  • IPEN-DOC 17278

    COELHO, TALITA S.; FERNANDES, MARCO A.R.; YORIYAZ, HELIO ; LOUZADA, MARIO J.Q.. Analise dosimétrica de perfis de distribuições radiais de doses relativas de um aplicador de betaterapia de sup(90)Sr+sup(90)Y utilizando o código MCNP-4C e filmes radiocrônicos. Revista Brasileira de Fisica Medica, v. 4, n. 3, p. 7-10, 2011.

    Palavras-Chave: beta dosimetry; dose equivalents; dosimetry; films; m codes; measuring methods; radiation detection; radiation dose distributions; radiation dose units; radiation doses; radiation monitoring; radiation protection; radiations; strontium; strontium 90; yttrium; yttrium 90

  • IPEN-DOC 26248

    KOIKE, AMANDA C.R. ; ARAUJO, ELIAS S.; ALMEIDA-MURADIAN, LIGIA B.; VILLAVICENCIO, ANNA L.C.H. . Analysis of carotenoids in edible flowers of Dianthus chinensis processed by ionizing radiation. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2007-2014.

    Abstract: Over the last few years, the trend of using flowers in gastronomy, edible flowers are used in food preparations in order to add beauty, color and flavor. On the other hand, several species have active biologically substances, which play an important role in health maintenance. These highly perishable food should be grown without the use of pesticides. Thus, several methods are applied to increase the shelf life of food products, as well as ensure their quality and safety. Among the treatments, the food irradiation process has proven to be an effective tool in preserving and extending the shelf life of perishable product. Dianthus chinensis flowers, popularly known as Chinese pink (cravina), belongs to the family Caryophyllaceae, are native to Asia and Europe, are widely used in culinary preparations, being also acknowledged for their bioactive components and antioxidant properties. The purpose of this study was to evaluate carotenoids in D. chinensis flowers submitted to gamma irradiation and electron beam doses of 0.5, 0.8 and 1.0 kGy. High performance liquid chromatography was used to carotenoids determination. In the specie of edible flowers analyzed it was found carotenoid lutein (2.77 to x 7.52 mg/ 100 g). In general, the lutein was higher for irradiated samples, especially those treated with 0.8 and 1.0 kGy independently of irradiation technology. Accordingly, the applied irradiation treatments seemed to represent a feasible technology to preserve the quality of edible flower petals.

    Palavras-Chave: carotenoids; electron beams; flowers; gamma radiation; high-performance liquid chromatography; irradiation; radiation dose units; statistical data

  • IPEN-DOC 24420

    KUAHARA, L.T. ; CORREA, E.L. ; POTIENS, M.P.A. . Análise da variação da atividade de uma amostra de 99mTc após diluição com soro fisiológico. Brazilian Journal of Radiation Sciences, v. 05, n. 03-A, p. 01-10, 2017.

    Abstract: O ativímetro é um equipamento essencial em um serviço de medicina nuclear. Garantir seu bom funcionamento e conhecer os fatores que podem influenciar na sua leitura é fundamental para que a atividade administrada ao paciente esteja correta. Vários fatores podem causar alterações na resposta do ativímetro, como o tipo de recipi- ente, geometria e volume do radioisótopo. O objetivo deste trabalho foi analisar as variações nas medições de 0,5 mL e 1,0 mL de 99mTc puro e diluído em até 2,5 mL de soro fisiológico, em recipientes utilizados em medicina nuclear. Foram encontradas variações de até 4 % nos valores medidos.

    Palavras-Chave: activity meters; metering; nuclear medicine; quality control; radiation dose units; radiation protection; technetium 99; variations; variations

  • IPEN-DOC 25954

    SILVA, EVELIN C.da . Análise do perfil de expressão proteica da linhagem celular humana de adenocarcinoma renal, 786-O, submetida à radiação ionizante / Protein expression profile analysis of renal carcinoma cell, 786-0, submitted to ionizing irradiation . 2018. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 52 p. Orientador: Maria Helena Bellini Marumo. DOI: 10.11606/D.85.2019.tde-10092019-115524

    Abstract: O carcinoma de células renais (CCR) representa 3% das neoplasias humanas e aproximadamente 90% das neoplasias renais e entre os tumores urológicos. O CCR é bastante resistente à radioterapia convencional. Entretanto, com o aparecimento de novas técnicas/equipamentos é possivel a aplicação de doses com precisão presevando-se os tecidos adjacentes. Para a verificação da expressão proteica em diferentes tecidos e fluidos corporais, foi utilizado o estudo proteômico sob diferentes condições e / ou tempos. A espectrometria de massa permite a identificação e quantificação de milhares de proteínas e peptídeos em fluidos biológicos ou células lisadas, sendo assim uma ferramenta poderosa para identificação de potenciais biomarcadores de doenças. A finalidade deste trabalho foi analisar o perfil proteico das células de adenocarcinoma renal (786-0) após a radiação com doses que variaram de 2 a 10 Gy. Os dados foram tratados com o programa One-way ANOVA seguida do de Bonferroni. Pelo ensaio de clonogenicidade definiou-se a dose de 8 Gy como a ideal estudos. A extração das proteínas citoplasmáticas foi realizada com o kit de extração do proteoma subcelular PE e a quantificação das proteínas feita pelo método de Lowry. A integridade das proteínas foi analisada por SDS-PAGE e a solução proteica foi verificada em LTQ Orbitrap. Os resultados gerados foram analisados pelo servidor MASCOT para a busca de peptídeos. A análise por espectrometria de massa foi possível identificar 44 proteínas nas amostras não irradiadas - e 87 das amostras irradiadas. Nas amostras não irradiadas a distribuição dos grupos funcionais foi de síntese proteica 46,66%; Metabolismo energético 16,66%; Migração e proliferação 16,66%; Antioxidantes 3,33%. No grupo irradiado síntese proteica 35,89%; Metabolismo energético 20,51%; Migração e proliferação 20,51%; Antioxidantes 5,12%; Chaperonas moleculares 5,12% e Endopeptidases 5,12%. Em seguida, analisou-se o espetro de as sequências com escores acima de 40. Nas amostras irradiadas encontrou-se: ENO1 (47 kDa); A VIM (53 kDa)/ HEL113; PSMA1; TRAJ56; hCG; Cofilina-1 (19 kDa); HIST1H4H; PKM2; ANXA1; HSPB1/ HSP27. Deste grupo, entendemos que a subunidade alfa do proteassoma - tipo 1 (PSMA1), que possui uma atividade molecular de endopeptidase, seja um alvo interessante para estudos posteriores.

    Palavras-Chave: carcinomas; neoplasms; kidneys; urogenital system diseases; gene recombination proteins; animal cells; cell cultures; ionizing radiations; mass spectroscopy; radiation dose units; biological radiation effects

  • IPEN-DOC 26249

    ALBANO, ANDRESSA M.S. ; ARTHUR, VALTER. Application of gamma radiation in PEA (Pisum sativum L.) in natura to inhibit sprouting and increase shelf life. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2015-2029.

    Abstract: The irradiation of fresh post-harvest foods has as main interests: inhibit sprouting, increase shelf life, reduce or delay damage caused by insects and diseases. This work is a preliminary study on the use of gamma radiation in fresh peas grains (Pisum sativum L.) in order to evaluate its effects on the inhibition of sprout and its increase in shelf life. The peas were submitted to 4 treatments: 0 (control), 0.15, 0.30 and 0.45 kGy, in a 60Co research irradiator, after irradiation stored at 8 °C, being evaluated at 1, 7, 14 and 21 days after irradiation, for the following analyzes: assessments of visual appearance, total soluble solids, titratable total acidity, ratio, fresh weight loss, coloring, texture, pH, water content and ash. By visual evaluation it was observed that the irradiation did not significantly change the shelf life of the grains. The visual appearance, coloring and pH had interference due to the natural process of grain maturation. The doses of gamma radiation did not influence the content of ash, water and texture during storage and that dose of 0.45 kGy was not sufficient to inhibit the sprouting of the peas. It is possible to conclude that, with this work, a recommendation that, for the later works, in which one wishes to define the shelf life or to inhibit sprouting pea, initiate the irradiation of its samples with values above 0.45 kGy.

    Palavras-Chave: cobalt 60; food; gamma radiation; peas; radiation dose units; radiation effects; sprout inhibition; storage life

  • IPEN-DOC 27886

    ALBANO, A.M.S. ; ARTHUR, V. . Application of gamma radiation in pea (Pisum sativum L.) in nature to inhibit sprouting and increase shelf life. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-20, 2021. DOI: 10.15392/bjrs.v9i1A.1439

    Abstract: The irradiation of fresh post-harvest foods has as main interests: inhibit sprouting, increase shelf life, reduce or delay damage caused by insects and diseases. This work is a preliminary study on the use of gamma radiation in fresh peas grains (Pisum sativum L.) in order to evaluate its effects on the inhibition of sprout and its increase in shelf life. The peas were submitted at irradiation process with four radiation doses: 0 (control), 0.15, 0.30 and 0.45 kGy, in a 60Co research irradiator, with a dose rate of 0.323 kGy/h. After irradiation the samples were stored at 8 °C, being evaluated at 1, 7, 14 and 21 days by analyzes of: visual aspect, weight loss, color, hardness, pH, total soluble solids, total titratable acidity, ratio SST/TTA, water content and ash. By the results it was observed that in all parameters analyzes with gamma radiation doses used did not affect significantly in the shelf life of grains. The 0.30 kGy dose increased the germination of the peas and the 0.45 kGy dose was not sufficient to inhibit the sprouting of the peas.

    Palavras-Chave: chemical analysis; cobalt 60; food processing; gamma radiation; peas; radiation dose units; radiation effects; sprout inhibition; storage life

  • IPEN-DOC 19881

    TARDELLI, TIAGO C. . Avaliação de dados nucleares para dosimetria de nêutrons / Evaluation of nuclear data for neutron dosimetry . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 157 p. Orientador: Helio Yoriyaz. DOI: 10.11606/D.85.2013.tde-20012014-140902

    Abstract: Doses absorvidas e doses efetivas podem ser calculadas utilizando códigos computacionais de transporte de radiação. A qualidade desses cálculos depende dos dados nucleares, no entanto, são raras as informações sobre as diferenças nas doses causadas por diferentes bibliotecas. O objetivo desse estudo é comparar os valores de dose (absorvida e efetiva) obtidos utilizando diferentes bibliotecas de dados nucleares devido a uma fonte externa de nêutrons na faixa de 10-11 a 20 MeV. As bibliotecas de dados nucleares são: JENDL 4.0, JEFF 3.1.1 e ENDF/B-VII.0. Cálculos de doses foram realizados utilizando o código MCNPX considerando o modelo antropomórfico da ICRP-110. As diferenças nos valores das doses absorvidas utilizando as bibliotecas JEFF 3.1.1 e a ENDF/B.VII são pequenas, em torno de 1%, porém os resultados obtidos com a JENDL 4.0 apresentam diferenças de até 85 % compara aos resultados da ENDF/B-VII.0 e JEFF 3.1.1. Diferenças nas doses efetivas são em torno de 1,5% entre ENDF/B-VII.0 e JEFF 3.1.1, e 11 % entre ENDF/B-VII.0 e JENDL 4.0.

    Palavras-Chave: neutron transport; neutron emission; neutron sources; neutron flux; neutron dosimetry; interactions; measuring instruments; radiation dose units; nuclear energy; data analysis; computer codes; monte carlo method

  • IPEN-DOC 22963

    SOLE, STEPHANIE V. del ; BORRELY, SUELI I. . Avaliação de toxicidade e remoção da cor de efluente têxtil antes e após a irradiação com feixe de elétrons. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA; SEMINARIO ANUAL PIBIC, 22.; SEMINARIO ANUAL PROBIC, 13.; SEMINARIO ANUAL PIBITI, 6., 07-08 de dezembro, 2016, São Paulo, SP. Resumo expandido... São Paulo, SP: IPEN, 2016. p. 239-240.

    Palavras-Chave: textile industry; waste water; environmental impacts; waste processing; water use; ionizing radiations; toxicity; radiation dose units; electron beams

  • IPEN-DOC 19696

    VELOSO, MARCELO N. . Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica / In vitro evaluation of ionizing radiation effects in bone tissue by FTIR spectroscopy and dynamic mechanical analysis . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 74 p. Orientador: Denise Maria Zezell. DOI: 10.11606/D.85.2013.tde-10012014-111938

    Abstract: A radiação ionizante de fontes de radiação gama ou geradores de raios-x é frequentemente utilizada na ciência médica, como em exames de radiodiagnóstico, radioterapia e esterilização de aloenxertos. A radiação ionizante é capaz de quebrar cadeias polipeptidicas e provocar a libertação de radicais livres, pela radiólise de moléculas de água. A radiação ionizante interage também com o material orgânico a nível molecular, podendo alterar as suas propriedades mecânicas. No caso específico do tecido ósseo, estudos reportam que a radiação ionizante induz alterações nas moléculas de colágeno e reduzem a densidade de ligações cruzadas intermoleculares. O objetivo deste estudo foi verificar as alterações promovidas por diferentes doses de radiação ionizante no tecido ósseo utilizando a técnica de Espectroscopia Transformada de Fourier com Reflexão Total Atenuada (ATR-FTIR), e também a análise dinâmico-mecânica. Amostras de osso bovino foram irradiadas usando irradiador de Cobalto-60, com cinco doses diferentes: 0,01 kGy, 0,1 kGy, 1 kGy, 15 kGy e 75 kGy. Para estudar os efeitos da radiação ionizante sobre a estrutura química do osso foram avaliadas a relação material orgânico por material inorgânico, a relação de sub-bandas de amida I e o índice de cristalinidade. As alterações mecânicas foram determinadas por meio do módulo de elasticidade e do valor do amortecimento. Para verificar se as mudanças químicas e as características mecânicas de osso possuem alguma relação, realizou-se um estudo sobre a correlação entre as análises feitas com os dados espectroscópicos e as análises mecânicas. Foi possível avaliar os efeitos de diferentes doses de radiação ionizante no tecido ósseo. Com a análise por espectroscopia ATR-FTIR, foi possível observar as modificações dos componentes orgânicos e na organização cristais de hidroxiapatita. Também foram observadas alterações no módulo elástico e na tangente de delta (dissipação de energia mecânica). Foram encontradas altas correlações com significância estatística entre a relação das bandas (amida III + colágeno)/v1,v3, PO43- com a tangente de delta, e entre a relação 1/FHMW e o módulo elástico.

    Palavras-Chave: dosimetry; radiation dose distributions; radiation dose units; measuring instruments; animal tissues; bone tissues; fourier transform spectrometers; infrared spectra; dynamic loads; mechanical tests; ionizing radiations; in vitro

  • IPEN-DOC 19699

    GROPPO, DANIELA P. . Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 86 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2013.tde-03122013-144414

    Abstract: No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia.

    Palavras-Chave: dosimetry; thermoluminescent dosimetry; thermoluminescent dosemeters; luminescent dosemeters; alpha beams; electron beams; beta spectra; beryllium oxides; dose rates; radiation dose distributions; radiation dose units; measuring methods; comparative evaluations; nuclear medicine

  • IPEN-DOC 27822

    SARTORI, GISELLE P.; COSTA, ANDREA da; MACARINI, FERNANDO L. dos S.; MARIANO, DOUGLAS O.C.; PIMENTA, DANIEL C.; SPENCER, PATRICK J. ; NALI, LUIZ H. da S.; GALISTEO JUNIOR, ANDRES J.. Characterization and evaluation of the enzymatic activity of tetanus toxin submitted to cobalt-60 gamma radiation. Journal of Venomous Animals and Toxins including Tropical Diseases, v. 27, p. 1-13, 2021. DOI: 10.1590/1678-9199-JVATITD-2020-0140

    Abstract: Background Tetanus toxin blocks the release of the inhibitory neurotransmitters in the central nervous system and causes tetanus and its main form of prevention is through vaccination. The vaccine is produced by inactivation of tetanus toxin with formaldehyde, which may cause side effects. An alternative way is the use of ionizing radiation for inactivation of the toxin and also to improve the potential immunogenic response and to reduce the post-vaccination side effects. Therefore, the aim of this study was to characterize the tetanus toxin structure after different doses of ionizing radiation of 60Co. Methods Irradiated and native tetanus toxin was characterized by SDS PAGE in reducing and non-reducing conditions and MALD-TOF. Enzymatic activity was measured by FRET substrate. Also, antigenic properties were assessed by ELISA and Western Blot data. Results Characterization analysis revealed gradual modification on the tetanus toxin structure according to doses increase. Also, fragmentation and possible aggregations of the protein fragments were observed in higher doses. In the analysis of peptide preservation by enzymatic digestion and mass spectrometry, there was a slight modification in the identification up to the dose of 4 kGy. At subsequent doses, peptide identification was minimal. The analysis of the enzymatic activity by fluorescence showed 35 % attenuation in the activity even at higher doses. In the antigenic evaluation, anti-tetanus toxin antibodies were detected against the irradiated toxins at the different doses, with a gradual decrease as the dose increased, but remaining at satisfactory levels. Conclusion Ionizing radiation promoted structural changes in the tetanus toxin such as fragmentation and/or aggregation and attenuation of enzymatic activity as the dose increased, but antigenic recognition of the toxin remained at good levels indicating its possible use as an immunogen. However, studies of enzymatic activity of tetanus toxin irradiated with doses above 8 kGy should be further analyzed.

    Palavras-Chave: cobalt 60; detoxification; enzyme activity; gamma radiation; irradiation; neurology; radiation dose units; tetanus; toxins; vaccines

  • IPEN-DOC 26265

    SARTORI, GISELLE P.; COSTA, ANDREA; MACARINI, FERNANDA L.S.; MARIANO, DOUGLAS O.C.; PIMENTA, DANIEL C.; SPENCER, PATRICK J. ; GALISTEO JUNIOR, ANDRES J.. Characterization and evaluation of the enzymatic activity of tetanus toxin submitted to gamma radiation by Cobalt 60. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2191-2203.

    Abstract: Tetanus is a neurological disease which blocks the inhibitory neurotransmitters liberation. Also treatment does not cure the disease, and its main form of prevention is through vaccination. The vaccine is produced by the inactivation of tetanic toxin (TeNT) with formaldehyde, which may cause side effects. An alternative way is the use of ionizing radiation for inactivation of the toxin and also to improve the potential immunogenic response and to reduce the pos-vaccination side effects. Therefore, the aim of this study was to characterize the TeNT structure after different doses of ionizing radiation of Cobalt 60, and also to assess the enzymatic activity after the radiation. SDS PAGE and MALDI-TOF analysis revealed gradual modification on the TeNT structure according to doses increase. Also, fragmentation and possible aggregations of the protein fragments were observed in higher doses. In the analysis of peptide preservation by enzymatic digestion and mass spectrometry, there was a slight modification in the recognition up to the dose of 4 kGy at subsequent doses, recognition was minimal. The analysis of the enzymatic activity by fluorescence showed a 35 % attenuation in the activity even at higher doses. In the antigenic evaluation performed by ELISA and Western Blot, anti-TeNT antibodies were detected against the irradiated toxins at the different doses, with a gradual decrease as the dose increased, but remaining at satisfactory levels, indicating the possibility of possible use as an immunogen, however, studies of enzymatic activity on higher should be further analyzed.

    Palavras-Chave: cobalt 60; detoxification; enzyme activity; gamma radiation; irradiation; neurology; radiation dose units; tetanus; toxins; vaccines

  • IPEN-DOC 25705

    CAMARGO, F.; GONCALVES, J.A.C. ; BUENO, C.C. . A comparison between rad-hard float zone silicon diodes as gamma dosimeter in radiation processing. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-13, 2019. DOI: 10.15392/bjrs.v7i2A.681

    Abstract: In this work, we report on the results obtained with rad-hard Standard Float Zone (STFZ) and Diffused Oxygenated Float Zone (DOFZ) silicon diodes in radiation processing dosimetry. The dosimetric probes were designed to operate in the direct current mode, as on-line radiation dosimeter. The irradiation of the samples was performed using a 60Co source with a dose rate of almost 2.4 kGy/h. The current response of each diode was measured as a function of the exposure time in steps from 5 kGy up to 50 kGy to achieve a total absorbed dose of 275 kGy. In this dose range it is observed a significant decrease in the photocurrent generated in both devices due to gamma radiation defects produced in their active volumes. To mitigate this effect, the samples were pre-irradiated with 60Co gamma rays at 700 kGy. Despite of being less sensitive, these devices presented stable and reproducible current signals with a relative sensitivity decrease of about 19% within the whole range of dose studied. The dose-response curves of the pre-irradiated diodes showed quadratic behavior with correlation coefficient higher than 0.9999 for total absorbed dose up to 275 kGy. The comparison of the diodes’ dosimetric responses evidenced that the best result was achieved with the DOFZ, which exhibited slightly higher sensitivity and stability than the STFZ devices. However, it is important to note that all pre-irradiated diodes can be used as gamma dosimeters in radiation processing applications.

    Palavras-Chave: gamma dosimetry; gamma radiation; absorbed radiation doses; comparative evaluations; zone melting; cobalt 60; silicon diodes; radiation dose units; irradiation; dose rates; oxygen; radiation dose ranges

  • IPEN-DOC 24139

    CAMARGO, FABIO de; GONÇALVES, JOSEMARY A.C. ; BUENO, CARMEN C. . A comparison between rad-hard float zone silicon diodes as gamma dosimeter in radiation processing. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: In this work, we report on the results obtained with rad-hard Standard Float Zone (STFZ) and Diffused Oxygenated Float Zone (DOFZ) silicon diodes in radiation processing dosimetry. The dosimetric probes were designed to operate in the direct current mode, as on-line radiation dosimeter. The irradiation of the samples was performed using a 60Co source with a dose rate of almost 2.4 kGy/h. The current response of each diode was measured as a function of the exposure time in steps from 5 kGy up to 50 kGy to achieve a total absorbed dose of 275 kGy. In this dose range it is observed a significant decrease in the photocurrent generated in both devices due to gamma radiation defects produced in their active volumes. To mitigate this effect, the samples were pre-irradiated with 60Co gamma rays at 700 kGy. Despite of being less sensitive, these devices presented stable and reproducible current signals with a relative sensitivity decrease of about 19% within the whole range of dose studied. The dose-response curves of the pre-irradiated diodes showed quadratic behavior with correlation coefficient higher than 0.9999 for total absorbed dose up to 275 kGy. The comparison of the FZ and DOFZ responses evidenced that the latter was slightly superior to the first. However, it is important to note that all pre-irradiated diodes can be used as gamma dosimeters in radiation processing applications.

    Palavras-Chave: absorbed radiation doses; cobalt 60; comparative evaluations; dose rates; gamma dosimetry; oxygen; radiation dose ranges; radiation dose units; silicon diodes; zone melting

  • IPEN-DOC 19876

    GERULIS, EDUARDO . Controle de dose em transporte rodoviário de material radioativo / Dose control in road transport of radioactive material . 2013. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 63 p. Orientador: Gian Maria Agostino Angelo Sordi. DOI: 10.11606/T.85.2013.tde-16012014-110059

    Abstract: As doses de radiação ionizante para os trabalhadores no transporte de material radioativo devem ser tão pequenas quanto razoavelmente exequível. As doses médias dos motoristas e carregadores amostrados neste trabalho devem ser diminuídas. A demonstração do controle das doses em veículo rodoviário com material radioativo, requisitada pelo regulamento brasileiro atual, norma CNEN NE 5.01, é apresentada em formulário próprio com valores de exposição obtidos em posições de ocupação regular de indivíduos do público e de trabalhadores, mesmo quando se expede veículo sem a necessidade de uso exclusivo (∑ IT 50). Este trabalho mostra, por meio de pesquisa bibliográfica, elaboração de modelos e pesquisa de campo, que esta demonstração do controle com a obtenção dos valores de exposição nesta situação, para um método de controle melhor, deve ser realizada pela apresentação do registro do acúmulo de cargas, limitado (∑ IT 50), a fim de evitar a obtenção destas medidas, para que haja padronização com regulamentos estrangeiros e para que os custos e os tempos, importantes para expedição de radiofármacos com meia-vida curta, e também as atuais doses laborais dos técnicos de radioproteção sejam todos diminuídos. Os valores de exposição dos parâmetros utilizados com esse método são menores do que seus limites regulamentares. Para contribuir com essas finalidades devem ser apresentadas pelo regulamento brasileiro atualizado as distâncias de segregação entre as cargas e as cabines dos veículos.

    Palavras-Chave: radiation protection; dosimetry; radiation detection; radiation dose units; dose rates; occupational exposure; radiation transport; road transport; transport regulations; standardization; brazil

  • IPEN-DOC 28012

    GROPPO, DANIELA P. . Correlação de parâmetros físicos e dosimétricos de diferentes detectores utilizados em dosimetria de campos pequenos para radioterapia em um acelerador linear clínico / Correlation of physical and dosimetric parameters of different detectors used in small field dosimetry for radiotherapy in a clinical linear accelerator . 2020. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 135 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/T.85.2020.tde-16062021-145616

    Abstract: Atualmente, as doses administradas em procedimentos radiocirúrgicos são extremamente elevadas, quando comparadas a outros procedimentos radioterápicos. A acurácia dosimétrica para esses tipos de tratamentos requer um comissionamento de campos pequenos de radiação a serem parametrizados em um sistema de planejamento computadorizado. A medição dosimétrica (relativa e direta) de campos pequenos representa um desafio, pois pode introduzir erros na entrega de dose; assim, alguns parâmetros dosimétricos (perfil de dose e porcentagem de dose na profundidade) da interação da radiação com a matéria podem ser comprometidos como o equilíbrio de partículas carregadas. Para melhor mensurar esses dados dosimétricos, alguns detectores são empregados. Mesmo com o uso destes detectores específicos, faz-se necessário identificar e avaliar as incertezas que podem provir do efeito do tamanho do volume e do arranjo experimental do detector sob o campo de radiação. Neste trabalho, as medições dosimétricas foram obtidas com filmes radiocrômicos (medição de referência), câmaras de ionização de volume sensível pequeno, diodos e detectore de diamante. Para correlacionar os parâmetros físicos e dosimétricos obtidos com os detectores, foram utilizados formalismos matemáticos. Esses formalismos matemáticos propostos mostraram-se eficazes quando aplicados à dosimetria de campos pequenos circulares em aceleradores lineares clínicos da fabricante Elekta, modelo Versa HD®, com feixes de fótons (6 MV), com e sem o uso do filtro aplainador (flattening filter).

    Palavras-Chave: linear accelerators; rilac; linac-ring accelerators; quadrupole linacs; radiation detectors; small angle scattering; fractionated irradiation; surgical materials; filters; gamma sources; ionization chambers; dose rates; radiation doses distributions; radiation dose units; measuring methods; phantoms; pmma; computer-aided manufacturing; data covariances; three-dimensional calculations; mathematical solutions; clinical trials; dosimetry; radiotherapy; nuclear medicine

  • IPEN-DOC 21825

    SECCO, MARCELLO . Desenvolvimento de dispositivo movimentador automatizado de amostras com vista à aplicação em medidas de radioisótopos que possuem curto tempo de meia-vida / Development of controller of acquisition and sample positioner for activation for use in measurements of short half-life radioisotopes . 2016. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 118 p. Orientador: Frederico Antonio Genezini. DOI: 10.11606/D.85.2016.tde-06062016-085324

    Abstract: Medidas de espectroscopia gama de alta resolução têm diversas aplicações. Aplicações envolvendo medidas de radioisótopos de meia-vida curta podem apresentar problemas de baixa precisão nas contagens quando a fonte radioativa está distante do detector e de perda de acurácia por efeitos de tempo morto e empilhamento de pulsos em situação de altas taxas de contagens. Um modo de minimizar esses problemas é alterando a posição da fonte radioativa durante o processo de medição, aproximando-a do detector conforme sua atividade diminui e assim maximizando o número de contagens medidas. Neste trabalho, foi desenvolvido o Movimentador de Amostras Radioativas Automatizado (MARA), um aparato de baixo custo, feito com materiais de baixo número atômico e leve, projetado e construído para auxiliar nas medidas de espectroscopia gama, capaz de controlar a distância entre a fonte e o detector, permitindo inclusive que ocorra alteração dessa distância durante o processo de medição. Por ser automatizado ele otimiza o tempo do operador, que tem total liberdade para criar suas rotinas de medidas no dispositivo, além de evitar que o mesmo tome uma parcela da dose radioativa. Foi também feita uma interface que permite controle do MARA e a programação do sistema de aquisição de dados. Foram realizados testes para otimização da operação do sistema MARA e foi verificada a segurança de operação do MARA, não apresentando nenhuma falha durante seus testes. Foi aplicado o teste de repetitividade, por meio de medições com uma fonte calibrada de 60Co, e verificou-se que o sistema de movimentação de prateleiras automatizado reproduziu os resultados do sistema estático com confiabilidade de 95%.

    Palavras-Chave: nanoseconds living radioisotopes; half-life; radiation dose distributions; radiation dose ranges; radiation dose units; frequency measurement; data acquisition systems; gamma spectroscopy; cobalt 60 target; safety standards; control systems; resource development; automation; semiconductor detectors; decay

  • IPEN-DOC 21736

    TIEZZI, RODRIGO . Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em medicina nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicine . 2016. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 66 p. Orientador: Maria Elisa Chuery Martins Rostelato. DOI: 10.11606/D.85.2016.tde-07032016-140958

    Abstract: As fontes radioativas seladas são usadas na verificação de detectores de câmara de ionização, os quais medem a atividade dos radioisótopos usados nas mais diversas áreas, como na Medicina Nuclear. A medida da atividade dos radioisótopos deve ser feita com exatidão, pois será administrada em um paciente. Para garantir o adequado funcionamento dos detectores de câmara de ionização, são estipulados ensaios normatizados pela Agência Internacional de Energia Atômica (IAEA) e a Comissão Nacional de Energia Nuclear (CNEN) utilizando-se fontes radioativas seladas de Bário-133, Césio-137 e Cobalto-57. Os testes avaliam a exatidão, precisão, reprodutibilidade e linearidade da resposta do equipamento. O foco deste trabalho foi o estudo e o desenvolvimento dessas fontes radioativas padrão de Bário-133, Césio-137 e Cobalto-57, utilizando um polímero, no caso resina epóxi comerciais do tipo éter diglicidílico do bisfenol A e um agente de cura a base de poliamina modificada da dietilenotriamina ,para imobilizar o material radioativo. A matriz polimérica apresenta a função primordial de fixar e imobilizar o conteúdo radioativo não permitindo seu vazamento dentro dos limites técnicos exigidos pelas normas de proteção radiológica no quesito de características de uma fonte selada e, adicionalmente, ter a capacidade de reter a emanação de quaisquer gases que venham a se formar durante o processo de fabricação e do período de vida útil deste artefato. O processo de manufatura de uma fonte selada padrão consiste no envasamento, em um frasco de geometria padronizada, de uma quantidade, em volume fixo, de uma matriz polimérica no interior da qual é adicionada e dispersada homogeneamente uma quantidade precisa e exata em atividade de um material radioativo padrão. Nesse sentido, realizou-se um estudo para a escolha da resina epóxi, analisando suas características e propriedades. Foram realizados estudos e testes, verificando a máxima miscibilidade da resina com a água (solução ácida, simulando as condições da solução radiativa), perdas de propriedades mecânicas e térmicas, bem como o controle de dose radioativa para a completa cura (irradiadores de cobalto).Foram produzidas fontes de césio-137 e bário-133, realizou-se testes para determinação do grau de homogeneidade na dispersão do material radioativo na matriz e testes de imersão das fontes seladas produzidas para verificar a estanqueidade do sistema desenvolvido, obtendo um resultado satisfatório de acordo com as normas. Analisando todos os resultados obtidos, as fontes seladas podem ser confeccionadas em matriz epóxi DGEBA e endurecedor poliamínico DETA modificado, desde que a quantidade de material radioativo, na forma de solução ácida, adicionado à composição não ultrapasse um teor de 20%. A cura da resina epóxi pode ser melhorada em relação a ambiente, com uso da irradiação desde que seja exposta a uma dose ao redor de 33 kGy durante a cura. Nos testes de estanqueidade, verificou-se que as fontes são estanques, as medições da atividade da água utilizada nos testes mostraram um valor inferior a 185 Bq (de acordo com a International Standard Organization- Radiation protection sealed radioactive sources - ISO 9978), comprovando a eficiência da resina epóxi como material para selar o material radioativo. Tendo a finalidade de criar uma tecnologia nacional capaz de suprir a demanda deste produto no mercado interno e atingir excelência em qualidade através da acreditação e certificação do produto junto aos órgãos competentes.

    Palavras-Chave: nuclear medicine; diagnosis; ionization chambers; sealed sources; resins; polymerization; standard model; barium 133; cesium 137; cobalt 57; mechanical properties; thermodynamic properties; radiation dose units; radiation monitoring; comparative evaluations; radiation detectors

  • IPEN-DOC 19220

    SOUZA, DAIANE C.B. de . Desenvolvimento de método para caracterização de embalados de rejeitos radioativos / Development of a method for the radioisotopic characterization of waste packages . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 87 p. Orientador: Ademar Roberto Vicente. DOI: 10.11606/D.85.2013.tde-24102013-150643

    Abstract: Atualmente, a caracterização dos resíduos radioativos gerados na operação do reator nuclear de pesquisas IEA-R1 está em curso. O reator IEA-R1 é um reator do tipo piscina aberta, moderado e refrigerado por água leve, utilizando dois leitos de resinas de troca iônica e de carvão ativado para purificação de água de refrigeração. Estes meios filtrantes são substituídos quando já não são capazes de manter a qualidade da água dentro dos limites exigidos e são tratados como rejeitos radioativos. Contendo produtos de fissão, ativação e actinídeos que escapam do núcleo do reator para a água da piscina, apresentam altas taxas de dose devido à quantidade de emissores gama de meias-vidas curtas e intermediárias, emissores alfa, elementos transurânicos de meia-vida longa bem como emissores beta puros. A caracterização destes rejeitos, consequentemente, requer métodos de análise radioquímica que incluem a amostragem e o processamento das amostras, resultando em doses elevadas para os trabalhadores. Nesse contexto, o objetivo deste trabalho consistiu em correlacionar os resultados das análises radioquímicas de amostras de rejeitos, com os resultados das medições radiométricas, utilizando a modelagem das taxas de dose em diferentes distâncias da superfície dos embalados. As taxas de dose medidas foram comparadas com os resultados de cálculos . Massa, volume e geometria das fases sólidas e líquidas de cada um dos tambores também foram determinadas, uma vez que o teor de água varia amplamente entre diferentes tambores, e são essenciais para estimar as atividades totais em cada tambor.

    Palavras-Chave: radioisotopes; cobalt 60; cesium 137; radioactive waste management; radioactive waste disposal; packaging; dose rates; radiation dose distributions; radiation dose units; measuring instruments; kerma; meters; occupational exposure; shields; design; programming; computer codes; administrative procedures

  • IPEN-DOC 19877

    FERREIRA, DANILO C. . Desenvolvimento e calibração de um sistema dosimétrico de rotina em processamento por irradiação / Development and calibration of a routine dosimetry system for radiation processing . 2013. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 129 p. Orientador: Carmen Cecilia Bueno. DOI: 10.11606/T.85.2013.tde-19122013-161529

    Abstract: O desenvolvimento e calibração de um sistema dosimétrico de rotina baseado no fotodiodo comercial e de baixo custo (SFH 206) é apresentado neste trabalho. A sonda dosimétrica foi projetada para operar sem tensão de polarização no modo de corrente direta. As radiações foram realizadas no irradiador Panorâmico de Cobalto-60 no intervalo de taxas de dose de 8,1 Gy/h a 125 Gy/h. As fotocorrentes geradas no diodo, para cada taxa de dose, foram registradas utilizando um eletrômetro digital e foram armazenadas durante todo o tempo de exposição. A resposta em corrente do diodo foi medida em função do tempo de exposição em intervalos de 1 Gy até 200 Gy para doses acumuladas de até 15 kGy. Neste intervalo, a resposta em dose do diodo, em função da carga gerada pela dose, foi linear com coeficiente de correlação melhor que 0,998. Estes resultados foram comparados com os obtidos com filmes Gafchromic frequentemente utilizados em dosimetria de rotina. Para monitorar possíveis danos de radiação gama produzidos no diodo, as sensibilidades em corrente e em carga foram medidas em função da dose absorvida. Para doses até 15 kGy, não foi observado qualquer dano de radiação o que confirma a boa reprodutibilidade de resposta do diodo, melhor do que 3 %. Finalmente, devido aos pequenos erros experimentais ( 5% ) e boa resolução espacial do diodo, foi possível medir a dose de trânsito devida ao movimento da fonte radioativa de Cobalto-60 bem como a distribuição da taxa de dose no Irradiador Panorâmico.

    Palavras-Chave: radiation protection; dosimetry; dosemeters; semiconductor diodes; measuring instruments; calibration; radiation detection; radiation dose units; dose rates; cobalt 60; gamma radiation

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.