Navegação por assunto "quality management"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 25780

    VELO, A.F. ; ALVAREZ, A.G. ; HAMADA, M.M. ; MESQUITA, C.H. . Image quality analysis of an industrial instant non-scanning tomography system with different collimators. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-14, 2019. DOI: 10.15392/bjrs.v7i2A.561

    Abstract: An instant non-scanning tomography system is being developed at the IPEN. This type of tomography system, due to its configurations, provides a low spatial resolution; however, it presents a high temporal resolution as an advantage. In this sense, it has high applicability in industrial processes involving dynamic multiphase processes, like distillation columns. Thereby, to obtain the best conditions of image acquisition, this tomography system comprising different collimators was simulated with Monte Carlo using the MCNP4C.The image quality was evaluated with Matlab® 2013b analyzing the contrast to noise ratio (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to identify which collimator fits better to the tomography in development. It was simulated three situations; (i) with no collimator; (ii) ø 25x 50 mm2 cylindrical collimator with a septum of ø5.0 x 50 mm2; (iii) ø25 x 50 mm2 cylindrical collimator with a slit septum of 24 x 5.0 x 50 mm3. RMSE values for no collimator presented better results. CNR showed that no collimator and slit collimator reaches the same CNR values, but no collimator decreases more than the slit collimator as the number of iteration rises. The hole collimator reaches a higher CNR value, however decreases more than the others. The spatial resolution with no collimator and slit collimator were around 31.9 mm, and for the hole collimator was around 20 mm.

    Palavras-Chave: collimators; tomography; computerized tomography; computerized simulation; monte carlo method; quality assurance; quality management; image processing; nai detectors; signal-to-noise ratio; radiation detectors; radiation detectors; industrial plants; brazilian cnen

  • IPEN-DOC 25801

    TAPPIZ, B. ; MOREIRA, E.G. . Neutron activation analysis characterization procedures for fish consumed at São Paulo city. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-9, 2019. DOI: 10.15392/bjrs.v7i2A.710

    Abstract: The characterization of edible tissues of fishes consumed by humans is very important for determination of sev-eral toxic and potentially toxic elements, ensuring the food safety. The Instrumental Neutron Activation Analysis (INAA) comparative method allows the determination of several of these elements, as well as others, for example of nutritional character. This study is part of an International Atomic Energy Agency (IAEA) technical coopera-tion project of Latin America and Caribbean countries to ensure the quality of food and biomonitoring of con-taminants in shellfish and fishes. Ten specimens of 4 of the most consumed fish in São Paulo city: whitemouth croaker (Micropogonias Furnieri), smooth weakfish (Cynoscion learchus), common snook (Centropomus undeci-malis) and Brazilian sardine (Sardinella brasiliensis) were analyzed. Complete procedures for analysis, which includes purchase in the largest warehouse in Latin America, transport to the laboratory, storage, freeze-drying, milling, weighting and others preparations of the subsamples, and the short irradiation parameters for the de-termination of Br, Cl, K, Mg, Mn and Na are reported. Results obtained under the same irradiation conditions for reference materials (oyster and mussel tissues) for macro and microelements are presented and are in agreement with their certificates, which indicate that the performed analyses were appropriate. Regarding to the mass fraction values obtained for the fish samples, they were in agreement with the literature.

    Palavras-Chave: neutron activation analysis; fishes; brazil; contamination; gamma spectroscopy; quality assurance; quality management; high-purity ge detectors; radioisotopes; food; quality control

  • IPEN-DOC 24041

    TAPPIZ, BRUNO ; MOREIRA, EDSON G. . Neutron activation analysis characterization procedures for fish consumed at São Paulo City. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The characterization of edible tissues of fishes consumed by humans is very important for determination of several toxic and potentially toxic elements, ensuring the food safety. The Instrumental Neutron Activation Analysis (INAA) comparative method allows the determination of several of these elements, as well as others, for example of nutritional character. This study is part of the International Atomic Energy Agency (IAEA) technical cooperation project of Latin America and Caribbean countries to ensure the quality of food and biomonitoring of contaminants in molluscs and fishes. Ten specimens of 5 of the most consumed fish in São Paulo city: whitemouth croaker (Micropogonias Furnieri), smooth weakfish (Cynoscion learchus), common snook (Centropomus undecimalis), Brazilian sardine (Sardinella brasiliensis) and bluefish (Pomatomus Saltatrix) were analyzed. Complete procedures for analysis, which includes purchase in the largest warehouse in Latin America, transport to the laboratory, storage, freeze-drying, milling, weighting and others preparations of the subsamples, and the short irradiation parameters for the determination of Br, Cl, K, Mn and Na are reported. Results obtained for macro and microelements are presented and are in agreement with analysis of oyster tissue and mussel tissue certified reference materials under the same irradiation conditions, with z-score values ranging from -3.0 to 2.2.

    Palavras-Chave: contamination; cooperation; fishes; high-purity ge detectors; neutron flux; quality assurance; quality management; radioisotopes; toxicity

  • IPEN-DOC 24294

    SALVETTI, TEREZA C. . Proposta para implantação de sistema de gestão integrado para unidade de tratamento e armazenamento de rejeitos radioativos de baixo e médio níveis de radiação do empreendimento RMB / Proposal for implementation of the integrated management system for radioactive waste treatment and storage unit of low and medium radiation levels of the Project RMB . 2017. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 118 p. Orientador: Júlio Takehiro Marumo. DOI: 10.11606/D.85.2018.tde-29012018-141210

    Abstract: O Reator Multipropósito Brasileiro (RMB) é um projeto que está sendo desenvolvido pela Diretoria de Pesquisa e Desenvolvimento (DPD), da Comissão Nacional de Energia Nuclear (CNEN), com o objetivo principal de suprir o país com radioisótopos para aplicação médica (saúde), indústria, agricultura e meio ambiente. Este empreendimento possui vários estágios de desenvolvimento, cada um deles com etapas que envolvem conhecimentos muito específicos para a operacionalização efetiva de suas instalações, além de detalhes legais e regulamentares que precisam ser atendidos. O Instituto Brasileiro do Meio Ambiente e dos Recursos Naturais Renováveis (IBAMA) e a Comissão Nacional de Energia Nuclear (CNEN) são, respectivamente, os responsáveis pelo licenciamento ambiental e nuclear. Nesses órgãos licenciadores pode-se encontrar diretrizes para elaborar a documentação necessária aos processos de licenciamento para Instalações Nucleares e Instalações Radiativas, porém não foi possível identificar claramente algumas diretrizes para as instalações dedicadas a tratamento e armazenamento de Rejeitos Radioativos. O Empreendimento RMB irá gerar rejeito radioativo e contará com uma instalação para tratamento, acondicionado e armazenamento, para o qual haverá também a necessidade de se gerar documentação específica dedicada ao processo de licenciamento. Diante da lacuna na diretriz de estruturação e elaboração dos documentos específicos para este tipo de instalação, foi necessário realizar um levantamento de leis, regulamentos e normas relacionados a este tipo de negócio e que serão adotadas como referência na estruturação de tais documentos. O objetivo deste trabalho foi realizar um levantamento e alinhamento das leis, regulamentos e normas aplicáveis, estruturando os requisitos em um Sistema de Gestão (SG), cujo escopo abrange o tratamento e armazenamento dos rejeitos radioativos do RMB. Este SG deverá fornecer diretrizes para a elaboração dos documentos de licenciamento e promover a gestão dos rejeitos radioativos gerados pelo RMB, bem como, deverá abordar as melhores práticas, de maneira a observar a segurança da instalação e processos envolvidos.

    Palavras-Chave: radioactive waste management; radioactive waste processing; radioactive waste facilities; nuclear waste policy acts; quality assurance; quality control; quality management; rmb reactor; brazil

  • IPEN-DOC 24144

    VELO, ALEXANDRE F. ; CARVALHO, DIEGO V. ; ALVAREZ, ALEXANDRE G. ; HAMADA, MARGARIDA M. ; MESQUITA, CARLOS H. . Reconstructed image quality analysis of an industrial instant non-scanning tomography system with different types of collimators by the Monte Carlo Simulation. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The greatest impact of the tomography technology application currently occurs in medicine. The great success of medical tomography is due to the human body presents reasonably standardized dimensions with wellestablished chemical composition. Generally, these favorable conditions are not found in large industrial objects. In the industry there is much interest in using the information of the tomograph in order to know the interior of: (i) manufactured industrial objects or (ii) machines and their means of production. In these cases, the purpose of the tomograph is to: (a) control the quality of the final product and (b) optimize production, contributing to the pilot phase of the projects and analyzing the quality of the means of production. In different industrial processes, e. g. in chemical reactors and distillation columns, the phenomena related to multiphase processes are usually fast, requiring high temporal resolution of the computed tomography (CT) data acquisition. In this context, Instant non-scanning tomograph and fifth generation tomograph meets these requirements. An instant nonscanning tomography system is being developed at the IPEN/CNEN. In this work, in order to optimize the system, this tomograph comprised different collimators was simulated, with Monte Carlo method using the MCNP4C. The image quality was evaluated with Matlab® 2013b, by analysis of the following parameters: contrast to noise (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to analyze which collimator fits better to the instant nonscanning tomography. It was simulated three situations; (i) with no collimator; (ii) ?25 mm x 50 mm cylindrical collimator with a septum of ø5.0 mm x 50 mm; (iii) ø25mm x 50 mm cylindrical collimator with a slit septum of 24 mm x 5.0 mm x 50 mm.

    Palavras-Chave: collimators; computerized tomography; image processing; monte carlo method; quality assurance; quality management; shielding; signal-to-noise ratio; spatial resolution

  • IPEN-DOC 24054

    MAZER, AMANDA C. ; NAKANDAKARI, MARCOS V.N.; YORIYAZ, HELIO . Study of a 3D dosimetry system response – ARCCHECK®. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: Ionizing radiation therapies have improved over the years, becoming more specific for each patient. Thereby as the treatment planning system (TPS) complexities increases, the quality assurance (QA) methods have to be in a constant evolution. One of the techniques that demand great complexity is the Volumetric Modulated Arc Therapy (VMAT). One possible way to VMAT commissioning is using 3D dosimetry systems and recently a new 3D dosimetry system called ArcCheck had been developed and commercialized mainly for VMAT quality assurance. It is water-equivalent and composed by an array of 1386 diodes arranged in a spiral pattern. Since simulation methods, like Monte Carlo method, ensure highly accurate results, MCNP (A General Monte Carlo N-Particle Transport Code System) is totally reliable for problems that involve radiation transport. This work presents a preliminary study of the 3D dosimetry system ArcCheck by developing two computational models in MCNP6. In addition, experimental measures were acquired using the ArcCheck in a Linear Accelerator and then these values were compared with the results obtained by simulations of both models. The comparisons showed good reproducibility.

    Palavras-Chave: computerized simulation; f codes; linear accelerators; monte carlo method; planning; quality assurance; quality management; radiation doses; radiotherapy; three-dimensional calculations

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.