Navegação IPEN por Autores IPEN "DOMIENIKAN, CLAUDIO"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 12045

    MERCURIO, MARCIO E.; CARBONARI, ARTUR W. ; DOMIENIKAN, CLAUDIO ; SAXENA, RAJENDRA N. ; CORDEIRO, MOACIR R.; PEREIRA, LUCIANO F.D.. An elelectronic delay for perturbed gama-gama angular correlation spectrometer. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: coincidence methods; dead time; delay circuits; experimental data; gamma cascades; hafnium 181; perturbed angular correlation; pulses; sensitivity

  • IPEN-DOC 26204

    COSTA, PRISCILA ; RAELE, MARCUS P. ; DOMIENIKAN, CLAUDIO ; MADI FILHO, TUFIC ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Characterization of a portable thermal neutron detector. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1163-1170.

    Abstract: A portable thermal neutron detector prototype, using a PIN-type silicon photodiode coupled to a boron converter, was developed at the Nuclear and Energy Research Institute (IPEN-CNEN/SP). Several boron layers were made by Pulsed Laser Deposition method and two different prototypes were made using distinct approaches in the associated electronics. The prototypes were characterized by measurements with the cold neutron beam at PHADES (Polarized 3He and Detector Experiment Station), in the NIST Center for Neutron Research. The distance between the prototype and the neutron source was different for each prototype: 70 cm (prototype one) and 7 cm (prototype two). The linearity behavior was verified for both prototypes in order to verify the relationship between counts and neutron fluence. The intrinsic efficiency values obtained for prototypes one and two were, respectively, (1.78 ± 0.01)% and (5.2 ± 0.4)%. The angular dependence was verified only for prototype one. The concept of this detector can be applied in a future dosimeter project.

    Palavras-Chave: thermal neutrons; photodiodes; portable equipment; silicon; cold neutrons; efficiency; neutron detectors; brazilian cnen

  • IPEN-DOC 26847

    COSTA, PRISCILA ; RAELE, MARCUS P. ; DOMIENIKAN, CLAUDIO ; COSTA, FABIO E. ; MADI FILHO, TUFIC ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . A compact electronic system for a photodiode neutron detector. In: JAKSIC, ALEKSANDAR (Ed.); KARAMARKOVIC, JUGOSLAV (Ed.) INTERNATIONAL CONFERENCE ON RADIATION APPLICATIONS, September 16-19, 2019, Belgrade, Serbia. Abstract... Niš, Serbia: Sievert Association, 2019. p. 36-36.

    Abstract: The demand for portable neutron detectors is on the rise, and for that purpose, low cost boron-10 has been frequently used instead of helium-3, which is usually employed in large and expensive detectors. Portable detectors are of interest in some applications, such as neutron dosimeters or inspection systems targeted in the detection of fissile material and drugs in airports. In this work a portable thermal neutron detection system was developed which is based on a commercial silicon photodiode coupled to a boron converter; this prototype is then plugged into a portable electronic system. The boron layer was produced by pulsed laser deposition, either on a thin glass slide or on the photodiode itself. The boron deposition in the photodiode was made directly in the active area of the detector, so before and after the deposition process a characterization of the device regarding both the dark current and the operation voltage was performed using an americium source. Finally, both configurations were tested. The neutron detection process occurs by detecting the alpha and lithium particles produced by the interaction of the incoming neutron with the boron-10 nuclides. These heavy ions then interact with the active area of the reverse-biased photodiode, producing an electric signal that has to be preamplified and then properly amplified by the portable electronic system, which in turn produces an output that can either be sent to a multichannel analyzer or to a digital counter. The integrated circuit of the low noise preamplifier transforms the detector’s current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy output pulse. The performance of the photodiode-amplifier set for alpha particles was successively tested using a 243Am radioactive source. Initial tests were made using the boron-deposited glass, and the electronic signal was properly read. However, when the same system was tested using the boron deposited directly in the photodiode, the output signal couldn’t be read, due to the fact that during the deposition process there was an increase in the dark current and a decrease in the operation bias. In this way, a new portable electronic system was developed using a hybrid integrated amplifier circuit. This new electronic setup allowed the use of both configurations, and was tested both with alpha-emitting Americium and neutron-emitting AmBe sources. In conclusion, both portable electronic systems have proven suitable for the thermal neutron detector developed.

  • IPEN-DOC 22026

    DOMIENIKAN, CLAUDIO . Desenvolvimento de um espectrômetro de correlação angular gama-gama perturbada com seis detectores de BaF2 e estudo de interações hiperfinas em composto intermetálico LaMnSi2 / Development of a perturbed gama-gama angular correlation spectrometer with six BaF2 detectors and study of hiperfine interaction in the intermetallic compound LaMnSi2 . 2016. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 89 p. Orientador: Rajendra Narain Saxena. DOI: 10.11606/T.85.2016.tde-05122016-144851

    Abstract: Neste trabalho foi desenvolvido um Espectrômetro de Correlação Angular Gama- Gama Perturbada Diferencial em Tempo (CAP) constituído por seis detectores cintiladores de BaF2, para realização de medidas de interações hiperfinas (campo hiperfino magnético e gradiente de campo elétrico) em diversos materiais e propiciar estudos na área da física da matéria condensada. O espectrômetro desenvolvido possui um sistema de aquisição não convencional em comparação aos demais equipamentos destinados a medidas de CAP. Ao invés do tradicional Analisador Multicanal (MCA), este espectrômetro utiliza um sistema de aquisição de dados constituído, basicamente, por um Conversor Analógico Digital (ADC) rápido, uma placa digital (I/O) convencional e um roteador construído no laboratório de Interações Hiperfinas (LIH) do IPEN. Este versátil e eficiente sistema, controlado por um software também criado no LIH em LabVIEW, permite a geração simultânea de 30 espectros de coincidências γ - γ atrasadas, número superior em comparação aos 12 espectros do antigo espectrômetro de quatro detectores. Além de medidas de linearidade, resolução em tempo e tempo morto, o funcionamento e o desempenho do espectrômetro foram comprovados através de medidas de CAP utilizando os núcleos de prova 111In -> 111Cd e 181Hf -> 181Ta, cujos resultados são bem conhecidos da literatura. Foram feitas medidas de interação quadrupolar do 181Ta em háfnio metálico e do 111Cd em cádmio metálico, e de campo hiperfino magnético do 111Cd e do 181Ta em níquel. Os resultados destas medidas se mostraram em concordância com a literatura. Adicionalmente foram realizadas medidas inéditas de interações hiperfinas magnéticas no composto intermetálico LaMnSi2 utilizando os núcleos de prova 111Cd e 140Ce. As medidas foram realizadas na faixa de temperatura de 10 K a 400K. No caso das medidas utilizando a sonda 111In -> 111Cd, os resultados mostram uma variação do campo magnético com a temperatura que segue a função de Brillouin. Já no caso das medidas com o núcleo de prova 140La -> 140Ce, o resultado apresentou um comportamento anômalo do campo hiperfino em função de temperatura. Os resultados evidenciam uma forte hibridização da banda 4f do Ce com a banda 3d do Mn, fato verificado e estudado em trabalhos anteriores com compostos semelhantes.

    Palavras-Chave: perturbed angular correlation; gamma-gamma logging; gamma spectrometers; fine structure; energy levels; nuclear structure; solid state physics; scintillation counters; radiation detectors; measuring instruments; nuclear materials management

  • IPEN-DOC 12016

    GENEZINI, FREDERICO A. ; DOMIENIKAN, CLAUDIO ; ZAHN, GUILHERME S. . Design of a gas efflent monitoring system for the sup(18)F production line. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: annihilation; coincidence circuits; coincidence spectrometry; cyclotrons; filters; fission product release; fluorine 18; gamma radiation; isotope production; monitoring; nuclear decay; radiation monitors

  • IPEN-DOC 19433

    DOMIENIKAN, CLAUDIO ; LAPOLLI, ANDRE L. ; SCHOUERI, ROBERTO M. ; MOREIRA, EDSON G. ; VASCONCELLOS, MARINA B.A. . Development and installation of an automatic sample changer for neutron activation analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: automation; brazilian cnen; computer codes; construction; design; electronic circuits; neutron activation analysis; sample changers

  • IPEN-DOC 17072

    DOMIENIKAN, CLAUDIO ; BRITO, ANDREIA; TOLEDO, FABIO de ; ZAHN, GUILHERME S. . Development of a digital log ratemeter. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: brazilian cnen; counting ratemeters; geiger-mueller counters; electronic circuits; computer codes

  • IPEN-DOC 18998

    ZAHN, GUILHERME S. ; DOMIENIKAN, CLAUDIO ; CARVALHÃES, ROBERTO P.M.; GENEZINI, FREDERICO A. . Development of a time-variable nuclear pulser for half life measurements. In: BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 35th, 2-6 de setembro, 2012, São Sebastião, SP. Proceedings... 2013.

    Palavras-Chave: half-life; isotopes; decay; pulse rise time; time measurement; computerized control systems

  • IPEN-DOC 15082

    LAPOLLI, ANDRE L. ; YAMAGISHI, SUELI; DOMIENIKAN, CLAUDIO ; SCHOUERI, ROBERTO M. ; CARBONARI, ARTUR W. ; SAXENA, RAJENDRA N. . Development of an object-oriented software based on fuzzy-logic for controlling temperatures in pac experiments. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: algorithms; data acquisition systems; data acquisition; furnaces; fuzzy logic; java; m codes; perturbed angular correlation; temperature control; temperature dependence; v codes

  • IPEN-DOC 17065

    DOMIENIKAN, CLAUDIO ; LAPOLLI, ANDRE L. ; TOLEDO, FABIO de ; ZANINI, AMELIA Y.K.; TRINDADE, GIVANILSON da S.. Electronic module for 6-BaFsub(2) - detectors positioning control. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: radiation detectors; barium fluorides; perturbed angular correlation; spectrometers; electronic circuits; control; motors; coincidence methods

  • IPEN-DOC 23305

    DOMIENIKAN, CLAUDIO ; BOSCH-SANTOS, BRIANNA ; PASCA, GABRIEL A.C. ; SAXENA, RAJENDRA ; CARBONARI, ARTUR . Hyperfine field at La in the intermetallic compound LaMnSi2 measured by PAC using 140Ce nuclear probe. In: TEMST, KRISTIAAN (Ed.); VANTOMME, ANDRE (Ed.); COTTENIER, STEFAAN (Ed.); PEREIRA, LINO (Ed.) INTERNATIONAL CONFERENCE ON HYPERFINE INTERACTIONS AND THEIR APPLICATIONS, July 3-8, 2016, Leuven, Belgium. Abstract... Leuven, Belgium: Instituut voor Kern- en Stralingsfysica, 2016.

    Abstract: Magnetic hyperfine field has been measured in the orthorhombic intermetallic compound LaMnSi2 with PAC spectroscopy using radioactive 140La-140Ce nuclear probes. Magnetization measurement was also carried out in this compound with MPSM-SQUID magnetometer. The LaMnSi2 sample was prepared by melting pure metallic components in stoichiometric proportions in an arc furnace under argon atmosphere. After melting, the sample was annealed at 1000 o C for 60h under helium atmosphere and then quenched in to water. X-ray analysis confirmed the sample to be in a single phase with correct crystal structure expected for LaMnSi2. The radioactive nuclei, 140La (T1/2 = 40h) were produced by direct irradiation of the sample with neutrons in the IEA-R1 nuclear research reactor at IPEN with a flux of ~1013 ncm-2s-1 for about 3-4 min. The irradiated sample was annealed at 1000 o C under helium atmosphere for 24 hours before starting the PAC measurement in order to minimize the effects of eventual radiation damage by fast neutrons during irradiation as well as to allow the decay of the short lived 56Mn (T1/2 = 2.6h) activity also produced in the sample. The PAC measurements were carried out with a six BaF2 detector spectrometer at several temperatures between 10 K and 400 K. The results showed well defined magnetic dipole interaction at all temperatures. Temperature dependence of the hyperfine field, Bhf was found to be anomalous. The magnetization measurement however, showed no anomaly. Therefore, the anomalous behavior of Bhf may be attributed to the interaction where 1f electron of the dilute Ce atom is spin polarized by the magnetic field from Mn sublattice and contributes to the effective hyperfine field. The ferromagnetic transition temperature (TC) of LaMnSi2 was determined to be 400(1) K confirming by magnetic measurement and the earlier results.

  • IPEN-DOC 22330

    DOMIENIKAN, CLAUDIO ; SANTOS, BRIANNA B. ; CABRERA PASCA, GABRIEL A. ; SAXENA, RAJENDRA N. ; CARBONARI, ARTUR W. . Hyperfine field at Mn in the intermetallic compound LaMnSi2 measured by PAC using sup(111)Cd nuclear probe. In: INTERNATIONAL CONFERENCE ON HYPERFINE INTERACTIONS AND SYMPOSIUM ON NUCLEAR QUADRUPOLE INTERACTIONS, September 21-26, 2014, Canberra, Australia. Abstract... 2014. p. 80.

    Palavras-Chave: manganese; intermetallic compounds; lanthanum compounds; manganese silicides; x-ray diffraction; cadmium 111; absorption spectroscopy; annealing; argon; atmospheres; barium fluorides; helium; indium 111; orthorhombic lattices; temperature dependence; thermal diffusion; transition temperature

  • IPEN-DOC 07000

    DOMIENIKAN, CLAUDIO . interface eletronica para aquisicao de 12 espectros de coincidencias gama-gama atrasadas. 2001. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 86 p. Orientador: Rajendra Narain Saxena.

    Palavras-Chave: gamma spectrometers; equipment interfaces; angular correlation; coincidence spectrometry; gamma spectra; electronic circuits; differential pac

  • IPEN-DOC 24095

    DOMIENIKAN, CLAUDIO ; COSTA, PRISCILA ; GENEZINI, FREDERICO A. ; ZAHN, GUILHERME S. . Low-cost amplifier for alpha detection with photodiode. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A low-cost amplifier for Hamamatsu S3590-09 PIN photodiode to be used in alfa detection is presented. This amplifier consists basically of two circuits: a pulse preamplifier and a shaper-driver. The PIN photodiode is reverse-biased and connected to a charge preamplifier input. Incident alpha particles generate a small current pulse in the photodiode. The integrating circuit of the low noise preamplifier transforms current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy pulse. The performance of the set photodiode-amplifier was successively tested through the use of a 243Am radioactive source. The low-cost photodiode amplifier was designed and constructed at IPEN - CNEN/SP using national components and expertise.

    Palavras-Chave: alpha detection; alpha spectrometers; americium 243; amplifiers; performance; photodiodes; brazilian cnen; radiation monitoring

  • IPEN-DOC 19314

    TOLEDO, FABIO de ; DOMIENIKAN, CLAUDIO ; ZAHN, GUILHERME S. . A new electronic circuit for nim rack power supply. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: nuclear instrument modules; power supplies; electronic circuits; brazilian cnen

  • IPEN-DOC 15078

    DOMIENIKAN, CLAUDIO ; LAPOLLI, ANDRE L. ; CARBONARI, ARTUR W. ; SAXENA, RAJENDRA N. ; SCHOUERI, ROBERTO M. . PAC spectrometer with six-baf sub(2)detectors. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: analog-to-digital converters; barium fluorides; coincidence spectrometry; data processing; experimental data; l codes; perturbed angular correlation; solid scintillation detectors; spectrometers

  • IPEN-DOC 18775

    DOMIENIKAN, CLAUDIO ; LAPOLLI, ANDRE L. ; SANTOS, BRIANNA B. dos; CARBONARI, ARTUR W. ; SAXENA, RAJENDRA N. ; SCHOUERI, ROBERTO M. . A six-BaFsub(2) detectors PAC spectrometer for measurements with short lived nuclear probes. In: JOINT INTERNATIONAL CONFERENCE ON HYPERFINE INTERACTIONS AND INTERNATIONAL SYMPOSIUM ON NUCLEAR QUADRUPOLE INTERACTION, 4RD, September 10-14, 2012, Beijing, China. Abstract... 2012.

    Palavras-Chave: analog-to-digital converters; barium fluorides; coincidence spectrometry; data processing; experimental data; l codes; perturbed angular correlation; solid scintillation detectors; spectrometers

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.