Navegação por assunto "positron computed tomography"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 21714

    SARMENTO, D.M. ; RODRIGUES, D.L. ; SANCHES, M.P. ; CARNEIRO, J.C.G.G. . Ambient radiation levels in a microPET/CT research laboratory. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 2 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: thermoluminescent dosimetry; animals; radiation protection; evaluation; radiation monitoring; laboratories; computerized tomography; occupational exposure; positron computed tomography

  • IPEN-DOC 14098

    MASSICANO, FELIPE; MASSICANO, ADRIANA V.F.; SILVA, NATANAEL G. ; CINTRA, FELIPE B.; CARVALHO, RODRIGO M.; YORIYAZ, HELIO . Analysis of ct and pet/spect images for dosimetry calculation. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: animal tissues; density; dosimetry; gamma cameras; i codes; images; m codes; monte carlo method; numerical data; positron computed tomography; single photon emission computed tomography

  • IPEN-DOC 24629

    BELINATO, WALMIR; SANTOS, WILLIAM S.; PERINI, ANA P.; NEVES, LUCIO P.; CALDAS, LINDA V.E. ; SOUZA, DIVANIZA N.. Avaliação de doses equivalentes em PET/CT com 18F utilizando o Método Monte Carlo com código MCNPX. In: ANAIS DA SOCIEDADE BRASILEIRA DE BIOCIENCIAS NUCLEARES, 09-11 de outubro, 2017, São Paulo, SP. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Biociências Nucleares, 2017. p. 60-73.

    Abstract: A técnica diagnóstica PET/CT (Positron Emisson Tomography/Computer Tomography) une recursos diagnósticos da Medicina Nuclear e da Radiologia. A técnica PET produz imagens metabólicas por meio de radiofármacos emissores de pósitrons. O presente trabalho usou o método Monte Carlo (MMC), especificamente o código de Monte Carlo NParticle – MCNPX, para simular a interação da radiação envolvendo fótons e partículas, tais como pósitrons e elétrons, com simuladores antropomórficos adultos virtuais em exames de PET/CT e determinar doses absorvidas e equivalentes em exames de pacientes adultos masculino e feminino. Para os cálculos, considerou-se os parâmetros dos feixes de tomografia computadorizada (colimação e filtração) de dois equipamentos distintos e as atividades de 18F-FDG comumente empregadas em exames de rotina. Foram estimados novos valores para fatores de conversão de dose absorvida por atividade administrada (valores-S) para doses internas em órgãos de pacientes com características similares aos simuladores de voxels escolhidos. Comparando-se com as doses absorvidas em órgãos devido ao 18F (doses internas), as doses absorvidas médias externas - devido ao feixe de raios X de CT - equivalem a 14,2% (equipamento GE) e 26,3% (equipamento Siemens). Essa diferença entre equipamentos pode ser relacionada principalmente com a quantidade de cortes de CT necessários para o exame de corpo inteiro (40 mm/rotação para ao GE e 20 mm/rotação para o Siemens), com uso do filtro gravata borboleta (filtro bowtie). Considerando-se as doses absorvidas internas, os novos coeficientes por atividade administrada calculados apresentaram um acréscimo próximo de 30% em relação aos valores da ICRP 106 e podem ser associados com representação morfológica mais realista dos órgãos dos simuladores utilizados e à introdução de fatores de espalhamento para fótons, porque os simuladores foram dispostos sobre uma mesa de exames, o que não é levado em consideração na ICRP 106.

    Palavras-Chave: absorbed radiation doses; dosimetry; equivalent radiation doses; fluorine 18; fluorodeoxyglucose; icrp; monte carlo method; phantoms; positron computed tomography; simulators

  • IPEN-DOC 27352

    FERREIRA, ARYEL H. . Avaliação de nanopartículas proteicas radiomarcadas dirigidas a tecidos tumorais como agentes diagnósticos / Evaluation of radiolabeled protein-based nanoparticles to target tumor tissue as a potential diagnosis agent . 2020. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo, SP. 6 p. Orientador: Ademar Benévolo Lugão. DOI: 10.11606/T.85.2020.tde-24092020-145109

    Observação: Há arquivos retidos devido a solicitação (publicação de dados, patentes ou diretos autorais). Data de Liberação: 09/03/2024.

    Abstract: Recentes avanços em nanomedicina e nanotecnologia têm expandido o desenvolvimento de nanoestruturas multifuncionais que combinem especificidade e funções terapêuticas e de diagnóstico em complexos nanoestruturados, a fim de superar barreiras biológicas que podem dificultar a administração e a captação seletiva e eficaz de medicamentos e agentes diagnósticos em tecidos tumorais. Nanopartículas vêm sendo utilizadas em Medicina Nuclear como carreadores de radionuclídeos emissores de radiação gama (γ) ou pósitron (+1β) para imagens diagnósticas por PET, SPECT e emissores de partículas α e -1β utilizados em endorradioterapia para destruir especificamente o tecido tumoral. O objetivo deste trabalho concentrou-se no estudo da marcação com Tecnécio-99m de nanopartículas de papaína e albumina, sintetizadas por reticulação induzida por radiação, e na caracterização de seus comportamentos in vitro e in vivo, de modo a desenvolver novos nanorradiofármacos e avaliar seu potencial para realização de diagnóstico de tumores mamários utilizando a técnica de medicina nuclear SPECT. Técnicas de microscopia eletrônica e espalhamento de luz evidenciaram formação de nanopartículas esféricas com dispersão de tamanho de 9,3 ± 1,9 nm para as nanopartículas de papaína e 25,1 ± 2,9 nm para as nanopartículas de albumina. Um elevado rendimento radioquímico (>90%) e estabilidade frente aos agentes transquelantes presentes no soro foram observados para ambas as nanopartículas até pelo menos 6h. A biodistribuição em animais saudáveis demonstrou diferentes perfis de excreção, sendo a 99mTc-P-NPs excretada principalmente pelo rim, enquanto a 99mTc-BSA-NPs é excretada principalmente por via hepática. Nos estudos in vitro, as nanopartículas mostraram-se promissoras com 74% e 57,6% da captação total em células MDA-MB231, respectivamente para 99mTc-P-NPs e 99mTc-BSA-NPs. Nos estudos in vivo verificou-se acentuada captação tumoral com boa visualização em imagens adquiridas em micro-SPECT/CT. Deste modo, as nanopartículas proteicas utilizadas no corrente trabalho mostraram-se promissoras para serem utilizadas como sistema de veiculação de radionuclídeos diagnósticos para estudos de sua distribuição sistêmica, bem como de sua aplicação como traçador SPECT em tumores mamários.

    Palavras-Chave: neoplasms; tumor cells; blood cells; gamma radiation; technetium 99 target; product labeling; microstructure; nanotechnology; proteins; carriers; albumins; blood serum; enzymes; papain; excretion; physiology; biological effects; in vivo; in vitro; positron computed tomography; single photon emission computed tomography; biological localization; diagnosis; radiotherapy

  • IPEN-DOC 21822

    SARMENTO, DANIELE M. . Avaliação dos níveis de radiação ambiental no laboratório de tomografia por emissão de pósitrons acoplada a tomografia computadorizada, microPET/CT / Evaluation of ambient radiation levels in positron emission tomography/computed tomography in microPET/CT laboratory . 2016. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 83 p. Orientador: Janete Cristina Gonçalves Gaburo Carneiro. DOI: 10.11606/D.85.2016.tde-01072016-132544

    Abstract: O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.

    Palavras-Chave: radiation protection; positron computed tomography; laboratories; ilo; safety standards; dose-response relationships; environmental exposure; acute irradiation; biological effects; personnel; employment

  • IPEN-DOC 29044

    PIJEIRA, MARTHA S.O. ; SANTOS, SOFIA N. dos ; ARAUJO, YASNIEL B. ; LAPOLLI, ANDRE L. ; WANDERMUREN, MARCIO N.; RIERA, ZALUA R.; CARVALHO, IVONE; ELSINGA, PHILIP H.; BERNARDES, EMERSON S. . A closer look at the synthesis of 2‑[18F] fluoroethyl tosylate to minimize the formation of volatile side‑products. EJNMMI Radiopharmacy and Chemistry, v. 7, n. 1, p. 1-15, 2022. DOI: 10.1186/s41181-022-00179-8

    Abstract: Background: 2-[18F]Fluoroethyltosylate ([18F]FEtOTs) is a well-known 18F-fluoroalkylating agent widely used to synthesize radiotracers for positron emission tomography. The widespread use of [18F]FEtOTs is due in part to its low volatility when compared to other halide and sulfonate building blocks. In this work, the radioactive volatile side-products formed during the synthesis of [18F]FEtOTs were identified and characterized for the first time, and an optimization of the reaction conditions to minimize their formation was proposed. Results: In order to characterize the volatiles produced during [18F]FEtOTs synthesis, the reaction mixtures of both cold FEtOTs and [18F]FEtOTs were co-injected onto the HPLC system. The radioactive peaks corresponding to the volatile compounds were collected, analyzed through headspace gas chromatography mass spectrometry sampler (HS-GC–MS) and identified as vinyl fluoride ([19F]VF) and 2-fluoroethanol ([19F]FEOH). By using a rotatable central composite design with a two-level full factorial core of two factors (22), it was determined that temperature and time are independent variables which affect the generation of [18F]VF and [18F]FEOH during the radiosynthesis of [18F]FEtOTs. In addition, in order to reduce the formation of the volatiles ([18F]VF and [18F]FEOH) and increase the yield of [18F]FEtOTs, it was demonstrated that the molar ratio of base to precursor must also be considered. Conclusion: [18F]VF and [18F]FEOH are volatile side-products formed during the radiosynthesis of [18F]FEtOTs, whose yields depend on the reaction time, temperature, and the molar ratio of base to precursor. Therefore, special care should be taken during the radiosynthesis and subsequent reactions using [18F]FEOTs in order to avoid environmental contamination and to improve the yield of the desired products.

    Palavras-Chave: fluorides; fluorine 18; gases; radioactive materials; radiation protection; positron computed tomography

  • IPEN-DOC 28011

    VILLANI, DANIEL . Desenvolvimento de um simulador antropomórfico de pescoço-tireoide tecido-equivalente impresso em 3D para aplicações multidisciplinares / Development of a 3D printed tissue-equivalent anthropomorphic neck-thyroid phantom for multidisciplinary applications . 2021. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 103 p. Orientador: Letícia Lucente Campos Rodrigues. DOI: 10.11606/T.85.2021.tde-16062021-143936

    Abstract: Objetos simuladores (no inglês, phantoms), dispositivos que representam o corpo humano, têm sido usados nas áreas da física médica, física e engenharia biomédica desde o início. Logo após a descoberta dos raios-X, as notícias dos benefícios médicos da radiação se espalharam rapidamente. A geometria e a composição de um simulador são determinadas pela prática a qual será aplicado. Existem desde os mais simples, baseados em água para medir a saída de feixes de terapia de megavoltagem, aos de maior complexidade, antropomórficos para controle de qualidade em radioterapia. O uso de impressão 3D e filamentos comumente encontrados comercialmente para o desenvolvimento de simuladores está sendo investigado. A aplicação desta técnica para o desenvolvimento de simuladores de baixo custo requer um estudo complexo da interação dos materiais impressos com diferentes tipos e qualidades de radiação, bem como a caracterização de configurações de impressão. Realizando essas medições, é possível encontrar metodologias para que possam simular corretamente o tecido humano. O objetivo desse trabalho constitui no projeto e na construção de um objeto simulador antropomórfico de tireoide (pescoço), utilizando uma impressora 3D e materiais tecido-equivalentes, para ser utilizado em aplicações multidisciplinares. Estudos de equivalência a tecidos humanos para filamentos de PLA, ABS e ABS XCT desenvolvidos no IPEN foram realizados em feixes de fótons padrão. Utilizou-se como base anatômica e de modelagem 3D o simulador comercial ATOM MAX 711, da CIRS. Os dados experimentais mostram a possibilidade de alcançar condições de equilíbrio eletrônico com as mesmas especificações de espessura para PLA e ABS, possibilitando a substituição do PMMA em diversas aplicações dosimétricas. Os filamentos de ABS aditivados com BaSO4 desenvolvidos no IPEN possuem propriedades de atenuação aumentadas significativamente em relação ao ABS puro, PLA e PMMA e são equivalentes aos tecidos ósseos nos feixes estudados. Diferentes tecidos ósseos podem ser simulados com uso de diferentes percentuais de infill. A metodologia de modelagem do simulador 3D deste estudo abre possibilidades de uso de imagens tomográficas de quaisquer objetos, ou até mesmo pacientes, para realização de prototipagem 3D de simuladores cada vez mais específicos e customizados. O simulador desenvolvido apresenta todas as características desejáveis para aplicações em proteção radiológica, dosimetria utilizando detectores TL/OSL, medições de radioisótopos incorporados na tireoide (tanto contadores de contaminação, quanto detectores de medicina nuclear) e treinamento de técnicas de aquisição de imagens por raios-X. Constitui uma alternativa viável de simulador equivalente a tecido; e de baixo custo, se comparado com os simuladores importados.

    Palavras-Chave: endocrine glands; thyroid cells; neck; tissue-equivalent materials; phantoms; pmma; computer-aided manufacturing; filaments; polyacrylates; biomedical radiography; nuclear engineering; x radiation; positron computed tomography; photon emission; radiothermoluminescence; uses; efficiency; performance; differential calculus; three-dimensional calculations

  • IPEN-DOC 18256

    CARVALHO, LARISSA G. de . Desenvolvimento do radiofármaco sup(18)F-acetato para detecção de tumores primários através do PET/CT / Development of the radiopharmaceutical sup(18)F-acetate for detection of primary tumors through PET/CT . 2012. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 100 p. Orientador: João Alberto Osso Junior. DOI: 10.11606/D.85.2012.tde-10122012-101221

    Abstract: A tomografia por emissão de pósitrons associada à tomografia computadorizada (PET/CT) é um dispositivo que combina as características de medicina nuclear (PET) e de radiologia (CT) obtendo imagens metabólicas (PET) e anatômicas sobrepostas (CT). Combinando as duas tecnologias de exames, o exame PET / CT permite aos médicos diagnosticar com maior precisão e identificar o câncer, doenças cardíacas e distúrbios cerebrais. O radiofármaco 18FFAc (fluoroacetato) é promissor para a detecção de tumores primários de próstata e de mama, utilizando a técnica de PET/CT. Estudos recentes mostram a eficácia do 18F-FAc na detecção de tumores que têm baixa captação de 18F-FDG (fluordesoxiglicose). O fluoroacetato é um substrato para a acetil-CoA sintase, enzima que metaboliza ácido fluorocitrato que não é mais metabolizado, levando à inibição da aconitase e do ácido tricarboxílico. O objetivo deste trabalho foi desenvolver um radiofármaco emissor de pósitron, 18F-FAc no IPEN-CNEN/SP em um acordo com o Hospital AC-Camargo / São Paulo. O íon fluoreto (18F-) foi produzido, usando os cíclotrons Cyclone 30 e 18 da IBA localizados no IPEN-CNEN/SP, através da irradiação de água enriquecida em 18O com prótons e dose integrada de 30μAh. A marcação do 18F-FAc foi realizada em um módulo de síntese TRACERlab MXFDG (GE), utilizando kits adquiridos da ABX. O controle de qualidade radioquímico de 18F-FAc foi realizado por cromatografia em camada fina TLC-SG 25 folhas de alumínio em tiras (1,5 x 12 cm ) usando como solvente clorofórmio:metanol (1:1). Para o controle de qualidade radionuclídico, amostras de 18F-FAc e 18F-Fluoreto foram analisadas por espectroscopia de raios-gama. A avaliação dos solventes residuais foi realizada por cromatografia em fase gasosa e a análise de kryptofix foi realizada por TLC utilizando tiras de TLC-SG, metanol:clorofórmio (9:1) como solvente e padrões de kryptofix 2.2.2. Os estudos de biodistribuição foram realizados com 18FFAc injetado em camundongos swiss sadios. Um procedimento reprodutível foi desenvolvido para o preparo do 18F-FAc com um rendimento de marcação de 37% (não corrigido) e 52% (corrigido para o decaimento) e estabilidade de 19 horas. A análise de controle de qualidade mostrou que o produto tinha as exigências adequadas para utilização, com pureza radioquímica superior a 99,9%. Os estudos de biodistribuição em animais sadios mostraram a esperada captação em todos os órgãos medidos com eliminação renal e intestinal.

    Palavras-Chave: positron computed tomography; radiopharmaceuticals; thin-layer chromatography; fluorodeoxyglucose; fluorine 18; nuclear medicine; diagnosis; radiology; tumor cells

  • IPEN-DOC 20550

    NEVES, LUCIO P. ; PERINI, ANA P. ; SANTOS, WILLIAN de S.; SQUAIR, PETERSON ; CALDAS, LINDA V.E. ; MAIA, ANA F.; POZZO, LORENA . Determination of the X-ray spectrum of a small animal PET/CT employing the MCNP5 Monte Carlo code. In: REUNIÃO ANUAL DA FEDERAÇÃO DE SOCIEDADES DE BIOLOGIA EXPERIMENTAL, 29., 27-30 de agosto, 2014, Caxambu, MG. Resumo... 2014. p. 36-37.

    Palavras-Chave: dosimetry; monte carlo method; positron computed tomography; cat scanning; x-ray spectra; brazilian cnen; neoplasms; diagnosis; therapy; in vivo; mice

  • IPEN-DOC 21382

    BELINATO, W.; SANTOS, W.S. ; PERINI, A.P.; NEVES, L.P.; CALDAS, L.V.E. ; SOUZA, D.N.. Dose determination by PET nuclides using virtual anthropomorphic phantoms in different postures. In: INTERNATIONAL CONFERENCE ON INDIVIDUAL MONITORING ON IONISING RADIATION, April 20-24, 2015, Burges, Belgium. Abstract... 2015. p. 143.

    Palavras-Chave: positron computed tomography; diagnosis; radiation doses; internal irradiation; phantoms; m codes

  • IPEN-DOC 23503

    BELINATO, W.; SANTOS, W.S. ; CALDAS, L.V.E. ; NEVES, L.P.; SOUZA, D.N.. Dosimetria de pacientes adultos submetidos a exames de PET/CT. In: REUNIAO ANUAL DA FEDERAÇÃO DAS SOCIEDADES DE BIOLOGIA EXPERIMENTAL, 31., 29 de agosto - 01 de setembro, 2016, Foz do Iguaçu, PR. Resumo... 2016. p. 565-565.

    Palavras-Chave: absorbed radiation doses; dosimetry; equivalent radiation doses; fluorine 18; fluorodeoxyglucose; monte carlo method; phantoms; positron computed tomography

  • IPEN-DOC 23029

    BELINATO, W.; SANTOS, W.S. ; CALDAS, L.V.E. ; NEVES, L.P.; SOUZA, D.N.. Dosimetria de pacientes adultos submetidos a exames de PET/CT. Anais da SBBN, v. 3, p. 40-40, 2016.

    Abstract: Introdução: A tomografia por emissão de pósitrons (PET) associada à tomografia computadorizada (CT), chamada PET/CT, é uma técnica diagnóstica que auxilia na determinação precisa de regiões tumorais nos pacientes. É possível determinar as doses absorvidas em adultos submetidos a exames de PET/CT por meio de simulações computacionais realizadas com o método de Monte Carlo. Dessa maneira, utilizamos o código de Monte Carlo MCNPX para realizar este estudo, como também informações contidas na ICRP 103 e ICRP 106, tanto para a técnica de PET quanto para a técnica de CT. Objetivos: O objetivo deste trabalho é, utilizando o código MCNPX, estudar as doses efetivas a partir da determinação das doses absorvidas em órgãos internos dos pacientes em decorrência de exames de PET/CT. Para isso, foram empregados simuladores antropomórficos computacionais com representação dos órgãos e estruturas internas realistas de pacientes adultos incorporados em cenários de radiação de dois equipamentos PET/CT, modelos Discovery VCT (GE) e Biograph(Siemens). Métodos: Para a determinação das doses devido ao exame de PET, o radionuclídelo18F-FDG foi distribuído uniformemente em 23 órgãos internos dos simuladores adultos e, por meio do Código MCNPX, os valores das doses absorvidas por atividade injetada no paciente determinadas. As doses absorvidas devido ao exame de CT foram simuladas após a determinação dos filtros gravata-borboleta, construídos para cada um dois equipamentos. Por fim, apresentamos a dose efetiva devido ao procedimento de PET/CT considerando parâmetros comumente utilizados em exames de pacientes adultos. Resultados: As doses efetivas estimadas nos simuladores computacionais antropomórficos adultos devido à CT são responsáveis por 14,2% e 26,3% nos equipamentos GE e Siemens, respectivamente, para um exame de PET/CT em adulto. Devido ao 18F-FDG, os coeficientes de dose para dose absorvida apresentaram um acréscimo de 30% em relação aos valores da ICRP 106. As doses efetivas para o exame de PET/CT variam com a atividade injetada no paciente e os parâmetros utilizados na tomografia. Considerando uma atividade de 370 MBqde 18F-FDG e os parâmetros 140 kVp-140 mAspara o tomógrafo GE e 130 kVp-120 mAspara o Siemens, a dose efetiva total de PET/CT foi de 8,73 mSve 11,69 mSvconsiderando-se o exame realizado em equipamento da GE e 10,37 e 13,34 mSvno equipamento Siemens para os simuladores masculino e feminino, respectivamente. A atuação do recurso Caredose 4D, reduzindo 66% do mAsda Siemens, faria com que as doses da tomografia fossem idênticas às avaliadas considerando-se o exame no equipamento da GE. Conclusão: A determinação das doses absorvidas devido ao feixe de CT e também por atividade de radiofármacoadministrada no paciente possibilita o cálculo da dose efetiva total em procedimento de PET/CT, considerando as informações contidas na ICRP 103 e ICRP 106. As doses efetivas estimadas em adultos devido ao feixe de raios X são responsáveis por 14,2% e 26,3% da dose efetiva total em um exame realizados no equipamento PET/CT GE e Siemens, respectivamente. Considerando as doses efetivas devido ao 18F-FDG, os coeficientes por atividade administrada apresentaram um acréscimo de 30% em relação aos valores da ICRP 106. Em pacientes individuais, a dose efetiva pode ser estimada a partir dos parâmetros utilizados na tomografia e dos valores de atividade de radiofármacoinjetada para a aquisição das imagens de PET.

    Palavras-Chave: absorbed radiation doses; dosimetry; equivalent radiation doses; fluorine 18; fluorodeoxyglucose; monte carlo method; phantoms; positron computed tomography

  • IPEN-DOC 24701

    ALMEIDA, LUDMILA S.; ARAUJO, MAIDANE C.; ZANTUT-WITTMANN, DENISE E.; ASSUMPCAO, LIGIA V.; SOUZA, THIAGO F.; SILVA, CLEIDE M.; ARGENTON, JULIANA L.; SANTOS, ALLAN O.; MENGATTI, JAIR ; RAMOS, CELSO D.; ETCHEBEHERE, ELBA C.. Effect of thyroid-stimulating hormone in 68Ga-DOTATATE PET/ CT of radioiodine-refractory thyroid carcinoma: a pilot study. Nuclear Medicine Communications, v. 39, n. 5, p. 441-450, 2018. DOI: 10.1097/MNM.0000000000000823

    Abstract: Background Radioiodine-refractory thyroid carcinomas (RAIRs) are characterized by reduced expression of sodium-iodine symporter, rising serum thyroglobulin levels, and negative whole-body radioiodine scans. Interestingly, RAIRs continue to express somatostatin receptors and can be identified with Ga-68-DOTATATE PET/CT imaging. Objective The objective of this study was to compare lesion detectability in Ga-68-DOTATATE PET/CT performed with elevated thyroid-stimulating hormone (eTSH) levels with suppressed thyroid-stimulating hormone (sTSH) levels. Patients and methods Fifteen patients with RAIR were prospectively enrolled in this pilot study. All patients underwent two Ga-68-DOTATATE PET/CT studies: with sTSH and with eTSH (after 30 days of levothyroxine withdrawal). All studies were blindly evaluated for differences pertaining to maximum standardized uptake values, detection of local recurrence, cervical lymph node (LN) metastases, cervical levels involved, distant LN metastases, lung metastases, and bone metastases. Reference standard consisted of fluorine-18-fluorodeoxyglucose PET/CT imaging, neck ultrasound, biopsy, and follow-up. Results Ga-68-DOTATATE PET/CT performed with both sTSH or eTSH was highly sensitive (91-100%) for detecting RAIR metastases. Ga-68-DOTATATE PET/CT with eTSH detected a higher total number of lesions (P = 0.002), higher rate of cervical and distant LN metastases (P = 0.002 and 0.0313, respectively), and significantly higher maximum standardized uptake values for cervical and distant LN metastases (P = 0.0010 and 0.0078, respectively) when compared with sTSH. Conclusion Ga-68-DOTATATE PET/CT presents a high sensitivity in detecting metastatic lesions in patients with RAIR. Detectability increases with iodine-resistance, both with and without higher thyroid-stimulating hormone levels. These findings might improve staging and subsequent treatment planning, especially with radiolabeled somatostatin analogs.

    Palavras-Chave: gallium 68; thyroid hormones; carcinomas; thyroid; somatostatin; tsh; images; computerized tomography; positron computed tomography; diagnosis

  • IPEN-DOC 27139

    TORRES, LARISSA H.; REAL, CAROLINE C.; TURATO, WALTER M.; SPELTA, LÍDIA W.; DURÃO, ANA C.C. dos S.; ANDRIOLI, TATIANA C.; POZZO, LORENA ; SQUAIR, PETERSON L. ; PISTIS, MARCO; FARIA, DANIELE de P.; MARCOURAKIS, TANIA. Environmental tobacco smoke during the early postnatal period of mice interferes with brain 18F-FDG uptake from infancy to early adulthood: a longitudinal study. Frontiers in Neuroscience, v. 14, p. 1-11, 2020. DOI: 10.3389/fnins.2020.00005

    Abstract: Exposure to environmental tobacco smoke (ETS) is associated with high morbidity and mortality, mainly in childhood. Our aim was to evaluate the effects of postnatal ETS exposure in the brain 2-deoxy-2-[18F]-fluoro-D-glucose (18F-FDG) uptake of mice by positron emission tomography (PET) neuroimaging in a longitudinal study. C57BL/6J mice were exposed to ETS that was generated from 3R4F cigarettes from postnatal day 3 (P3) to P14. PET analyses were performed in male and female mice during infancy (P15), adolescence (P35), and adulthood (P65). We observed that ETS exposure decreased 18F-FDG uptake in the whole brain, both left and right hemispheres, and frontal cortex in both male and female infant mice, while female infant mice exposed to ETS showed decreased 18F-FDG uptake in the cerebellum. In addition, all mice showed reduced 18F-FDG uptake in infancy, compared to adulthood in all analyzed VOIs. In adulthood, ETS exposure during the early postnatal period decreased brain 18FFDG uptake in adult male mice in the cortex, striatum, hippocampus, cingulate cortex, and thalamus when compared to control group. ETS induced an increase in 18F-FDG uptake in adult female mice when compared to control group in the brainstem and cingulate cortex. Moreover, male ETS-exposed animals showed decreased 18F-FDG uptake when compared to female ETS-exposed in the whole brain, brainstem, cortex, left amygdala, striatum, hippocampus, cingulate cortex, basal forebrain and septum, thalamus, hypothalamus, and midbrain. The present study shows that several brain regions are vulnerable to ETS exposure during the early postnatal period and these effects on 18F-FDG uptake are observed even a long time after the last exposure. This study corroborates our previous findings, strengthening the idea that exposure to tobacco smoke in a critical period interferes with brain development of mice from late infancy to early adulthood.

    Palavras-Chave: tobacco; tobacco smokes; nicotiana; environment; image processing; positron computed tomography; uptake; fluorodeoxyglucose; mice; glucose; longitudinal momentum; brain; children; nerve cells

  • IPEN-DOC 23524

    BELINATO, WALMIR; SANTOS, WILLIAM S. ; PERINI, ANA P.; NEVES, LUCIO P. ; CALDAS, LINDA V.E. ; SOUZA, DIVANIZIA N.. Estimate of S-values for children due to six positron emitting radionuclides used in PET examinations. Radiation Physics and Chemistry, v. 140, p. 51-56, 2017. DOI: 10.1016/j.radphyschem.2017.02.038

    Abstract: Positron emission tomography (PET) has revolutionized the diagnosis of cancer since its conception. When combined with computed tomography (CT), PET/CT performed in children produces highly accurate diagnoses from images of regions affected by malignant tumors. Considering the high risk to children when exposed to ionizing radiation, a dosimetric study for PET/CT procedures is necessary. Specific absorbed fractions (SAF) were determined for monoenergetic photons and positrons, as well as the S-values for six positron emitting radionuclides (11C, 13N, 18F, 68Ga, 82Rb, 15O), and 22 source organs. The study was performed for six pediatric anthropomorphic hybrid models, including the newborn and 1 year hermaphrodite, 5 and 10-year-old male and female, using the Monte Carlo N-Particle eXtended code (MCNPX, version 2.7.0). The results of the SAF in source organs and S-values for all organs showed to be inversely related to the age of the phantoms, which includes the variation of body weight. The results also showed that radionuclides with higher energy peak emission produces larger auto absorbed S-values due to local dose deposition by positron decay. The S-values for the source organs are considerably larger due to the interaction of tissue with non-penetrating particles (electrons and positrons) and present a linear relationship with the phantom body masses. The results of the Svalues determined for positron-emitting radionuclides can be used to assess the radiation dose delivered to pediatric patients subjected to PET examination in clinical settings. The novelty of this work is associated with the determination of auto absorbed S-values, in six new pediatric virtual anthropomorphic phantoms, for six emitting positrons, commonly employed in PET exams.

    Palavras-Chave: animal tissues; carbon 11; fluorine 18; gallium 68; emission; ionizing radiations; monte carlo method; neoplasms; organs; phantoms; positron computed tomography; radiation doses

  • IPEN-DOC 23760

    BELINATO, W.; SANTOS, W.S. ; PERINI, A.P. ; CALDAS, L.V.E. ; NEVES, L.P. ; SOUZA, D.N.. Estimate of S-values for children due to six positrons emitting radionuclides used in PET examinations. In: INTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 2nd, July 03-08, 2016, Guildford, United Kingdom. Abstract... 2016. p. P120-P120.

    Palavras-Chave: animal tissues; carbon 11; fluorine 18; gallium 68; emission; ionizing radiations; monte carlo method; neoplasms; organs; phantoms; positron computed tomography; radiation doses

  • IPEN-DOC 21250

    OLIVEIRA, RICARDO de S. . Estudo da marcação com Indio-111 e Gálio-68 de derivados da bombesina e avaliação das propriedades biológicas para aplicação em SPECT e PET / Study of labelling of bombesin derivatives with 111-indium and 68-galium and evaluation of biological properties for application in SPECT and PET . 2014. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 76 p. Orientador: Elaine Bortoleti de Araujo. DOI: 10.11606/D.85.2014.tde-08122015-085946

    Abstract: Receptores para o peptídeo liberador de gastrina (GRPr) são super expressos em vários tipos de células cancerígenas, incluindo câncer de mama e próstata. A Bombesina é um análogo do peptídeo GRP de mamíferos que se liga com alta especificidade e afinidade aos receptores do peptídeo liberador de gastrina (GRPr). Significantes pesquisas têm sido realizadas para desenvolver e radiomarcar um análogo da bombesina para diagnóstico de tumores de próstata e mama, utilizando-se técnicas de SPECT e PET, com radionuclídeos como 111In e 68Ga. O objetivo deste trabalho foi estudar a marcação com 111In de uma série inédita de peptídeos derivados de bombesina e determinar o potencial de aplicação no diagnóstico de tumores de próstata em modelos animais. Vários estudos foram realizados para padronizar o procedimento de marcação, variando-se temperatura, tempo de marcação, massa do peptídeo e atividade do radionuclídeo. Os resultados demonstraram que os análogos da bombesina estudados podem ser marcados com índio-111 com alto rendimento de marcação e alta atividade específica. Os estudos de biodistribuição em animais normais demonstraram que o derivado de BBN com espaçador aminoacídico Gly5 apresentou captação pancreática e intestinal expressiva, sugerindo ser o melhor derivado. Dois derivados DOTA- conjugados, com espaçador Gly5 foram radiomarcados com gálio-68 e investigados em modelo animal com tumor de próstata humano, indicando o potencial para aplicação do peptídeo radiomarcado no diagnóstico por PET.

    Palavras-Chave: indium 111; gallium 68; labelling; tracer techniques; amino acids; diagnosis; neoplasms; prostate; positron computed tomography; single photon emission; chromatography

  • IPEN-DOC 19090

    ZANETTE, CAMILA . Estudo da produção do radiofármaco FLT-18F em sistema automatizado: contribuição para a validação do processo / Study of the production of the radiopharmaceutical sup(18)F-FLT in automated system: Contribution for process validation . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 132 p. Orientador: Elaine Bortoleti de Araujo. DOI: 10.11606/D.85.2013.tde-04072013-140325

    Abstract: O radiofármaco FLT-18F é um análogo do nucleosídeo timidina e um promissor marcador da proliferação tumoral para imagens em PET. A síntese deste radiofármaco não é simples e, muitas vezes, apresenta baixos rendimentos. Este radiofármaco já vem sendo estudado há alguns anos, porém, não há produção, nem estudos clínicos, no Brasil. O estudo do processo produtivo e a sua adequação às diretrizes de Boas Práticas de Fabricação (ANVISA) são de extrema importância. Este trabalho teve como objetivo estudar a síntese deste radiofármaco, avaliar os métodos de controle de qualidade que serão utilizados na rotina de produção futura, realizar estudos de citotoxicidade, estudos de biodistribuição e imagens PET em animais, contribuindo para o desenvolvimento e elaboração do protocolo de validação de processo e estabelecimento das metodologias analíticas a serem utilizadas durante a rotina de produção. Inicialmente, foi estudada a síntese e produção do produto FLT-18F, com a avaliação de três temperaturas diferentes de marcação, a m de vericar o comportamento do rendimento radioquímico e a estabilidade do produto nal. Os estudos de metodologia analítica compreenderam as análises de identicação radionuclídica, determinação dos pers cromatográcos, pureza radioquímica, solventes residuais e pH. Estudos in vitro do FLT- 18F de internalização e citotoxicidade também foram feitos. Nos estudos in vivo, avaliou-se a farmacocinética, biodistribuição em animais sadios e em animais com modelos tumorais, além de imagens PET/CT de animais com melanoma. O produto nal apresentou alta pureza radioquímica e mostrou-se estável por até 10 horas após a síntese, porém obteve-se um rendimento radioquímico relativamente baixo, conforme descrito na literatura. As metodologias analíticas testadas mostraram-se adequadas para o uso no controle de qualidade do FLT-18F. Nos estudos in vitro o FLT-18F apresentou uma signicativa porcentagem de ligação às células tumorais e a molécula não radiomarcada não foi considerada tóxica para estas células estudadas. A biodistribuição e as imagens apresentaram resultados compatíveis com o esperado. As contribuições para a validação de processo foram satisfatórias e auxiliarão na validação futura do processo produtivo do radiofármaco em estudo.

    Palavras-Chave: radiopharmaceuticals; fluorine 18; isotope production; quality control; cytology; toxicity; positron computed tomography; validation; chromatography; radiochemistry

  • IPEN-DOC 27502

    CAMPOS, RAFAEL F. . Estudo de biodistribuição de radiofármaco marcado com 99mTc pelo método invasivo e não invasivo utilizando o micro PET/SPECT/CT / Biodistribution study of 99mTc-labeled radiopharmaceuticals by the invasive and non-invasive method using micro PET/SPECT/CT . 2020. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 95 p. Orientador: Elaine Bortoleti de Araújo. DOI: 10.11606/D.85.2020.tde-23122020-112629

    Abstract: As farmacopeias Europeia e Americana (USP) recomendam que estudos de controle de qualidade de radiofármacos envolvendo sistemas biológicos sejam realizados por métodos invasivos. Entretanto, esses métodos consomem tempo considerável, contribuindo para a exposição do trabalhador à radiação. Por outro lado, a imagem pré-clínica permite uma perspectiva de estudos longitudinais, com potencial para fornecer medições quantitativas de biodistribuição de radiotraçadores e reduzir o número de animais necessários por estudo, sendo mais econômico e mais ético do que os métodos tradicionais encontrados na literatura. Este trabalho avaliou o potencial do método de imagem em micro SPECT/CT na avaliação quantitativa da biodistribuição do radiofármaco DMSA-TEC marcado com 99mTc, comparando os resultados com o método invasivo. A pureza radioquímica das marcações realizadas para método não invasivo apresentou resultado em média de 90,43 ± 1,59 %, atendendo ao critério de aceitação (≥ 85%, USP). A quantificação da captação do radiofármaco nos órgãos de interesse (rins e fígado+baço) foi realizada a partir de imagens SPECT/CT, pré-processadas com o algoritmo iterativo OSEM. Os órgãos de interesse foram selecionados e o processamento das imagens foi realizado pelo software Pmod 4.0. Apesar do método não invasivo produzir resultados quantitativos de %A.I. nos rins que não atenderam ao critério farmacopeico, promoveu resultados reprodutíveis, sugerindo que o método possa ser aprimorado para aplicação na rotina de análise de lotes de radiofármacos, considerando a possibilidade de estabelecimento de correlação quantitativa com o método invasivo e a definição de critérios de aceitação próprios para o método não invasivo. A reprodutibilidade demonstrada pelo método não invasivo encoraja sua aplicação para obtenção de resultados quantitativos em estudos relacionados ao desenvolvimento de novos radiofármacos.

    Palavras-Chave: emission computed tomography; positron computed tomography; single photon emission computed tomography; image processing; quality control; peptides; radioisotopes; technetium 99; radiopharmaceuticals; labelled compounds; biological localization; post-irradiation examination; diagnostic techniques; diagnosis; experiment results; performance testing; gamma radiation

  • IPEN-DOC 11322

    SATO, RENATO C. . Estudo de demanda do radiofármaco sup(18)F-FDG nas regiões metropolitanas de São Paulo e áreas adjacentes. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Desirée Moraes Zouaim. DOI: 10.11606/D.85.2006.tde-22032012-163903

    Abstract: No Brasil e no mundo a medicina nuclear vem ganhando destaque com as técnicas diagnósticas que permitem o estudo metabólico de doenças, alterando significativamente o gerenciamento dos pacientes. Essa tecnologia inovadora vem trazendo expectativas tanto para os setores especializados como para a sociedade. Nesse trabalho foi estudada a utilização do radiofármaco 18F-FDG na região metropolitana de São Paulo e nas áreas adjacentes, bem como a estrutura do mercado atual e das dificuldades a serem superadas com o aumento da demanda do 18F-FDG. A pesquisa contou com uma análise do mercado de radiofármacos internacional e das principais alterações que vem ocorrendo nessa área no Brasil nos últimos anos. Foram realizadas entrevistas com profissionais atuantes na área de medicina nuclear e coleta de dados através de questionário enviado para os centros consumidores do radiofármaco na região coberta pela pesquisa. As entrevistas expressaram as opiniões dos entrevistados sobre as transformações nesse setor e as tendências futuras e os dados coletados no questionário serviram de complementação a utilização do radiofármaco nos equipamentos do tipo Single Photon Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) e Positron Emission Tomography / Computer Tomography (PET/CT). O maior uso do 18F-FDG tem sido para o diagnóstico oncológico nos equipamentos do tipo PET e PET/CT. Essa utilização deverá crescer nos próximos anos, podendo se expandir para outras especialidades como neurologia e cardiologia. Apesar de restrita atualmente as cidades de São Paulo e Rio de Janeiro deverá haver uma expansão dessa modalidade diagnóstica nos outros Estados do país que começam a estruturar produção do radioisótopo. A recente alteração na constituição que permite a produção e comercialização de radioisótopos de meia-vida curta também deverá aumentar o interesse da iniciativa privada nesse mercado, que internacionalmente possui projeções otimistas de crescimento. Existe também uma expectativa que a aprovação dos planos de saúde para a cobertura dos exames utilizando 18F-FDG no PET impulsione esse mercado ainda mais, repetindo a experiência internacional. Os recentes investimentos realizados pelo IPEN para aumentar a produção do 18F-FDG deverá garantir a oferta com confiabilidade, para a região Sudeste e Sul do país.

    Palavras-Chave: commercialization; fluorine 18; fluorodeoxyglucose; market; positron computed tomography; radiopharmaceuticals; supply and demand

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.