Navegação IPEN por Autores IPEN "COSTA, PRISCILA"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 25015

    SILVA, ANDRE F. ; COSTA, PRISCILA ; MACHADO, NOE G.P. ; SAMAD, RICARDO E. ; ZEZELL, DENISE M. ; RAELE, MARCUS P. ; ZAMATARO, CLAUDIA B. . Analysis of temperature on microscope slide by a boron pulsed laser deposition process. In: ENCONTRO DE OUTONO, 41., 06-11 de maio, 2018, Foz do Iguaçu, PR. Resumo... São Paulo: Sociedade Brasileira de Física, 2018. p. 1-1.

    Abstract: A boron thin ¯lm can be used for neutrons conversion and in electrically charged particles and further detection. Since boron has a high evaporation temperature and the thickness of the boron layer needs to have few microns, pulsed laser deposition also known as PLD can be used. When producing thin ¯lms with the PLD technique, the target absorbs energy promoting the material ablation creating a plasma plume that deposits material on a substrate, thus creating a thin ¯lm. Since all the deposition occurs in a vacuum chamber, the residual heat of the plasma that condensate at the substrate can build up, thus potentially source of concern if the substrate sensitive to temperature somehow. This work reports the analysis of the variation of temperature in a microscope slide (substrate) as a function of the energy of femtosecond laser pulses. For measuring the substrate temperature a type-K thermocouple was used together with associated electronics. The thermocouple was ¯xed to the back of substrate with thermal grease for vacuum and connected to the microchip using a feed through in the vacuum chamber. Was detected the increase of the substrate+¯lm starting at 6oC from initial temperature (room) for the minimal laser energy 100 microjoules (25 femtoseconds).

  • IPEN-DOC 25742

    COSTA, PRISCILA ; RAELE, MARCUS P. ; MACHADO, NOE G.P. ; SILVA, ANDRE F. ; VIEIRA JUNIOR, NILSON D. ; GENEZINI, FREDERICO A. ; SAMAD, RICARDO E. . Boron film laser deposition by ultrashort pulses for use as neutron converter material. Applied Physics A: Materials Science and Processing, v. 125, n. 2, p. 1-8, 2019. DOI: 10.1007/s00339-019-2382-6

    Abstract: This study investigated the production of boron films by femtosecond pulsed laser deposition (PLD) to be used as converters on bulk semiconductor neutron detectors. The ablation threshold of metallic boron was determined and the film growth was studied as a function of deposition time (5–90 min) and laser pulse energy (35–530 μJ). The films were characterized by scanning electron microscopy (SEM), revealing a flaky morphology, optical profilometry, which determined the films thicknesses (from 80 nm up to 4 μm), Ion Beam Analysis (IBA) that assessed their elemental composition and X-ray diffraction (XRD), which revealed an amorphous structure. In addition, a thermal load study was performed to evaluate the heat flux onto the substrate during deposition process. Stable boron films obtained show that the femtosecond PLD process is reliable and reproducible for the fabrication of thick boron coatings.

    Palavras-Chave: boron; neutron converters; films; lasers; ablation; ion beams; beam analyzers

  • IPEN-DOC 21130

    COSTA, PRISCILA ; RAELE, MARCUS P. ; YORIYAZ, HELIO ; SIQUEIRA, PAULO de T.D. ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Boron film thickness determination to develop a low cost neutron using Monte Carlo Method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: boron; thin films; monte carlo method; neutron flux; neutron detection; alpha particles; thermal neutrons; charged particles; computerized simulation; photodiodes; silicon; thickness

  • IPEN-DOC 26204

    COSTA, PRISCILA ; RAELE, MARCUS P. ; DOMIENIKAN, CLAUDIO ; MADI FILHO, TUFIC ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Characterization of a portable thermal neutron detector. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1163-1170.

    Abstract: A portable thermal neutron detector prototype, using a PIN-type silicon photodiode coupled to a boron converter, was developed at the Nuclear and Energy Research Institute (IPEN-CNEN/SP). Several boron layers were made by Pulsed Laser Deposition method and two different prototypes were made using distinct approaches in the associated electronics. The prototypes were characterized by measurements with the cold neutron beam at PHADES (Polarized 3He and Detector Experiment Station), in the NIST Center for Neutron Research. The distance between the prototype and the neutron source was different for each prototype: 70 cm (prototype one) and 7 cm (prototype two). The linearity behavior was verified for both prototypes in order to verify the relationship between counts and neutron fluence. The intrinsic efficiency values obtained for prototypes one and two were, respectively, (1.78 ± 0.01)% and (5.2 ± 0.4)%. The angular dependence was verified only for prototype one. The concept of this detector can be applied in a future dosimeter project.

    Palavras-Chave: thermal neutrons; photodiodes; portable equipment; silicon; cold neutrons; efficiency; neutron detectors; brazilian cnen

  • IPEN-DOC 21129

    COSTA, PRISCILA ; POTIENS JUNIOR, ADEMAR J. . Characterization of the water filters cartridges from the IEA-R1 reactor using the Monte Carlo Method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: iear-1 reactor; monte carlo method; water treatment; calibration; radioactive wastes; computerized simulation; cross sections; gamma spectroscopy; nondestructive analysis; radiation transport

  • IPEN-DOC 26847

    COSTA, PRISCILA ; RAELE, MARCUS P. ; DOMIENIKAN, CLAUDIO ; COSTA, FABIO E. ; MADI FILHO, TUFIC ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . A compact electronic system for a photodiode neutron detector. In: JAKSIC, ALEKSANDAR (Ed.); KARAMARKOVIC, JUGOSLAV (Ed.) INTERNATIONAL CONFERENCE ON RADIATION APPLICATIONS, September 16-19, 2019, Belgrade, Serbia. Abstract... Niš, Serbia: Sievert Association, 2019. p. 36-36.

    Abstract: The demand for portable neutron detectors is on the rise, and for that purpose, low cost boron-10 has been frequently used instead of helium-3, which is usually employed in large and expensive detectors. Portable detectors are of interest in some applications, such as neutron dosimeters or inspection systems targeted in the detection of fissile material and drugs in airports. In this work a portable thermal neutron detection system was developed which is based on a commercial silicon photodiode coupled to a boron converter; this prototype is then plugged into a portable electronic system. The boron layer was produced by pulsed laser deposition, either on a thin glass slide or on the photodiode itself. The boron deposition in the photodiode was made directly in the active area of the detector, so before and after the deposition process a characterization of the device regarding both the dark current and the operation voltage was performed using an americium source. Finally, both configurations were tested. The neutron detection process occurs by detecting the alpha and lithium particles produced by the interaction of the incoming neutron with the boron-10 nuclides. These heavy ions then interact with the active area of the reverse-biased photodiode, producing an electric signal that has to be preamplified and then properly amplified by the portable electronic system, which in turn produces an output that can either be sent to a multichannel analyzer or to a digital counter. The integrated circuit of the low noise preamplifier transforms the detector’s current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy output pulse. The performance of the photodiode-amplifier set for alpha particles was successively tested using a 243Am radioactive source. Initial tests were made using the boron-deposited glass, and the electronic signal was properly read. However, when the same system was tested using the boron deposited directly in the photodiode, the output signal couldn’t be read, due to the fact that during the deposition process there was an increase in the dark current and a decrease in the operation bias. In this way, a new portable electronic system was developed using a hybrid integrated amplifier circuit. This new electronic setup allowed the use of both configurations, and was tested both with alpha-emitting Americium and neutron-emitting AmBe sources. In conclusion, both portable electronic systems have proven suitable for the thermal neutron detector developed.

  • IPEN-DOC 29584

    VICENTE, ROBERTO ; DELLAMANO, JOSE C. ; COSTA, PRISCILA ; CABRERA, PALOMA S. ; SMITH, RICARDO B. . Definição dos lotes para amostragem dos rejeitos históricos (Estudo de critérios e métodos para a determinação de lotes dos rejeitos radioativos históricos gerados entre 1982 e 2015 na Unidade I da CNAAA). São Paulo: Instituto de Pesquisas Energéticas e Nucleares - CEENG, Novembro, 2022. (IPEN-CEN-P&D-ETN-218-01-INFT-006-00). Restrito.

    Título do projeto: Composição Isotópica dos Rejeitos Radioativos da CNAAA

    Abstract: Este documento tem como objetivo o estudo da base de dados sobre os rejeitos radioativos históricos armazenados na Unidade I da Central Nuclear Almirante Álvaro Alberto (CNAAA) e os critérios utilizados para identificação de possíveis lotes homogêneos de rejeito, dos quais possam ser retiradas amostras representativas que dispensem a abertura de todos os embalados. O presente relatório técnico foi elaborado em atendimento ao item 8.2.2 do Plano de trabalho anexo ao Acordo “Determinação da Composição Isotópica dos Rejeitos Radioativos da CNAAA (Fase B)”, do ACORDO DE PARCERIA TECNOLÓGICA firmado entre a ELETROBRÁS TERMONUCLEAR S.A., a CNEN - COMISSÃO NACIONAL DE ENERGIA NUCLEAR e a FUNDEP – Fundação de Desenvolvimento da Pesquisa.

    Palavras-Chave: radioactive wastes; waste storage; waste management; sampling; radioisotopes; inventories

  • IPEN-DOC 29586

    VICENTE, ROBERTO ; DELLAMANO, JOSE C. ; COSTA, PRISCILA ; CABRERA, PALOMA S. ; SMITH, RICARDO B. . Definição dos lotes para amostragem dos rejeitos históricos (Estudo de critérios e métodos para a determinação de lotes dos rejeitos radioativos históricos gerados entre 2002 e 2014 na Unidade II da CNAAA). São Paulo: Instituto de Pesquisas Energéticas e Nucleares - CEENG, Novembro, 2022. (IPEN-CEN-P&D-ETN-218-01-INFT-008-00). Restrito.

    Título do projeto: Composição Isotópica dos Rejeitos Radioativos da CNAAA

    Abstract: Este documento tem como objetivo relatar o estudo da base de dados REJAN sobre os rejeitos radioativos históricos produzidos na Unidade II da Central Nuclear Almirante Álvaro Alberto (CNAAA) e os critérios utilizados para identificação de possíveis lotes homogêneos de rejeito, dos quais possam ser retiradas amostras representativas que dispensem a amostragem de todos os embalados. O presente relatório técnico foi elaborado em atendimento ao item 8.2.2 do Plano de trabalho anexo ao Acordo “Determinação da Composição Isotópica dos Rejeitos Radioativos da CNAAA (Fase B)”, do ACORDO DE PARCERIA TECNOLÓGICA firmado entre a ELETROBRÁS TERMONUCLEAR S.A., a CNEN - COMISSÃO NACIONAL DE ENERGIA NUCLEAR e a FUNDEP – Fundação de Desenvolvimento da Pesquisa, e complementa o relatório P&D-CEN-ETN 218-01- INFT-006-00.

    Palavras-Chave: sampling; radioactive wastes; isotope ratio; inventories; data analysis

  • IPEN-DOC 27758

    COSTA, PRISCILA ; VICENTE, ROBERTO ; RAELE, MARCUS P. . Descontaminação de rejeitos radioativos por ablação com laser. São Paulo: Instituto de Pesquisas Energéticas e Nucleares - GRR, Junho, 2021. (IPEN/GRR-REL-06/21). Aberto.

    Título do projeto: Relatório Técnico do Pós-Doutorado

    Abstract: O presente trabalho tem como finalidade contribuir para o desenvolvimento de métodos de tratamento de rejeitos radioativos, no Serviço de Gerência de Rejeitos Radioativos do Instituto de Pesquisas Energéticas e Nucleares- IPEN, direcionados à descontaminação superficial dos rejeitos radioativos via ablação a laser. Esta técnica permite a redução no volume desse material a ser tratado e também a possibilidade de reuso. Os materiais escolhidos neste trabalho visam simular os mesmos utilizados nas instalações nucleares.

    Palavras-Chave: decontamination; radioactive wastes; lasers; ablation; nuclear facilities; research reactors; rmb reactor; fuel cells; ducts

  • IPEN-DOC 25683

    COSTA, PRISCILA . Desenvolvimento de um detector de nêutrons por meio da deposição de filme fino de boro via laser / Development of a thermal neutron detector by boron film deposition using laser . 2019. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 98 p. Orientador: Frederico Antonio Genezini. DOI: 10.11606/T.85.2019.tde-07062019-161822

    Abstract: O protótipo de um detector de nêutrons térmicos portátil foi desenvolvido no Instituto de Pesquisa Energéticas e Nucleares (IPEN-CNEN/SP), utilizando um fotodiodo de Si do tipo PIN associado a um filme de boro enriquecido. O filme de boro foi fabricado por meio da técnica de Deposição a Laser Pulsado, considerando duas possibilidades para depositar o boro: deposição direta do boro na face do fotodiodo e deposição na lâmina de vidro. Foram desenvolvidos dois protótipos, no primeiro foi possível ler apenas o sinal elétrico do sistema fotodiodo-boro no qual o filme está depositado na lâmina de vidro. Para aprimorar a resposta do sistema de detecção, outro circuito foi desenvolvido e permitiu contar nêutrons em ambas as situações tanto do filme na lamínula quanto do filme direto no fotodiodo. A caracterização dos protótipos foi feita via irradiação de feixes de nêutrons predominantemente térmicos e frios, por meio de quatro experimentos principais: reposta do sistema ao fluxo de nêutrons, teste de linearidade, resposta angular e o teste de reprodutibilidade. Os protótipos apresentaram uma resposta linear à variação do fluxo, reprodutibilidade, e a resposta angular não foi isotrópica. A eficiência intrínseca em porcentagem do protótipo 1 para um espectro de nêutrons predominantemente térmicos e frios foi (1,17 ± 0,01) % e (1,37 ± 0,01) %, respectivamente. No protótipo 2 foram feitas medições de nêutrons com os dois sistemas fotodiodo-boro (lâmina de vidro, direto no fotodiodo), porém nas medidas com o boro direto no sensor houve um aumento significativo no ruído eletrônico. A eficiência intrínseca do protótipo 2 para os nêutrons frios foi de (5,2 ± 0,4) %.

    Palavras-Chave: boron compounds; films; neutron detectors; thermal nêutrons; thin films; deposition; lasers; pulses; photodiodes; photodetectors; developers

  • IPEN-DOC 20699

    COSTA, PRISCILA . Desenvolvimento de uma metodologia para caracterização do filtro cuno do reator IEA-R1 utilizando o método de Monte Carlo / Development of methodology for characterization of cartridge filters from the IEA-R1 using the Monte Carlo method . 2014. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 53 p. Orientador: Ademar José Potiens Junior. DOI: 10.11606/D.85.2015.tde-23032015-081657

    Abstract: O filtro cuno faz parte do circuito de tratamento de água do reator IEA-R1 que , quando saturado, é substituído, se tornando um rejeito radioativo que deve ser gerenciado. Neste trabalho foi realizada a caracterização primária do filtro cuno do reator nuclear IEA-R1 do IPEN utilizando-se espectrometria gama associada ao método de Monte Carlo. A espectrometria gama foi realizada utilizando-se um detector de germânio hiperpuro (HPGe). O cristal de germânio representa o volume ativo de detecção do detector HPGe, que possui uma região denominada camada morta ou camada inativa. Na literatura tem sido reportada uma diferença entre os valores experimentais e teóricos na obtenção da curva de eficiência desses detectores. Neste trabalho foi utilizado o código MCNP-4C para a obtenção da calibração em eficiência do detector para a geometria do filtro cuno, onde foram estudadas as influências da camada morta e do efeito de soma em cascata no detector HPGe. As correções dos valores de camada morta foram realizadas variando-se a espessura e o raio do cristal de germânio. O detector possui 75,83 cm3 de volume ativo de detecção, segundo informações fornecidas pelo fabricante. Entretanto os resultados encontrados mostraram que o valor de volume ativo real é menor do que o especificado, onde a camada morta representa 16% do volume total do cristal. A análise do filtro cuno por meio da espectrometria gama, permitiu a identificação de picos de energia. Por meio desses picos foram identificados três radionuclídeos no filtro: 108mAg, 110mAg e 60Co. A partir da calibração em eficiência obtida pelo método de Monte Carlo, o valor de atividade estimado para esses radionuclídeos está na ordem de MBq.

    Palavras-Chave: iear-1 reactor; filters; water treatment; radioactive wastes; gamma spectroscopy; monte carlo method; high-purity ge detectors; m codes; calibration

  • IPEN-DOC 24157

    COSTA, PRISCILA ; COSTA, FABIO E. ; RAELE, MARCUS P. ; ZAHN, GUILHERME S. ; GERALDO, BIANCA ; VIEIRA JUNIOR, NILSON D. ; SAMAD, RICARDO E. ; GENEZINI, FREDERICO A. . Eletronic response of a photodiode coupled to a boron thin film. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A portable thermal neutron detector is proposed in this work using a silicon photodiode coupled to a boron thin film. The aim of this work was to verify the effect in the electronic response of this specific photodiode due to boron deposition, since the direct deposition of boron in the semiconductor surface could affect its electrical properties specifically the p-type layer that affects directly the depletion region of the semiconductor reducing the neutron detector efficiency count. Three boron depositions with different thickness were performed in the photodiode (S3590-09) surface by pulsed laser deposition and the photodiode was characterized, before and after the deposition process, using a radioactive americium source. Energy spectra were used to verify the electronic response of the photodiode, due to the fact that it is possible to relate it to the photopeak pulse height and resolution. Spectra from the photodiode without and with boron film deposition were compared and a standard photodiode (S3590-04) that had the electronic signal conserved was used as reference to the pulse height for electronics adjustments. The photopeak energy resolution for the photodiode without boron layer was 10.26%. For the photodiode with boron deposition at different thicknesses, the resolution was: 7.64 % (0.14 μm), 7.30 % (0.44 μm) and 6.80 % (0.63 μm). From these results it is possible to evaluate that there was not any degradation in the silicon photodiode.

    Palavras-Chave: americium 241; boron; electrical properties; energy spectra; brazilian cnen; neutron detectors; photodiodes; portable equipment; thermal neutrons; thin films

  • IPEN-DOC 24814

    COSTA, PRISCILA ; RAELE, MARCUS P. ; SAMAD, RICARDO E. ; MACHADO, NOE G.P. ; VIEIRA JUNIOR, NILSON D. ; GENEZINI, FREDERICO A. . Femtosecond pulsed laser deposition of a boron thin film aiming at the development of a low-cost neutron detector. In: KAIERLE, STEFAN (Ed.); HEINEMANN, STEFAN W. (Ed.) HIGH-POWER LASER MATERIALS PROCESSING: APPLICATIONS, DIAGNOSTICS, AND SYSTEMS, 7th, January 27 - February 01, 2018, San Francisco, California, USA. Proceedings... Bellingham, WA, USA: Society of Photo-optical Instrumentation Engineers, 2018. p. 105250J-1 - 105250J-7. (SPIE Proceedings Series, 10525). DOI: 10.1117/12.2285896

    Abstract: Boron thin films were produced using femtosecond pulsed laser deposition aiming at the development of a neutron detector. As neutrons have no charge, in order to detect this particle converter materials are applied, promoting nuclear reactions that result in the emission of charged particles, allowing the neutrons presence to be indirectly inferred. Among the possible conversion materials, 10B has a considerable cross section for thermal neutrons and accessible cost. Furthermore, the nuclear reaction produces easily detectable alpha particles, making it a rational option to develop a low cost and portable neutron detector. The boron ablation threshold fluence has been measured by the Diagonal Scan (Dscan) technique that resulted in the minimum laser energy value of 17.7 (6) μJ and fluence of 5.63(19) J/cm2. Boron deposition was performed varying the pulse energy and deposition duration. The growth rate, morphological and physical aspects of the boron pulsed laser deposition were characterized by a Scanning Electron Microscope and an optical profilometer. The films surfaces have a flaky aspect with eventual droplets which had decayed overtime to a more smooth surface. The studied parameters allowed producing a boron coating with the optimal thickness in order to minimize self-absorption effect in the film, thus increasing efficiency.

    Palavras-Chave: laser radiation; neutron detectors; boron; thin films; lasers; ablation; scanning electron microscopy; thickness; deposition

  • IPEN-DOC 29071

    COSTA, PRISCILA ; VICENTE, ROBERTO ; GENEZINI, FREDERICO A. ; ROSSI, WAGNER de ; RAELE, MARCUS P. . Laser decontamination of surface impregnated with radioactive material. Journal of Radioanalytical and Nuclear Chemistry, v. 331, n. 11, p. 4553-4561, 2022. DOI: 10.1007/s10967-022-08525-5

    Abstract: Pulsed lasers can evaporate (ablate) metals and polymers, carrying away radioactive contaminants. Several studies found in the literature lack information or cannot be compared due to the different methodologies, thus the current study aimed to test a wide range of samples using the same method. A Nd:YAG nanosecond laser operating at 1064 nm was used to process four different types of polymers and six metals, using fluences ranging from 1 to 10 J/cm2. Samples were contaminated with an acid solution containing 137Cs. Weighting the effectiveness and yield, 5 J/cm2 was shown to be the most viable irradiation condition.

    Palavras-Chave: ablation; cesium 137; decontamination; inorganic acids; irradiation; neodymium lasers; polymers; radioactive materials; solutions

  • IPEN-DOC 24095

    DOMIENIKAN, CLAUDIO ; COSTA, PRISCILA ; GENEZINI, FREDERICO A. ; ZAHN, GUILHERME S. . Low-cost amplifier for alpha detection with photodiode. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A low-cost amplifier for Hamamatsu S3590-09 PIN photodiode to be used in alfa detection is presented. This amplifier consists basically of two circuits: a pulse preamplifier and a shaper-driver. The PIN photodiode is reverse-biased and connected to a charge preamplifier input. Incident alpha particles generate a small current pulse in the photodiode. The integrating circuit of the low noise preamplifier transforms current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy pulse. The performance of the set photodiode-amplifier was successively tested through the use of a 243Am radioactive source. The low-cost photodiode amplifier was designed and constructed at IPEN - CNEN/SP using national components and expertise.

    Palavras-Chave: alpha detection; alpha spectrometers; americium 243; amplifiers; performance; photodiodes; brazilian cnen; radiation monitoring

  • IPEN-DOC 27065

    COSTA, PRISCILA ; RAELE, MARCUS P. ; YORIYAZ, HELIO ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Modelling a prototype of thermal neutron detector using a thin boron film and a photodiode. In: ENCONTRO DE FÍSICA; ENCONTRO NACIONAL DE FÍSICA DA MATÉRIA CONDENSADA, 39.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 39.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 37.; ENCONTRO BRASILEIRO DE FÍSICA DOS PLASMAS, 13.; ENCONTRO DE PESQUISA EM ENSINO DE FÍSICA, 16., 3-7 de setembro, 2016, Natal, RN. Resumo... São Paulo, SP: Sociedade Brasileira de Física, 2016.

    Abstract: Neutron detection is an important task especially for worker protection in nuclear installations. For that purpose, it is desired to have portable and compact detectors, an aim which can be achieved using semiconductor detectors. In this work the Monte Carlo modelling of a neutron detector based on a thin boron film and photodiode is presented. The simulation was carried out using the MCNP6 code, in order to evaluate the detection efficiency for the alpha particles emitted in the boron neutron capture reaction. Two different setup subsets were modelled, taking into account the fact that the film could be deposited either in direct contact to the photodiode surface, or in indirect contact, where the film was deposited in a substrate (glass). In direct contact the thin film thickness ranged from 0 to 5 μm. For the indirect contact the thicknesses of the substrate and air region were varied. For both cases, the model was also prepared to consider the situation in which the film was sandwiched between two photodiodes in order to increase alpha particle detection efficiency. The results show that the thickness of the substrate, of 150 μm or 1000 μm, has a small influence on the alpha particle flux on the photodiode surface. The increase of the air region causes a decrease of 57 % in the flux of alpha particles in the photodiode. These different setups allowed determining the thickness values of thin boron film that delivers a higher alpha particle flux, which will lead to an optimum detection efficiency.

  • IPEN-DOC 24097

    COSTA, PRISCILA ; GERALDO, BIANCA ; RAELE, MARCUS P. ; MARUMO, JULIO T. ; VICENTE, ROBERTO ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Production of a square geometry americium standard source for use with photodiodes. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: In the development of a thermal neutron detector using a square photodiode and a thin boron film, a radioactive calibration source with the same geometry was needed. An americium-243 standard source was produced by electrodeposition aiming at the calibration of a PIN-type silicon photodiode with a detection area of 10 x 10 mm2. To produce the samples two tests were performed. In the first test, a square stainless steel plate (10 x 10 mm2) was fixed on the surface of the conventional plate, which was removed after deposition. To reduce the loss of activity of the source, in the second test nail polish was applied on the silver plate leaving only an area of 10 x 10 mm2 without varnish coating. Once the electrodeposition process was completed, the activity concentration measurement was performed by alpha particle spectrometry. The first method presented a lower activity when compared to the total activity of Am-243 added initially. For the second method, the total activity was concetrated in the exposed square region (without nail polish).The results showed that it is possible to obtain a square geometry source; furthermore, the surrounding nail polish was not contaminated by 243Am. The comparison of these two approaches indicated that the second method was more efficient as it was possible to concentrate all the americium activity in the delimitated square area.

    Palavras-Chave: americium 243; boron; calibration; electrodeposition; neutron detectors; photodiodes; brazilian cnen; silicon; square configuration; stainless steels; thermal neutrons; thin films

  • IPEN-DOC 22201

    PEREIRA, MARIA da C.C. ; MADI FILHO, TUFIC ; CARDENAS, JOSE P.N. ; VIVOLO, VITOR ; BERRETTA, JOSE R. ; FERNANDES, VAGNER ; KUAHARA, LILIAN T. ; MARQUES, CAIO P. ; COSTA, PRISCILA . Study of plastic scintillator detector for beta and gamma radiation measurement. In: SIMPOSIO INTERNACIONAL SOBRE EDUCACION, CAPACITACION Y GESTION DEL CONOCIMIENTO EN ENERGIA NUCLEAR Y SUS APPLICACIONES, 22-26 de noviembre, 2015, Cusco, Peru. Proceedings... 2015.

    Palavras-Chave: radiation detectors; beta detection; gamma detection; plastic scintillators; education

  • IPEN-DOC 29363

    COSTA, PRISCILA ; STIPP, WAGNER ; VICENTE, ROBERTO ; MACHADO, NOE G.P. ; RAELE, MARCUS P. . Study on the potential of laser ablation to decontaminate radioactive waste. In: LATIN AMERICA OPTICS AND PHOTONICS CONFERENCE, August 7-11, 2022, Recife, PE. Proceedings... Washington, DC, USA: Optica Publishing Group, 2022. DOI: 10.1364/LAOP.2022.W3B.2

    Abstract: Laser is a promising tool to decontaminate radioactive waste that is impregnated with radionuclides on its surface, the decontamination process has no chemical inputs, and the pollutants can be fixed in HEPA filters. The current study aimed to test a wide range of samples using 10 different materials and fluences ranging from 1 to 10 J/cm2.

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.