Navegação por Autores IPEN "YORIYAZ, HELIO"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 27125

    BELLEZZO, MURILLO ; FONSECA, GABRIEL P.; VONCKEN, ROBERT; VERRIJSSEN, AN-SOFIE; VAN BEVEREN, CELINE; ROELOFS, ERIK; YORIYAZ, HELIO ; RENIERS, BRIGITTE; VAN LIMBERGEN, EVERT J.; BERB EE, MAAIKE; VERHAEGEN, FRANK. Advanced design, simulation, and dosimetry of a novel rectal applicator for contact brachytherapy with a conventional HDR 192Ir source. Brachytherapy, v. 19, n. 4, p. 544-553, 2020. DOI: 10.1016/j.brachy.2020.03.009

    Abstract: PURPOSE: Dose escalation yields higher complete response to rectal tumors, which may enable the omission of surgery. Dose escalation using 50 kVp contact x-ray brachytherapy (CXB) allow the treatment of a selective volume, resulting in low toxicity and organs-at-risk preservation. However, the use of CXB devices is limited because of its high cost and lack of treatment planning tools. Hence, the MAASTRO applicator (for HDR 192Ir sources) was developed and characterized by measurements and Monte Carlo simulations to be a cost-effective alternative to CXB devices. METHODS AND MATERIALS: A cylindrical applicator with lateral shielding was designed to be used with a rectoscope using its tip as treatment surface. Both the applicator and the rectoscope have a slanted edge to potentially allow easier placement against tumors. The applicator design was achieved by Monte Carlo modeling and validated experimentally with film dosimetry, using the Papillon 50 (P50) device as reference. RESULTS: The applicator delivers CXB doses in less than 9 min using a 20375 U source for a treatment area of approximately 20 20 mm2 at 2 mm depth. Normalized at 2 mm, the dose falloff for depths of 0 mm, 5 mm, and 10 mm are 130%, 70%, and 43% for the P50 and 140%, 67%, and 38% for the MAASTRO applicator, respectively. CONCLUSIONS: The MAASTRO applicator was designed to use HDR 192Ir sources to deliver a dose distribution similar to those of CXB devices. The applicator may provide a cost-effective solution for endoluminal boosting with clinical treatment planning system integration.

    Palavras-Chave: brachytherapy; monte carlo method; rectal administration; iridium 192; dose rates; radiation sources; simulation; radiotherapy; neoplasms; film dosimetry

  • IPEN-DOC 17142

    COELHO, TALITA S.; MASSICANO, FELIPE; POSSANI, RAFAEL G.; FEDORENKO, GIULIANA; VIANA, RODRIGO S.; CASTRO, VINICIUS A.; FERNANDES, MARCO A.R.; MIOT, HELIO A.; YORIYAZ, HELIO . Algorithm development for dermoscopic images analysis of skin lesion. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: epitheliomas; melanomas; diagnostic techniques; biopsy; algorithms; computer codes

  • IPEN-DOC 28453

    MAZER, AMANDA C. ; YORIYAZ, HELIO . Algoritmo para avaliação de registro de imagem baseado na técnica SIFT (Scale Invariant Feature Transform). In: CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 25., 19-23 de abril, 2021, Online. Resumo... 2021.

    Observação: Vídeo de apresentação: https://youtu.be/k1405XduFEo

    Abstract: A avaliação de um registro de imagem deve ser feita a partir de um grande número de pontos distribuídos pelas imagens utilizadas no processo. Neste trabalho, a técnica SIFT, que permite extrair automaticamente pontos estáveis de uma imagem, foi utilizada para desenvolver um algoritmo na linguagem Python para ser aplicado para avaliação de registro de imagens médicas 3D. Imagem de TC (tomografia computadorizada) foi usada para realizar testes de redundância envolvendo diferentes transformações, a fim de obter pontos correspondentes entre a imagem original e a imagem sintética transformada. Para todos os testes, o algoritmo foi capaz de identificar pontos estáveis, em que a maioria era verdadeiramente correspondente, de acordo com diferentes margens de erro. Entretanto, o algoritmo ainda se encontra em fase de validação.

  • IPEN-DOC 17278

    COELHO, TALITA S.; FERNANDES, MARCO A.R.; YORIYAZ, HELIO ; LOUZADA, MARIO J.Q.. Analise dosimétrica de perfis de distribuições radiais de doses relativas de um aplicador de betaterapia de sup(90)Sr+sup(90)Y utilizando o código MCNP-4C e filmes radiocrônicos. Revista Brasileira de Fisica Medica, v. 4, n. 3, p. 7-10, 2011.

    Palavras-Chave: beta dosimetry; dose equivalents; dosimetry; films; m codes; measuring methods; radiation detection; radiation dose distributions; radiation dose units; radiation doses; radiation monitoring; radiation protection; radiations; strontium; strontium 90; yttrium; yttrium 90

  • IPEN-DOC 14098

    MASSICANO, FELIPE; MASSICANO, ADRIANA V.F.; SILVA, NATANAEL G. ; CINTRA, FELIPE B.; CARVALHO, RODRIGO M.; YORIYAZ, HELIO . Analysis of ct and pet/spect images for dosimetry calculation. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: animal tissues; density; dosimetry; gamma cameras; i codes; images; m codes; monte carlo method; numerical data; positron computed tomography; single photon emission computed tomography

  • IPEN-DOC 15001

    FONSECA, GABRIEL P.; YORIYAZ, HELIO ; SIQUEIRA, PAULO T.D. ; ANTUNES, PAULA C.G.; FURNARI, LAURA; SANTOS, GABRIELA R.. Analysis of material characteristics for the construction of energy degrading and scattering plates for electron beam akin radiotherapy. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: aluminium; copper; depth dose distributions; electron beams; energy spectra; experimental data; linear accelerators; lymphomas; m codes; monte carlo method; plates; radiation doses; radiotherapy; skin diseases; skin

  • IPEN-DOC 27940

    MAZER, AMANDA C. ; SHORTO, JULIAN M.B. ; SIQUEIRA, PAULO T.D. ; NAKANDAKARI, MARCOS V.N.; RIBEIRO, VICTOR A.B.; YORIYAZ, HELIO . Análise da sensibilidade do ArcCHECK® / ArcCHECK® sensitivity analysis. In: CONGRESSO BRASILEIRO DE FÍSICA MÉDICA, 24., 21-24 de agosto, 2019, Santos, SP. Anais... São Paulo, SP: Associação Brasileira de Física Médica, 2019. p. 1-5.

    Abstract: Este artigo apresenta uma análise da sensibilidade do sistema dosimétrico ArcCHECK, através de comparações entre medidas experimentais envolvendo alguns tipos de deslocamentos mecânicos e medidas de uma referência fixa. O ArcCHECK é um sistema que contém 1386 diodos dispostos de forma helicoidal e que permite realizar medições para Controle de Qualidade de técnicas de radioterapia mais modernas e complexas. Foram feitas algumas medidas iniciais de repetibilidade e de linearidade e, em sequência, análises da capacidade do dispositivo em identificar erros de deslocamentos em diferentes direções, bem como a visualização de efeitos da resolução dos diodos. Foram encontradas diferenças consideráveis nos valores de dose entre deslocamentos pequenos e a referência. Também foram observadas deformações nas curvas de isodose para determinados ângulos de irradiação do sistema. O ArcCHECK foi considerado bastante sensível, dada a metodologia de análise, porém deve ser utilizado com cautela quando posicionado para realizar Controle de Qualidade.

    Palavras-Chave: dosimetry; equipment; irradiation; isodose curves; quality assurance; radiation dose distributions; radiotherapy

  • IPEN-DOC 17914

    CORREA, SAMANDA C.A.; SOUZA, EDMILSON M. de; SILVA, ADEMIR X. da; YORIYAZ, HELIO ; LOPES, RICARDO T.. AP and PA thorax radiographs: dose evaluation using the FAX phantom. International Journal of Low Radiation, v. 5, n. 3, p. 237-255, 2008.

    Palavras-Chave: chest; images; monte carlo method; simulation; females; adults; phantoms; radiation doses

  • IPEN-DOC 29150

    MAZER, AMANDA C. ; YORIYAZ, HELIO . Avaliação de registro de imagem realizado com e sem pontos de referência extraídos através da técnica SIFT. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 26th; CONGRESSO LATINO-AMERICANO DE FISICA MEDICA, 9th, June 8-11, 2022, Fortaleza, CE. Abstract... São Paulo, SP: Associação Brasileira De Física Médica, 2022.

    Abstract: Em Radioterapia Guiada por Imagem (IGRT), é comum a aquisição de diversas imagens de um paciente e, por consequência, a realização de registro de imagem para a comparação entre elas. Devido a isso, é fundamental que sejam realizados tanto um bom registro quanto um bom controle da qualidade (CQ) do registro. O objetivo deste trabalho é avaliar um registro de imagem quando realizado com e sem pontos de referência. Para isso, imagens de Tomografia Computadorizada (TC) de um paciente da radioterapia foram utilizadas para realizar registros rígido e elástico, com e sem pontos de referência. A técnica Scale Invariant Feature Transform (SIFT) foi utilizada para desenvolver um algoritmo para a extração semi-automática de pontos-chave estáveis das imagens, tanto para os registros quanto para a avaliação de tais registros. Através dos valores de erro médio, erro máximo e Informação Mútua (IM) encontrados, foi possível verificar um melhor alinhamento das imagens quando realizado o registro partindo inicialmente dos pontos de referência extraídos, em comparação com o alinhamento realizado sem esses pontos de referência. A SIFT mostrou ser uma ótima ferramenta para realizar ambas as tarefas e, quando possível, o profissional da clínica deve realizar um bom CQ quantitativo de registro, considerando pontos de referência distribuídos pelas imagens.

  • IPEN-DOC 29515

    MAZER, AMANDA C. ; YORIYAZ, HELIO . Avaliação de registro de imagem realizado com e sem pontos de referência extraídos através da técnica SIFT / Image registration assessment performed with and without landmarks extracted using SIFT technique. Revista Brasileira de Física Médica, v. 16, p. 1-8, 2022. DOI: 10.29384/rbfm.2022.v16.19849001676

    Abstract: Em Radioterapia Guiada por Imagem (IGRT), é comum a aquisição de diversas imagens de um paciente e, por consequência, a realização de registro de imagem para a comparação entre elas. Devido a isso, é fundamental que sejam realizados tanto um bom registro quanto um bom controle da qualidade (CQ) do registro. O objetivo deste trabalho é avaliar um registro de imagem quando realizado com e sem pontos de referência. Para isso, imagens de Tomografia Computadorizada (TC) de um paciente da radioterapia foram utilizadas para realizar registros rígido e elástico, com e sem pontos de referência. A técnica Scale Invariant Feature Transform (SIFT) foi utilizada para desenvolver um algoritmo para a extração semiautomática de pontos-chave estáveis das imagens, tanto para os registros quanto para a avaliação de tais registros. Através dos valores de erro médio, erro máximo e Informação Mútua (IM) encontrados, foi possível verificar um melhor alinhamento das imagens quando realizado o registro partindo inicialmente dos pontos de referência extraídos, em comparação com o alinhamento realizado sem esses pontos de referência. A SIFT mostrou ser uma ótima ferramenta para realizar ambas as tarefas e, quando possível, o profissional da clínica deve realizar um bom CQ quantitativo de registro, considerando pontos de referência distribuídos pelas imagens.

  • IPEN-DOC 29690

    BULL, HENRIQUE C.; RIBEIRO NETO, MARIO; MAISTRO, CARLOS EDUARDO B.; YORIYAZ, HELIO ; SAMPAIO, CAROLINE C.. Avaliação dosimétrica de erros de posicionamento para implementação da técnica de neuroeixo com arcoterapia volumétrica modulada (VMAT) / Dosimetric Evaluation of Setup Errors for Clinical Implementation of Volumetric Modulated Arc Therapy Technique for Craniospinal Irradiation. Revista Brasileira de Física Médica, v. 17, n. 649, p. 1-8, 2023. DOI: org/10.29384/rbfm.2023.v17.19849001649

    Abstract: Este trabalho avaliou retrospectivamente correções de imagens planares de pacientes já submetidos a tratamentos de neuroeixo, a fim de quantificar a magnitude dos erros de posicionamento e aplicá-los em diferentes técnicas de radioterapia em arco modulada volumetricamente (VMAT) para definir a que possui o menor impacto dosimétrico considerando estes erros, para implementação na prática clínica, que é objetivo deste estudo. Ao todo 219 imagens planares de 15 pacientes foram selecionadas para avaliação estatística de erros de posicionamento. Para os planejamentos, quatro pacientes pediátricos já tratados com técnica 3D conformacional foram selecionados. Para cada um, cinco planos de tratamento VMAT foram otimizados em duas técnicas: sobreposição com 3 cm, 6 cm e 9 cm de junção e gradiente com 6 cm e 9 cm e foram avaliados pelos índices: V100%, V95%, D98%, D2%, número de conformidade (CN) e índice de heterogeneidade (HI). Em cada plano, foram inseridos erros de posicionamento com a magnitude encontrada na análise retrospectiva das imagens, bem como avaliar a diferença na distribuição de dose quando considerado a mesa de tratamento. As imagens demonstraram deslocamentos médios entre 1 e 5 mm e em alguns casos chegando à 15 mm. Em relação à qualidade dos planejamentos, todos obtiveram resultados coerentes baseados nas métricas avaliadas sem diferenças significativas. Porém, a técnica de gradiente (9 cm de junção) reduziu o impacto dosimétrico em comparação às outras técnicas quando submetida aos erros de posicionamento. Por fim, ao considerar a mesa de tratamento nos planejamentos, foi encontrada uma redução de 10% no V100%. Os resultados mostraram que para implementação da técnica VMAT para neuroeixo recomenda-se realizar imagem de posicionamento diária para minimizar erros de posicionamento com magnitudes maiores que a média encontrada de 3 mm no sentido longitudinal, pois estes têm impacto significativo na distribuição de dose nos planejamentos modulados.

    Palavras-Chave: neoplasms; tumor cells; radiotherapy; nuclear medicine; physics

  • IPEN-DOC 15556

    YOSHIZUMI, MAIRA T.; YORIYAZ, HELIO ; CALDAS, LINDA V.E. . Backscattered radiation into a transmission ionization chamber: measurement and Monte Carlo simulation. Applied Radiation and Isotopes, v. 68, n. 4-5, p. 586-588, 2010.

    Palavras-Chave: accuracy; backscattering; collimators; ionization chambers; monitors; monte carlo method; transmission; x radiation

  • IPEN-DOC 13362

    YOSHIZUMI, MAIRA T.; YORIYAZ, HELIO ; CALDAS, LINDA V.E. . Backscattered radiation into a transmission ionization chamber: measurement and Monte Carlo simulation. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 7th, June 22-27, 2008, Praga, Republica Tcheca. Proceedings... 2008.

    Palavras-Chave: accuracy; backscattering; collimators; ionization chambers; monitors; monte carlo method; transmission; x radiation

  • IPEN-DOC 21130

    COSTA, PRISCILA ; RAELE, MARCUS P. ; YORIYAZ, HELIO ; SIQUEIRA, PAULO de T.D. ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Boron film thickness determination to develop a low cost neutron using Monte Carlo Method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: boron; thin films; monte carlo method; neutron flux; neutron detection; alpha particles; thermal neutrons; charged particles; computerized simulation; photodiodes; silicon; thickness

  • IPEN-DOC 19392

    FONSECA, GABRIEL P.; ANTUNES, PAULA C.G.; RENIERS, BRIGITTE; YORIYAZ, HELIO ; VERHAEGEN, FRANK. A brachytherapy model-based dose calculation algorithm - AMIGOBrachy. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: algorithms; brachytherapy; computer codes; dose rates; iridium 192; monte carlo method; phantoms; planning; radiation doses

  • IPEN-DOC 20609

    FONSECA, GABRIEL P. ; LUVIZOTTO, JESSICA ; COELHO, TALITA S. ; ANTUNES, PAULA C.G. ; RUBO, RODRIGO; SIQUEIRA, PAULO de T.D. ; YORIYAZ, HELIO . Brachytherapyu dose measurements in heterogeneous tissues. In: INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY , 14th, April 13-16, 2014, Cusco, Peru. Proceedings... 2014. p. 176-188.

    Palavras-Chave: brachytherapy; iridium 192; radiation doses; dosimetry; phantoms; simulation; monte carlo method; animal tissues

  • IPEN-DOC 27731

    MENDES, BRUNO M.; ANTUNES, PAULA C.G. ; BRANCO, ISABELA S.L. ; NASCIMENTO, EDUARDO do; SENIWAL, BALJEET; FONSECA, TELMA C.F.; YORIYAZ, HELIO . Calculation of dose point kernel values for monoenergetic electrons and beta emitting radionuclides: intercomparison of Monte Carlo codes. Radiation Physics and Chemistry, v. 181, p. 1-8, 2021. DOI: 10.1016/j.radphyschem.2020.109327

    Abstract: Targeted radionuclide therapy (TRT) and beta-emitting seeds brachytherapy (BSBT) exploit the characteristics of energy deposited by beta-emitting radionuclides. Monte Carlo (MC) modelling of electron transport is crucial for calculations of absorbed dose for TRT and BSBT. However, computer codes capable of providing consistent results are still limited. Since experimental validations show several difficulties, the estimation of electron dose point kernel (DPK) is often used to verify the accuracy of different MC codes. In this work, we compared DPK calculations for various point, isotropic and monoenergetic electron sources and several beta-emitting radioisotopes using the codes MCNP, EGSnrc, PENELOPE and TOPAS with different simulation options. The simulations were performed using latest versions of EGSnrc and Penelope, TOPAS version 3.3.1 and MCNP version 6.1 Monte Carlo codes. In our simulations, the geometrical model consists of a point electron source placed at the center of a water sphere emitting isotropically. The water sphere was divided into 28 shells and the energy deposition was scored within these shells. The radius of the outermost shell was 1.2R0, where R0 is the continuous slowing down approximation (CSDA) range. Five monoenergetic beta sources with energies of 0.05, 0.1, 0.5, 1 and 3 MeV were studied. Six beta-emitting radionuclides were also simulated: Lu-177, Sm-153, Ho-166, Sr-89, I-131 and Y-90. Monoenergetic electron simulations showed large deviations among the codes, larger than 13% depending on the electron energy and the distance from the source. In the cases where beta spectra of radionuclides were simulated, all MC codes showed differences from EGSnrc (used as reference value - RV) less than 3% within rE90 range (radius of the sphere in which 90% of the energy of the spectrum electrons would be deposited). TOPAS showed results comparable to EGSnrc and PENELOPE. DPK values for 0.1 MeV monoenergetic electrons, calculated using MCNP6, led to differences higher than ±5% from RV despite our attempts to tune electron transport algorithms and physics parameters.

    Palavras-Chave: point kernels; computer calculations; computerized simulation; electron emission; electrons; beta particles; radionuclides; monte carlo method; therapy; brachytherapy

  • IPEN-DOC 19919

    COELHO, TALITA S. ; FERNANDES, MARCO A.R.; YORIYAZ, HELIO ; GIGLIOLI, MILENA . Cálculo da não-uniformidade e assimetria de um aplicador de betaterapia de sup(90)sr+sup(90)Y baseados na norma NCS. In: CONGRESSO DE FISICA APLICADA EM MEDICINA, 7., 29 de setembro - 2 de outubro, 2010, Botucatu, SP. Anais... 2010.

    Palavras-Chave: asymmetry; radiation sources; strontium 90; yttrium 90; recommendations

  • IPEN-DOC 16945

    FONSECA, GABRIEL P.; YORIYAZ, HELIO ; ANTUNES, PAULA C.G.; SIQUEIRA, PAULO T.D. ; RUBO, RODRIGO; MINAMISAWA, RENATO A.; FERREIRA, LOUISE A.. Characterization of HDT Ir-192 source for 3D planning system. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: brachytherapy; iridium 192; radiation source implants; three-dimensional calculations; simulation; m codes

  • IPEN-DOC 21137

    ROCHA, MARCELO S. ; CABRAL, EDUARDO L.L. ; SABUNDJIAN, GAIANE ; YORIYAZ, HELIO ; LIMA, ANA C.S.; BELCHIOR JUNIOR, ANTONIO ; PRADO, ADELK C. ; MADI FILHO, TUFIC ; ANDRADE, DELVONEI A. ; SHORTO, JULIAN M.B. ; MESQUITA, ROBERTO N. ; OTUBO, LARISSA ; BAPTISTA FILHO, BENEDITO D. ; PINHO, PRISCILA G.M.; RIBATSKY, GHERHARDT; MORAES, ANDERSON A.U. de. Characterization of physical properties of Alsub(2)Osub(3) and ZrOsub(2) nanofluids for heat transfer applications. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: aluminium oxides; zirconium oxides; physical properties; nanofluids; viscosity; cooling; heat transfer; scanning electron microscopy

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.