Navegação por assunto "attenuation"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 08357

    SILVA, DANIELA de F.T. da . Analise da birrefringencia do colageno e do coeficiente de atenuacao de amostras de pele sadia e queimada irradiadas pelo laser de He-Ne linearmente polarizado. 2002. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, São Paulo. 78 p. Orientador: Martha Simoes Ribeiro.

    Palavras-Chave: collagen; birefringence; skin; wounds; healing; laser radiation; therapeutic uses; attenuation; polarization; burns; photoreactivation

  • IPEN-DOC 20914

    MORAES, MARCIA ; ARANHA, ANA ; ZEZELL, DENISE ; FREITAS, ANDERSON . Assessment of the optical attenuation coefficient of erored dentin. Lasers in Surgery and Medicine, v. 47, Suppl. 26, p. 32-33, 2015.

    Palavras-Chave: coherent radiation; attenuation; dentin; neodymium lasers; fluorine; diagnostic uses; tomography; optical models

  • IPEN-DOC 22391

    MORAES, MARCIA; ARANHA, ANA ; ZEZELL, DENISE ; FREITAS, ANDERSON . Assessment to the optical attenuation coefficient of erored dentin. Lasers in Surgery and Medicine, v. 47, Sippl. 26, p. 32-33, 2015.

    Palavras-Chave: attenuation; dentin; in vitro; evaluation; tomography; irradiation; neodymium lasers; fluorides; yttrium compounds

  • IPEN-DOC 23121

    VENEZIANI, G.R. ; CORREA, E.L. ; POTIENS, M.P.A. ; CAMPOS, L.L. . Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams. Journal of Physics: Conference Series, v. 733, p. 1-6, 2016. DOI: 10.1088/1742-6596/733/1/012088

    Abstract: IAEA code of practice TRS-457 states that standard phantoms should offer the same primary attenuation and scatter production as relevant body section of a representative patient. Material cost, availability and dimensional stability must also be considered. The goal of this study is to determine the attenuation coefficient of printed ABS and PLA samples in standard X-ray beams, verifying if phantoms printed with these materials could be an easier-handle substitute for PMMA, enabling the creation of different designs in an easier and cheaper way. Results show that PMMA presents higher attenuation coefficient, followed by PLA and ABS, which means that thinner PMMA layer creates higher radiation attenuation.

    Palavras-Chave: attenuation; availability; design; layers; patients; phantoms; pmma; radiology; stability; standards; x radiation

  • IPEN-DOC 21719

    VENEZIANI, G.R. ; CORREA, E.L.; POTIENS, M.P.A. ; CAMPOS, L.L. . Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standards beams. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 2 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: attenuation; lasers; quality assurance; phantoms; samplers; radiology; diagnostic uses

  • IPEN-DOC 03174

    ROGERO, J.R. . Attenuation of toxins by gamma radiation. In: 6th JAPAN-BRAZIL SYMPOSIUM ON SCIENCE AND TECHNOLOGY, Aug. 10-13, 1988, Sao Paulo, SP. 1988.

    Palavras-Chave: toxins; gamma radiation; attenuation

  • IPEN-DOC 28658

    OLIVEIRA, M.V.L.; SAVI, M. ; ANDRADE, M.A.B.; VILLANI, D. ; POTIENS, M.P.A. ; BRANCO, H.S.; UBEDA, C.; MDLETSHE, S.. Attenuation properties of common 3D printed FFF plastics for mammographic applications. Brazilian Journal of Radiation Sciences, v. 10, n. 1, p. 1-17, 2022. DOI: 10.15392/bjrs.v10i1.1732

    Abstract: The aim of this study was to evaluate the feasibility of using acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) 3D printing filaments as materials for mammography phantom construction, comparing their attenuation properties at two different set-ups: at a Calibration Laboratory and directly to a mammography unit. The attenuation of 3D printed test phantoms of two types of common 3D printing Fused Filament Fabrication (FFF) filaments (ABS and PLA) were characterized in comparison with polymethylmethacrylate (PMMA). The measurements were carried out with standard IEC 61267 X-rays, using RQR 2-M and RQR 4-M beam qualities at the Instruments Calibration Laboratory, and then applied to a mammography unit, with measurements with 28 kV and 35 kV. Attenuation characteristics evaluated indicate the suitable equivalence of PLA to PMMA for 3D printing breast complex phantoms. The plastic materials used in this study suggest that the FFF technique may be suitable for mammography phantom development.

    Palavras-Chave: 3d printing; acrylonitrile; animal tissues; attenuation; butadiene; filaments; mammary glands; phantoms; pmma; styrene; x radiation

  • IPEN-DOC 10911

    SALVADOR, F.C.; RIO, P.B.; NERSISSIAN, D.Y.; COSTA, P.R.; CALDAS, L.V.E. . Avaliacao de folhas de chumbo utilizadas para determinacao da equivalencia em atenuacao de dispositivos usados em radioprotecao. In: IBERIAN LATIN AMERICAN CONGRESS OF MEDICAL PHYSICS, 3.; BRAZILIAN CONGRESS OF MEDICAL PHYSICS, 9, Sept. 26-29, 2004, Rio de Janeiro, RJ. Anais... 2004.

    Palavras-Chave: lead; radiation protection; attenuation; calibration standards; comparative evaluations

  • IPEN-DOC 03828

    COSTA, P.R.; CALDAS, L.V.E. . Avaliacao de materiais atenuadores. Modelo para a distribuicao da radiacao espalhada. In: 3o. FORUM NACIONAL DE CIENCIA E TECNOLOGIA EM SAUDE, 13-17 de outubro, 1996, Campos do Jordao, SP. 1996. p. 469-470.

    Palavras-Chave: mathematical models; distribution; photons; scattering; attenuation; radiology; lucite

  • IPEN-DOC 11519

    SOARES, FERNANDA C.S. . Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2006.tde-16052012-103302

    Abstract: Neste trabalho foram avaliados aventais de proteção e blindagens de ovário de cinco fabricantes segundo as normas NBR / IEC 61331-1 e NBR / IEC 61331-3 de 2004. Para a determinação da espessura equivalente de atenuação foram aplicadas três metodologias diferentes (interpolação linear, modelo de Archer e somatório de exponenciais), uma vez que a norma não indica como este valor deve ser obtido. Além disso, foram estimadas as incertezas associadas a cada método e a influência do número de medições na incerteza combinada. As características de confecção avaliadas foram: documento acompanhante, projeto, materiais, dimensões e marcação da etiqueta. Para esta avaliação foi elaborado um formulário que contemplava todas as exigências da NBR / IEC 61331-3. Os resultados mostraram uma grande diferença entre os valores de espessura equivalente de atenuação declarados e medidos. A comparação dos resultados das três metodologias aplicadas mostrou que há pouca variação entre os valores obtidos e entre as incertezas associadas nas diferentes metodologias. Foi possível observar também que o número de medições não contribui significativamente para o aumento da incerteza nas três metodologias. A metodologia que melhor se adequou à rotina do laboratório foi a metodologia da interpolação linear com cinco medições da taxa de kerma no ar. A discrepância entre os resultados apresentados neste trabalho e as exigências das normas estudadas mostra a necessidade de tornar compulsória a certificação dos dispositivos de proteção, contribuindo assim para o aumento da proteção radiológica do usuário.

    Palavras-Chave: attenuation; data covariances; experimental data; ionization chambers; kerma; protective clothing; radiation protection; radiation quality; safety standards; thickness; x-ray equipment

  • IPEN-DOC 02521

    KASSAR, E. ; SILVA, R.D.. Calibracao de uma sonda resistiva de radio-frequencia, na medida de fracao de vazio e comparacao dos resultados com tecnica de absorcao gama. In: 6th ENCONTRO NACIONAL DE FISICA DE REATORES, Dec. 3-5, 1986, Sao Jose dos Campos, SP, Brazil. 1986.

    Palavras-Chave: attenuation; calibration; comparative evaluations; electronic circuits; gamma radiation; measuring methods; rf systems; void fraction

  • IPEN-DOC 26744

    VILLANI, D. ; SAVI, M. ; ANDRADE, M.A.B.; CAMPOS, L.L. ; POTIENS, M.P.A. . Characterization of ABS + W and ABS + Bi 3D printing filaments attenuation for different photon beams. In: CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA ELÉTRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MECÂNICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QUÍMICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ÓPTICA, 3., 24-27 de novembro, 2019, Florianópolis, SC. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2019.

    Abstract: 3D printing techniques and materials have become widely available in the last couple of decades and remains a hot topic of study as new materials can lead to new applications. This study aims to evaluate the attenuation behaviour of GMASS over photon beams ranging from 29.7 up to 661.7keV, comparing with pure ABS and using theoretical data of pure lead as reference. It was used the transmission method to obtain experimental attenuation coefficients to all materials and theoretical data. HVL and TVL calculations were also performed. Results show that ABS+W has higher attenuation than ABS+Bi and pure ABS. Using the lead theoretical reference data it can be concluded that although ABS+Bi and ABS+W attenuates less than pure lead, the 3D printing filaments can be used to create shielding tolls depending on radiation energy and application.

    Palavras-Chave: attenuation; cesium 137; dosimetry; energy dependence; filaments; photon beams; polymers; radiations; shielding

  • IPEN-DOC 27802

    VILLANI, D. ; SAVI, M. ; ANDRADE, M.A.B.; CAMPOS, L.L. ; POTIENS, M.P.A. . Characterization of ABS + W and ABS + Bi 3D printing filaments attenuation for different photon beams. Journal of Physics: Conference Series, v. 1826, p. 1-8, 2021. DOI: 10.1088/1742-6596/1826/1/012037

    Abstract: 3D printing techniques and materials have become widely available in the last couple of decades and remains a hot topic of study as new materials can lead to new applications. This study aims to evaluate the attenuation behaviour of GMASS over photon beams ranging from 29.7 up to 661.7keV, comparing with pure ABS and using theoretical data of pure lead as reference. It was used the transmission method to obtain experimental attenuation coefficients to all materials and theoretical data. HVL and TVL calculations were also performed. Results show that ABS+W has higher attenuation than ABS+Bi and pure ABS. Using the lead theoretical reference data it can be concluded that although ABS+Bi and ABS+W attenuates less than pure lead, the 3D printing filaments can be used to create shielding tolls depending on radiation energy and application.

    Palavras-Chave: attenuation; cesium 137; dosimetry; energy dependence; filaments; photon beams; polymers; radiations; shielding

  • IPEN-DOC 12405

    SOARES, F.C.S.; NERSISSIAN, D.Y.; COSTA, P.R.; CALDAS, L.V.E. . Comparacao entre tres metodologias utilizadas para a determinacao da espessura equivalente de atenuacao em chumbo. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 12., 6-9 de jun., 2007, Foz do Iguacu, PR. Resumo... 2007.

    Palavras-Chave: lead; attenuation; uncertainty principle; radiation protection

  • IPEN-DOC 19478

    SANTIN, STEFANY P.; SANTOS, LUIZ A.U.; FREITAS, ANDERSON Z. de ; MARTINHO JUNIOR, ANTONIO C.; DIAS, DJALMA B. ; SOARES, FERNANDO A.N.; SEGURA PINO, EDDY ; VELOSO, MARCELO N.; MATHOR, MONICA B. . Comparison between optical coherence tomography technique and mechanical compression assay to evaluate ionizing radiation effects in frozen and lyophilized bone tissue. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: attenuation; bone tissues; coherent radiation; freezing; ionizing radiations; lyophilization; mechanical tests; photons; radiation doses; radiation effects; sterilization; tomography

  • IPEN-DOC 27245

    FONTES, ERIC H. ; NANDENHA, JULIO ; PIASENTIN, RICARDO M. ; SOUZA, RODRIGO F.B. de ; NETO, ALMIR O. . Comparison of various atomic compositions of Au@Pd/C, Pd/C, and AuPd/C electrocatalysts for direct ethanol fuel cells. Energy Storage, v. 2, n. 3, p. 1-15, 2020. DOI: 10.1002/est2.139

    Abstract: Pd/C, Au@Pd/C (core-shell), and AuPd/C (AR—consisting in Au microparticles) were used as electrocatalysts for ethanol oxidation in alkaline medium. A synergistic effect between Au and Pd atoms in Au@Pd/C makes the binding between ethanol and Au@Pd/C stronger. This leads to product formation in higher potentials and can be useful to select ethanol products. We also showed that the atomic composition of the electrocatalysts to be used in fuel cells and in powder form to be used in electrochemical experiments are very similar, reaching high values of correlation. The depth profiling X-ray photoelectron spectroscopy for the anode catalysts to be used in fuel cells can provide new insights about ethanol oxidation in direct ethanol fuel cells (DEFCs), for instance, metal oxide species can act in fuel cells environment. In terms of electric generation, Au@Pd/C presented a better performance in electrochemical experiments; the current density was about 1.6 times higher than the peak current density obtained for Pd/C. In terms of electrochemical stability, Au@Pd/C presented better final current density when compared to Pd/C and AuPd/C electrocatalysts. However, in DEFC experiments, Pd/C showed better performance.

    Palavras-Chave: electrocatalysts; gold alloys; palladium alloys; direct ethanol fuel cells; x-ray photoelectron spectroscopy; depth; fourier transform spectrometers; attenuation; reflection; in-situ processing

  • IPEN-DOC 04923

    VENTURINI, L. ; NISTI, M.B. . Correcao de auto-absorcao na espectrometria gama de amostras ambientais. In: 4th MEETING ON NUCLEAR APPLICATIONS, ENCONTRO NACIONAL DE APLICACOES NUCLEARES, August 18-22, 1997, Pocos de Caldas, MG. 1997. p. 137-142.

    Palavras-Chave: environmental materials; gamma spectroscopy; attenuation; dosimetry; radiation monitoring

  • IPEN-DOC 15396

    FRIMAIO, A.; COSTA, P.R.; VANDERLINDE, F.V.F.; CAMPOS, L.L. . Desenvolvimento de materiais ceramicos para utilizacao em protecao radiologica diagnostica. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 11., 14-17 de junho, 2006, Ribeirao Preto, SP. Resumo... 2006.

    Palavras-Chave: attenuation; barite; barium sulfates; barium; ceramics; computerized simulation; density; experimental data; kerma; lead; optimization; qualitative chemical analysis; quantitative chemical analysis; radiation protection; shielding materials; shielding; thickness; x radiation

  • IPEN-DOC 11345

    FRIMAIO, AUDREW . Desenvolvimento de um material cerâmico para utilização em proteção radiológica diagnóstica. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Leticia Lucente Campos Rodrigues. DOI: 10.11606/D.85.2006.tde-04062007-163758

    Abstract: Este estudo tem por objetivo formular um composto cerâmico para revestimento de paredes visando contribuir para a otimização da blindagem de salas de diagnóstico. O trabalho foi baseado em medidas experimentais de atenuação da radiação X (80 e 100 kV) empregando materiais cerâmicos de revestimento contendo diferentes suportes cerâmicos (vermelho, branco, grês, porcelanatos, etc). Dentre os suportes cerâmicos avaliados, o grês branco apresentou melhores propriedades atenuadoras, e foi considerado o mais adequado para a proposta deste trabalho. Diferentes formulações de grês branco foram estudadas e alteradas a fim de obter melhores propriedades atenuadoras. Foram efetuadas simulações de composições cerâmicas de revestimento grês dentro das porcentagens de matérias-primas necessárias na composição que são 12-20% argila; 6-18% caulim; 12-25% filito; 8-14% quartzo; 10-18% feldspato; 32- 40% pegmatito; 6-8% talco. As composições químicas quantitativas e qualitativas destes materiais foram também avaliadas, e os elementos constituintes mais comuns são SiO2, Fe2O3, Al2O3, CaO e Ti2O3. Considerando que o CaO pode ser substituído pelo PbO ou BaO, foram estudadas formulações com maiores teores de óxidos de Pb e Ba. O comportamento destes materiais como atenuadores para a radiação X foi investigado por meio de simulações computacionais que levaram em consideração os espectros de raios X incidentes e transmitidos através das diferentes composições estudadas e comparado com os materiais de referência Pb, Ba e BaSO4 (barita). Os resultados obtidos nas simulações indicaram as formulações do composto de suporte cerâmico grês que demonstram melhores propriedades de atenuação levando-se em conta as energias usadas em raios X diagnóstico (80, 100 e 150 kV). Placas cerâmicas baseadas na composição formulada que apresentou menor diferença percentual em relação ao Pb foram produzidas em laboratório e testadas fisicamente como revestimento de parede e barreira protetora. Propriedades como módulo de resistência à flexão, densidade, carga de ruptura, absorção de água e atenuação da radiação X foram avaliadas para todas as placas produzidas.

    Palavras-Chave: attenuation; barite; barium sulfates; barium; ceramics; computerized simulation; density; experimental data; kerma; lead; optimization; qualitative chemical analysis; quantitative chemical analysis; radiation protection; shielding materials; shielding; thickness; x radiation

  • IPEN-DOC 22684

    SILVA, NATALIA F. ; CINTRA, FELIPE B. ; CASTRO, MAYSA C. de ; CALDAS, LINDA V.E. . Determinação do fator de correção para atenuação no ar para uma câmara de ionização de ar livre / Determination of the air attenuation correction factor for a free air ionization chamber. In: CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇOES IONIZANTES, 3., 21-23 de novembro, 2016, Rio de Janeiro, RJ. Anais... 2016. p. 1-7.

    Abstract: Este trabalho tem como objetivo apresentar os resultados obtidos experimentalmente e por simulação para o fator de correção da atenuação no ar de uma câmara de ionização de ar livre de cilindros concêntricos Victoreen, modelo 481- 5. Este fator de correção foi obtido para as qualidades padronizadas de mamografia, estabelecidas no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Os valores obtidos foram comparados com os resultados do laboratório padrão primário alemão Physikalisch-Technische Bundesanstalt (PTB), obtendo-se diferenças máximas de 0,40% para o valor experimental e de 0,31% para o valor simulado.

    Palavras-Chave: attenuation; beams; comparative evaluations; energy dependence; ionization chambers; radiative corrections; x radiation

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.