  • IPEN-DOC 25751

    CUNHA, J.S.; SANTOS, W.S. ; CARVALHO JUNIOR, A.B.. Conversion Coefficients of equivalent and effective doses in terms of air kerma for computational scenarios of Total Body Irradiation in lying-down patients. Radiation Physics and Chemistry, v. 159, p. 138-146, 2019. DOI: 10.1016/j.radphyschem.2019.02.051

    Abstract: This study aimed to calculate the Conversion Coefficients (CC) of Equivalent and Effective doses by air kerma considering Total Body Irradiation scenarios with Varian linear accelerator with photon beams energy of 4, 6, 10, 15, 18, and 25 MV. The simulations were performed in the MCNPX code and the University of Florida (UF) phantoms were used to represent exposed lying down adult patients in the AP, PA, RLAT, and LLAT irradiation geometries. Lead attenuators were inserted in the scenarios for the preservation of organs of risk and their contribution were analyzed for CC. For most counts, the statistical uncertainty was approximately 5%. For the gonads, CC values for the male phantom decreased with the increase of energy in the AP geometry, which did not occur for the female phantom. As the beam becomes more penetrating, the ovary absorbs more energy because of its internal position. Considering the lung, an organ of risk in TBI, the insertion of the attenuators in the scenarios caused the CC values to reduce by more than 30%. For organs and tissues such as skin and male breasts, the attenuators caused the dose to increase. As for the active bone marrow, which is the TBI target tissue, it was not possible to obtain a good estimate for CC at 15, 18, and 25 MV due to a limitation of the method used to calculate the dose in the bone areas. Nevertheless, for lower energies the CC values for the marrow were valid.

    Palavras-Chave: conversion; equivalent dose range; kerma; whole-body irradiation; patients; ionizing radiations; dose equivalents; phantoms

  • IPEN-DOC 15396

    FRIMAIO, A.; COSTA, P.R.; VANDERLINDE, F.V.F.; CAMPOS, L.L. . Desenvolvimento de materiais ceramicos para utilizacao em protecao radiologica diagnostica. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 11., 14-17 de junho, 2006, Ribeirao Preto, SP. Resumo... 2006.

    Palavras-Chave: attenuation; barite; barium sulfates; barium; ceramics; computerized simulation; density; experimental data; kerma; lead; optimization; qualitative chemical analysis; quantitative chemical analysis; radiation protection; shielding materials; shielding; thickness; x radiation

  • IPEN-DOC 19220

    SOUZA, DAIANE C.B. de . Desenvolvimento de método para caracterização de embalados de rejeitos radioativos / Development of a method for the radioisotopic characterization of waste packages . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 87 p. Orientador: Ademar Roberto Vicente. DOI: 10.11606/D.85.2013.tde-24102013-150643

    Abstract: Atualmente, a caracterização dos resíduos radioativos gerados na operação do reator nuclear de pesquisas IEA-R1 está em curso. O reator IEA-R1 é um reator do tipo piscina aberta, moderado e refrigerado por água leve, utilizando dois leitos de resinas de troca iônica e de carvão ativado para purificação de água de refrigeração. Estes meios filtrantes são substituídos quando já não são capazes de manter a qualidade da água dentro dos limites exigidos e são tratados como rejeitos radioativos. Contendo produtos de fissão, ativação e actinídeos que escapam do núcleo do reator para a água da piscina, apresentam altas taxas de dose devido à quantidade de emissores gama de meias-vidas curtas e intermediárias, emissores alfa, elementos transurânicos de meia-vida longa bem como emissores beta puros. A caracterização destes rejeitos, consequentemente, requer métodos de análise radioquímica que incluem a amostragem e o processamento das amostras, resultando em doses elevadas para os trabalhadores. Nesse contexto, o objetivo deste trabalho consistiu em correlacionar os resultados das análises radioquímicas de amostras de rejeitos, com os resultados das medições radiométricas, utilizando a modelagem das taxas de dose em diferentes distâncias da superfície dos embalados. As taxas de dose medidas foram comparadas com os resultados de cálculos . Massa, volume e geometria das fases sólidas e líquidas de cada um dos tambores também foram determinadas, uma vez que o teor de água varia amplamente entre diferentes tambores, e são essenciais para estimar as atividades totais em cada tambor.

    Palavras-Chave: radioisotopes; cobalt 60; cesium 137; radioactive waste management; radioactive waste disposal; packaging; dose rates; radiation dose distributions; radiation dose units; measuring instruments; kerma; meters; occupational exposure; shields; design; programming; computer codes; administrative procedures

  • IPEN-DOC 11345

    FRIMAIO, AUDREW . Desenvolvimento de um material cerâmico para utilização em proteção radiológica diagnóstica. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Leticia Lucente Campos Rodrigues. DOI: 10.11606/D.85.2006.tde-04062007-163758

    Abstract: Este estudo tem por objetivo formular um composto cerâmico para revestimento de paredes visando contribuir para a otimização da blindagem de salas de diagnóstico. O trabalho foi baseado em medidas experimentais de atenuação da radiação X (80 e 100 kV) empregando materiais cerâmicos de revestimento contendo diferentes suportes cerâmicos (vermelho, branco, grês, porcelanatos, etc). Dentre os suportes cerâmicos avaliados, o grês branco apresentou melhores propriedades atenuadoras, e foi considerado o mais adequado para a proposta deste trabalho. Diferentes formulações de grês branco foram estudadas e alteradas a fim de obter melhores propriedades atenuadoras. Foram efetuadas simulações de composições cerâmicas de revestimento grês dentro das porcentagens de matérias-primas necessárias na composição que são 12-20% argila; 6-18% caulim; 12-25% filito; 8-14% quartzo; 10-18% feldspato; 32- 40% pegmatito; 6-8% talco. As composições químicas quantitativas e qualitativas destes materiais foram também avaliadas, e os elementos constituintes mais comuns são SiO2, Fe2O3, Al2O3, CaO e Ti2O3. Considerando que o CaO pode ser substituído pelo PbO ou BaO, foram estudadas formulações com maiores teores de óxidos de Pb e Ba. O comportamento destes materiais como atenuadores para a radiação X foi investigado por meio de simulações computacionais que levaram em consideração os espectros de raios X incidentes e transmitidos através das diferentes composições estudadas e comparado com os materiais de referência Pb, Ba e BaSO4 (barita). Os resultados obtidos nas simulações indicaram as formulações do composto de suporte cerâmico grês que demonstram melhores propriedades de atenuação levando-se em conta as energias usadas em raios X diagnóstico (80, 100 e 150 kV). Placas cerâmicas baseadas na composição formulada que apresentou menor diferença percentual em relação ao Pb foram produzidas em laboratório e testadas fisicamente como revestimento de parede e barreira protetora. Propriedades como módulo de resistência à flexão, densidade, carga de ruptura, absorção de água e atenuação da radiação X foram avaliadas para todas as placas produzidas.

    Palavras-Chave: attenuation; barite; barium sulfates; barium; ceramics; computerized simulation; density; experimental data; kerma; lead; optimization; qualitative chemical analysis; quantitative chemical analysis; radiation protection; shielding materials; shielding; thickness; x radiation

  • IPEN-DOC 23343

    SANTOS, LUCAS R. dos . Desenvolvimento de um protocolo de calibração utilizando espectrometria e simulação matemática, em feixes padrões de raios x / Development of a calibration protocol using spectrometry and mathematical simulation, in x ray standard beams . 2017. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 113 p. Orientador: Maria da Penha Albuquerque Potiens. DOI: 10.11606/T.85.2017.tde-11082017-090607

    Abstract: A calibração, por definição, é o processo pelo qual se estabelece uma relação entre valores de medição de um padrão, com as suas respectivas incertezas, e as indicações com as incertezas associadas do instrumento de medição a ser calibrado. Um protocolo de calibração descreve a metodologia a ser aplicada em um processo de calibração. O método escolhido para a obtenção deste protocolo foi o da espectrometria de feixe de raios X associada à simulação pelo método de Monte Carlo, fundamentado no fato de que ambos são considerados métodos absolutos na determinação de parâmetros de feixes de radiação. Neste trabalho foi utilizado o método de Monte Carlo utilizado para obter a função resposta do detector utilizada para a correção dos espectros obtidos do feixe primário de radiação X; deste modo foram calculadas as taxas de kerma destes feixes e comparadas aos valores obtidos com as câmaras de ionização padrão secundário do Laboratório de Calibração de Instrumentos do IPEN (LCI/IPEN). Foram obtidos os coeficientes de calibração para o sistema padrão com diferenças em relação ao fornecido pelo laboratório primário entre 1,3% e 15,3%. Os resultados obtidos indicaram a viabilidade do estabelecimento deste protocolo de calibração utilizando a espectrometria como padrão de referência, com incertezas relativas de 0,62% para k=1. As incertezas associadas ao método proposto foram satisfatórias, para um laboratório padrão secundário e comparáveis a um laboratório primário.

    Palavras-Chave: inspection; calibration; calibration standards; interlaboratory comparisons; measuring instruments; data covariances; radiation metrology; radiation doses; radiation dose rate ranges; kerma; semiconductor detectors; ionization chambers; x-ray spectrometers; x radiation; beam monitors; response functions; computer calculations; computer codes; monte carlo method; comparative evaluations

  • IPEN-DOC 21704

    DAMATTO, WILLIAN B. . Desenvolvimento de uma metodologia de avaliação de medidores portáteis de radiação em altas taxas de kerma no ar / Development of a methodology of portable radiation meters at high rates of air . 2015. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 67 p. Orientador: Vitor Vivolo. DOI: 10.11606/D.85.2016.tde-17022016-145001

    Abstract: Uma série de testes foi aplicada a medidores portáteis de radiação ionizante para altas taxas de kerma no ar, especificamente medidores do tipo teletector. Estes detectores são do tipo Geiger Müller e são utilizados em rotinas de proteção radiológica em aceleradores, reatores, fontes de alta atividade e ainda em situações de emergência no Brasil, assim como em outros países. Também são encaminhados para calibração no Instituto de Pesquisa Energéticas e Nucleares (IPEN) e foram analisados para estabelecer parâmetros de comportamento destes detectores, especificando as suas sensibilidades e suas características operacionais. Foram realizados testes de variação da leitura dos equipamentos com a tensão da bateria, efeito de geotropismo, dependência energética, dependência angular. Com este testes foi possível determinar as características mais comuns e importantes destes equipamentos permitindo a elaboração de um programa de controle de qualidade. Foram calibrados 17 teletectors durante este trabalho e destes, 10 foram testados. Os testes foram realizados para caracterizar o sis tema gama de irradiação (dosimetria de feixe de radiação) que possui maior atividade e permite testes em medidores do tipo teletectors em uma maior faixa de medição. Desse modo foi feito o aperfeiçoamento do programa de controle de qualidade de medidores portáteis de radiação ionizante para altas taxas de kerma no ar no LCI, oque beneficiou os usuários deste tipo de equipamento, e ainda com medições e calibrações mais consistentes e com melhor controle de qualidade dos processos.

    Palavras-Chave: dosemeters; testing; geiger-mueller counters; measuring instruments; ionization; kerma; radiation doses; gamma dosimetry; dosimetry

  • IPEN-DOC 19118

    COSTA, NATHALIA A. . Desenvolvimento de uma metodologia de calibração e testes de medidores de produto Kerma-Área / Development of a calibration methodology and tests of kerma area product meters . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 73 p. Orientador: Maria da Penha Albuquerque Potiens. DOI: 10.11606/D.85.2013.tde-14082013-144903

    Abstract: A grandeza produto kerma-área (PKA) é importante para estabelecer níveis de referência em exames de radiologia diagnóstica. Essa grandeza pode ser obtida por meio de medidores do PKA. O uso desses medidores é fundamental para avaliar a dose de radiação em procedimentos radiológicos, além de ser um bom indicador para que os limites de dose na pele do paciente não sejam excedidos. Algumas vezes, esses medidores vêm acoplados a equipamentos de radiação X, o que dificulta sua calibração. Neste trabalho foi desenvolvida uma metodologia de calibração de medidores do PKA. O instrumento utilizado para este fim foi o Patient Dose Calibrator (PDC). Ele foi desenvolvido para ser utilizado como referência na verificação da calibração de medidores do PKA e kerma no ar usados na dosimetria de pacientes e para verificação da consistência e do comportamento de sistemas de controle de exposição automáticos. Por se tratar de um equipamento novo, que, no Brasil, ainda não é utilizado como equipamento de referência para calibração, foi realizado, também o controle de qualidade deste equipamento, com testes de caracterização, a calibração e a avaliação da dependência energética. Após os testes, ficou provado que o PDC pode ser utilizado como instrumento de referência para a calibração a ser realizada in situ, de forma que as características de cada equipamento de radiação X onde os medidores do PKA são utilizados sejam consideradas. A calibração foi, então, realizada com medidores do PKA portáteis e em um equipamento de radiologia intervencionista que possui um medidor do PKA acoplado. Os resultados foram bons e ficou provada a necessidade de calibração desses medidores e a importância da calibração in situ com um medidor de referência.

    Palavras-Chave: diagnostic techniques; radiology; calibration; kerma; meters; radiation doses; dosemeters; patients

  • IPEN-DOC 22369

    MARTINS, ELAINE W. ; POTIENS, MARIA da P.A. . Design and development of a pediatric phantom. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 9th, July 6-11, 2014, Valencia, Espanha. Proceedings... 2014.

    Palavras-Chave: design; construction; phantoms; surface air; kerma; comparative evaluations; patients; children; patients; children

  • IPEN-DOC 04674

    NOGUEIRA, MARIA do S.. Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios X gerados no intervalo de 50 kV subp a 125 kV subp. 1997. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 118 p. Orientador: Leticia Lucente Campos Rodrigues.

    Palavras-Chave: dose equivalents; kerma; pmma; phantoms; radiation doses; personnel dosimetry; x-ray spectra; lead; shielding; radiology; radiation protection; calibration; radiation detectors; measuring instruments; diagnosis

  • IPEN-DOC 27083

    MARTINS, E.W. ; CARDOSO, J.V.; POTIENS, M.P.A. . Determination of computed tomography quantities using a new pediatric phantom. In: INTERNATIONAL CONFERENCE ON RADIATION PROTECTION IN MEDICINE: ACHIEVING CHANGE IN PRACTICE, December 11-15, 2017, Vienna, Austria. Proceedings... Vienna, Austria: International Atomic Energy Agency, 2018. p. 1-5.

    Abstract: A computed tomography pediatric head phantom that uses special materials to simulate the cortical and the cancellous bone was developed. This paper shows its behavior to determine the specific computed tomography radiation quantities at two calibration laboratory, the LCI-IPEN, Brazil and LMRI-IST, Portugal. The specific quantities measured were: air kerma index(Ca,100), weighted air kerma index (Cw), average volumetric air kerma index (Cvol) and the air kerma- lenght product (PKL). The reference radiation qualities used in both laboratories were the radiation qualities recommended by the norm IEC 61267 (RQT8, RQT9 e RQT10) to computed tomography dosimetry measurements. The calculated values of CW show attenuation of 11%, 13% and 10% for the qualities RQT 8, RQT 9 and RQT 10, respectively, from cortical to cancellous bone.

    Palavras-Chave: phantoms; pediatrics; computerized tomography; kerma

  • IPEN-DOC 07321

    NOGUEIRA, M.S.; CAMPOS, L.L. ; MOTA, H.C.. Determination of conversion coefficients between air kerma or photon fluence and ambient dose equivalent for diagnostic X ray beams. Radiation Protection Dosimetry, v. 81, n. 2, p. 123-132, 1999.

    Palavras-Chave: kerma; photons; dose equivalents; diagnostic uses; x-ray sources; radiation quality; pmma; phantoms; ionization chambers; thermoluminescent dosemeters; shielding; radiation protection

  • IPEN-DOC 18539

    MARTINS, ELAINE W.; POTIENS, MARIA da P.A. . Determination of specific CT quantities in standard beams using phantoms. In: SYMPOSIUM ON RADIATION MEASUREMENTS AND APPLICATIONS, May 14-17, 2012, Oakland, USA. Proceedings... 2012.

    Palavras-Chave: computerized tomography; dosimetry; calibration; ionization chambers; phantoms; kerma; radiation doses

  • IPEN-DOC 21239

    BARREIRA, J.S.; VIVOLO, V. . Determination of the tube voltage from clinic mammographic system using two type of detectors. Brazilian Journal of Radiation Sciences, v. 3, n. 1A, p. 1-6, 2015. DOI: 10.15392/bjrs.v3i1A.175

    Palavras-Chave: tomography; mammary glands; x radiation; dosemeters; radiation protection; quality control; electric potential; kerma; molybdenum; rhodium

  • IPEN-DOC 20424

    BARREIRA, J.S.; VIVOLO, V. . Determination of the tube voltage from clinic mammographic system using two types of detectors. In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4., August 26-29, 2014, Gramado, RS. Proceedings... 2014.

    Palavras-Chave: diagnostic techniques; mammary glands; neoplasms; calibration; air; kerma; electric currents; x-ray tubes; radiation doses; radiation detectors; radiation quality

  • IPEN-DOC 20265

    PERINI, ANA P. ; NEVES, LUCIO P. ; CALDAS, LINDA V.E. . Development and characterization of a graphite-walled ionization chamber as a reference dosimeter for sup(60)Co beams. Radiation Physics and Chemistry, v. 104, p. 248-251, 2014.

    Palavras-Chave: brazilian cnen; calibration standards; cobalt 60; dosemeters; dosimetry; experimental data; graphite; ionization chambers; kerma; monte carlo method

  • IPEN-DOC 21238

    NEVES, L.P.; PETRINI, A.P.; SANTOS, W.S. ; CALDAS, L.V.E. . Development and characterization of a new graphite ionization chamber for dosimetry of sup(60(Co) beams. Brazilian Journal of Radiation Sciences, v. 3, n. 1A, p. 1-10, 2015.

    Palavras-Chave: brazilian cnen; ionization chambers; cobalt 60; dosimetry; dosemeters; monte carlo method; calibration standards; kerma; experimental data; graphite

  • IPEN-DOC 22370

    COSTA, N. ; POTIENS, M. . Development of a calibration methodology and tests of kerma area product meters. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 9th, July 6-11, 2014, Valencia, Espanha. Proceedings... 2014.

    Palavras-Chave: calibration; diagnosis; dosemeters; kerma; meters; patients; quality control; radiation doses; radiology

  • IPEN-DOC 18554

    COSTA, N.A.; POTIENS, M.P.A. . Development of a calibration methodology of the patient dose calibrator. In: INTERNATIONAL CONFERENCE ON RADIATION IN MEDICINE, December 3-7, 2012, Bonn, Germany. Proceedings... 2012.

    Palavras-Chave: diagnostic techniques; radiology; calibration; kerma; meters; radiation doses; dosemeters; patients

  • IPEN-DOC 18542

    COSTA, NATHALIA A.; POTIENS, MARIA da P.A. . Development of a quality control program of the patient dose calibrator. In: CONGRESSO BRASILEIRO DE FÍSICA MEDICA, 17., 8-11 de agosto, 2012, Salvador, BA. Anais... 2012.

    Palavras-Chave: diagnostic techniques; x radiation; radiation doses; patients; kerma; calibration; quality control; performance

  • IPEN-DOC 26132

    PRIMO, CAMILA de O. ; ANGELOCCI, LUCAS V. ; KARAM JUNIOR, DIB; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Dose-rate constant and air-kerma strength evaluation of a new 125-I brachytherapy source using Monte-Carlo. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 167-174.

    Abstract: Brachytherapy is a modality of radiotherapy which treats tumors using ionizing radiation with sources located close to the tumor. The sources can be produced from several radionuclides in various formats, such as Iodine-125 seeds and Iridium-192 wires. In order to produce a new Iodine-125 seed in IPEN/CNEN and ensure its quality, it is essential to describe the dosimetry of the seed, so when applied in a treatment the lowest possible dose to neighboring healthy tissues can be reached. The report by the AAPM’s Task Group 43 U1 is a document that indicates the dosimetry procedures in brachytherapy based on physical and geometrical parameters. In this study, dose-rate constant and air-kerma strength parameters were simulated using the Monte Carlo method radiation transport code MCNP4C. The air-kerma strength is obtained from an ideal modeled seed, since its actual value should be measured for seeds individually in a specialized lab with a Wide-Angle Free-Air Chamber (WAFAC). Dose-rate constant and air-kerma strength are parameters that depends on intrinsic characteristics of the source, i.e. geometry, radionuclide, encapsulation, and together they define the dose-rate to the reference point, defined as the dose-rate to a point 1 cm away from the geometric center of the source, in its transverse plane. This study presents the values found for these parameters with associated statistical uncertainty, and is part of a larger project that aims the full dosimetry of this new seed model, including experimental measures.

    Palavras-Chave: brachytherapy; computerized simulation; dose rates; dosimetry; iodine 125; kerma; monte carlo method

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.