Navegação IPEN por Autores IPEN "COSTA, OSVALDO L. da"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 19956

    SOMESSARI, SAMIR L. ; FEHER, ANSELMO ; SPRENGER, FRANCISCO E. ; ROSTELATO, MARIA E.C.M. ; ZEITUNI, CARLOS A. ; MOURA, JOAO A.; COSTA, OSVALDO L. da ; CALVO, WILSON A.P. . Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy. Journal of Physical Science and Application, v. 3, n. 6, p. 380-386, 2013.

    Palavras-Chave: automation; brachytherapy; sealed sources; radiation source implants; laser welding; neodymium lasers; quality control; isotope production

  • IPEN-DOC 24133

    COSTA, OSVALDO L. da ; SOUZA, DAIANE C.B. de ; FEHER, ANSELMO ; MOURA, JOAO A. ; SOUZA, CARLA D. ; OLIVEIRA, HENRIQUE B. de ; PELEIAS JUNIOR, FERNANDO S. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Brazilian demand for iodine-125 seeds in cancer treatment after a decade of medical procedures. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Palavras-Chave: brachytherapy; brain; demand; iodine 125; ophthalmology; sealed sources; statistical data

  • IPEN-DOC 21233

    PELEIAS JUNIOR, FERNANDO dos S. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. ; FECHINE, GUILHERMINO J.M.; SOUZA, CARLA D. de ; MATTOS, FABIO R. de ; MOURA, EDUARDO S. de ; MOURA, JOAO A. ; BENEGA, MARCOS A.G. ; FEHER, ANSELMO ; COSTA, OSVALDO L. da ; RODRIGUES, BRUNA T. . Desenvolvimento da metodologia para sintese do poli-)acido latico-co-acido glicolico) para utilização na produção de fontes radioativas / Development of methodology for the synthesis of poly(lactic acid-co-glycolic acid) for use in the production of radioactive sources. Polimeros, v. 25, n. 3, p. 317-325, 2015.

    Palavras-Chave: brachytherapy; neoplasms; prostate; glycolic acid; seeds; synthesis; radiation sources; radioactivity; iodine 125; polymers; isotope production; lactic acid

  • IPEN-DOC 29113

    BARCELLOS, HENRIQUE ; MATSUDA, HYLTON ; LAPOLLI, ANDRE L. ; SUMIYA, LUIZ C. do A. ; JUNQUEIRA, FERNANDO de C. ; COSTA, OSVALDO L. da . Design and assembly of an XY-type beam current monitor for cyclotron accelerators. Applied Radiation and Isotopes, v. 192, p. 1-5, 2023. DOI: 10.1016/j.apradiso.2022.110550

    Abstract: A water-cooled XY-type beam current monitor was designed, manufactured and assembled in a cyclotron accelerator beam transport line. Tests were performed, demonstrating that apparatus is an instrument of great assistance in proton beam position. The XY-type beam current monitor has been widely used in liquid target irradiations, employing irradiation system which were originally designed for irradiations on 18 MeV cyclotron accelerator (Cyclone 18, IBA) only, however, with this apparatus, the target may be exchanged between the 30 MeV (Cyclone 30, IBA) and 18 MeV cyclotrons.

    Palavras-Chave: cyclotrons; beam monitors; beam analyzers; proton beams; targets

  • IPEN-DOC 26279

    CASTANHO, FABIO G. ; COSTA, OSVALDO L. da . Design and development of a device for the opening of irradiated aluminum capsules in the IPEN IEA-R1 nuclear reactor. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2388-2397.

    Abstract: The production of radionuclides in nuclear research reactors is an important activity of national nuclear energy programs. Numerous radionuclides produced include molybdenum-99, iodine-131 and phosphorus-32, widely used in medical procedures. Radionuclides are produced by exposing the target material to a neutron flux in one of the irradiation positions in the core of the nuclear reactor. Before irradiation, the target materials must be contained in sealed capsules, preventing the release of radionuclides that contaminate the nuclear reactor installation. The capsules used in the Nuclear and Energy Research Institute (IPEN) IEA-R1 nuclear reactor are made of aluminum, taking advantage of the following characteristics: low cross section for neutron absorption, radionuclide production from the aluminum alloy of short half-life, good thermal conductivity and possibility of cold sealing of the capsule. This work proposes a new device for opening irradiated aluminum capsules (rabbits), with implement of a better procedure, focusing on operator safety. Ensuring safety during all stages and processes is a preponderant factor when it comes to radioactive materials. The following main deficiencies are identified about the current opening procedure: a) radioactive debris generated by the cutting contaminate the environment of manipulation, increasing the risks of exposure to radiation and the care with the collect and disposal of these debris; b) rotation movement of the capsule during opening may cause damage to the target material and its casing, leading release of radioactive target materials. The new opening device: a) uses the least possible electronic components based on integrated semiconductor circuits, susceptible to radiation; b) contemplates that the insertion and removal of the capsules will be done by telemanipulators; c) modifies the type of cutting performed, from abrasive to cutting wheel blade, allowing minimal generation of small size radioactive debris; d) replaces the rotation of the capsule by a movement in the cutting head, keeping the capsule still, thus reducing the risk of damage to the samples; e) provides greater control, process accuracy and emergency stop, through improved remote operating system. Results of comparative tests showed that the current system produces average 0.3(2) mg of debris per cut, while the proposed system of cutting wheel blade presented a reduction of more than 99 % in the generation of debris. In addition, the immobilization of capsule during the open prevents damage to the radioactive target materials.

    Palavras-Chave: aluminium; capsules; design; fission products; hot cells; iear-1 reactor; openings

  • IPEN-DOC 21049

    TIEZZI, RODRIGO ; ROSTELATO, MARIA E.C.M. ; NAGATOMI, HELIO R. ; ZEITUNI, CARLOS A. ; BENEGA, MARCOS A. ; SOUZA, DAIANE B. de; COSTA, OSVALDO L. da ; SOUZA, CARLA D. ; RODRIGUES, BRUNA T. ; SOUZA, ANDERSON S. de ; PELEIAS JUNIOR, FERNANDO S. ; SANTOS, RAFAEL M. dos; MELO, EMERSON R. de; KARAN JUNIOR, DIB. Development of sealed radioactive sources immobilized in epoxy resin for verification of detectors used in nuclear medicine. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: sealed sources; epoxides; resins; radiation detectors; nuclear medicine; amines

  • IPEN-DOC 21199

    COSTA, OSVALDO L. da . Estudo e desenvolvimento de uma nova metodologia de produção de iodo-125 a partir de xenônio-124 pelo método de ativação neutrônica / Study and development of a new methodology for production of iodine-125 from xenon-124 through the method of neutron activation . 2015. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 157 p. Orientador: Maria Elisa Chuery Martins Rostelato. DOI: 10.11606/T.85.2015.tde-23102015-094126

    Abstract: Neste trabalho foi desenvolvida uma nova metodologia de produção de iodo-125, que resultou na primeira produção deste radionuclídeo no Brasil. Cápsulas de alumínio foram projetadas, fabricadas e avaliadas para que suportassem condições de pressão, temperatura e fluxo de nêutrons no reator nuclear IEA-R1 do IPEN sem a ocorrência de liberação de material radioativo. Foram projetados, desenvolvidos e fabricados sistemas de carregamento, descarregamento e recuperação dos gases para a manipulação do gás xenônio e do iodo. Foi desenvolvido um novo método de lavagem da cápsula, para dissolução do iodo-125 adsorvido nas paredes, por meio de imersão em banho ultrassônico. Foram irradiadas três cápsulas no reator nuclear IEA-R1, por um período de aproximadamente 60 h contínuas, a um fluxo de nêutrons de 5,5 x 1013 n cm-2 s-1. Foi produzido um total de 13,53 GBq (365,73 mCi) de iodo-125, e o único contaminante encontrado foi o radionuclídeo iodo-126. Na análise radioquímica, pelo método de cromatografia em papel ascendente, o iodo-125 em solução de NaOH apresentou percentual de iodeto acima de 98%, superior à exigência da farmacopeia americana para soluções de iodo radioativo que é de 95%. Para a análise radionuclídica foi desenvolvida uma fonte planar, a base de resina epoxídica, para a contagem do iodo-125 em detector de germânio de alta pureza. A correlação entre o iodo-125 e o iodo-126 produzido apresentou valores entre 0,5 e 0,7% após um período de decaimento de 10 d, grau de pureza suficiente para a utilização em técnicas de radioimunoensaio.

    Palavras-Chave: isotope production; iodine 125; iodine 126; xenon 124; irradiation capsules; aluminium; iear-1 reactor; neutron flux; high-purity ge detectors; radiochemistry; chromatography

  • IPEN-DOC 23884

    ROSTELATO, MARIA E.C.M. ; ZEITUNI, CARLOS A. ; MOURA, JOAO A. ; FEHER, ANSELMO ; COSTA, OSVALDO L. da ; MOURA, EDUARDO S. de ; SOUZA, CARLA D. de ; KARAM JUNIOR, DIB . Estudo, desenvolvimento e produção de fontes radioativas para radioterapia. In: ENCONTRO NACIONAL DE FÍSICA NA INDÚSTRIA, 1., 04-05 de abril, 2013, São Carlos, SP. Resumo... São Paulo: Sociedade Brasileira de Física, 2013. p. 44-44.

    Abstract: Desde 1997, o IPEN-CNEN/SP por meio do seu “Laboratório de Produção Fontes para Radioterapia - LPFR”, produz fontes radioativas de Irídio-192, na forma de fi os, e fornece aos hospitais para utilização em radioterapia de baixa taxa de dose (LDR). Está em fase de conclusão, a montagem de uma instalação para a produção de fontes radioativas de Iodo-125, na forma de sementes, para uso em tratamento de câncer de próstata, oftálmico e cerebral. Essa instalação consiste de três glove-box (uma caixa estanque). A primeira, semi-automatizada, é a reação do iodo radioativo com o núcleo de prata que forma a semente. É a parte do processo que apresenta maior risco, tendo diversos sistemas redundantes de segurança como duplo fi ltro, depressão de ar e proteção física. A segunda é a solda da cápsula de titânio que envolve esse núcleo. Essa parte é inteiramente automatizada e o controle visual da qualidade da solda é feito pelo operador através de um sistema de câmaras. A terceira fase é o controle de qualidade, totalmente automatizado, que garante a estanqueidade das sementes prontas de acordo com a norma ISO 9978 - “Sealed Radioactive Sources-Leak Test Methods”. Como fase extra a dosimetria da semente está em desenvolvimento. Ela engloba o estudo de diversos parâmetros que auxiliam no cálculo da dose exata que o paciente recebeu ao utilizar esse tratamento. O grupo espera a conclusão para 2014. Atualmente encontra-se em desenvolvimento e implementação um laboratório para produção de fontes de Irídio-192, na forma de “pellets”, para utilização em radioterapia de alta taxa de dose (HDR). Estas fontes são importadas acarretando altos custos para a sociedade. Estas fontes são usadas para tratar vários tipos de câncer. Por exemplo: colo de útero, mama, pulmão e outros. A produção local de fontes radioativas para radioterapia reduzirá sensivelmente seus custos, permitindo um aumento do número de pacientes tratados no país. A proteção implementada no caso do Irídio-192 é maior quando comparada com o iodo-125. O primeiro isótopo apresenta energia de emissão entre 0,137 a 0,65 MeV enquanto o segundo 0,03MeV. Por essa razão o irídio será manipulado em hot cell (célula quente) que são enormes estruturas totalmente revestidas de chumbo pesando aproximadamente 25 toneladas. O operador usará um telemanipulador e o sistema do ar será totalmente selado. O vidro para visualização contém chumbo na formulação. Como resultado o operador leva praticamente nenhuma dose de radiação. O grupo espera a conclusão do novo prédio em 2018.

  • IPEN-DOC 21123

    COSTA, OSVALDO L. da ; TIEZZI, RODRIGO ; SOUZA, DAIANE C.B.; FEHER, ANSELMO ; MOURA, JOAO A. ; SOUZA, CARLA D. ; MOURA, EDUARDO S. ; OLIVEIRA, HENRIQUE B. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Evaluation of aluminium capsules according to ISO 9978 to irradiation of gaseous samples in nuclear reactor. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: aluminium; capsules; iso; standardization; irradiation; mass spectroscopy; gases; helium; fabrication; leak testing; sealed sources

  • IPEN-DOC 27743

    COSTA, OSVALDO L. da ; SOUZA, DAIANE C.B. de ; CASTANHO, FABIO G. ; FEHER, ANSELMO ; MOURA, JOÃO A. ; SOUZA, CARLA D. ; OLIVEIRA, HENRIQUE B. ; MADUAR, MARCELO F. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Gamma spectrometry of iodine-125 produced in IEA-R1 nuclear reactor, using HPGe detector and fixation into epoxy matrix disc. Applied Radiation and Isotopes, v. 169, p. 1-6, 2021. DOI: 10.1016/j.apradiso.2020.109568

    Abstract: Few places in the world produce iodine-125. In Brazil, the first production was achieved by using the IEA-R1 nuclear reactor located at Nuclear and Energy Research Institute – IPEN. To verify the quality of iodine-125 produced, and the amount of contaminants such as iodine-126, cesium-134 and caesium-137 among others, iodine-125 samples were immobilized into epoxy matrix disc, with the same geometry of a barium-133 reference radioactive source, used to calibrate an HPGe detector. The HPGe detector has a thin carbon composite window, which allows measure the iodine-125 photopeaks, between 27.1 and 35.4 keV. The method employed here was successful in producing and measurement of iodine-125.

    Palavras-Chave: contamination; gamma spectroscopy; high-purity ge detectors; iodine 125; irradiation; quality control; volatility; brazilian cnen

  • IPEN-DOC 26206

    COSTA, OSVALDO L. da ; SOUZA, DAIANE C.B. de ; CASTANHO, FABIO G. ; FEHER, ANSELMO ; MOURA, JOÃO A. ; SOUZA, CARLA D. de ; OLIVEIRA, HENRIQUE B. de ; MADUAR, MARCELO F. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Gamma spectrometry of iodine-125 produced in IEA-R1 nuclear reator, using HPGe detector and fixation into epoxy matrix disc. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1176-1183.

    Abstract: Few places in the world produce iodine-125. In Brazil, the first production happened in nuclear reactor IEA-R1 located at Nuclear and Energy Research Institute – IPEN. To verify the quality of iodine-125 produced, because contaminants as iodine-126, caesium-134 and caesium-137 among others, may be produced in irradiation process, iodine-125 samples were immobilized into epoxy matrix disc, with the same geometry of a barium-133 reference radioactive source, used to calibrate an HPGe detector. The HPGe detector has a thin carbon composite window, which allows measure the iodine-125 photopeaks, between 27.1 and 35.4 keV.

    Palavras-Chave: contamination; gamma spectroscopy; high-purity ge detectors; iodine 125; irradiation; quality control; volatility; brazilian cnen

  • IPEN-DOC 29832

    COSTA, OSVALDO L. da ; BARCELLOS, HENRIQUE ; MATSUDA, HYLTON ; SUMIYA, LUIZ C. do A. ; JUNQUEIRA, FERNANDO de C. ; MATSUDA, MARGARETH M.N. ; LAPOLLI, ANDRE L. . A new 124Xe irradiation system for 123I production. Applied Radiation and Isotopes, v. 200, p. 1-7, 2023. DOI: 10.1016/j.apradiso.2023.110926

    Abstract: Since 2001, Nuclear and Energy Research Institute IPEN-CNEN has produced weekly ultrapure iodine-123, using a manual irradiation system, fully developed in IPEN. Iodine-123 radiopharmaceuticals have been produced and distributed to hospitals and clinics of nuclear medicine, where several diagnostic imaging procedures for thyroid, brain and cardiovascular functions are performed. Due to the short half-life and emission of low-energy photons, this radioisotope becomes suitable for diagnosis in children. In the present work, the technical and constructive aspects of a new fully automated irradiation system, dedicated to 123I routine production, employing enriched xenon-124 gas as the target material is presented. This new system consists of a target, a water and helium cooling system, a cryogenic system, an electric power system, and a control and process monitoring unit, composed of supervisory software, connected to a programmable logic controller via personal computer. In this new concept, there is no need for human intervention during radioisotope production, reducing the possibility of eventual failures or incidents involving radioactive material. By using this new system, a specific yield of 2.70 mCi/μAh per irradiation was achieved in validation runs, and after three years of routine production of iodine- 123, the system showed reliability and resilience.

    Palavras-Chave: cyclotrons; iodine 123; isotope production; xenon 124; targets; photon beams

  • IPEN-DOC 27362

    SOUZA, CARLA D. de ; ZEITUNI, CARLOS A. ; FEHER, ANSELMO ; MOURA, JOÃO A. ; COSTA, OSVALDO L. da ; ANGELOCCI, LUCAS V. ; ROSTELATO, MARIA E.C.M. . New core configuration for the fabrication of 125I radioactive sources for cancer treatment. Applied Radiation and Isotopes, v. 165, p. 1-8, 2020. DOI: 10.1016/j.apradiso.2020.109307

    Abstract: In order to provide prostate brachytherapy treatment for more Brazilian men, IPEN is building a laboratory for the manufacture of radioactive sources. The new methodology for the production of iodine-125 seeds with yield 71.7% ± 5.3%. Points of importance were evaluated/discussed: photo-sensibility, reaction vial type, the substitution for iodine-131, pH, and solution volume. The surface was analyzed by FTIR and EDS. At the end, a Monte Carlo-MCNP6 simulation was performed to evaluate the TG-43 parameters.

    Palavras-Chave: radiation sources; iodine 125; brachytherapy; radiation chemistry; monte carlo method; neoplasms; tumor cells; prostate; iodination

  • IPEN-DOC 13700

    COSTA, OSVALDO L. da . Otimizacao do sistema de carga e descarga no porta-alvo de irradiacao de Hsub(2) sup(18)O utilizado para a producao de sup(18)F no ciclotron cyclone 30 do IPEN-CNEN/SP / Load and unload system optimization on H2 18O irradiation target used for 18F - production at the cyclotron cyclone 30 from IPEN-CNEN/SP . 2009. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, Sao Paulo. 93 p. Orientador: Valdir Sciani. DOI: 10.11606/D.85.2009.tde-29062009-153847

    Abstract: O aumento da demanda no Brasil pelo radiofármaco [18F]FDG para exames de tomografia por emissão de pósitron (PET-CT) e sua meia-vida de 109,7 minutos exigem uma atenção especial para a cadeia produtiva deste radiofármaco. Desde a irradiação da água enriquecida em 18O até a passagem do paciente pelo tomógrafo, numa seqüência de procedimentos que pode durar até cerca de seis horas, todas as etapas da cadeia produtiva devem ter a maior confiabilidade possível, pois qualquer falha em uma das etapas será sentida na extremidade da cadeia produtiva. A falta de indicação de posição da válvula do Sistema de Carga e Descarga do Porta-alvo de 18F- no Centro de Aceleradores Cíclotron levou a perda de produção de 18F-, contaminação da Sala de Irradiação e aumento da dose dos trabalhadores envolvidos na operação e manutenção dos sistemas de irradiação. Este trabalho testou o comportamento de três tipos de sensores de posição (microswitch, reedswitch e sensor de proximidade indutivo) no ambiente da Sala de Irradiação 1.2 do Centro de Aceleradores Cíclotron, que está sujeito a altas taxas de radiação gama e nêutrons devido à produção rotineira de 18F- e 123I, através deste teste foi possível encontrar o sensor de posição mais adequado para trabalhar no porta-alvo de 18F-, e através da reprogramação do controlador lógico programável, foi possível evitar este tipo de falha durante a produção de 18F- no Centro de Aceleradores Cíclotron, e aumentar a confiabilidade na cadeia produtiva do [18F]FDG.

    Palavras-Chave: radioisotopes; positron computed tomography; fluorine 18; fluorine 18 target; cyclotrons; load analysis

  • IPEN-DOC 26564

    SOUZA, CARLA D. ; VICENTE, ROBERTO ; ROSTELATO, MARIA E.C.M. ; ZEITUNI, CARLOS A. ; MOURA, JOÃO A. ; MOURA, EDUARDO S. ; MATTOS, FABIO R. ; FEHER, ANSELMO ; COSTA, OSVALDO L. da ; VIANNA, ESTANISLAU B. ; CARVALHO, LAERCIO de ; KARAN JUNIOR, DIB. Preliminary proposal for radioactive liquid waste management in a brachytherapy sources production laboratory. In: DUDALA, JOANNA (Ed.); STEGOWSKI, ZDZISLAW (Ed.) INTERNATIONAL CONFERENCE ON DEVELOPMENT AND APPLICATIONS OF NUCLEAR TECHNOLOGIES, September 11-14, 2011, Krakow, Poland. Abstract... Krakow, Poland: Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, 2011. p. 48-48.

    Abstract: Malignant tumors are responsible for a high death rate in the entire world population (1). Prostate cancer is the third most common among men, after skin and lung. The treatment using permanent Iodine-125 seed are too costly, preventing the use in large scale (1) (2). A multidisciplinary team was formed to develop a source of Iodine-125 and assemble a national facility for local production. For the production correct implementation, a plan for radiological protection that has the management of radioactive waste fully specified are necessary. This work has developed an initial liquid waste management proposal. The most important Iodine-125 liquid waste is generated in the first phase of the process, radioactive material fixation. The initial proposal is that the waste is deposited in a 20 L container (2 years to fill). The final activity of this container is 4.93 x 1011 Bq. According to the discharge limits presented in the brazilian's regulation CNEN - NE - 605 - Management of radioactive wastes in radioactive facilities (3) this waste could safely be release to the environment in 3.97 years. In the other hand,if a minimization waste policy will be implemented, the production could becomes more efficient and cheaper. Waste storage at 25 L containers and changing some production parameters results in 3 years waste to be eliminated in 3.94 years. This new plan will optimize the materials used and diminished the waste generation facilitating the management, contributing to a cheaper product.

    Palavras-Chave: iodine 125; isotope production; liquid wastes; radioactive waste management; radioactive waste processing

  • IPEN-DOC 24094

    BARCELLOS, HENRIQUE ; MATSUDA, HYLTON ; SUMIYA, LUIZ C. do A. ; JUNQUEIRA, FERNANDO de C. ; COSTA, OSVALDO L. da . A simple and powerful XY-type current monitor for 30 MeV IPEN/CNEN-SP cyclotron. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A water-cooled XY-type current monitor was designed and built in the Cyclotrons Laboratory of the Nuclear and Energy Research Institute (IPEN). It is a very simple design and easily adaptable to the cyclotron beam lines. Tests were done demonstrating to be an instrument of great assistance in proton beam position along beam transport line and target port. Nowadays the XY-type current monitor has been widely used in 18F-FDG routine productions, employing irradiation system which were originally designed for productions on 18 MeV cyclotron accelerator only, however, applying the XY-type current monitor the target port may be exchanged between the 30 MeV and 18 MeV cyclotrons and the observed results are in perfect agreement with expected.

    Palavras-Chave: beam currents; beam monitoring; beam monitors; design; mev range 10-100; proton beams; testing

  • IPEN-DOC 21310

    COSTA, OSVALDO L. da ; FEHER, ANSELMO ; MOURA, CARLA D.; TIEZZI, RODRIGO ; SOUZA, DAIANE C.B. de ; MOURA, EDUARDO S. ; OLIVEIRA, HENRIQUE B. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Study and evaluation of aluminium capsules to irradiation of gaseous samples in nuclear rector. Journal of Physical Science and Application, v. 5, n. 4, p. 263-267, 2015.

    Palavras-Chave: aluminium; capsules; irradiation; gases; research reactors; iso

  • IPEN-DOC 20064

    COSTA, OSVALDO L. da. Testing which is the fitter position sensor for a cyclotron liquid target. Applied Radiation and Isotopes, v. 83, p. 37-40, 2014.

    Palavras-Chave: cyclotrons; fluorine 18 target; fluorodeoxyglucose; positron computed tomography; computerized tomography; diagnosis; neoplasms

  • IPEN-DOC 27037

    ROSTELATO, MARIA E.C.M. ; SOUZA, CARLA D. de ; SOUZA, DAIANE C.B. de ; ZEITUNI, CARLOS A. ; TIEZZI, RODRIGO ; COSTA, OSVALDO L. da ; RODRIGUES, BRUNA T. ; MOURA, JOÃO A. ; FEHER, ANSELMO ; SORGATTI, ANDERSON ; MOURA, EDUARDO S. de ; MARQUES, JOSE R. de O. ; SANTOS, RAFAEL M. dos ; KARAM JUNIOR, DIB. Waste management protocols for Iridium-192 sources production laboratory used in cancer treatment. In: CLEMENT, CHRISTOPHER (Ed.); VALENTIN, JACK (Ed.); OGINO, HARUYUKI (Ed.); FOOTE, DEVON (Ed.); REYJAL, JULIE (Ed.); OMAR-NAZIR, LAILA (Ed.) INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 14th, May 9-13, 2016, Cape Town, South Africa. Abstract... The International Radiation Protection Association, 2016. p. 2038-2038.

    Abstract: Introduction: Brachytherapy is a form of treatment that uses radioactive seeds placed in contact or inside the region to be treated, maximizing the radiation dose inside the targeted areas. Iridium-192 is being used in brachytherapy since 1955. It presents emission energy in the “therapy region” (370keV) and is easily produced in a nuclear reactor (191Ir (n, γ) → 192Ir). Wires are an iridium-platinum alloy with 0.36 mm diameter and they can be cut in any needed length. They can be used in several types of cancer. The linear activity is between 1 mCi/cm (37 MBq/cm) and 4 mCi/cm (148 MBq/cm) with variations of 10% in 50 cm maximum. This activity values classified the treatment and low dose rate (0,4 à 2 Gy/h). The propose of this work is to present a waste management system in a cancer treatment radioactive sources production laboratory. Methodology and Results: The solid waste is previously characterized in the analysis phase. The contaminants are already known and they are insignificant due to their fast half- life. The iridium-192 half-life is 74.2 days, classified as very short half-life waste. The waste activity is adds to 8mCi (2.96x108 Bq) per wire. According to the CNEN-NN 6.08 standard, that presents the discharge levels, the limit is 1 kBq.kg-1 (2.7x10-5 mCi.kg-1). The radioactive waste generated during the I192 wires production has a weakly activity of 9.7 GBq.g-1. According to the standards, this activity is too high to be discarded into the environment. The waste must be managed following the ALARA principal using the R&R (retain e retard) system, that means, temporary storage and posterior discharge. Since every 4 months, maintenance is performed inside the hot cell used for production, the waste must be removed. Using the equation: 𝐴 = 𝐿 λ (1 − 𝑒−λt), the total calculated activity is 1.68 x 1016 Bq and 4.8 g mass at the end of each 4 months period. This amount is stored inside a shielding device that has 212.37 cm3 volume. The waste will take 9.8 years (calculated by 𝐴 = 𝐴0(𝑒−λt)) to decay to the discharge levels. To store 30 devices during 10 years, a space with 6,370 cm3 is necessary. The laboratory has enough space for this storage. Thus, the radioactive waste management can be performed through the R&R (retain and retard) system safely.

    Palavras-Chave: waste management; radioactive materials; radioactive wastes; neoplasms; therapy; iridium 192; radioactive waste management; sealed sources; brachytherapy

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.