  • IPEN-DOC 10701

    MIRANDA, J.A.; POTIENS, M.P.A. . Avaliacao dos valores de taxa de kerma no ar dos sistemas de radiacao X utilizados na calibracao de intrumentos de medida em radiodiagnostico. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: air; calibration standards; calibration; ionization chambers; kerma; quality assurance; radiation doses; radiation protection; radiation quality; x-ray equipment

  • IPEN-DOC 21712

    FONTES, LADVJANE P.; POTIENS, MARIA da P.A. . Avaliação da dependência energética de câmara de ionização do tipo lápis calibradas em feixes padrões de tomografia / Evaluation of the energy dependence of ionization chambers pencil type calibrated beam tomography standards. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 2 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: ionization chambers; calibration standards; dosimetry; computerized tomography; energy dependence; evaluation; quality assurance; measuring methods

  • IPEN-DOC 19952

    LEAL, ALEXANDRE S.; MELO, FERNANDA P.S.; GOMES, TATIANA C.B.; SANTANA, AMALIA S.; CUNHA, LUZIA H. da; SAIKI, MITIKO . Avaliação da qualidade da sinvastatina comercializadas por farmácias de manipulação em Belo Horizonte/MG / Assessment of the quality of the simvastatin commercialized by pharmacies of manipulation from the city of Belo Horizonte/Brazil. Vigilância Sanitária em Debate: Sociedade, Ciência & Tecnologia, v. 2, n. 1, p. 69-74, 2014.

    Palavras-Chave: brazil; quality control; manipulators; quality assurance; drugs; cholesterol

  • IPEN-DOC 24622

    FURUKAWA, CÁSSIA Y. . Avaliação de alguns fatores interferentes na estabilidade radioquímica de alguns radiofármacos marcados com 99mTc / Evaluation of some interfering factors on the radiochemical stability of some radiopharmaceuticals labeled Technetium-99m . 2016. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 99 p. Orientador: Margareth Mie Nakamura Matsuda. DOI: 10.11606/D.85.2018.tde-09022018-083115

    Abstract: Os radiofármacos são fármacos que possuem em sua composição um radionuclídeo e são utilizados para diagnóstico e tratamento de diversas doenças na medicina nuclear. O principal objetivo desse trabalho foi avaliar o efeito da temperatura e umidade na estabilidade de alguns reagentes liofilizados ALBUMINA-TEC, CIS-TEC, DEX-500-TEC, DEX-70-TEC, DISI-TEC, DMSA-TEC, DTPA-TEC, FITA-TEC, PUL-TEC, MIBI-TEC, MDP-TEC, PIRO-TEC, e TIN-TEC. Foi utilizada uma câmara climática para expor amostras destes produtos a uma temperatura de 40 °C e 75% de umidade relativa por 48 horas, para simular uma condição de transporte. Foram avaliadas duas situações: após um determinado tempo de armazenamento em temperatura de 2 - 8 °C, amostras de RL foram expostas por 48 horas em 40 °C e 75% UR e em seguida foram analisadas enquanto outras amostras foram colocadas por 48 horas em 40 °C e 75% UR, mantidas em temperatura de 2 - 8 °C até a validade do radiofármaco e analisadas quanto à pureza radioquímica e biodistribuição. Os radiofármacos ALBUMINA-TEC, DEX-70-TEC, DEX-500-TEC, DISI-TEC, DMSA-TEC, DTPA-TEC, PIRO-TEC, MDP-TEC, MIBI-TEC e MDP-TEC apresentaram resultados de % PRq e biodistribuição que atenderam às especificações, enquanto que CIS-TEC, PUL-TEC e TIN-TEC apresentaram alguns valores de % PRq menor que o especificado. TIN-TEC apresentou % PRq de 84% em um de três lotes, enquanto PUL-TEC apresentou % PRq de 88% em um de quatro lotes analisados; CIS-TEC é um RL que ainda precisa melhor analisado pois os resultados fora do especificado no controle radioquímico e biológico foram obtidos com um produto fora da validade especificada. Estes resultados indicaram que a pureza radioquímica pode ser afetada pela condição de estudo, o que não foi confirmado pelo controle biológico.

    Palavras-Chave: radiopharmaceuticals; technetium 99; radioimmunoassay; radioimmunodetection; scintiscanning; tracer techniques; stability; quality assurance; certification; inspection; radiation protection; regulations; safety standards

  • IPEN-DOC 20524

    SILVA, ERIC A.B. da; PAVANI, RAFAEL S.; SILVA, THALITA G. da; VIVOLO, VITOR ; DAROS, KELLEN A.C.; POTIENS, MARIA P.A. . Avaliação dos erros encontrados em radiografia realizada pelos estudantes do curso de graduação em odontologia na UNINOVE. In: INTERNATIONAL JOINT CONFERENCE - RADIO 2014, August 26-29, 2014, Gramado, RS. Proceedings... 2014.

    Palavras-Chave: dentistry; educational facilities; learning; biomedical radiography; errors; risk assessment; quality assurance; evaluation

  • IPEN-DOC 24977

    SMITH, RICARDO B. . Bases de projeto para a automatização do sistema de garantia da qualidade em gerência de rejeitos radioativos / Project bases for the automation of a quality assurance system in radioactive waste management . 2018. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 160 p. Orientador: Roberto Vicente. DOI: 10.11606/D.85.2018.tde-29062018-144015

    Abstract: O projeto, operação e descomissionamento de uma unidade de tratamento e armazenamento de rejeitos requerem que sejam observados os requisitos regulatórios referentes à garantia da qualidade nuclear, conforme o Regulamento CNENNN1.16 "Garantia da Qualidade para a Segurança de Usinas Nucleoelétricas e Outras Instalações", da Comissão Nacional de Energia Nuclear (CNEN). Entretanto, embora a aplicação do regulamento seja obrigatória, o documento da CNEN apresenta requisitos para qualquer tipo de instalação nuclear, sendo por isso genérico e pouco detalhado em relação às ações necessárias para garantir que os requisitos mais específicos de uma unidade de tratamento e armazenamento de rejeitos sejam observados. Além disso, não existem comercialmente ferramentas informatizadas já prontas para utilização, mas somente programas para gestão de qualidade que requerem uma adaptação através da inclusão de conjuntos de dados específicos do programa de controle da qualidade de uma instalação de gestão de rejeitos, ou então o desenvolvimento de uma ferramenta personalizada. Desta forma, o objetivo deste trabalho é buscar informações que permitam o desenvolvimento de bases para um sistema informatizado de garantia da qualidade que esteja em conformidade com o regulamento da CNEN NN-1.16, e que possa vir a englobar os procedimentos específicos para uma instalação de tratamento e gestão de rejeitos radioativos.

    Palavras-Chave: radioactive waste management; quality assurance; computerized control systems; programming; nuclear facilities; nuclear power plants; reporting requirements; regulations; standardization

  • IPEN-DOC 20563

    CASTRO, LILIANA ; MOREIRA, EDSON G. ; MAIHARA, VERA A. ; VASCONCELLOS, MARINA B.A. . Bovine kidney reference material preparation proposal to be used in quality assurance of chemical measurements in meat products. In: INTERNATIONAL NUCLEAR CHEMISTRY CONGRESS, 4th, September 14-19, 2014, Maresias, SP. Abstract... 2014. p. 149.

    Palavras-Chave: brazil; cattle; meat; kidneys; calibration standards; quality assurance; multi-element analysis; neutron activation analysis; absorption spectroscopy

  • IPEN-DOC 11767

    DELGADO, JUAN F.; VIEIRA, ANDRE M.M.; CRUZ, JOSE C.; RODRIGUES, LAURA N. . Calculo independente de dose para tratamentos de arco dinamico com colimador micromultilaminas. Radiologia Brasileira, v. 39, n. 5, p. p. 355-359, 2006.

    Palavras-Chave: radiotherapy; quality assurance; surgery; linear accelerators; collimators

  • IPEN-DOC 14287

    PEREIRA, RAQUEL M.; ARAUJO, ELAINE B. de . Certificacao em boas praticas de fabricacao das linhas de producao de radiofarmacos no IPEN-CNEN/SP. In: SEMINARIO ANUAL DO PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIACAO CIENTIFICA, 15.; SEMINARIO ANUAL DO PROGRAMA DE BOLSAS E INICIACAO CIENTIFICA, 6., 7-8 de outubro, 2009, Sao Paulo, SP. Resumo expandido... 2009. p. 159-160.

    Palavras-Chave: brazilian cnen; radiopharmaceuticals; radioisotope generators; isotope production; certification; quality assurance

  • IPEN-DOC 10711

    PAIVA, R.P. ; SALVETTI, T.C. . Certificacao NBR ISO 9001 para as atividades realizadas no reator nuclear IEA-R1. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: audits; brazilian cnen; certification; iear-1 reactor; management; quality assurance; reactor operation; standards

  • IPEN-DOC 12087

    TICIANELLI, REGINA B. ; FIGUEIREDO, ANA M.G. . Certification of biological reference materials: participation of the neutron activation laboratory (LAN-IPEN/CNEN-SP). In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: biological materials; calibration standards; certification; elements; experimental data; flour; interlaboratory comparisons; neutron activation analysis; quality assurance; trace amounts

  • IPEN-DOC 19463

    CARVALHO, DIEGO V. de S.; KIRITA, RODRIGO; MESQUITA, CARLOS H. de ; FERREIRA, ERIC O.; DANTAS, CARLOS C.; HAMADA, MARGARIDA M. . Collimation effects on the radiation detectors in the ICT image quality. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: industrial radiography; computerized tomography; collimators; radiation doses; measuring methods; images; quality assurance

  • IPEN-PUB-365

    VIEIRA JUNIOR, N.D. . Como conciliar pesquisa tecnologica com pesquisa fundamental. 1992. 21 p.

    Palavras-Chave: brazilian organizations; research programs; information; technology transfer; personnel; education; productivity; quality assurance

  • IPEN-DOC 15706

    YOSHIZUMI, MAIRA T.; CALDAS, LINDA V.E. . Comparative study of the response stability of monitor ionization chambers in X-radiation beams. Radioproteção, v. 2, n. 16-17, p. 42-47, 2010.

    Palavras-Chave: alara; dosimetry; experimental data; international organizations; ionization chambers; legislation; public health; quality assurance; quality control; radiation detection; radiation doses; radiation protection; recommendations

  • IPEN-DOC 16460

    CECILIO, P.J.; CRUZ, J. da; RODRIGUES, L. ; SANTOS, A.; MARTINS, L.; CAPRIOGLIO, L.. Comparison of two ionization chamber used absolute dose for intensity modulated radiotherapy of prostate quality assurance. Radiotherapy and Oncology, v. 76, Suppl. 2, p. S185, 2005.

    Palavras-Chave: prostate; neoplasms; radiotherapy; ionization chambers; radiation doses; phantoms; quality assurance

  • IPEN-DOC 25969

    MAZER, A.C. ; NAKANDAKARI, M.V.N.; RIBEIRO, V.A.B.; SIQUEIRA, P.T.D. ; SHORTO, J.M.B. ; YORIYAZ, H. . Computational model of a 3D dosimetry system - ArcCHECK®. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-11, 2019. DOI: 10.15392/bjrs.v7i2A.675

    Abstract: Ionizing radiation therapies have been improving over the years, becoming more specific for each patient. Thereby, as the treatment planning system (TPS) complexities increases, the quality assurance (QA) methods have to be in constant evolution. One of the techniques that demand great complexity is the Volumetric Modulated Arc Therapy (VMAT), and one possible way to VMAT commissioning is using 3D dosimetry systems. Recently a new 3D dosimetry system called ArcCHECK had been developed and commercialized mainly for VMAT quality assurance. It is water-equivalent and composed by an array of 1386 diodes arranged in a helical pattern. Since simulation methods, like Monte Carlo method, ensure highly accurate results, MCNP (A General Monte Carlo N-Particle Transport Code System) is totally reliable for problems that involve radiation transport. This work presents two computational models for Monte Carlo simulations to predict detection responses in the QA procedure using the ArcCHECK. The computational models were validated comparing the system responses obtained from MCNP6 simulations against measured responses due to a 6 MeV clinical photon beam from a Linear Accelerator. 2D dose maps were reported here with good agreement between simulated and measured values.

    Palavras-Chave: radiotherapy; dosimetry; quality assurance; mathematical models; monte carlo method; programming

  • IPEN-DOC 16468

    BUCHMANN, JOSE H.; SARKIS, JORGE E. de S. . O conceito da incerteza aplicado aos processos de medição associados à preparação de um solução de referência para calibração. Quimica Nova, v. 25, n. 1, p. 111-116, 2002.

    Palavras-Chave: uncertainty principle; quality assurance; calibration standards; uranium; solutions; chemical analysis; laboratories

  • IPEN-DOC 16233

    LIMA, JOSENILSON B. de; POTIENS JUNIOR, ADEMAR J. . Controle de qualidade das eficiencias dos detectores do laboratorio de caracterizacao de rejeitos radioativos. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 16.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 7., 2-21 de outubro, 2010, Sao Paulo, SP. Resumo expandido... 2010. p. 139-140.

    Palavras-Chave: materials testing; nuclear materials management; quality assurance; quality control; radioactive waste disposal; radioactive waste facilities; radioactive waste processing; radioactive wastes; reliability; safety; solid scintillation detectors

  • IPEN-PUB-237

    RZYSKI, B.M.. Controle de qualidade no gerenciamento de rejeitos radioativos. 1988. 37 p.

    Palavras-Chave: inspection; quality assurance; quality control; waste management

  • IPEN-DOC 26416

    LITVAC, DANIEL . Desenvolvimento de um kit postal dosimétrico para calibração de aplicadores clínicos de betaterapia no Brasil / Development of a dosimetric postal kit for calibration of clinical beta therapy applicators in Brazil . 2019. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 93 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2019.tde-21112019-165533

    Abstract: O sistema de saúde no Brasil, como um todo, possui déficits em mão de obra e em infraestrutura. A betaterapia é uma das alternativas que o Sistema Único de Saúde e serviços particulares implantam para suprir a demanda. Aplicadores clínicos de 90Sr/90Y são utilizados para tratamentos dermatológicos e oftálmicos, substituindo o uso de aceleradores lineares, porque são de custo mais baixo, mais práticos e possuem 28,8 anos de meia-vida. A calibração e a recalibração periódica destes aplicadores, para verificação da taxa de dose absorvida, são essenciais para garantir a segurança nos tratamentos clínicos. Trabalhos de pesquisas mostram discrepâncias entre a calibração do fabricante e a realizada em laboratórios, podendo ter consequências danosas para os pacientes. Além disso, são poucos os laboratórios de calibração do tipo padrão primário para fontes de radiação beta no mundo. Na América Latina não existem laboratórios de calibração com este perfil. Foi desenvolvido neste trabalho um kit postal dosimétrico que permitiu a recalibração dos aplicadores clínicos utilizados em hospitais, de maneira prática, rápida e com instruções, por meio de seu envio aos proprietários, e depois retornando ao IPEN para posterior avaliação. Para isto, alguns materiais dosimétricos foram caracterizados em feixes padronizados de radiação beta, utilizando as técnicas de termoluminescência e luminescência opticamente estimulada para comparação de resultados da resposta quanto à reprodutibilidade, linearidade, curva dose-resposta e dependência angular, definindo as condições mais adequadas e o grupo de dosímetros para calibração dos aplicadores clínicos.

    Palavras-Chave: radiotherapy; dosimetry; beta decay; radiation doses; dose-response relationships; quality control; quality assurance; testing; clinical trials; performance; uses; tissue distribution; skin; eyes; radiation metrology; calibration; brazil

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.