Navegação IPEN por assunto "barium 133"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 20422

    CORREA, EDUARDO L. ; KUAHARA, LILIAN T. ; POTIENS, MARIA da P.A. . Acceptance test of an activity meter to be used as reference in a calibration methodology establishment. In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4., August 26-29, 2014, Gramado, RS. Proceedings... 2014.

    Palavras-Chave: brazilian cnen; barium 133; cesium 137; cobalt 57; calibration; calibration standards; ionization chambers; nuclear medicine; quality control; testing

  • IPEN-DOC 28020

    CORREIA, RUANYTO W. . Análise da pureza radioativa de iodo-125 produzido no reator nuclear IEA-R1 pelo método de espectrometria gama e comparação com a exigência internacional / Analysis of radioactive purity of iodine-125 produced in the nuclear reactor IEA-R1 by the gamma spectrometry method and comparison with the international requirement . 2021. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 53 p. Orientador: Carlos Alberto Zeituni. DOI: 10.11606/D.85.2021.tde-14072021-104200

    Abstract: Com a finalidade de otimizar a produção, a irradiação e a quantificação de iodo-125 utilizado na confecção de sementes de iodo para braquiterapia, uma metodologia teórico-experimental foi aplicada baseada no procedimento proposto por COSTA, O. L., 2015, em que iodo-125 é obtido via ativação neutrônica no reator nuclear IEA-R1 a partir da irradiação de xenônio-124 encapsulado em compartimentos de alumínio. Após todo o preparo das amostras seguindo o processo descrito, iniciou-se o processo de irradiação sob o fluxo de nêutrons da ordem de 1013 nêutrons.cm-2.s-1 por diferentes períodos de tempo. Foram irradiadas seis cápsulas (duas contendo Xe-124 natural e quatro contendo Xe-124 enriquecido 99,9%) a fim de comparar a atividade total produzida variando o parâmetro de enriquecimento da amostra. Depois de serem irradiadas, as capsulas foram abertas e lavadas em meio alcalino aquecido para extração do iodo depositado nas paredes internas. As soluções geradas foram armazenadas em diferentes frascos padrões de acrílico, nomeadas e quantificadas via espectrometria gama com Detector de Germânio Hiperpuro (HPGe ORTEC modelo GEM-C5970-B) para determinação da pureza do radionuclídeo de interesse. Para calibração do HPGe foi aplicada uma metodologia experimental utilizando uma fonte de calibração certificada de bário-133 com atividade bem conhecida em que as eficiências dos fotopicos energéticos foram medidos entre 0 - 667 keV. As curvas de eficiência foram determinadas para uma faixa de energia que cobrissem toda a região de interesse espectral para o iodo-125 e seus subprodutos gerados na reação nuclear, além disso, elas foram construídas para diferentes distâncias da janela do detector e dimensões do frasco padrão de análise. No processo de ativação, iodo-126 foi formado como subproduto indesejado, esse radionuclídeo foi quantificado e sua atividade determinada. Finalmente, foi possível determinar a pureza radionuclídica do iodo-125 e compará-la com as exigências internacionais de qualidade que regulam a produção de medicamentos radioativos.

    Palavras-Chave: ge semiconductor detectors; gamma dosimetry; gamma spectroscopy; radiopharmaceuticals; iodine 125; iodine 126; xenon 124; barium 133; brachytherapy; radiotherapy; isotope ratio; isotope applications; isotope production reactors; iear-1 reactor; coefficient of performance; efficiency

  • IPEN-DOC 11674

    DIAS, MAURO S. ; TAKEDA, MAURO N.; KOSKINAS, MARINA F. . Application of Monte Carlo simulation to the prediction of extrapolation curves in the coincidence technique. Applied Radiation and Isotopes, v. 64, p. P. 1186-1192, 2006.

    Palavras-Chave: monte carlo method; simulation; extrapolation; coincidence methods; sulfur 35; cobalt 60; barium 133; standards

  • IPEN-DOC 26203

    BUENO, LETICIA K. ; MARTINS, ELAINE W. ; ABOLAFIO, ADILSON ; POTIENS, MARIA da P.A. . Behavior analysis of the activity meter in standard fields. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1156-1162.

    Abstract: The measurements good practices consists in the periodic control of the results obtained by the instruments, the main objective of the quality control in the activity meter is to guarantee that its response is being constant over time and, the results are trustable in relation to the references. The objective of this study was to perform a comparison of the behavior of 12 activity meters that are located inside of the IPEN’s Radiopharmacy Center. These equipment were submitted to periodic tests using the reference sources of 57Co, 133Ba and 137Cs. To evaluate their behavior the accuracy and precision tests were applied individually to the well-type ionization chamber. Based on the survey accomplished, we can verify through the failures presented on the accuracy performance that the activity meters are instruments that need a periodic verification, requesting adjusts and recalibration.

    Palavras-Chave: activity meters; barium 133; brazilian cnen; cesium 137; cobalt 57; comparative evaluations; ionization chambers; nuclear medicine; quality control

  • IPEN-DOC 27921

    SUZART, K.F. ; VELO, A.F. ; HAMADA, M.M. ; PEREIRA, M.C.C. ; MESQUITA, C.H. . Characterization of the CsI(Tl) crystalline scintillating detector produced at IPEN. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-13, 2021. DOI: 10.15392/bjrs.v9i1A.1586

    Abstract: Cesium iodide crystal activated with thallium (CsI(Tl)) is used as radiation sensor because of its favorable characteristics as scintillator, when excited by gamma radiation. This crystal has good mechanical strength and it is relatively little hygroscopic. In the present work, the CsI(Tl) crystal was grown in the Nuclear Energy Research Institute (IPEN/CNEN/SP) by Brigdman technique, in two different formats: (a) cylindric (∅ 20.1 mm x ↑ 11.9 mm) and (b) parallelepiped (12.3 mm x ↑ 19.5 mm). The scintillator spectrometry was studied through five gamma radiation sources: 99mTc (140 keV), 133Ba (355 keV) 22Na (511 keV) and 137Cs (662 keV). The crystals were coupled to a photomultiplier tube using 0.5 McStokes viscosity silicone grease as the optical interface. All electronics for signal measurements were developed at IPEN. Luminescence property of the CsI(Tl) crystal was excited by the radiation from a 137Cs source. The energy resolution of the crystalline detector was determined by the FWHM parameter, corresponding to the photopeak width at half of its height.

    Palavras-Chave: barium 133; cesium 137; sodium 22; technetium 99; thallium; iodides; crystals; luminescence; radiation detectors

  • IPEN-DOC 14883

    KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; BESSA, ANA C.M.; CALDAS, LINDA V.E. ; DIAS, MAURO S. . Comparative measurements in dose calibrators and a gamma-ray spectrometer. Applied Radiation and Isotopes, v. 68, n. 4-5, p. 589-591, 2010.

    Palavras-Chave: americium 241; barium 133; calibration; chromium 51; cobalt 60; europium 152; gallium 67; gamma spectrometers; high-purity ge detectors; nuclear medicine; radiation doses; standards; technetium 99; thallium 201

  • IPEN-DOC 06584

    COSTA, A.M.; CALDAS, L.V.E. . Desempenho de curiometros utilizados em Servicos de Medicina Nuclear. In: 7o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 31 de agosto - 3 de setembro, 1999, Belo Horizonte, MG. 1999.

    Palavras-Chave: quality control; activity levels; ionization chambers; geiger-mueller counters; cobalt 57; barium 133; cesium 137; performance testing; comparative evaluations

  • IPEN-DOC 21736

    TIEZZI, RODRIGO . Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em medicina nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicine . 2016. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 66 p. Orientador: Maria Elisa Chuery Martins Rostelato. DOI: 10.11606/D.85.2016.tde-07032016-140958

    Abstract: As fontes radioativas seladas são usadas na verificação de detectores de câmara de ionização, os quais medem a atividade dos radioisótopos usados nas mais diversas áreas, como na Medicina Nuclear. A medida da atividade dos radioisótopos deve ser feita com exatidão, pois será administrada em um paciente. Para garantir o adequado funcionamento dos detectores de câmara de ionização, são estipulados ensaios normatizados pela Agência Internacional de Energia Atômica (IAEA) e a Comissão Nacional de Energia Nuclear (CNEN) utilizando-se fontes radioativas seladas de Bário-133, Césio-137 e Cobalto-57. Os testes avaliam a exatidão, precisão, reprodutibilidade e linearidade da resposta do equipamento. O foco deste trabalho foi o estudo e o desenvolvimento dessas fontes radioativas padrão de Bário-133, Césio-137 e Cobalto-57, utilizando um polímero, no caso resina epóxi comerciais do tipo éter diglicidílico do bisfenol A e um agente de cura a base de poliamina modificada da dietilenotriamina ,para imobilizar o material radioativo. A matriz polimérica apresenta a função primordial de fixar e imobilizar o conteúdo radioativo não permitindo seu vazamento dentro dos limites técnicos exigidos pelas normas de proteção radiológica no quesito de características de uma fonte selada e, adicionalmente, ter a capacidade de reter a emanação de quaisquer gases que venham a se formar durante o processo de fabricação e do período de vida útil deste artefato. O processo de manufatura de uma fonte selada padrão consiste no envasamento, em um frasco de geometria padronizada, de uma quantidade, em volume fixo, de uma matriz polimérica no interior da qual é adicionada e dispersada homogeneamente uma quantidade precisa e exata em atividade de um material radioativo padrão. Nesse sentido, realizou-se um estudo para a escolha da resina epóxi, analisando suas características e propriedades. Foram realizados estudos e testes, verificando a máxima miscibilidade da resina com a água (solução ácida, simulando as condições da solução radiativa), perdas de propriedades mecânicas e térmicas, bem como o controle de dose radioativa para a completa cura (irradiadores de cobalto).Foram produzidas fontes de césio-137 e bário-133, realizou-se testes para determinação do grau de homogeneidade na dispersão do material radioativo na matriz e testes de imersão das fontes seladas produzidas para verificar a estanqueidade do sistema desenvolvido, obtendo um resultado satisfatório de acordo com as normas. Analisando todos os resultados obtidos, as fontes seladas podem ser confeccionadas em matriz epóxi DGEBA e endurecedor poliamínico DETA modificado, desde que a quantidade de material radioativo, na forma de solução ácida, adicionado à composição não ultrapasse um teor de 20%. A cura da resina epóxi pode ser melhorada em relação a ambiente, com uso da irradiação desde que seja exposta a uma dose ao redor de 33 kGy durante a cura. Nos testes de estanqueidade, verificou-se que as fontes são estanques, as medições da atividade da água utilizada nos testes mostraram um valor inferior a 185 Bq (de acordo com a International Standard Organization- Radiation protection sealed radioactive sources - ISO 9978), comprovando a eficiência da resina epóxi como material para selar o material radioativo. Tendo a finalidade de criar uma tecnologia nacional capaz de suprir a demanda deste produto no mercado interno e atingir excelência em qualidade através da acreditação e certificação do produto junto aos órgãos competentes.

    Palavras-Chave: nuclear medicine; diagnosis; ionization chambers; sealed sources; resins; polymerization; standard model; barium 133; cesium 137; cobalt 57; mechanical properties; thermodynamic properties; radiation dose units; radiation monitoring; comparative evaluations; radiation detectors

  • IPEN-DOC 10918

    YAMAZAKI, I.M. ; KOSKINAS, M.F. ; DIAS, M.S. ; ANDRADE e SILVA, L.G. ; VIEIRA, J.M. . Desenvolvimento de fontes radioativas solidas em resina acrilamida. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 9., 26-29 set, 2004, Rio de Janeiro, RJ. Anais... 2004.

    Palavras-Chave: resins; acrylamide; barium 133; polymerization; cobalt 60; radioactive materials; density; atomic number

  • IPEN-DOC 22098

    SILVA, THIAGO R. da ; TOBIAS, CARMEN C.B. . Detecção e espectrometria de elétrons de conversão interna com diodos de Si. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 13.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 4., 29-30 de agosto, 2007, São Paulo, SP. Resumo expandido... 2007.

    Palavras-Chave: detection; electron spectroscopy; internal conversion; silicon diodes; cobalt 57; cadmium 109; barium 133

  • IPEN-DOC 17358

    MESQUITA, C.H. ; DANTAS, C.R.; COSTA, F.E. ; CARVALHO, D.V.S.; MADI FILHO, T. ; VASQUEZ, P.A.S. ; HAMADA, M.M. . Development of a fourth generation industrial tomography for multiphase systems analysis. In: IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, October 30 - November 6, 2010, Knoxville, Tenn.. Proceedings... 2010. p. 19-22. DOI: 10.1109/nssmic.2010.5873710

    Palavras-Chave: computerized tomography; industrial radiography; distillation equipment; radiation detectors; cylindrical configuration; cesium 137; barium 133; iridium 192; multiphase flow; real time systems

  • IPEN-DOC 12044

    HAMADA, MARGARIDA M. ; MADI FILHO, TUFIC ; OLIVEIRA, ICIMONE B.. Development of a gamma and neutron detector using the TlBr crystal. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: barium 133; cesium 137; experimental data; gamma radiation; neutron detectors; resolution; semiconductor detectors; sodium 22; thallium bromides

  • IPEN-DOC 19475

    BENEGA, MARCOS A.G.; NAGATOMI, HELIO R.; ROSTELATO, MARIA E.C.M. ; KARAN JUNIOR, DIB; PELEIAS JUNIOR, FERNANDO S.; SOUZA, CARLA D.; TIEZZI, RODRIGO; RODRIGUES, BRUNA T.. Development of radioactive sealed sources in epoxy matrix. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: sealed sources; barium 133; cesium 137; cobalt 57; radiation detectors; solidification; vitrification; epoxides

  • IPEN-DOC 22357

    BENEGA, MARCOS A.G. ; NAGATOMI, HELIO R. ; ROSTELATO, MARIA E.C.M. ; PELEIAS JUNIOR, FERNANDO S. ; TIEZZI, RODRIGO ; SOUZA, CARLA D. ; RODRIGUES, BRUNA T. ; KARAN JUNIOR, DIB. Development of radioactive sources fixated in epoxy matrix to verificate nuclear medicine equipments. In: EUROPEAN NUCLEAR CONFERENCE 2014, May 11-14, 2014, Marseille, France. Proceedings... 2014. p. 44-50.

    Palavras-Chave: barium 133; cesium 137; cobalt 57; epoxides; gy range 10-100; irradiation; nuclear medicine; radiation detectors; radiation doses; resins; sealed sources; solutions

  • IPEN-DOC 12002

    VIEIRA, CELSO L.; COSTA, FABIO E. da ; HAMADA, MARGARIDA M. . Effect of etching on the TlBr crystal surface and its radiation response. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: americium 241; americium; barium 133; barium; bromine; dielectric track detectors; etching; gamma radiation; gamma sources; photons; radiation detectors; thallium

  • IPEN-DOC 15084

    ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. ; MORALLES, MAURICIO . Evaluation of peak-fitting software for gamma spectrum analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: barium 133; calibration standards; cesium 137; cobalt 60; comparative evaluations; europium 152; experimental data; gamma sources; gamma spectra; gamma spectroscopy; gauss function; p codes; peaks

  • IPEN-DOC 13512

    NISTI, M.B. ; SANTOS, A.J.G. ; PECEQUILO, B.R.S. ; MADUAR, M.F. ; ALENCAR, M.M. ; DAMATTO, S.R. . Fast methodology for time counting optimization in gamma-ray spectrometry based on preset minimum detectable amounts. In: INTERNATIONAL CONFERENCE ON NUCLEAR ANALYTICAL METHODS IN THE LIFE SCIENCES, 9th, September 7-12, 2008, Lisbon, Portugal. Abstract... 2008.

    Palavras-Chave: barium 133; cesium 134; cobalt 60; gamma spectroscopy; high-purity ge detectors; ruthenium 106; zinc 65

  • IPEN-DOC 14516

    NISTI, M.B. ; SANTOS, A.J.G. ; PECEQUILO, B.R.S. ; MADUAR, M.F. ; ALENCAR, M.M. ; MOREIRA, S.R.D. . Fast methodology for time counting optimization in gamma-ray spectrometry based on prest minimum detectable amounts. Journal of Radioanalytical and Nuclear Chemistry, v. 281, n. 2, p. 283-286, 2009.

    Palavras-Chave: barium 133; cesium 134; ruthenium 106; zinc 65; gamma spectroscopy; high-purity ge detectors

  • IPEN-DOC 10683

    BUENO, C.C. ; GONCALVES, J.A.C. ; CAMARGO, F.; PINTO, J.K.. Full energy peak efficiency of a rad-hard silicon diode for X- and gamma-rays. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: americium 241; barium 133; cobalt 57; efficiency; energy dependence; gamma spectroscopy; peaks; radiation sources; silicon diodes; x-ray spectroscopy

  • IPEN-DOC 10755

    OLIVEIRA, I.B.; COSTA, F.E. ; HAMADA, M.M. . Gamma-ray spectroscopy for TlBr detectors at two different temperatures. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: americium 241; barium 133; bridgman method; cobalt 57; crystal growth; energy resolution; experimental data; gamma spectroscopy; performance; semiconductor detectors; stability; temperature dependence; thallium bromides

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.