Navegação por assunto "pressure measurement"

Classificar por: Ordenar: Resultados:

  • IPEN-PUB-347

    CONTI, T.N. ; FREITAS, R.L. . Aplicacao do codigo TRACPD2 na simulacao da experiencia CANON. 1991. p.

    Palavras-Chave: t codes; reactor accidents; loss of coolant; transients; depressurization; pressure measurement; void fraction

  • IPEN-DOC 01701

    FREITAS, R.L. . Avaliacao das medidas de perda de pressao total durante a fase de remolhamento. In: 2o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 24-29 de abril, 1988, Rio de Janeiro, RJ. 1988. p. 437-446.

    Palavras-Chave: loss of coolant; pwr type reactors; rewetting; pressure measurement; boiling; two-phase flow; void fraction

  • IPEN-DOC 06169

    OLIVEIRA JUNIOR, O.P. . Calibration of absolute pressure transmitters by use of the direct comparison method according to DIN 28418. Revista Brasileira de Aplicações de Vácuo, v. 17, n. 1, p. 11-14, 1998.

    Palavras-Chave: pressure measurement; pressure regulators; high vacuum; calibration; accuracy; resolution

  • IPEN-DOC 17556

    SABUNDJIAN, GAIANE ; ANDRADE, DELVONEI A. de ; UMBEHAUN, PEDRO E. ; TORRES, WALMIR M. ; MACEDO, LUIZ A. ; CONTI, THADEU N. ; MESQUITA, ROBERTO N. de ; ANGELO, GABRIEL. Comparison between experimental data and numerical modeling for the natural circulation phenomenon. Journal of the Brazilian Society of Mechanical Sciences and Engineering, v. 33, n. 3, p. 227-232, 2011.

    Palavras-Chave: computerized simulation; experimental data; natural convection; pressure measurement; r codes; temperature dependence; thermal hydraulics; two-phase flow

  • IPEN-DOC 15276

    SABUNDJIAN, GAIANE ; ANDRADE, DELVONEI A. ; UMBEHAUN, PEDRO E. ; TORRES, WALMIR M. ; MACEDO, LUIZ A. ; CONTI, THADEU N. ; MESQUITA, ROBERTO N. ; MASOTTI, PAULO H.F. ; PENHA, ROSANI M.L.; SILVA FILHO, MAURO F.; MELO, GABRIEL R.; BRAZ FILHO, FRANCISCO A.; BORGES, EDUARDO M.. Comparison between experimental data and numerical modeling for the natural circulation phenomenon. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: computerized simulation; experimental data; natural convection; pressure measurement; r codes; temperature dependence; thermal hydraulics; two-phase flow

  • IPEN-DOC 01941

    LIMA, L.F.C.P. ; GORSKI, M.S. ; AMBROZIO FILHO, F. ; SOUSA, V.A.; BRUZINGA, W.A. ; CASTRO, A.R.M.. Desenvolvimento e caracterizacao de um absorvedor de zirconio com porosidade controlada. In: SIMPOSIO FRANCO-BRASILEIRO DE CIENCIA DOS MATERIAIS, 16-20 de marco, 1992, Ouro Preto, MG. 1992.

    Palavras-Chave: zirconium; gases; getters; pressure measurement

  • IPEN-DOC 05517

    PERILLO, S.R.P. ; SOARES, A.J. . Determinacao do tempo de resposta de transdutores de pressao utilizando o metodo de medida direta. In: 5o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 28 de agosto - 2 de setembro, 1994, Rio de Janeiro, RJ. 1994. p. 247-252.

    Palavras-Chave: transducers; pressure measurement; time dependence

  • IPEN-DOC 27763

    SAITA, MARCELO T.; BARBOSA, EDUARDO A.; DEGASPERI, FRANCISCO T.; WETTER, NIKLAUS U. . Measurement of differential pressure by optical interferometry with multimode tunable lasers. Journal of Engineering Science and Technology Review, v. 13, n. 6, p. 17-21, 2020. DOI: 10.25103/jestr.136.03

    Abstract: Determining the deformation of a capacitive membrane is a well-known pressure measurement technique. A novel technique is presented for pressure measurement based on low coherence speckle interferometry (LCSI) to optically evaluate the deformation of a membrane submitted to a pressure differential. By processing the low spatial frequency speckle fringe pattern through four-stepping and phase unwrapping methods the membrane contour was determined. A tunable multimode red diode laser is the light source. A circular aluminum membrane was submitted to pressure values up to 90 kPa resulting in a curve of the central membrane deformation as a function of the pressure. An External Cavity Diode Laser (ECDL) was used for laser tuning thus changing the interferogram spatial frequency and the sensitivity of the measurement process. The interferometry results were compared with those obtained experimentally by a feeler clock and by an analytical expression. The possibility of applying this technique in quasi real-time testing is explored.

    Palavras-Chave: optical systems; interferometry; lasers; tuning; pressure measurement; interferometers; light sources; deformation

  • IPEN-DOC 28705

    TORRES, WALMIR M. ; UMBEHAUN, PEDRO E. ; ANDRADE, DELVONEI A. . Medida de distribuição de vazão no núcleo do reator IEA-R1 usando o elemento DMPV-01. In: SILVA, PAULO S.C. da (Org.); ZAHN, GUILHERME S. (Org.); SOUZA, FRANCISCO de A. (Org.). Contribuições do reator IEA-R1 para a pesquisa nuclear. São Paulo, SP: Blucher, 2022. p. 53-59, cap. 5. DOI: 10.5151/9786555501483-05

    Abstract: O elemento dummy instumentado DMPV-01 foi usado para medir a vazão em algumas posições do núcleo do reator IEA-R1 ocupadas por elementos combustíveis (EC). A vazão foi medida nas posições dos EC no 152, 153, 169 e 170 referentes à configuração no 210a de operação do reator. Com base nas medidas efetuadas pode-se concluir que uma parcela considerável de vazão não passa através dos EC e, portanto, não contribui para o seu resfriamento. Os valores de vazão medidos foram muito menores que os valores médios teóricos estimados, os quais estavam sendo usados como dados de entrada nas análises termo-hidráulicas do núcleo. Isso significa que pode estar havendo um desvio de vazão do núcleo muito maior do que o esperado e desejado ou, que a vazão medida no circuito primário esteja incorreta. Também foram realizados testes para verificar a influência dos irradiadores presentes na configuração 210a, ou seja, o EIS (Elemento de Irradiação de Silício), os EIRA (Elemento de Irradiação Resfriado a Água) e a GI (Guia de Irradiação), na distribuição de vazão. Foi verificada também a influência da presença dos tubos porta-amostra nos orifícios do EIBE (Elemento de Irradiação de Berílio).

    Palavras-Chave: fuel elements; pressure measurement; fluid flow; calibration

  • IPEN-DOC 01696

    SILVA, A.T. ; ESTEVES, A.M.. Metodologia de projeto de varetas combustiveis de reatores de agua leve pressurizada. In: 2o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 24-29 de abril, 1988, Rio de Janeiro, RJ. 1988. p. 345-356.

    Palavras-Chave: fuel rods; pwr type reactors; pressure measurement; dimensions; computer calculations

  • IPEN-DOC 24584

    TORRES, W.M. ; UMBEHAUN, P.E. ; ANDRADE, D.A. ; SOUZA, J.A.B. . A MTR fuel element flow distribution measurement preliminary results. In: 60 YEARS OF IEA-R1: INTERNATIONAL WORKSHOP ON UTILIZATION OF RESEARCH REACTORS, November 28 - December 01, 2017, São Paulo, SP. Abstract... São Paulo, SP: Instituto de Pesquisas Energéticas e Nucleares, 2017. p. 62-63.

    Abstract: An instrumented dummy fuel element (DMPV-01) with the same geometric characteristics of a MTR fuel element was designed and constructed for flow distribution measurement experiments at the IEA-R1 reactor core. This dummy element was also used to measure the flow distribution among the rectangular flow channels formed by element fuel plates. Two probes with two pressure taps were constructed and assembled inside the flow channels to measure pressure drop and the flow velocity was calculated using pressure drop equation for closed channels. This work presents the experimental procedure and results of flow distribution measurement among the flow channels. Results show that the flow rate in the peripheral channels is 10 to 15% lower than the average flow rate. It is important to know the flow rate in peripheral channels because of uncertainties in values of flow rate in the open channel formed by two adjacent fuel elements. These flow rates are responsible by the cooling of external fuel plates.

    Palavras-Chave: cooling; experimental data; flow rate; fluid flow; fuel channels; fuel elements; fuel plates; mtr reactor; pressure drop; pressure measurement; spatial distribution; velocity

  • IPEN-DOC 06662

    MAPRELIAN, E. ; CASTRO, A.A. ; TING, D.K.S. . Onset of nucleate boiling and onset of fully developed subcooled boiling detection using pressure transducers signals spectral analysis. In: 15o. CONGRESSO BRASILEIRO DE ENGENHARIA MECANICA, 22-26 de novembro, 1999, Aguas de Lindoia, SP. 1999.

    Palavras-Chave: nucleate boiling; subcooled boiling; pressure measurement; heat transfer

  • IPEN-DOC 07189

    OLIVEIRA, W.S. . Operacao de reator de leito movel em regime estavel para producao de tetrafluoreto de uranio: aplicacao de instrumentacao apropriada. In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE FISICA DE REATORES E TERMOHIDRAULICA, 12., 15-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: uranium tetrafluoride; chemical preparation; chemical reactors; uranium trioxide; reduction; uranium dioxide; fluorination; pressure measurement; temperature measurement

  • IPEN-DOC 27335

    FREITAS, ANDERSON Z. de ; RIBEIRO, LUCAS A. de S. ; NEGRINI NETO, OSVALDO ; SARKIS, JORGE E.S. ; SIQUEIRA, ANDRESSA N. . Optical-coherence-tomography-based algorithm for handwriting forensic analysis. In: JALALI, BAHRAM (Ed.); KITAYAMA, KEN-ICHI (Ed.) SPIE PHOTONICS WEST; SPIE OPTO, February 1-6, 2020, San Francisco, USA. Proceedings... Washington, USA: SPIE, 2020. p. 112990P-1 - 112990P-8. (Proceedings SPIE 11299, AI and Optical Data Sciences). DOI: 10.1117/12.2543356

    Abstract: This work describes a new method for handwriting forensic analysis using optical coherence tomography (OCT) images. The region of interest (ROI) in documents signature to be analyzed were pre-selected with a traditional optical analyzer (Docucenter 2000 – Projectina®) equipped with different wavelengths light sources and bandpass filters coupled detector. The ROI where then submitted to OCT to 3D imaging (OCP930SR, Thorlabs Inc.) with optical resolution of 6.0 microns. One original and 5 falsified signatures were produced by 5 different individuals, using a block of 5 sheets of white sulfite paper A4 size and weight of 75 g/m^2, using the same blue ballpoint pen and in the same surface. For pressure pen calibration, were developed a system computer controlled to maintain the pressure constant during writing linear traces, 15 different pressure configuration were applied to each linear trace, resulting in a relation between deformation and applied pressure. An autonomous algorithm was developed to make surface detection, across OCT tomographic images, correct the paper surface curvature, detect and measure deformation on paper due to pen pressure, generating a new image in false color from differential pressure, based in previous calibration. This new image can be considered as a “fingerprint pressure” signature. This methodology may assist the forensic expert in correctly determining the authorship of a signature.

    Palavras-Chave: coherent radiation; tomography; crime detection; nuclear forensics; pressure measurement; hands

  • IPEN-DOC 07222

    SCIANI, V. ; MATSUDA, H. ; LAPOLLI, A.L. ; SUMIYA, L.C.A. ; COSTA, O.L. ; LIMA, W. . Parametros relevantes na irradiacao de agua enriquecida em ciclotron, visando a otimizacao e a seguranca operacional na obtencao do ion sup(18)Fsup(-). In: CONGRESSO GERAL DE ENERGIA NUCLEAR, 8.; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 5., 5-20 out, 2000, Rio de Janeiro, RJ. Anais... Rio de Janeiro: ABEN, 2000, 2000.

    Palavras-Chave: fluorine 18; isotope production; cyclotrons; optimization; irradiation; water; monitoring; control systems; pressure measurement; temperature measurement; thermocouples

  • IPEN-DOC 25931

    SAITA, MARCELO T.; BARBOSA, EDUARDO A.; DEGASPERI, FRANCISCO T.; WETTER, NIKLAUS U. . Pressure measurement by low coherence speckle interferometry membrane shaping with tunable diode lasers. In: SBFOTON INTERNATIONAL OPTICS AND PHOTONICS CONFERENCE, October 08-10, 2018, Campinas, SP. Proceedings... Piscataway, NJ, USA: IEEE, 2018. DOI: 10.1109/SBFoton-IOPC.2018.8610915

    Abstract: Non-contact evaluation of object deformation is of great importance in several industrial and scientific processes. In this work the demonstrate that low-coherence digital speckle pattern interferometry can be employed for pressure measurement by the analysis of a 0.4-mm thickness, 55-mm diameter circular aluminum membrane submitted to a pressure differential ranging from 0 to 90 kPa. The membrane deformation was measured with a tunable red diode laser emitting simultaneously two wavelengths. The resulting speckle image of the membrane appeared covered with interference fringes which correspond to the contour lines of the studied surface. By means of conventional fringe pattern evaluation methods like 4-stepping and unwrapping methods the membrane deformation was determined. The experimental results were compared with the ones obtained by a numerical algorithm.

    Palavras-Chave: interferometry; optical equipment; deformation; measuring methods; pressure measurement; lasers; laser cavities

  • IPEN-DOC 07636

    PERILLO, S.R.P. ; GONCALVES, I.M.P. ; SANTOS, R.C. ; TING, D.K.S. . Response time measurement of temperature and pressure sensors of Angra-I nuclear power plant using noise analysis technique. In: CONGRESSO BRASILEIRO DE ENGENHARIA MECANICA, 16., 26-30 nov, 2001, Uberlandia, MG. 2001.

    Palavras-Chave: angra-1 reactor; reactor protection systems; temperature measurement; pressure measurement; reactor safety

  • IPEN-DOC 08322

    CUNHA, A.G.; ORLANDO, M.T.D.; ALVES, K.M.B.; MARTINEZ, L.G. ; EMMERICH, F.G.; SAITOVITCH, E.B.. Rhenium effect in the formation and stability of HgCaOsub(2) and Hgsub(1-x)Resub(x)Basub(2)Casub(2)Cusub(3)Osub(8+delta) superconductor. Physica C, v. 356, n. 1/2, p. 97-106, 2001.

    Palavras-Chave: superconductors; ceramics; synthesis; mercury oxides; calcium oxides; rhenium oxides; barium oxides; copper oxides; thermobaric analysis; pressure measurement; thermodynamic properties

  • IPEN-DOC 15277

    TORRES, WALMIR M. ; MACEDO, LUIZ A. ; MESQUITA, ROBERTO N. ; MASOTTI, PAULO H.F. ; LIBARDI, ROSANI M.P. ; SABUNDJIAN, GAIANE ; ANDRADE, DELVONEI A. ; UMBEHAUN, PEDRO E. ; CONTI, THADEU N. ; FILHO, MAURO F.S.; MELO, GABRIEL R.. Thermal hydraulic phenomenology for the heating process in a natural circulation facility. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: experimental data; flow rate; heat flux; natural convection; pressure measurement; temperature dependence; thermal hydraulics; transducers; two-phase flow; void fraction

  • IPEN-DOC 12186

    GONCALVES, IRACI M. P. ; SANTOS, ROBERTO C. dos ; LOPES, WAGNER J. dos R.; NAPOLITANO, OLIVIO da C.. Time response measurements of angra I nuclear power plant using direct and indirect methodologies. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: angra-1 reactor; numerical data; power density; pressure measurement; reactor instrumentation; reactor operation; temperature measurement

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.