  • IPEN-DOC 03265

    KOSKINAS, MARINA F. . Desenvolvimento de um sistema de coincidencia para a medida absoluta da atividade de radionuclideos empregando detectores de barreira de superficie. 1988. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 140 p. Orientador: Laercio Antonio Vinhas.

    Palavras-Chave: radioisotopes; coincidence methods; absolute counting; surface barrier detectors; standardization; alpha detection; americium 241; cadmium 109; cesium 137; efficiency; gamma detection; k capture; proportional counters; radioactivity; spontaneous fission radioisotopes; x-ray detection; measuring instruments

  • IPEN-DOC 22098

    SILVA, THIAGO R. da ; TOBIAS, CARMEN C.B. . Detecção e espectrometria de elétrons de conversão interna com diodos de Si. In: PROGRAMA INSTITUCIONAL DE BOLSAS DE INICIAÇÃO CIENTÍFICA, 13.; PROGRAMA DE BOLSAS E INICIAÇÃO CIENTÍFICA CNEN, 4., 29-30 de agosto, 2007, São Paulo, SP. Resumo expandido... 2007.

    Palavras-Chave: detection; electron spectroscopy; internal conversion; silicon diodes; cobalt 57; cadmium 109; barium 133

  • IPEN-DOC 01783

    KOSKINAS, M.F. ; DIAS, M.S. . Determinacao da taxa de desintegracao do Cd-109 por coincidencia 2pi(BS)e sup (-)-x. In: 13a. REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 2-6 de setembro, 1990, Caxambu, MG. Resumo... 1990.

    Palavras-Chave: cadmium 109; decomposition; coincidence methods

  • IPEN-DOC 06867

    LANDINI, LILIANE . Estudo da producao de sup(57)Co e sup(109)Cd em ciclotron. 2000. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 112 p. Orientador: Joao Alberto Osso Junior.

    Palavras-Chave: cobalt 57; cadmium 109; isotope production; nickel; irradiation; proton beams; cyclotrons; parametric analysis; ion exchange chromatography; nickel

  • IEA-PUB-330

    GARCIA AGUDO, E. ; SANTOS, M.E.. Fluorescencia de raios X por excitacao radioisotopica: uma promissora tecnica de analise. 1974. p.

    Palavras-Chave: cadmium 109; copper; minerals; on-line measurement systems; ore processing; prospecting; quantitative chemical analysis; x-ray fluorescence analysis

  • IPEN-DOC 12003

    SILVA, THIAGO R.; CAMARGO, FABIO de; GONCALVES, JOSEMARY A.C. ; FRAGA, MARGARIDA R.F.; BUENO, CARMEN C. . Low-energy internal conversion electrons spectrometry with a silicon diode. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: barium 133; barium; cadmium 109; cadmium; cobalt 57; cobalt; energy levels; gamma decay; internal conversion radioisotopes; internal conversion; junction diodes; photodiodes; phototransistors; self-absorption; silicon diodes; spectroscopy

  • IPEN-DOC 02695

    OSSO JUNIOR, J.A. . Producao de fontes de calibracao e/ ou tracadores radioativos com o ciclotron CV-28. In: 3o. ENCONTRO NACIONAL DE APLICAOES NUCLEARES, 7-11 de agosto, 1995, Aguas de Lindoia, SP. 1995. p. 1034-1036.

    Palavras-Chave: accelerators; isotope production; calibration; tracer techniques; cobalt 57; cadmium 109; indium 111

  • IPEN-DOC 24683

    OSSO JUNIOR, J.A. ; LANDINI, L. ; LION, L.F. ; MORAES, V. . Production of 57Co, 109Cd, 111In and 117mSn using CV-28 cyclotron at IPEN-CNEN/SP. In: INTERNATIONAL SYMPOSIUM ON UTILIZATION OF ACCELERATORS, November 26-30, 2001, São Paulo, SP. Abstract... Vienna, Austria: International Atomic Energy Agency (IAEA), 2001. p. 53-54.

    Observação: Report Number IAEA-SM-366/119

    Abstract: Several radioisotopes produced in Cyclotrons have physical properties of decay suitable to be used as: radiopharmaceuticals, for in vivo Diagnosis images (with the techniques of SPET and PET, Single Photon Emission Tomography and Positron Emission Tomography, respectively) and for Therapy, in Nuclear Medicine; calibration sources of several instruments applied in the nuclear area and in Metrology; and as radioactive tracers of elements investigated in many fields, such as Chemistry, Physics and Biology. This work describes the production of four of these radioisotopes that are very important in these areas: 57Co, 109Cd, 111ln and 117mSn. They can be obtained using the CV-28 Cyclotron at IPEN, because it can accelerate proton beams with energies up to 24MeV and currents up to 20μA (external). 57Co (t1/2=271.3 d) decays by electron capture to 57Fe with the emission of γ-rays and one characteristic X-ray. It is widely used as calibration source of detectors such as: Ge(Li), Ge(HP), Nal(TI) and dose calibrators (well type detectors). Besides these applications, 57Co Flood Sources are used to test the response uniformity of gamma cameras, in Nuclear Medicine. 109Cd has a half-life of 462.6 d and decays by electron capture to 109Ag with the emission of one γ-ray and one characteristic X-ray. This radioisotope can be employed as calibration source of X-ray and γ-rays detectors; as a radioactive tracer of Cd, an environment pollutant and used in the EDXRF (Energy Dispersion X-Ray Fluorescence) technique. 57Co was produced through the irradiation of natNi. Thick target yields for 55Co, 56Co, 57Co, 58CO, 56Ni and 57Ni were measured and the mean values were 346.69kBq/μA.h (9.37μCi/μA.h), for the direct production of 57Co and 150.59kBq/μA.h (4.07μCi/μA.h), through the decay of 57Ni (11.31 days after EOB - End of Bombardment). A solution of 57CoCl2 was prepared, to fill a flood source for calibration of gamma camera, with activity of 222MBq (6mCi) of 57Co and impurity levels of 1.13 and 1.29% for 56Co and 58Co, respectively, at delivery time. In order to achieve these results, a chemical separation method was developed with a separation yield of 93% for 5'7Co and a negligible loss of Ni. A composite target of Ni and Ag was prepared and a chemical separation method proposed to allow the separation between the targets and the products of interest, 57Co and 109Cd. The yields obtained in the irradiation of the composite target were: 947.94kBq/μA.h (25.62μCi/μA.h) of 57Co - direct reaction, 259-00kBq/μA.h (7μCi/μA.h) of 57Co - indirect reaction (11.31 days after EOB) and 71.41kBq/μA.h (1.93μCi/μA.h) of 109Cd, which showed the efficiency of its use, as well as the chemical separation, with a yield of 80% for 57Co and 109Cd. 111ln (t1/2=67.5 h) has appropriate characteristics for Diagnosis in Nuclear Medicine due to its decay mode (100% by electron capture) and its adequate half-life to slow biological studies, that makes it one of radioisotopes of interest of Brazilian Physicians. It can also be used in angular correlation studies in Nuclear Physics. 111In was produced by the 112Cd(p,2n)111ln reaction, that has the highest yield. The Cd targets were prepared by electroplating of CdSO4 solution in copper and copper/nickel backings. After being irradiated, a chemical separation was performed by an acetic acid extraction method, with an overall recovery yield for 111ln higher than 95%. The level of the chemical impurities of Cd, Ni and Cu were bellow than the permissible values. 117mSn (t1/2=14 d) has suitable characteristics of decay to be used as a tracer of SnCl2 in the labeling of organic molecules with 99mTc and also in radiotherapeutical applications. It was prepared by the irradiation of natural tin through the nuclear reactions natSn(p,xn)117Sb→117mSn. The production thick target yield of 117mSnnn was 784.4kBq/μA.h (21.20μCi/μA.h) and with the proper decay time of its precursor, 117Sb, no radionuclidic impurities appeared in the final product. A chemical separation method was developed to separate first 117Sb from the irradiated Tin and then 117mSn from Sb with a good chemical yield. The quality control procedures showed the good quality of the final product, 117mSn.

    Palavras-Chave: cyclotrons; cobalt 57; cadmium 109; indium 111; tin 117; radioisotopes

  • IPEN-DOC 10253

    BUENO, C.C. ; GONCALVES, J.A.C. ; MAGALHAES, R.R.; SANTOS, M.D.S.. Response of PIN diodes as room temperature photon detectors. Applied Radiation and Isotopes, v. 61, n. 6, p. 1343-1347, 2004.

    Palavras-Chave: x-ray spectroscopy; silicon diodes; radiation detectors; cadmium 109; barium 133; europium 152; americium 241; photodiodes

  • IPEN-DOC 04433

    MENGATTI, J. ; SGAMBATTI, E.M.; SUMIYA, J.B.; SCIANI, V. ; OSSO JUNIOR, J.A. . Separacao quimica do cadmio-109 da prata irradiada com protons em ciclotron. In: 4o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 5-9 de julho, 1992, Rio de Janeiro, RJ. 1992. p. 145-146.

    Palavras-Chave: cadmium 109; silver; separation processes

  • IPEN-DOC 08257

    LANDINI, L. ; OSSO JUNIOR, J.A. . Simultaneous production of sup(57)Co and sup(109)Cd in cyclotron. Journal of Radioanalytical and Nuclear Chemistry, v. 250, n. 3, p. 429-431, 2001.

    Palavras-Chave: radioisotopes; cobalt 57; cadmium 109; isotope production; cyclotrons; nickel; silver; targets; reduction; ion exchange

  • IPEN-DOC 10470

    PEIXOTO, T.P.; PASCHOLATI, P.R.; VANIN, V.R.; BUENO, C.C. ; GONCALVES, J.A.C. . Two-parameter analysis of the temporal behaviour of resistive detectors. Brazilian Journal of Physics, v. 34, n. 3A, p. 1029-1032, 2004.

    Palavras-Chave: computer codes; data acquisition systems; decay; two-dimensional calculations; radiation detectors; cadmium 109

  • IPEN-DOC 09232

    PEIXOTO, T.P.; PASCHOLATI, P.R.; GONCALVES, J.A.C. ; BUENO, C.C. ; VANIN, V.R.. Two-parameter analysis of the temporal behaviour of resistive detectors. In: LATINAMERICAN SYMPOSIUM ON NUCLEAR PHYSICS, 5th; REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 26, Sept. 1-5, 2003, Santos, SP. Abstracts... 2003. p. 44.

    Palavras-Chave: computer codes; data acquisition systems; decay; two-dimensional calculations; radiation detectors; cadmium 109

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.