixtures have been employed at low pressure in gaseous microdosimeters, such as tissue-equivalent proportional counters. Nevertheless, values of the first Townsend ionization coefficient (α) for these mixtures are scarce in the literature. In this work measurements of α as a function of the density-normalized electric field (E/N) were carried out in a methane-based TEG (CH4 - 64.4%, CO2 - 32.4% and N2 - 3.2%) in the range 100-300Td. The values of α were obtained using the Pulsed Townsend Technique by measuring the current growth as a function of the electric field strength in a Resistive Plate Chamber structure. Because of the parallel plate geometry, the field is uniform in our setup. As far as the authors are aware, there is only one set of experimental data on α for CH4-TEG published by Schmitz and Booz for reduced field strengths between 110V.cm-1.torr-1 (≈ 315Td) and 1780V.cm-1.torr-1 (≈ 5045Td). However, they employed a cylindrical proportional counter where α /p values were gathered from measurements of the gas gain resulting from an interval of electric field strengths. Because there are no data on α in methane-based TEG in the E/N range herein investigated, our results were compared with those expected from Magboltz simulations. Good agreement was found between experimental and simulated values of density-normalized α.

  • IPEN-DOC 04259

    SANTOS, M.D.S.; BUENO, C.C. ; GONCALVES, J.A.C. . Deteccao de particulas alfa em um detector de faisca. In: 14a. REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 2-6 de setembro, 1991, Aguas de Lindoia, SP. 1991.

    Palavras-Chave: alpha particles; spark counters

  • IPEN-DOC 08804

    CORREA, A.A.S.; BUENO, C.C. ; GONCALVES, J.A.C. ; SANTOS, M.D.S.. Deteccao e espectrometria de eletrons de conversao interna e particulas beta com diodos de Si. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: electron spectrometers; silicon diodes; photodiodes; semiconductor detectors; beta particles

  • IPEN-DOC 05265

    SANTOS, M.D.S.; GONCALVES, J.A.C. ; BUENO, C.C. . Detectores a faisca em ausencia de efeito corona. In: 16a. REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 8-12 de setembro, 1993, Serra Negra, SP. Resumo... 1993. p. 80.

    Palavras-Chave: spark counters; corona discharges

  • IPEN-DOC 04949

    GONCALVES, J.A.C. ; FRAGA, M.M.; BUENO, C.C. ; SANTOS, M.D.S.. Detectores proporcionais de catodo resistivo. In: 4th MEETING ON NUCLEAR APPLICATIONS, ENCONTRO NACIONAL DE APLICACOES NUCLEARES, August 18-22, 1997, Pocos de Caldas, MG. 1997. p. 573-575.

    Palavras-Chave: proportional counters; cathodes; performance testing; x radiation; radiation detectors

  • IPEN-DOC 25759

    GONCALVES, J.A.C. ; BARROS, V.S.M.; ASFORA, V.K.; KHOURY, H.J.; BUENO, C.C. . Diagnostic x-ray dosimeters using standard float zone (FZ) and XRA-50 commercial diodes. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-9, 2019. DOI: 10.15392/bjrs.v7i2A.592

    Abstract: The results obtained with a standard float zone (FZ) silicon diode, processed at the Helsinki Institute of Physics, used as on-line diagnostic X-ray dosimeter are described in this work. The device was connected in the short-circuit current mode to the input of an integrating electrometer. The response repeatability and the current sensitivity coefficient of the diode were measured with diagnostic X-ray beams in the range of 40-80 kV. The dose-response of the device, evaluated from 10 mGy up to 500 mGy, was linear with high charge sensitivity. Nevertheless, significant energy dependence was observed in the charge sensitivity of FZ device for energies below 70 kV. The dosimetric characteristics of this FZ diode were compared to those of an XRA-50 commercial Si diode, specially designed to X-ray dosimetry. The results obtained with the FZ diode evidenced that it can be an alternative choice for diagnostic X-ray dosimetry, although it needs to be calibrated for individual X-ray beam energies. The studies of long-term stability and the radiation hardness of these diodes are under way.

    Palavras-Chave: x-ray dosimetry; x radiation; dose rates; dosemeters; diagnosis; energy dependence; zone melting; silicon diodes; sensitivity; beams; comparative evaluations

  • IPEN-DOC 29315

    GONCALVES, J.A.C. ; MANGIAROTTI, A.; BUENO, C.C. . Dose rate mapping in an industrial 60Co irradiator using an online photodiode-based dosimetry system. In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 15th, December 6-10, 2021, Kuala Lumpur, Malaysia. Abstract... 2021.

    Abstract: In the radiation processing field, any irradiation process is designed to irradiate products uniformly, but in practice, a reasonable variation in the absorbed dose through the product is accepted. However, the irradiation of inhomogeneous or irregularly shaped products gives rise to complex dose variations only assessed through dose mapping. It requires complementary dosimeters bearing good spatial resolution, prompt and easy readout, and cost-effectiveness. These features are found in silicon diodes that, despite all these advantages, are prone to radiation damage. This damage is mitigated with photodiodes whose thicknesses are much smaller than the minority carrier diffusion length at the anticipated accumulated dose. In this work, an in-house dosimetry system based on a thin photodiode is applied for online mapping dose rates, between 3.7 and 52.8 Gy/h, delivered by a Panoramic 60Co industrial facility. The operational principle of these dosimeters relies on the real-time acquisition of the induced currents from the irradiated diode operating in the short-circuit mode without externally applied voltage. Under this condition, the dose is assessed offline via the integration of these current signals. The radial mapping of the radiation field is performed by rotating the diode around the central axis of the panoramic irradiator, covering 360º at intervals of 10º. For comparative purposes, alanine dosimeters are also irradiated together with the diode. The experimental results are benchmarked with Monte Carlo simulations of the dose rate curves. Good agreement between the simulated values and the readings of both dosimeters is found. It reveals that the photodiode-dosimetry system is a reliable alternative to map dose rate fields and the effectiveness of Monte Carlo simulations as a predictive tool for dose rate measurements in an irradiator.

  • IPEN-DOC 26809

    GONCALVES, J.A.C. ; MANGIAROTTI, A.; ASFORA, V.K.; KHOURY, H.J.; BUENO, C.C. . Dosimetric characterization of thin diodes in an electron beam facility for radiation processing. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 3rd, May 27-31, 2019, Lisboa, Portugal. Abstract... Lisboa, Portugal: C2TN, Instituto Superior Técnico, Universidade de Lisboa, 2019.

    Abstract: Introduction: Silicon diodes have been employed as relative dosimeters in clinical photon and electron beams. However, they are prone to radiation damage that produces a drop of their current sensitivities with increasing accumulated doses. This effect is attributed to the decrease of the minority carrier diffusion lengths which diminishes the sensitive volume of the diode. Theoretically, it is possible to mitigate the decay of the current sensitivity by choosing diodes with thicknesses smaller than the lowest minority carrier diffusion lengths anticipated for the foreseen accumulated dose. This surmise has been followed up in this work by evaluating the response of thin diodes (SFH00206K) for the dosimetry of electron beams used in radiation processing. Methods: The diode with 10 μm of depletion layer at 0V was produced on n type Si wafers of 220 m thickness. As a dosimeter, the device was housed in a probe and connected to an electrometer to be operated in short-circuit current mode without bias voltage. To carry out the irradiation, the probe was placed on a conveyor belt that crosses the radiation fi eld of a 1.5 MeV electron beam. Results: The currents were registered as a function of the exposure time for dose-rates within 2-8 kGy/s and accumulated doses up to 350 kGy. The dosimeter was characterized with respect to the linearity between current and dose-rate, repeatability and reproducibility of the current signals. Its lifespan was investigated, particularly addressing the stability of the current sensitivity factor with increasing absorbed doses. The measurements were benchmarked against calculations of the current taking into account the fraction of the electron energy deposited in the active volume of the diode, the dose-rate, and the values of diffusion lengths. Conclusion: All experimental data so far obtained prove that this diode can be used in electron beam dosimetry. Furthermore, a fair agreement was found between theoretical and experimental results.

  • IPEN-DOC 29316

    BUENO, C.C. ; GONCALVES, J.A.C. ; MANGIAROTTI, A.. Dosimetric evaluation of an epitaxial silicon diode as an online dosimeter for orthovoltage photon beam radiotherapy. In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 15th, December 6-10, 2021, Kuala Lumpur, Malaysia. Abstract... 2021.

    Abstract: The response of a dosimetry system based on an epitaxial silicon diode as an online dosimeter for orthovoltage photon beam radiotherapy has been investigated in this work. To be used as a dosimeter, each diode is housed in a light-tight probe, and its readout electrode is directly connected to the Keithley 6517B electrometer. All current measurements are carried out in short-circuit mode with the diode unbiased and its backplane grounded. The data acquired by the electrometer are directly sent to a personal computer via a GBIP interface controlled by software developed in LabView to analyze the current signals. A Pantak/Seifert X-ray tube is used to irradiate the diode, placed 50.0 cm away in a radiation field of 8 cm, with 10, 25, 30, and 50 kV photons. The dose rate response is investigated for the 50 kV beam by varying the current tube from 2 to 20 mA. As expected, the induced current is linearly dependent on the dose rate within the range of 0.8 and 8.05 mGy/s. The current signals are quite stable, with a repeatability parameter of less than 0.2%. The dose-responses assessed offline by integrating the current signals are linear between 0.5 and 3.0 Gy despite being slightly dependent on the photon energy. However, in this dose range, no dose rate dependence is observed. These results are theoretically supported by dose and dose rate calculations performed assuming the diode is thin compared with the standard values of the minority carrier diffusion lengths in the epitaxial layer. Good agreement is found between calculations and experimental data. Investigations of possible radiation damage produced in the diode through dynamic measurements of dark current and capacitance as a function of the accumulated dose are currently in progress.

  • IPEN-DOC 07869

    FRAGA, M.M.; FERREIRA MARQUES, R.; IVANIOUCHENKOV, Y.; LIMA, E.P.; NEVES, F.; POLICARPO, A.J.P.L.; BUENO, C.C. ; GONCALVES, J.A.C. ; SANTOS, M.D.S.; COSTA, L.; MENDIRATTA, S.; MONTEIRO, J.H.. Dynamic behaviour in resistive detectors. In: REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 22., 8-12 set, 1999, Sao Lourenco, MG. Resumos... 1999. p. 48-49.

    Palavras-Chave: radiation detectors; proportional counters; counting rates; electrical properties; electric conductivity; permittivity; glass; relaxation

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.