Navegação por Autores IPEN "ZEITUNI, C.A."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 19817

    MOURA, E.S.; ZEITUNI, C.A. ; SAKURABA, R.K.; GONCALVES, V.D.; CRUZ, J.C.; JUNIOR, D.K.; SOUZA, C.D.; ROSTELATO, M.E.C.M. . Absorbed dose simulations in near-surface regions using high dose rate iridium-192 sources applied for brachytherapy. Radiation Physics and Chemistry, v. 95, p. 299-301, 2014.

    Palavras-Chave: absorbed radiation doses; beta particles; brachytherapy; cobalt 60; computerized simulation; depth dose distributions; iridium 192; mammary glands; monte carlo method; pmma; prostate; surfaces

  • IPEN-DOC 09337

    CASTANHEIRA, M. ; TERREMOTO, L.A.A. ; SILVA, J.E.R. ; ZEITUNI, C.A. . Analise da degradacao de barras absorvedoras de neutrons de Ag-In-Cd. Parte 1: deplecao da liga, efetividade de absorcao de neutrons e propriedades mecanicas. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 2, p. 362-368, 2002.

    Palavras-Chave: iear-1 reactor; control elements; neutron absorbers; silver alloys; indium alloys; cadmium alloys; inspection; mechanical properties

  • IPEN-DOC 08680

    CASTANHEIRA, M. ; TERREMOTO, L.A.A. ; SILVA, J.E.R. ; ZEITUNI, C.A. . Analise da degradacao de barras absorvedoras de neutrons de Ag-In-Cd. Parte 1: deplecao da liga, efetividade de absorcao de neutrons e propriedades mecanicas. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING OF REACTOR PHYSICS AND THERMAL HYDRAULICS, 13th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: iear-1 reactor; control elements; neutron absorbers; silver alloys; indium alloys; cadmium alloys; inspection; mechanical properties

  • IPEN-DOC 09338

    CASTANHEIRA, M. ; ZEITUNI, C.A. ; SILVA, J.E.R. ; TERREMOTO, L.A.A. . Analise da degradacao de barras absorvedoras de neutrons de Ag-In-Cd. Parte 2: comportamento quanto a corrosao e contaminacao da agua do reator. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 2, p. 369-374, 2002.

    Palavras-Chave: iear-1 reactor; control elements; neutron absorbers; silver alloys; indium alloys; cadmium alloys; nickel; coatings; inspection; corrosion; water; contamination

  • IPEN-DOC 08681

    CASTANHEIRA, M. ; ZEITUNI, C.A. ; SILVA, J.E.R. ; TERREMOTO, L.A.A. . Analise da degradacao de barras absorvedoras de neutrons de Ag-In-Cd. Parte 2: comportamento quanto a corrosao e contaminacao da agua do reator. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING OF REACTOR PHYSICS AND THERMAL HYDRAULICS, 13th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: iear-1 reactor; control elements; neutron absorbers; silver alloys; indium alloys; cadmium alloys; nickel; coatings; inspection; corrosion; water; contamination

  • IPEN-DOC 06568

    SILVA, J.E.R. ; PERROTTA, J.A. ; TERREMOTO, L.A.A. ; ZEITUNI, C.A. . Analise nao destrutiva de combustiveis irradiados na piscina do Reator IEA-R1m. In: 7o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 31 de agosto - 3 de setembro, 1999, Belo Horizonte, MG. 1999.

    Palavras-Chave: iear-1 reactor; fuel elements; post-irradiation examination; nondestructive testing; testing; gamma spectroscopy

  • IPEN-DOC 25320

    FEHER, A. ; ROSTELATO, M.E.C.M. ; ZEITUNI, C.A. ; MOURA, J.A. ; COSTA, O.L. ; SOUZA, C.D. . Análise da região soldada por processo laser em microtubos de titânio por meio de ensaio metalográfico e microdureza / Analysis of the region welded by laser process in titanium microtubes by metalographic and microhardness test. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23., 04-08 de novembro, 2018, Foz do Iguaçu, PR. Anais... 2018. p. 4196-4208.

    Abstract: Um dos materiais utilizados como invólucro de fontes radioativas seladas para aplicações na área da saúde é o titânio. Na construção de fontes radioativas seladas, o radioisótopo é confinado em uma cápsula de metal garantindo que não ocorra sua dispersão no meio externo. O processo de construção desse tipo de fonte requer muitas vezes a soldagem da cápsula, causando alterações das estruturas cristalinas do metal. Essas alterações podem resultar na fragilização da região de solda, ocasionando trincas e consequentemente a inutilização do conjunto. Este trabalho avaliou a possível existência de defeitos de soldagem por meio de ensaio metalográfico e de dureza. Foram realizados ensaios por microscopia óptica e MEV para avaliar a existência de trincas, poros, inclusões, falta de penetração e mordeduras. Foram realizados também ensaios de microdureza Vickers com a finalidade de verificar a variação da dureza entre o metal de base, zona termicamente afetada e zona fundida.

  • IPEN-DOC 27901

    ABREU, R.T. ; ANGELOCCI, L.V. ; NOGUEIRA, B.R. ; SANTOS, H.N. ; ZEITUNI, C.A. ; ROSTELATO, M.E.C.M. . Anisotropy function of a new 192-Ir brachytherapy source. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-15, 2021. DOI: 10.15392/bjrs.v9i1A.1506

    Abstract: Brachytherapy is a type of radiotherapy that uses radioactive sources (seeds, wires, among others) close to the tumor. Is important to provide a detailed description of seed dosimetry, so only the tumor will be irradiated avoiding unnecessary dose on adjacent organs and structures. To evaluate the dosimetric parameter of the anisotropy function for a new brachytherapy source, this work proposes the use of microcube TLD-100 dosimeters to find the dose rate using the AAPM Task Group 43 protocol (TG-43). The anisotropy function represents dose distribution around the source and has a major role for characterization of a new iridium source being implemented in Brazil. The value of D(r,θ) was measured using Solid Water phantoms, r value being the distance from the geometric center of the source to the position of the dosimeter on the phantom, and θ being the angle formed between the longitudinal axis of the source and the line connecting the geometric center to the TLD. Monte Carlo calculations were performed to evaluate the anisotropy function to validate the experimental measurements. For each distance value (r), an anisotropy function was plotted (1.0, 2.0, 3.0, 4.0, 5.0, and 10.0 cm). The results obtained with Monte Carlo calculations agreed ±2% with the experimental values for r greater than 3.0 cm, so these results show a good distribution of dose around the seed considering the high energy of 192-Ir (average of 380 KeV) and encapsulation thickness.

    Palavras-Chave: anisotropy; brachytherapy; dose rates; dosimetry; iridium 192; monte carlo method; phantoms; radiation dose distributions; radiation source implants; sealed sources; thermoluminescent dosemeters

  • IPEN-DOC 28462

    ANGELOCCI, L. ; NOGUEIRA, B.R. ; SOUZA, C.D. de ; ZEITUNI, C.A. ; ROSTELATO, M.E.C.M. . Assessing Ir-192 as an alternative to I-125 in ophthalmic treatment. Radiotherapy and Oncology, v. 152, Supplement 1, p. S735-S736, 2020. DOI: 10.1016/S0167-8140(21)01402-X

    Abstract: Purpose or Objective: Brachytherapy sources for ocular melanoma usually contain Co-60, I-125, Pd-103 or Ru/Rh-106 as radionuclides. Ir-192 is not a preconized radioactive material for this purpose, although it is used for other brachytherapy applications. Higher mean energy from Ir-192 emission (ca. 380 keV) may be a reason for the preference of I-125 (35 keV) or Pd-103 (21 keV) over it, since low penetration is desired on the small structures of the human eye. This is not, however, an excluding criterion, considering Co-60 and Ru/Rh-106 have even higher mean energies. The demand in Brazil for lower-cost seeds to treat ocular melanoma lead to the development of an Ir-192 seed to make treatment more accessible, but since it is not used as an ophthalmic brachytherapy source, before its dosimetry is considered, one should care about the possibility of using it over more stablished materials. Considering this, the aim of this work is to assess the possibility of using Ir-192 seeds as ophthalmic brachytherapy sources by comparing some dosimetric parameters of a new seed model with the most stablished I-125 seed in literature, OncoSeed 6711. Material and Methods: As an initial study on the topic, this work relies only on Monte-Carlo simulations using MCNP4C transport code. Parameters analyzed are air-kerma strength, dose-rate constant and depth-dose curve, attention given to points within the human eye dimensions. The medium considered was homogeneous water, as it is a good approximation to the eye tissues in terms of composition and density and allows for future comparisons with TG-43 based calculations. OncoSeed 6711 is not produced anymore, but its long term as the reference source for dosimetry was considered. A 20 mm COMS ophthalmic applicator was also modeled and considered to be fully loaded with each seed model to compare the same parameters at a realistically clinical approach. Results: As expected, due to the higher energy of the Ir-192 emission spectrum, dose fall-off on the transversal axis of the seeds is less pronounced for the new seed model. The steeper dose gradient for I-125 is also visible on the doserate constant value. The effect of using a COMS applicator only strengthens this characteristic. Depth-dose curves were calculated up to the distance of 5 cm, both for a single seed and for an applicator fully loaded with 24 seeds. All the eye components relevant for dosimetry are located within this range, like the cells of the crystallin and the optical nerve. Conclusion: If one expects to use Ir-192 as an alternative to I-125 in ophthalmic cancer treatment, at least the dosimetry following TG-43 protocol should be carried with utmost attention, as undesirable dose to healthy nearby tissues is unavoidable. Crafting a different applicator most suited for this radionuclide is a possibility that can be taken into account. Another recommendation is to go beyond TG-43 water-based protocol and actually estimate dose to relevant eye components.

  • IPEN-DOC 29454

    SILVA, J.T. ; NOGUEIRA, B.R. ; ANGELOCCI, L.V. ; SOUZA, C.D. ; TEODORO, L.E. ; SOUZA, P.D. ; RODRIGUES, B.T. ; CORREIA, R.W. ; SANTOS, H.N. dos ; ZEITUNI, C.A. ; ROSTELATO, M.E. . Avaliação do método produtivo de placas de epóxi com fósforo-32 para o tratamento do câncer espinhal e intracranial por braquiterapia. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 24., 6-10 de novembro, 2022, Águas de Lindóia, SP. Resumo... 2022.

    Abstract: A braquiterapia é uma modalidade de radioterapia utilizada no tratamento do câncer. Nessa modalidade, a fonte radioativa é posiciona junto ao tumor ou bem próxima a ele. A dose de radiação é entregue de forma contínua em um período curto de tempo (fontes temporárias) ou em períodos mais longos durante todo o decaimento radioativo do material (fontes permanentes). A maior vantagem da braquiterapia, é o fato da fonte estar bem próxima ao tumor o que significa que a região alvo recebe a maior parte da dose protegendo os tecidos sadios adjacentes à região tumoral. Shtrombakh et. al. trabalharam com césio-137 e verificaram que o uso do epóxi para a imobilização de fontes radiativas ocorreu sem vazamento por dois anos de testes. Pesquisas realizadas nos Estados Unidos por Folkert et. al. mostraram que placas flexíveis incorporadas com fósforo-32 são alternativas para o tratamento de câncer do sistema nervoso central na fase intraoperatória. No presente trabalho foi avaliada a uniformidade da placa de resina epóxi a partir de uma metodologia desenvolvida no Laboratório de fontes para Braquiterapia do IPEN/CNEN- SP. Vários testes foram realizados para determinar o melhor molde para a fabricação da placa. Concluiu-se que o politetrafluoretileno (PTFE), que comercialmente é conhecido como teflon foi o que obteve melhor resultado, devido a facilidade para desenformar a fonte após o processo de cura da resina. As placas de epóxi foram produzidas a resina 2220 e catalisador 3154 (Avipol), à proporção de 2:1 (massa). Para simular o material radioativo, ácido clorídrico (HCl) equivalente a 5 % da massa total (resina + catalisador) é acrescentado. O processo de cura da resina epóxi foi durante 24 h sob temperatura ambiente. As espessuras das placas foram medidas chegando-se a um valor médio de 0,300 mm ± 0,070. As medidas foram efetuadas com micrômetro medindo-se 10 pontos de cada placa. As medidas de largura e comprimento não foram realizadas, pois esses parâmetros não influenciam na uniformidade da dose. Para que a distribuição da atividade do fósforo-32 fosse estipulada, uma simulação por Método de Monte Carlo utilizando o código MCNP foi realizada. A variação máxima de dose ao longo da placa, considerando uma espessura totalmente uniforme de 0,300 mm, resultou em < 0,5 % até 0,5 cm antes da borda. O resultado da simulação mostra que com uma placa de espessura uniforme, a tendência da distribuição de dose seja homogênea. Pautando-se nos resultados, as placas de polímero epóxi se mostram viáveis para o uso em braquiterapia, sendo que o próximo passo do trabalho será os testes com material radioativo, a avaliação por métodos dosimétricos físicos e computacionais.

    Palavras-Chave: epoxides; brachytherapy; teflon; polytetrafluoroethylene; catalysis

  • IPEN-DOC 27911

    PINHEIRO, A.L.L.P.; COELHO, A.L.L.P.; SIMPSON, S.; SOARES, N.A.; SANTOS FILHO, W.P.; ZEITUNI, C.A. ; ROSTELATO, M.E.C.M. . Clinical-epidemiological profile of women with cervical cancer in the North of the State of Tocantins: 2000 to 2015 period. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-10, 2021. DOI: 10.15392/bjrs.v9i1A.1546

    Abstract: Cervical cancer (CC) is a worldwide public health problem and stands out in the North of the State of Tocantins as the leading cause of the cancer death. It is the fourth most common type cancer in women, with an estimate of 570 thousand new cases and 311 thousand deaths from this disease worldwide in 2018. The lack of effective screening increases the incidence of late diagnosis weighing on the budgets of developing countries, which are the most affected. The objective of this work is to describe the epidemiological profile of the woman treated which a diagnosis of cervical cancer in Northern of Tocantins. Materials and methods: It is a descriptive, retrospective, quantitative-interpretive study with analysis of data collected from 2000 to 2015 by the Health Information System of the Hospital Cancer Registry (SIS-RHC) linked to the Regional Hospital of Araguaína (HRA). The data were tabulated in spreadsheets for analysis of the variables evaluated. Results: 2.664 women with cervical cancer treated at the HRA were analyzed during this period. Within the existing stages, the stages 0, I and II were considered “early staging”, and stages III and IV were considered “late staging”. Conclusions: The factors occupation, race, education and smoking were well defined in the incidence of this tumor, especially in the case of late staging. The challenges are many to obtain adequate medical assistance, mainly in the Northern Region of Tocantins and adjacent regions. The knowledge of the epidemiological profile of these women will be important for the development of new health prevention policies, improving the incidence and mortality from this tumor.

    Palavras-Chave: epidemiology; neoplasms; uterus; carcinomas; statistical data; data analysis; women; patients

  • IPEN-DOC 18745

    PELEIAS JUNIOR, F.S.; ZEITUNI, C.A. ; ROSTELATO, M.E.C.M. ; SOUZA, C.D.; MATTOS, F.R.; BENEGA, M.A.G.. Comparação entre a utilização de sementes soltas e em cordas poliméricas em braquiterapia prostática no Brasil. In: CONGRESSO DA SOCIEDADE BRASILEIRA DE RADIOTERAPIA, 14., 20- de junho, 2012, Curitiba, PR. Anais... 2012.

    Palavras-Chave: prostate; neoplasms; brachytherapy; iodine 125; radiation source implants; comparative evaluations

  • IPEN-DOC 28194

    FERREIRA, H.J. ; ZEITUNI, C.A. ; SANTOS, H.N. ; ROSERO, W.A.A. ; ALCANTARA, G.F. ; ROSTELATO, MARIA E.C.M. . Comparative analysis between radioactive seed localization and wire-guided for non-palpable breast cancer surgery. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, November 29 - December 2, 2021, Online. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2021.

    Palavras-Chave: mammary glands; neoplasms; brachytherapy; surgery; comparative evaluations; internal irradiation; iodine 125; radiation source implants

  • IPEN-DOC 29127

    FERREIRA, H.J. ; ZEITUNI, C.A. ; RIGO, M.E.Z. ; SANTOS, H.N. ; ROSERO, W.A.A. ; ALCANTARA, G.F. ; ROSTELATO, M.E.C.M. . Comparative analysis between radioactive seed localization and wire-guided for non-palpable breast cancer surgery. Brazilian Journal of Radiation Sciences, v. 10, n. 3B, p. 1-13, 2022. DOI: 10.15392/2319-0612.2022.1909

    Abstract: The conservative surgery for impalpable breast cancer requires an intraoperative localization method that guides the identification and correct excision of the lesion. The aim of this study is to comparatively analyze two intraoperative breast localization technologies, wire guided localization (WGL) and radioactive seed localization (RSL), regarding their surgical efficacy through the outcomes of surgical margins, intraoperative re-excision, reoperation and recurrence. To this end, a systematic search was realized in databases for clinical trials that match with the study eligibility criteria. The selected studies were evaluated for their methodological quality; the data were then collected and quantitatively synthesized. The results comprised thirty-eight studies that match the eligibility criteria. The main outcomes reported demonstrating that the RSL is at least equivalent to the WGL in efficiency rates. These results confirm the method applicability for impalpable breast lesions surgery in an effective way, in addition to presenting organizational optimization of radiology and surgery services by allowing the surgery to be performed up to two months after seed implantation.

    Palavras-Chave: nuclear medicine; irradiation; mammary glands; surgery; brachytherapy; neoplasms; iodine 125

  • IPEN-DOC 22299

    MOURA, E.; SOUZA, C. de; PELEIAS JUNIOR, F.S.; ZEITUNI, C.A. ; ROSTELATO, M.E.C.M. ; MATOS, F.R.; BENEGA, M.A.G.; MOURA, J.A. ; FEHER, A. ; COSTA, A.L.. Comparison between the use loose and polymer string seeds in prostatic brachytherapy in Brazil. In: EUROPEAN SOCIETY FOR RADIOTHERAPY AND ONCOLOGY, April 4-8, 2014, Vienna, Austria. Abstract... 2014.

    Palavras-Chave: patients; radiotherapy; comparative evaluations; polymers; brachytherapy; iodine 125; damage; prostate

  • IPEN-DOC 22298

    MOURA, E.; SOUZA, C. de; PELEIAS JUNIOR, F.S.; ZEITUNI, C.A. ; ROSTELATO, M.E.C.M. ; MATTOS, F.R.; BENEGA, M.A.G.; MOURA, J.A. ; FEHER, A. ; COSTA, A.L.. Comparison between the use loose and polymer string seeds in prostatic brachytherapy in Brazil. Radiotherapy and Oncology, v. 111, Suppl. 1, p. S98, 2014.

    Palavras-Chave: patients; radiotherapy; comparative evaluations; polymers; brachytherapy; iodine 125; damage; prostate

  • IPEN-DOC 18746

    MATTOS, F.R.; ROSTELATO, M.E.C.M. ; ZEITUNI, C.A. ; SOUZA, C.D.; PELEIAS JUNIOR, F.S.; BENEGA, M.A.G.. Desenvolvimento de um dispositivo de suporte de sementes de braquiterapia para irradiação. In: CONGRESSO DA SOCIEDADE BRASILEIRA DE RADIOTERAPIA, 14., 20- de junho, 2012, Curitiba, PR. Anais... 2012.

    Palavras-Chave: ophthalmology; eyes; neoplasms; brachytherapy; internal irradiation; iridium 192; brazilian cnen; iear-1 reactor

  • IPEN-DOC 08567

    TORRES, W.M. ; UMBEHAUN, P.E. ; BAPTISTA FILHO, B.D. ; SILVA, J.E.R. ; ZEITUNI, C.A. ; TEIXEIRA e SILVA, A. . Desenvolvimento e utilizacao de elementos instrumentados e sistemas de inspecao visual para reatores nucleares de pesquisa. In: CONGRESSO NACIONAL DE ENGENHARIA MECANICA, 2., 12-16 ago, 2002, Joao Pessoa, PB. Anais... 2002.

    Palavras-Chave: iear-1 reactor; fluid flow; reactor cores; fuel elements; safety analysis; reactor safety

  • IPEN-DOC 06591

    TERREMOTO, L.A.A. ; ZEITUNI, C.A. ; PERROTTA, J.A. . Determinacao do grau de queima em elementos combustiveis tipo placa por meio de espectrometria gama. In: 7o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 31 de agosto - 3 de setembro, 1999, Belo Horizonte, MG. 1999.

    Palavras-Chave: burnup; spent fuel elements; fuel plates; gamma spectroscopy; nondestructive analysis; neutron flux; comparative evaluations

  • IPEN-DOC 22364

    PELLEIAS JUNIOR, F.S.; ZEITUNI, C.A. ; SOUZA, C.D. ; ROSTELATO, M.E.C.M. ; MATTOS, F.R.; BENEGA, M.A.G.; RODRIGUES, B.T.; TIEZZI, R.; OLIVEIRA, T.B.; FEHER, A. ; MOURA, J.A. ; COSTA, O.L. . Development and characterization of iridium-192 seeds for brachytherapy treatment of ocular tumors. In: EUROPEAN NUCLEAR CONFERENCE 2014, May 11-14, 2014, Marseille, France. Proceedings... 2014. p. 36-43.

    Palavras-Chave: iridium 192; brachytherapy; ophthalmology; neoplasms; platinum alloys; iridium alloys; x-ray spectroscopy; iear-1 reactor; radiopharmaceuticals

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.