Navegação por Autores IPEN "FUKUMORI, NEUZA T.O."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 17170

    OLIVEIRA, IDELI M. de ; MARTINS, PATRICIA de A. ; SILVA, JOSE L. da ; RAMOS, MARCELO P.S. ; LIMA, JOSE A.S. ; PUJATTI, PRISCILLA B.; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Alternative methods for radiochemical purity testing in radiopharmaceutical. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: radiopharmaceuticals; radiochemical analysis; impurities; thin-layer chromatography; high-performance liquid chromatography

  • IPEN-DOC 19150

    MOURA. REBECA G.; FUKUMORI, NEUZA T.O. ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. . Aplicação de contador gama com detector de Nal e radiocromatógrafo linear na avaliação de pureza radioquimica de radiofármacos. In: SIMPOSIO INTERNACIONAL DE INICIACAO CIENTIFICA DA USP, 19., 22 a 25 de novembro, 2011, São Carlos, SP. Resumo... 2011.

    Palavras-Chave: radiopharmaceuticals; impurities; technetium 99; gamma dosimetry; nai detectors; radiochemistry; chromatography

  • IPEN-DOC 23167

    FURUKAWA, CASSIA Y. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Avaliação da condição de transporte na estabilidade do bicisato (99m Tc) / Evaluation of the transportation condition on the stability of Technetium Tc 99m bicisate. Revista Brasileira de Farmácia, v. 98, n. 1, p. 1864-1875, 2017.

    Abstract: O radiofármaco de bicisato (99m Tc) é utilizado em cintilografia cerebral por SPECT para obtenção de imagens do fluxo sanguíneo cerebral em pacientes com anomalias do sistema nervoso central, tais como epilepsia, demência, acidente vascular cerebral e traumas. O objetivo deste trabalho foi avaliar a pureza radioquímica do bicisato (99m Tc) após simular uma condição de estresse no transporte do ECD-TEC (IPEN), colocando o reagente liofilizado por 48 horas em 40 oC e 75% umidade relativa. Foi feita a comparação da pureza radioquímica obtida com frascos do reagente liofilizado ECD-TEC mantidos por três meses em temperatura de 2 a 8 oC, com frascos colocados por 48 horas em câmara climática a 40 oC e 75% de umidade relativa, e com frascos mantidos sem controle de temperatura, e que foram marcados com eluato de pertecnetato de sódio. Os resultados de pureza radioquímica maiores que o limite especificado pelas farmacopeias em amostras analisadas imediatamente após a fabricação e em amostras submetidas às diferentes condições de temperatura e umidade indicaram que não houve alteração na estabilidade do produto, quando respeitados os cuidados especiais de marcação descritos na bula, recomendados pelo fabricante.

    Palavras-Chave: radiopharmaceuticals; radiochemistry; impurities; technetium; technetium 99

  • IPEN-DOC 12029

    FUKUMORI, NEUZA T.O. ; FERNANDES, ADRIANA V.; CAMPOS, DOMINGOS G. de ; GOMES, ANTONIO C. ; SILVA, NATANAEL G. da ; PEREIRA, NILDA P.S. de ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . A challenge for the validation of the gel clot test in radiopharmaceuticals produced in the radiopharmacy center. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: radiopharmaceuticals; endotoxins; gallium 67; thallium 201; infectivity; validation

  • IPEN-DOC 15119

    MONTEIRO, ELISIANE G.; ALMEIDA, ERIKA V.; RAMOS, MARCELO P.S. ; ALVES, EDSON V. ; BENEDETTI, STELLA; MENGATTI, JAIR ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Comparison of chromatography systems for radiochemical purity determination of lyophilized reagents labeled with technetium-99m. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: comparative evaluations; experimental data; impurities; labelling; quality control; radiochemistry; radiopharmaceuticals; technetium 99; thin-layer chromatography

  • IPEN-DOC 14325

    ALMEIDA, ERIKA V.; MONTEIRO, ELISIANE G.; ALVES, EDSON V. ; SILVA, NATANAEL G. da ; FUKUMORI, NEUZA T.O. ; BARBOZA, MARYCEL F. de ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. ; VASCONCELLOS, MARINA B.A. . Controle de qualidade e EC-sup(99m)Tc: determinacao de pureza radioquimica e investigacao da influencia de impurezas na biodistribuicao. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 14., 10-12 de outubro, 2009, Sao Paulo, SP. Anais... 2009.

    Palavras-Chave: chemical properties; diagnosis; diagnostic techniques; dynamic function studies; labelled compounds; radiopharmaceuticals; technetium 99; technetium; scintiscanning; tracer techniques

  • IPEN-DOC 15709

    ALMEIDA, ERIKA V.; MONTEIRO, ELISIANE G.; ALVES, EDSON V. ; SILVA, NATANAEL G. da ; FUKUMORI, NEUZA T.O. ; BARBOZA, MARYCEL F. de ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. ; VASCONCELLOS, MARINA B.A. . Controle de qualidade EC sup(99m)Tc: determinação de pureza radioquímica e investigação da influencia de impurezas na biodistribuição. Revista Brasileira de Fisica Medica, v. 4, n. 1, p. 71-74, 2010.

    Palavras-Chave: nuclear medicine; radiopharmaceuticals; technetium 99; radiochemistry; impurities; tissue distribution; biological localization; chromatography; quality control

  • IPEN-DOC 27747

    MARTINS, PATRICIA de A. ; SANTOS, JOEL M. dos; SILVA, JOSE L. da ; SILVA, LAERCIO da ; FUKUMORI, NEUZA T.O. ; ARAUJO, ELAINE B. de ; HIROMOTO, GORO ; MATSUDA, MARGARETH M.N. . Controle radionuclídico de radiofármacos de Lu-177. In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 34., 4-7 de setembro, 2020, Online. Resumo expandido... São Paulo, SP: Sociedade Brasileira de Medicina Nuclear, 2020.

    Abstract: O lutécio-177 (Lu-177) é um radioisótopo produzido em reator, com meia-vida física (t/) de 6,73 dias e decaimento por emissão beta de 498,3 keV e raios y energias de 208,37 keV e 112,9 keV, adequados para o tratamento de câncer de tumores neuroendócrinos e de próstata. A determinação da pureza radionuclídica de radiofármacos de lutécio-177 visa verificar se a porcentagem de radionuclídeos atendem aos critérios estabelecidos na Farmacopeia Europeia (FE). Este trabalho tem por objetivo estabelecer as condições para realizar o controle radionuclídico de DOT-IPEN-177 produzido no IPEN-CNEN/ SP. Os resultados de identificação e pureza radionuclídica de DOT-IPEN-177 encontrados foram satisfatórios pois atenderam aos critérios estabelecidos na FE.

  • IPEN-DOC 16614

    ALMEIDA, ERIKA V. de; FUKUMORI, NEUZA T.O. ; MENGATTI, JAIR ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . Desenvolvimento de método analítico por CLAE-RF para EC-sup(99m)Tc. In: SEMANA FARMACÊUTICA DE CIÊNCIA E TECNOLOGIA, 12., 13-17 de outubro, 2008, São Paulo, SP. Resumos... 2008. p. 73.

    Palavras-Chave: radiopharmaceuticals; ethylene; cysteine; technetium 99; kidneys; chromatography

  • IPEN-DOC 14327

    ALMEIDA, ERIKA V. de; FUKUMORI, NEUZA T.O. ; MONTEIRO, ELISIANE G. de; MENGATTI, JAIR ; BARBOZA, MARYCEL R.F.F. ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . Desenvolvimento e validacao de metodo analitico por CET para determinacao de SAH em radiofarmaco de sup(99m)Tc. In: CONGRESSO DA QUALIDADE EM METROLOGIA, 1-4 de junho, 2009, Sao Paulo, SP. Anais... 2009.

    Palavras-Chave: chromatography; validation; albumins; blood serum; radiopharmaceuticals; labelled compounds; technetium 99

  • IPEN-DOC 12338

    FUKUMORI, NEUZA T.O. . Determinação de endotoxina bacteriana (pirogênio) em radiofármacos pelo método de formação de gel. Validação / Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation . 2008. Dissertação (Mestrado) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 77 p. Orientador: Constancia Pagano Goncalves da Silva. DOI: 10.11606/D.85.2008.tde-13102011-144714

    Abstract: Antes do Ensaio do Lisado de Amebócitos do Limulus (LAL), a única forma de se avaliar a pirogenicidade em drogas parenterais e dispositivos médicos era o ensaio de pirogênio em coelhos da Farmacopéia Americana (USP). Especialmente para radiofármacos, o ensaio LAL é a escolha para a determinação de endotoxina bacteriana (pirogênio). O objetivo deste trabalho foi validar o método de formação de gel para alguns radiofármacos sem uma interferência mensurável. O guia do método LAL do Food and Drug Administration (FDA) define interferência como uma condição que causa uma diferença significativa entre os pontos finais de gelificação das séries de controle positivo da água e controle positivo do produto utilizando-se um endotoxina padrão. Os experimentos foram realizados de acordo com o teste de endotoxinas bacterianas da USP na m-iodobenzilguanidina-131I, nos radioisótopos Gálio-67 e Tálio-201, nos reagentes liofilizados DTPA, Fitato, GHA, SAH e Sn Coloidal. A Máxima Diluição Válida (MDV) foi calculada para cada produto com base na sua dose clínica e diluições seriadas abaixo da MDV foram avaliadas em duplicata para a detecção de interferências. A sensibilidade declarada do reagente de LAL foi de 0,125 UE mL-1 (Unidades de Endotoxina por mililitro). Para a validação, uma série de diluições foi feita utilizando-se padrão de endotoxina (PE) nas concentrações de 0,5 a 0,03 UE mL-1 para a confirmação da sensibilidade do reagente de LAL, em quadruplicata. A mesma série de diluições foi feita com o PE e o produto diluído 100 vezes em três lotes consecutivos de cada radiofármaco. Os produtos m-iodobenzilguanidina-131I, Gálio-67, Tálio-201, DTPA, SAH e Sn Coloidal foram compatíveis com o método no fator de diluição 1:100. Fitato e GHA apresentaram interferência no ensaio de formação de gel. Outras técnicas para determinar endotoxinas como o ensaio cromogênico (desenvolvimento de cor) e o turbidimétrico (desenvolvimento de turbidez) foram avaliadas para obter informações qualitativas e quantitativas sobre as concentrações de endotoxinas nas amostras.

    Palavras-Chave: pyrogens; radiopharmaceuticals; validation

  • IPEN-DOC 27748

    SILVA, JOSE L. da ; MARTINS, PATRICIA de A. ; SANTOS, JOEL M. dos; SILVA, LAERCIO da ; SILVA, NATANAEL G. da ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Determinação de estanho total por ICP-OES em reagentes liofilizados. In: CONGRESSO BRASILEIRO DE MEDICINA NUCLEAR, 34., 4-7 de setembro, 2020, Online. Resumo expandido... São Paulo, SP: Sociedade Brasileira de Medicina Nuclear, 2020.

    Abstract: O tecnécio-99m (99mTc) é o radioisótopo mais utilizado na medicina nuclear para obtenção de imagens para diagnóstico por SPECT. Seu estado de oxidação pode variar de -1 a +7, quando reage com uma variedade de compostos na presença de Sn(II).O cloreto estanoso diidratado é o agente redutor do 99mTc mais utilizado na formulação de reagentes liofilizados(RL). A determinação quantitativa de estanho total e Sn(II) são controles importantes para o processo de fabricação a fim de garantir a qualidade durante o prazo de validade dos RL. O objetivo deste trabalho foi quantificar o Sn total nos RL MDP-TEC e MIBI-TEC (IPEN) usando ICP-OES como método alternativo ao método colorimétrico descrito nas farmacopeias. As massas quantificadas de cloreto estanoso nos RL analisados estiveram compreendidas entre 90-110 % em relação ao descrito na bula do radiofármaco. O método analítico proposto por ICP-OES mostrou-se excelente para determinação de Sn total.

  • IPEN-DOC 16613

    ALMEIDA, ERIKA V. de; FUKUMORI, NEUZA T.O. ; BARBOZA, MARYCEL R.F.F. ; MENGATTI, JAIR ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . Determinação de SAH em radiofármaco de 99mTc por cromatografia por exclusão de tamanho. Validação. In: CONGRESSO LATINO-AMERICANO DE CROMATOGRAFIA E TÉCNICAS RELACIONADAS, 12., 28-30 de outubro, 2008, Florianópolis, SC. Resumos... 2008. p. 624.

    Palavras-Chave: blood serum; albumins; radiopharmaceuticals; chromatography; validation

  • IPEN-DOC 19252

    MARTINS, PATRICIA de A. ; MOURA, REBECA G.; SHIKI, ANDRESSA M.; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Determination of radiochemical yield of sup(99m)Tc radiopharmaceutical preparations using gamma counter and linear radiochromatography scanner. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: technetium 99; radiochemistry; gamma detection; radiochromatography; radioisotope scanners

  • IPEN-DOC 22643

    PORTO, LUCIANA V.F.M. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Determination of the worst case for cleaning validation of equipment used in the radiopharmaceutical production of lyophilized reagents for sup(99)Tc labeling. Brazilian Journal of Pharmaceutical Sciences, v. 52, n. 1, p. 105-112, 2016. DOI: 10.1590/S1984-82502016000100012

    Abstract: Cleaning validation, a requirement of the current Good Manufacturing Practices (cGMP) for Drugs, consists of documented evidence that cleaning procedures are capable of removing residues to predetermined acceptance levels. This report describes a strategy for the selection of the worst case product for the production of lyophilized reagents (LRs) for labeling with 99mTc from the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/São Paulo). The strategy is based on the calculation of a “worst case index” that incorporates information about drug solubility, cleaning difficulty, and occupancy rate in the production line. It allowed a reduction in the required number of validations considering the possible manufacturing flow of a given product and the subsequent flow, thus facilitating the process by reducing operation time and cost. The products identified as “worst case” were LRs PUL-TEC and MIBI-TEC.

    Palavras-Chave: cleaning; validation; equipment; radiopharmaceuticals; production; lyophilization; reagents; technetium isotopes; labelling; drugs; fabrication

  • IPEN-DOC 26239

    SILVA, VITOR M.A. da ; SOUSA, JURANDIR A. de ; MARTINS, PATRICIA de A. ; FUKUMORI, NEUZA T.O. ; SILVA, NATANAEL G. da ; MATSUDA, MARGARETH M.N. . Dose calibrator and gamma counter: comparison of results in MIBI-TEC® biological distribution. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1860-1864.

    Abstract: To ensure that pharmaceutical products have and maintain the structure, identity, purity, concentration, potency and safety characteristics required for their use, there is a set of standard procedures called Good Manufacturing Practices (GMP). In Brazil, the National Sanitary Surveillance Agency (ANVISA) regulates the GMP production of medicines through RDC17/2010 and for radiopharmaceuticals through RDC 63/2009 and 38/2008, to ensure their safe and correct use in commercial production and nuclear medicine services, respectively. Most 99mTc radiopharmaceutical monographs have biological distribution specifications. Using invasive method, 99mTcradiopharmaceuticalsare assessed by the injection into animals of defined strains and the radioactivity (as percentage of retainedor injected dose -%RDor%ID)ismeasured in specified organs. Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; MIBI-TEC®) monograph is related in USP 41, but the biological distribution assay is not included. At IPEN, the biodistribution test is performed as established in the Radiopharmaceutical Quality Control Manual of ARCAL XV (1999) - International Atomic Energy Agency (IAEA), for each batch. The objective of this work is to compare MIBI-TEC®biodistribution results using dose calibrator and gamma counter with sodium iodide detector by measuring the radioactivity in the organs. Three batches of MIBI-TEC®were used and 1 vial of lyophilized reagent (LR) was labeled with 5-10 mCiin 1-3 mL of 99mTc eluate. 200-300 μCi in 0.2 mLwereinjected in 3 Balb-Cmice. After 30 minutes of biodistribution, heart, lung, muscle, liver, paw, column and tail were withdrawn, weighed and radioactivity was measured in dose calibrator and gamma counter (μCi andcpm, respectively). %ID/g ratio in the organs of interest was calculated using the data obtained by both equipment and the results were compared. No significant differences were observed and it was possible to conclude that either a dose calibrator or a gamma counter can be used in the routine of quality control.

    Palavras-Chave: calibration; comparative evaluations; quality control; radiation detectors; radiation dose distributions; radiation doses; radioactivity; radiopharmaceuticals; sodium iodides; technetium 99

  • IPEN-DOC 15117

    ALMEIDA, ERIKA V.; MONTEIRO, ELISIANE G.; MENGATTI, JAIR ; FUKUMORI, NEUZA T.O. ; SILVA, CONSTANCIA P.G. ; MATSUDA, MARGARETH M.N. . Effect of mobile phase on the RP-HPLC analysis of sup(99m)Tc-ECD. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: brain; chemical preparation; cysteine; ethanol; ethylene; experimental data; high-performance liquid chromatography; impurities; ph value; phosphates; radiochemistry; radiopharmaceuticals; reagents; retention; technetium 99

  • IPEN-DOC 12086

    MARTINS, PATRICIA de A. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. ; VICENTE, IRENE ; SILVA, LAERCIO ; EVEDOVE, SUELI D. ; MURAMOTO, EMIKO . Equivalence of the blockage of ureter and the action of the urethane in sup(99m)Tc-DMSA biodistribution in rats. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: biological localization; intravenous injection; radionuclide kinetics; radiopharmaceuticals; rats; technetium 99; ureters; urethane

  • IPEN-DOC 20927

    FUKUMORI, NEUZA T.O. . Estudo da influência da atividade radioativa presente no gerador de sup(99)Mo/sup(99m)Tc na esterilidade do produto terminado / Study of influence of sup(99)Mo/sup(99m)Tc generator radioactivity on the sterility of the finished product . 2015. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 160 p. Orientador: Margareth Mie Nakamura Matsuda. DOI: 10.11606/T.85.2015.tde-19082015-093444

    Abstract: No processo de fabricação do gerador de 99Mo/99mTc é fundamental, não só evitar a introdução de contaminantes microbianos, como também avaliar o efeito que a atividade radioativa pode provocar em microrganismos. Os objetivos deste trabalho foram: estudar os processos de esterilização por radiação gama (60Co) dos acessórios e da coluna de alumina (Al2O3) que compõem o sistema do gerador de 99Mo/99mTc, e avaliar a eficácia da radiação gama na morte de microrganismos em geradores de 99Mo/99mTc na mínima (9,25 GBq) e na máxima (74 GBq) atividade radioativa. Acessórios do gerador foram irradiados com doses absorvidas de 15, 25 e 50 kGy e as colunas de alumina com 10, 15, 25 e 50 kGy. A alumina das colunas irradiadas foi avaliada por análise combinada de microscopia eletrônica de varredura (MEV) e análise elementar por espectroscopia de energia dispersiva (EDS), e difração de raios X. O Teflon® foi avaliado por termogravimetria (TGA) e calorimetria exploratória diferencial (DSC). Cálculos dosimétricos foram realizados para o alvo de maior dose na coluna do gerador de 9,25 GBq e 74 GBq. Suspensões quantificadas de B. subtilis e esporos de B. pumilus foram inoculadas em colunas irradiadas a 25 kGy e observou-se que a coluna de alumina representou uma barreira física para a contaminação do eluato, pois a recuperação microbiana foi reduzida. Verificou-se que o B. subtilis na forma vegetativa mostrou menor afinidade pela alumina em relação aos esporos de B. pumilus. A recuperação microbiana foi menor no gerador com atividade radioativa em relação ao gerador sem radioatividade. Foi desenvolvido um indicador biológico de esporos de B. pumilus que consistiu em uma tira de alumínio com sílica gel colocado externamente à coluna e as quantidades recuperadas tanto no gerador de 9,25 GBq quanto no de 74 GBq mostraram redução na viabilidade. O uso de filtros Sep-Pak® e 0,22 μm no sistema do gerador mostrou eficiência na retenção de 4,9 x 106 UFC de B. subtilis, garantindo a esterilidade do produto terminado.

    Palavras-Chave: radiopharmaceuticals; molybdenum 99; technetium 99; radioisotope generators; ionizing radiations; radiation effects; sterility; sterilization; microorganisms

  • IPEN-DOC 19151

    CAUMO, SOFIA E.S.; FUKUMORI, NEUZA T.O. ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. . Estudo de interferência na análise de endotoxina bacteriana em radiofármacos de sup(99m)Tc pelo método de formação de gel. In: SIMPOSIO INTERNACIONAL DE INICIACAO CIENTIFICA DA USP, 19., 22 a 25 de novembro, 2011, São Carlos, SP. Resumo... 2011.

    Palavras-Chave: radiopharmaceuticals; technetium 99; reagents; lyophilization; endotoxins; bacteria; gels; quality control

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.