Navegação por assunto "prostheses"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 27560

    JALKH, ERNESTO B.B.; MONTEIRO, KELLI N.; CESAR, PAULO F.; GENOVA, LUIS A. ; BERGAMO, EDMARA T.P.; LOPES, ADOLFO C. de O.; LIMA, ERICK; LISBOA-FILHO, PAULO N.; CAMPOS, TIAGO M.B.; WITEK, LUKASZ; COELHO, PAULO G.; BORGES, ANA F.S.; BONFANTE, ESTEVAM A.. Aging resistant ZTA composite for dental applications: microstructural, optical and mechanical characterization. Dental Materials, v. 36, n. 9, p. 1190-1200, 2020. DOI: 10.1016/j.dental.2020.05.011

    Abstract: Objective. To synthesize a zirconia toughened alumina (ZTA) composite with 70% aluminareinforced by 30% zirconia for dental applications and to characterize its microstructureand optical properties for comparison with the isolated counterpart materials and a first-generation 3Y-TZP.Methods. Disc-shaped specimens were divided in four groups (n = 70/material): (1) 3YSB-E(first generation 3Y-TZP), (2) Zpex (second generation 3Y-TZP), (3) alumina, and (4) ZTA-Zpex70/30. After synthesis, ceramic powders were pressed, and green-body samples sinteredfollowing a predetermined protocol. Specimens were polished to obtain a mirror surfacefinish. Apparent density was measured by Archimedes principle. X-ray diffraction (XRD)and scanning electron microscope (SEM) were used to characterize the crystalline contentand microstructure. Reflectance tests were performed to determine the contrast-ratio (CR)and translucency-parameter (TP). Mechanical properties were assessed by biaxial flexuralstrength (BFS) test. All analyses were conducted before and after artificial aging (20 h, 134◦C, 2.2 bar). Optical parameters were evaluated through repeated-measures analysis of variance and Tukey tests (p < 0.05). BFS data were analyzed using Weibull statistics (95% CI). Results. High density values (95–99%) were found for all ceramic materials and SEM images exhibited a dense microstructure. While XRD patterns revealed the preservation of crys- talline content in the ZTA composite, an increase in the monoclinic peak was observed for pure zirconias after aging. Significantly higher CR and lower TP values were observed for the ZTA composite, followed by alumina, 3YSB-E, and Zpex. The highest characteristic stress was recorded for 3YSB-E, followed by intermediate values between ZTA and Zpex, and the lowest for alumina. Aging affected the optical and mechanical properties of both zirconias, while remained stable for ZTA composite and alumina. Significance. The synthesis of experimental 70−30% ZTA composite was successful and its relevance for dental applications relies on its higher masking ability, aging resistance, and strength similar to zirconia.

    Palavras-Chave: composite materials; zirconium oxides; aluminium oxides; mechanical properties; optical properties; microstructure; dentistry; prostheses

  • IPEN-DOC 27599

    MICELLI, ANA L.P. ; NIGRO, FREDERICO ; MUCSI, CRISTIANO S. ; ALENCAR, MAICON C. de ; ARANHA, LUIS C. ; ROSSI, JESUALDO L. . Analysis of the pullout testing of straight and angled abutments in narrow diameter implants. Materials Science Forum, v. 1012, p. 461-465, 2020. DOI: 10.4028/www.scientific.net/MSF.1012.461

    Abstract: Despite the success of osseointegrated implants, some biomechanical problems such as loosening or fracture of the abutment, crown fixation screw loosening and prosthetic instability, are common problems reported in the literature. Thus, the objective of the present study was to analyze the pullout resistance of straight and angled abutments in narrow diameter implants installed by means of friction. The specimen was composed of an implant of 3.3 mm x 11 mm fixed 2 mm above of a resin block. The abutments were fixed by friction receiving 3, 5 and 7 strikes of 0.05 J along the implant axis, and were positioned with 0˚, 10˚ and 20˚ of angulation. The abutments were subjected to pullout load, totalizing 10 repetitions for each test, i.e., the abutment was reinserted up to 10 times in the same implant. The results showed higher values of pullout load for the abutments with 7 strikes, and no statistical difference with 5 strikes suggesting better mechanical stability.

    Palavras-Chave: implants; dentistry; bone tissues; testing; prostheses; teeth; extraction; connectors

  • IPEN-DOC 05188

    QUEIROZ, A.A.A.; JULIO, C.A.; HIGA, O.Z. ; GENOVA, L.A. ; BRESSIANI, J.C. ; BRESSIANI, A.H.A. . Aplicacao da radiacao ionizante na obtencao de materiais para a engenharia biomedica e biotecnologia. In: 2o. ENCONTRO NACIONAL DE BIOMATERIAIS, 15 de outubro, 1993, Sao Paulo, SP. 1993.

    Palavras-Chave: graft polymers; implants; prostheses; ionizing radiations

  • IPEN-DOC 02843

    VALENTE, M.C. ; BRESSIANI, A.H.A. . Aspectos microestruturais da hidroxiapatita utilizada em biomateriais. In: 40o. CONGRESSO BRASILEIRO DE CERAMICA, 12-15 de junho, 1996, Criciuma, SC. Resumo... 1996. p. 82.

    Palavras-Chave: biological materials; microstructure; titanium alloys; dip coating; sol-gel process; prostheses; scanning electron microscopy; x-ray diffractometers

  • IPEN-DOC 16142

    MAIZATO, MARINA J.S.; HAYASHIDA, SERGIO A.; TANIGUCHI, FABIO P.; HIGA, OLGA Z. ; PITOMBO, RONALDO N.M.; CESTARI, IDAGENE A.; LEIRNER, ADOLFO A.. Avaliacao in vitro e in vivo de valvulas biologica liofilizada. In: LATIN AMERICAN CONGRESS OF ARTIFICIAL ORGANS AND BIOMATERIALS, 6th, August 17-20, 2010, Gramado, RS. Proceedings... 2010.

    Palavras-Chave: biological materials; valves; cattle; pericardium; prostheses; lyophilization; in vivo; in vitro; hydrodynamics

  • IPEN-DOC 23570

    NIGRO, F. ; ARANHA, L.C. ; MUCSI, C.S. ; ROSSI, J.L. . Avaliação da adaptação e resistência à remoção de pilar impactado em implante dentário cone Morse de pequeno diâmetro. In: WORKSHOP OF APPLIED CRYSTALLOGRAPHY TO MATERIALS SCIENCE AND ENGINEERING, 7th; ENCONTRO DE FISICA APLICADA, 7th, 11-13 de maio, 2016, Serra, ES. Proceedings... 2016. p. 37-40.

    Abstract: Dental implants of alloy Ti6Al4V (grade V) of narrow diameter came solve a constant situation in the current implantology, which would be the installation of implants in reduced mesiodistal spaces, mainly to allow a final prosthesis with appropriate aesthetic requirement. Because it is a 2-part system, the installation of the abutment, made in the same alloy, is performed by impaction because its stabilization through a screw becomes inconsistent due to difficulties in machining such tiny components. The abutment after impaction in various ways in the implants were sectioned at 2 mm from the implant platform and the two halves were observed in a scanning electron microscope (SEM), in order to measure the gap or the space between the implant/ abutment. Similarly, after the abutments were impacted in the implants, they were subjected to tensile test to evaluate their required removal force. This study aimed to evaluate the accuracy, the juxtaposition of these parts in the Morse-type connection and the force required to remove the abutment in order to check whether they were greater than the force of chewing.

    Palavras-Chave: dentistry; teeth; implants; prostheses; cones; removal

  • IPEN-DOC 20517

    PESQUEIRA, D.S.; PESQUEIRA, E.I.O.; SESMA, N.; LAGANÁ ; ROSSI, J.L. . Avaliação da força de deslocamento e das propriedades mecânicas de componentes protéticos lisos e indexados para implantes Cone Morse através de ensaios de tração. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 21., 9-13 de novembro, 2014, Resumo... 2014. p. 5613.

    Palavras-Chave: implants; prostheses; mechanical tests; tensile properties; scanning electron microscopy

  • IPEN-DOC 19598

    MAEDA, N.T.; YOSHIMOTO, M.; ALLEGRINI JUNIOR, S.; SALLES, M.B.; BRESSIANI, A.H.A. . Avaliação da neoformação óssea em coelhos utilizando cúpula de hidroxiapatita associada a diferentes materiais. In: CONGRESSO BRASILEIRO DE CERAMICA, 57.; CONGRESSO IBEROAMERICANO DE CERÂMICA, 5., 19-22 de maio, 2013, Natal, RN. Anais... 2013.

    Palavras-Chave: apatites; biological repair; prostheses; rabbits; tibia; bone tissues

  • IPEN-DOC 19218

    MAEDA, NANCY T. . Avaliação da neoformação óssea em tíbia de coelhos utilizando cúpula de hidroxiapatita associada a diferentes biomateriais / Evaluation of new bone formation in rabbits using hydroxyapatite dome associated to different materials . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 78 p. Orientador: Ana Helena de Almeida Bressiani. DOI: 10.11606/D.85.2013.tde-15102013-134457

    Abstract: A instalação de implantes odontológicos requer a presença de substrato ósseo adequado para garantir estabilidade e equilíbrio biomecânico. A deficiência óssea requer procedimentos de enxertia para adequar o volume para a instalação de implantes, porém a utilização de enxertos autógenos causa aumento de morbidade ao paciente e o uso de material homógeno e xenógeno apresenta dúvidas quanto à reação autoimune, transmissão de doenças e ao grau de reabsorção do enxerto. Com o grande desenvolvimento científico e tecnológico dos biomateriais, os materiais cerâmicos, tornaram-se alternativas promissoras para a recomposição da estrutura óssea perdida. As cerâmicas à base de fosfato de cálcio como a hidroxiapatita (HA) e o beta- fosfato tricálcido (beta-TCP), são materiais que apresentam qualidades desejáveis no processo de neoformação óssea como, por exemplo, a biocompatibilidade, bioatividade e osteocondutividade. A proposta deste trabalho é desenvolver e estudar corpos de prova na forma de cúpula oca de hidroxiapatita preenchidos por coágulo, beta- TCP e composto vitamínico, para estudar a osteogênese supracortical, a partir do potencial osteocondutor da cúpula de HA. As cúpulas foram obtidas por prensagem isostática a 200 MPa e sinterização ao ar a 1100°C por 60 minutos. As caracterizações físico-químicas das matérias-primas e da cúpula de HA foram realizadas por difração de raios X, microscopia eletrônica de varredura e determinação da densidade. Na caracterização biológica, foram realizados o teste de citotoxicidade in vitro e ensaio in vivo. Foram designados 9 coelhos (raça Nova Zelândia), sendo instaladas 18 cúpulas, divididas em três grupos, de acordo com o preenchimento: controle, composto vitamínico e &beta;-TCP em forma de pó. O período de reparação tecidual foi de 8 semanas, no qual foram aplicados marcadores de fluorescência. Após o período de cicatrização e eutanásia, as amostras foram incluídas em resina para a obtenção das lâminas e observadas em microscópio de fluorescência, para avaliar a quantidade de tecido ósseo neoformado, em microscópio de campo claro, para verificar as células presentes no tecido formado e por Espectroscopia de Energia Dispersiva, para análise química, da formação no interior das cúpulas. Como resultados, a cúpula de hidroxiapatita apresenta bom desempenho como arcabouço para neoformação óssea acima da cortical da tíbia de coelhos, pois manteve-se íntegra, com boa estabilidade e boa integração ao tecido ósseo, e principalmente pela neoformação óssea, demonstrando seu potencial osteocondutor. Em relação aos materiais de preenchimento, o beta-TCP apresenta maior valor de área de osso neoformado, em comparação com o coágulo. Nas cúpulas com preenchimento de composto vitamínico, não há formação de tecido ósseo pela não reabsorção do material.

    Palavras-Chave: biological materials; ceramics; prostheses; bone cells; rabbits; vitamins; calcium phosphates; beta sources; energy spectra; x-ray diffraction; x-ray spectroscopy; x-ray fluorescence analysis; scanning electron microscopy; density functional method; in vitro; in vivo; toxicity

  • IPEN-DOC 12699

    CARDOSO, LORENA M. . Avaliação da resistência a flexão de liga de titânio submetida a soldagens laser e TIG, visando a prótese dentária. 2007. Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo , Sao Paulo, Sao Paulo. 58 p. Orientador: Wagner de Rossi. Coorientador: Jose Luiz Large-Marques.

    Palavras-Chave: titanium alloys; aluminium alloys; vanadium alloys; flexural strength; laser radiation; welding; teeth; prostheses

  • IPEN-DOC 19843

    PIERETTI, EURICO F.; CORREA, OLANDIR V. ; LEIVAS, TOMAZ P.; NEVES, MAURICIO D.M. das . Avaliação do acabamento superficial do aço inoxidável austenítico ABNT NBR ISO 5832-1, marcado a laser, utilizado como biomaterial. In: CONFERÊNCIA SOBRE TECNOLOGIA DE EQUIPAMENTOS, 12., 18-21 de junho , 2013, Porto de Galinhas, PE. Anais... 2013.

    Palavras-Chave: stainless steels; biological materials; roughness; laser beam machining; prostheses

  • IPEN-DOC 05192

    BRAGA, F.J.C. . Bioceramica: tecnica avancada para o entendimento da interacao entre a estrutura ossea e TiOsub(2). In: 37o. CONGRESSO BRASILEIRO DE CERAMICA, 22-25 de maio, 1993, Curitiba, PR. 1993. p. 1208-1215.

    Palavras-Chave: implants; prostheses; ceramics; skeleton; titanium oxides; compatibility

  • IPEN-DOC 21708

    PIERETTI, EURICO F. ; LEIVAS, TOMAZ P.; COSTA, ISOLDA . Biomateriais: correlação entre as propriedades eletrônicas do filme passivo e a resistência à corrosão do aço inoxidável ABNT NBR ISO 5832-1. In: CONGRESSO BRASILEIRO DE CORROSAO, 32.; INTERNATIONAL CORROSION MEETING, 4th, May 14‐18, 2012, Salvador, BA. Proceedings... 2012. p. 1-9.

    Abstract: Este trabalho tem o objetivo de avaliar o efeito de duas técnicas de marcação de implantes metálicos na resistência à corrosão do aço inoxidável austenítico ABNT NBR ISO 5832-1, um dos materiais mais utilizados no Brasil na fabricação de próteses. Para este estudo foram preparadas amostras do referido aço marcadas com técnicas de marcação mecânica e à laser e, sem nenhum tipo de marcação. Os ensaios eletroquímicos realizados constaram de monitoramento do potencial de corrosão em circuito aberto, espectroscopia de impedância eletroquímica (EIS), determinação das propriedades eletrônicas do filme passivo via abordagem de Mott-Schottky e, medidas de polarização potenciodinâmica cíclica, à temperatura de 37°C. O eletrólito utilizado foi uma Solução Salina de Fosfato Tamponada (PBS) de pH de 7.4. Os ensaios eletroquímicos indicaram que a marcação do tipo laser aumenta a susceptibilidade à corrosão por pite ao alterar significativamente as características do filme passivo, quando comparada à marcação mecânica.

    Palavras-Chave: stainless steels; implants; corrosion resistance; austenitic steels; surgical materials; prostheses

  • IPEN-DOC 05731

    JULIO, C.A.; QUEIROZ, A.A.A.; HIGA, O.Z. ; MARQUES, E.F.; MAIZATO, M.J.S.. Blood compatibility of tubular polymeric materials studied by biological surface interactions. Brazilian Journal of Medical and Biological Research, v. 27, n. 11, p. 2565-2568, 1994.

    Palavras-Chave: blood; polymers; prostheses; cardiovascular system

  • IPEN-DOC 05190

    PURCHIO, R.A.J.; ZAVAGLIA, C.A.C.; BRESSIANI, J.C. . Caracterizacao mecanica da zirconia tetragonal policristalina, com adicoes de itria, para uso em cabeca de femur de proteses ortopedicas. In: 2o. ENCONTRO NACIONAL DE BIOMATERIAIS, 15 de outubro, 1993, Sao Paulo, SP. Resumo expandido... 1993.

    Palavras-Chave: zirconium oxides; yttrium oxides; mechanical properties; prostheses; bone joints; femur

  • IPEN-DOC 15951

    COSTA, D.P.T.S.; GUIMARAES, R.P.; CARDOSO, R.M.; MOTA, C.C.B.O.; FREITAS, A.Z. ; GOMES, A.S.L.; SILVA, C.H.V.; BEATRICE, L.C.S.. Caracterização de agentes cimentantes resinosos através de Tomografia por Coerência Óptica. Brazilian Oral Research, v. 24, n. Supl. 1, p. 265, 2010.

    Palavras-Chave: teeth; tomography; optical properties; resins; fiberglass; prostheses

  • IPEN-DOC 19129

    PIERETTI, EURICO F.; LEIVAS, TOMAZ P.; MAXIMO, ARTHUR; RAELE, MARCUS P. ; ROSSI, WAGNER de ; NEVES, MAURICIO D.M. das . Caracterização do efeito da gravação a laser na superfície do aço inoxidável austenitico ABNT NBR ISO 5832-1, utilizando implantes ortopédicos. In: CONGRESSO INTERNACIONAL ANUAL DA ABM, 68th, July 30 - August 2, 2013, Belo Horizonte, MG. Proceedings... 2013.

    Palavras-Chave: stainless steels; biological materials; roughness; laser beam machining; prostheses

  • IPEN-DOC 20486

    MARQUES, ROGERIO A.; PIERETTI, EURICO F. ; MARTIN, RAMON V.; NEVES, MAURICIO D.M. das; COSTA, ISOLDA . Caracterização magnética do aço inoxidável AISI 444 para aplicações odontológicas. In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 21., 9-13 de novembro, 2014, Cuiabá, MT. Anais... 2014. p. 5058-5062.

    Palavras-Chave: biological materials; stainless steels; ferritic steels; magnetic materials; prostheses; dentistry

  • IPEN-DOC 28471

    BRAGUIN, LILIAN N.M. . Caracterização química, eletroquímica e de citotoxicidade do aço inoxidável AISI 316L para uso como biomaterial / Chemical, electrochemical and of cytotoxicity characterization of AISI 316L stainless steel for use as biomaterial . 2021. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 138 p. Orientador: Mitiko Saiki. DOI: 10.11606/D.85.2021.tde-22102021-121119

    Abstract: O aço inoxidável austenítico produzido de acordo com a norma ISO 5832-1 é muito utilizado para atender a alta demanda para aplicações em próteses ortopédicas no Brasil. Entretanto, este biomaterial em contato com os fluidos corpóreos pode corroer e liberar elementos que causam reações biológicas adversas para o organismo. Consequentemente, estudos sobre biomateriais são de grande importância para o seu desenvolvimento ou aprimoramento. Na presente pesquisa foram avaliados os elementos da liga ISO 5832-1, a sua corrosão em diferentes soluções corpóreas simuladas e a sua citotoxicidade in vitro. Para análise elementar da liga e dos seus produtos de corrosão foi aplicada a análise por ativação com nêutrons (NAA). Para o controle analítico destes resultados foram analisados os materiais de referência certificados (MRCs) de ligas e uma solução de referência certificada. Para análise metalográfica foram feitos o ataque eletrolítico e a análise da superfície por microscopia óptica (MO) e microscopia eletrônica de varredura (MEV). A corrosão da liga foi estudada por meio de ensaios eletroquímicos e de imersão nos meios das soluções corpóreas simuladas de NaCl, fosfato tampão salino (PBS) e fluido corpóreo simulado (SBF). Nos ensaios eletroquímicos foram obtidas as curvas de variação do potencial de circuito aberto (OCP) e de polarização anódica. As superfícies da liga ISO 5832-1 expostas à corrosão foram analisadas por MEV e para avaliar a morfologia da corrosão foi realizado o ataque eletrolítico e posterior análise da superfície por MO, e no caso de PBS por MEV. O ensaio de citotoxicidade foi realizado pelo método incorporação do vermelho neutro. Os resultados do controle da qualidade analítica indicaram a viabilidade de aplicar a NAA, visto que para maioria dos elementos foram obtidos dados com uma boa precisão e exatidão. Na análise da liga foram quantificados Cr, Cu, Mn, Mo e Ni e as suas frações mássicas indicaram que estão dentro das faixas dos valores da ABNT NBR ISO 5832-1 e também As, Co, Fe, V e W que não estão apresentados na especificação foram determinados. Na análise metalográfica foram visualizados os contornos de grãos da fase austenita e maclas. Os resultados das curvas de OCP e de polarização anódica e as análises por MEV mostraram que a liga ISO 5832-1 apresenta uma maior tendência à corrosão localizada (em fresta e por pite) em NaCl do que em PBS e SBF. Na análise das micrografias por MO e MEV após os ensaios confirmaram que em NaCl, a liga apresentou maior corrosão. Nas soluções corpóreas simuladas contendo os produtos de corrosão da liga dos ensaios eletroquímicos foram identificados os elementos Cr, Fe e Ni. Os resultados dos ensaios de corrosão da liga ISO 5832-1 por imersão não indicaram a ocorrência da corrosão nas soluções de NaCl, PBS e SBF uma vez que na NAA dos produtos de corrosão não foram detectados os elementos da liga e as micrografias por MEV das superfícies da liga não revelaram a corrosão. No ensaio de citotoxicidade a liga ISO 5832-1 apresentou comportamento não citotóxico mostrando a possibilidade desta liga ser biocompatível.

    Palavras-Chave: biological materials; prostheses; stainless steels; corrosion protection; neutron activation analysis; metallography; electrolytic cells; surface properties; etching; optical microscopy; toxicity; bioassay; in vitro

  • IPEN-DOC 09386

    SAIKI, M. ; ROGERO, S.O. ; COSTA, I. ; DANTAS, E.S.K. ; OLIVEIRA, M.C.L.. Characterization of corrosion products from Nd-Fe-B magnets used in dental prostheses. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1, p. 1090-1092, 2002.

    Palavras-Chave: permanent magnets; neodymium alloys; iron alloys; boron alloys; multi-element analysis; neutron activation analysis; corrosion; corrosion products; toxicity; prostheses; dentistry

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.