  • IPEN-DOC 04181

    TOIVONEN, M.; JARVINEN, H.; CAMPOS, L.L. ; LAS, W. . Air kerma intercomparison at sup(60)Co by solid Tl detectors. Radiation Protection Dosimetry, v. 34, n. 14, p. 249-251, 1990.

    Palavras-Chave: cobalt 60; thermoluminescent dosemeters; kerma; air; radiation detectors

  • IPEN-DOC 24057

    FONTES, LADYJANE P. ; POTIENS, MARIA da P.A. . Application of the correction factor for radiation quality Kq in dosimetry with pencil-type ionization chambers using a tandem system. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The pencil-type ionization chamber widely used in computed tomography (CT) dosimetry, is a measuring instrument that has a cylindrical shape and provides uniform response independent of the angle of incidence of ionizing radiation. Calibration and measurements performed with the pencil-type ionization chamber are done in terms of Kerma product in air-length (Pk,l) and values are given in Gy.cm. To obtain the values of (Pk,l) during clinical measurements, the readings performed with the ionization chamber are multiplied by the calibration coefficient (Nk,l) and the correction factor C for quality (Kq) which are given in Calibration certificates of the chambers. The application of the correction factor for radiation quality Kq is done as a function of the effective energy of the beam that is determined by the Half Value layer (HVL) calculation. In order to estimate the HVL values in this work, a Tandem system made up of cylindrical aluminum and PMMA absorber layers was used as a low cost and easy to apply method. From the Tandem curve, it was possible to construct the calibration curve and obtain the appropriate Kq to the beam of the computed tomography equipment studied.

    Palavras-Chave: calibration; computerized tomography; corrections; dosimetry; ionization chambers; kerma; layers; pmma; quality assurance

  • IPEN-DOC 23961

    SILVA, J.O. ; CALDAS, L.V.E. . Assessment of dosimetric parameters in mammography employing a homemade ionization chamber / Estimativa de parâmetros dosimétricos em mamografia utilizando uma câmara de ionização caseira. Scientia Plena, v. 12, n. 12, p. 1-11, 2016. DOI: 10.14808/sci.plena.2016.124101

    Abstract: X-ray mammography examination is the reference tool to discover breast cancer in an early stage. The mammography unit must follow an accurate quality control program that covers both patient and staff radiation protection. Plane parallel ionization chambers are the reference instrument for dosimetry in mammography beams, but they can represent higher cost for small clinics in countries as Brazil. In this work, it is presented a low cost ionization chamber for mammography X-rays energy range dosimetry developed at IPEN. The homemade ionization chamber has a sensitive volume of 6.0 cm3 and it was utilized to execute quality control tests in two distinct mammography systems: a GE Senographe DMR-plus and a Philips VMI Graph Mammo. The setups for the tests performed agreed with the IAEA HHS 2 and 17 recommendations. A breast phantom of various PMMA thicknesses was utilized in this work. The homemade ionization chamber performance was compared to that of a commercial one. The maximum difference between the incident air kerma measured with the reference ionization chamber and the developed one was only 5.62% for the GE equipment and only 4.42% for the Philips equipment. The homemade ionization chamber presented an excellent performance in incident air kerma and HVL measurements for the radiographic techniques utilized in the present work. All the results obtained were within IAEA specifications.

    Palavras-Chave: x-ray radiography; mammary glands; ionization chambers; radiation doses; glands; beams; kerma; dosimetry

  • IPEN-DOC 20607

    BATISTA, WILSON O.; SOARES, MARIA R.; OLIVEIRA, MARCUS V.L. de; MAIA, ANA F.; CALDAS, LINDA V.E. . Assessment of protocols in CBCT with symmetric and asymmetric beam using effective dose and Psub(KA). In: INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY , 14th, April 13-16, 2014, Cusco, Peru. Proceedings... 2014. p. 423-432.

    Palavras-Chave: dentistry; radiology; cat scanning; kerma; symmetry; images; jaw; phantoms; radiation doses; dose equivalents

  • IPEN-DOC 20826

    BATISTA, WILSON O.; SOARES, MARIA R.; OLIVEIRA, MARCUS V.L. de; MAIA, ANA F.; CALDAS, LINDA V.E. . Assessment of protocols in CT with symmetric and asymmetric beans usingeffective dose and air kerma-area product. Applied Radiation and Isotopes, v. 100, p. 16-20, 2015.

    Palavras-Chave: dentistry; radiology; kerma; symmetry; images; cones; computerized tomography; radiation doses; thermoluminescent dosimetry; radiation protection

  • IPEN-DOC 10630

    ALVAREZ, O.T.B.; CALDAS, L.V.E. . Avaliacao do desempenho de dos modelos de camaras poco utilizados em braquiterapia LDR. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: air; brachytherapy; calibration standards; cesium 137; cobalt 57; experimental data; ionization chambers; kerma; low dose irradiation; performance testing; radiation sources; technetium 99

  • IPEN-DOC 10701

    MIRANDA, J.A.; POTIENS, M.P.A. . Avaliacao dos valores de taxa de kerma no ar dos sistemas de radiacao X utilizados na calibracao de intrumentos de medida em radiodiagnostico. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: air; calibration standards; calibration; ionization chambers; kerma; quality assurance; radiation doses; radiation protection; radiation quality; x-ray equipment

  • IPEN-DOC 23195

    SANTOS, W.S. ; NEVES, L.P.; PERINI, A.P.; BELINATO, W.; MAIA, A.F.; CALDAS, L.V.E. . Avaliação das exposições dos envolvidos em procedimentos intervencionistas usando método Monte Carlo. Brazilian Journal of Radiation Sciences, v. 5, n. 1, p. 01-06, 2017.

    Abstract: Neste estudo apresenta-se um modelo computacional de exposição de um paciente, médico cardiologista e de uma enfermeira em um cenário típico de procedimentos intervencionistas cardíacos. Neste caso, foi calculado um conjunto de coeficientes de conversão (CC) para dose efetiva (E) em termos do produto kerma-área (PKA) para os indivíduos envolvidos, utilizando sete espectros energéticos diferentes e oito projeções de feixe. Também foi calculado o CC para dose de entrada na pele (DEP) do paciente normalizado pelo PKA. Todos os indivíduos foram representados por simuladores antropomórficos computacionais incorporados em um código de transporte de radiação baseado em simulação de Monte Carlo.

    Palavras-Chave: air; conversion; dosimetry; kerma; monte carlo method; occupational exposure; patients; phantoms; radiation doses; radiation protection; radiology; radiological personnel

  • IPEN-DOC 11519

    SOARES, FERNANDA C.S. . Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2006.tde-16052012-103302

    Abstract: Neste trabalho foram avaliados aventais de proteção e blindagens de ovário de cinco fabricantes segundo as normas NBR / IEC 61331-1 e NBR / IEC 61331-3 de 2004. Para a determinação da espessura equivalente de atenuação foram aplicadas três metodologias diferentes (interpolação linear, modelo de Archer e somatório de exponenciais), uma vez que a norma não indica como este valor deve ser obtido. Além disso, foram estimadas as incertezas associadas a cada método e a influência do número de medições na incerteza combinada. As características de confecção avaliadas foram: documento acompanhante, projeto, materiais, dimensões e marcação da etiqueta. Para esta avaliação foi elaborado um formulário que contemplava todas as exigências da NBR / IEC 61331-3. Os resultados mostraram uma grande diferença entre os valores de espessura equivalente de atenuação declarados e medidos. A comparação dos resultados das três metodologias aplicadas mostrou que há pouca variação entre os valores obtidos e entre as incertezas associadas nas diferentes metodologias. Foi possível observar também que o número de medições não contribui significativamente para o aumento da incerteza nas três metodologias. A metodologia que melhor se adequou à rotina do laboratório foi a metodologia da interpolação linear com cinco medições da taxa de kerma no ar. A discrepância entre os resultados apresentados neste trabalho e as exigências das normas estudadas mostra a necessidade de tornar compulsória a certificação dos dispositivos de proteção, contribuindo assim para o aumento da proteção radiológica do usuário.

    Palavras-Chave: attenuation; data covariances; experimental data; ionization chambers; kerma; protective clothing; radiation protection; radiation quality; safety standards; thickness; x-ray equipment

  • IPEN-DOC 20235

    COSTA, N.A. ; POTIENS, M.P.A. . Calibration methodology application of kerma area products meters in situ: Preliminary results. Radiation Physics and Chemistry, v. 104, p. 201-203, 2014.

    Palavras-Chave: calibration; kerma; meters; patients; dosemeters; equipment

  • IPEN-DOC 10439

    POTIENS, M.P.A. ; CALDAS, L.V.E. . Calibration methodology for instruments utilized in X radiation beams diagnostic level. In: INTERNATIONAL JOINT MEETING/CONGRESO INTERNACIONAL CONJUNTO, Jul. 11-14, 2004, Cancun, Quintana Roo, Mexico. Proceedings... 2004.

    Palavras-Chave: americium 241; calibration; diagrams; dosimetry; electric potential; experimental data; gamma radiation; high-purity ge detectors; ionization chambers; iso; kerma; measuring instruments; peaks; radiation protection; radiation quality; radiology; x radiation

  • IPEN-DOC 05717

    CALDAS, L.V.E. ; ALBUQUERQUE, M.P.P. . Calibration of clinical dosemeters in the IAEA water phantom. In: 4th CONFERENCE ON RADIATION PROTECTION AND DOSIMETRY, October 23-27, 1994, Orlando, Fla., USA. Abstract... 1994. p. 523.

    Palavras-Chave: dosemeters; calibration; water; calibration standards; cobalt 60; comparative evaluations; dosimetry; hospitals; kerma; radiation protection

  • IPEN-DOC 21410

    SILVA, NATALIA F. ; XAVIER, MARCOS ; VIVOLO, VITOR ; CALDAS, LINDA V.E. . Caracterização de uma camara de ionização de ar livre para baixas energias / Characterization of a free air ionization chamber for low energies. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 4 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: ionization chambers; kerma; x-ray sources; beams

  • IPEN-DOC 20340

    LIMA, MATEUS H. de . Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia / Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography . 2014. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 78 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2014.tde-02052014-152732

    Abstract: Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio.

    Palavras-Chave: mammary glands; biomedical radiography; x-ray sources; ionization chambers; kerma

  • IPEN-DOC 13365

    AFONSO, L.C.; VIVOLO, V. ; CALDAS, L.V.E. . Characteristics of a tandem system of ionization chambers in X-ray beams mammography level. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 7th, June 22-27, 2008, Praga, Republica Tcheca. Proceedings... 2008.

    Palavras-Chave: biomedical radiography; dosemeters; dosimetry; ionization chambers; kerma; mammary glands; quality control; x radiation; x-ray equipment

  • IPEN-DOC 23115

    SILVA, NATALIA F. DA ; XAVIER, M. ; VIVOLO, V. ; CALDAS, L.V.E. . Characterization of a free air ionization chamber for low energy X-rays. Journal of Physics: Conference Series, v. 733, p. 1-5, 2016. DOI: 10.1088/1742-6596/733/1/012090

    Abstract: Free air ionization chambers are used by most primary metrology laboratories as primary standards of the quantities air kerma and exposure in X-ray beams. The free air ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a characterization test a problem in the set responsible for the variation of its sensitive volume. After a modification in the support of the micrometers used for the movement of the internal cylinder and the establishment of a new alignment system protocol, the tests were redone. The objective of this work was to present the results obtained in the new condition.

    Palavras-Chave: calibration; ionization; standards; ionization chambers; air; alignment; cylinders; kerma; modifications; variations; x radiation

  • IPEN-DOC 05484

    CALDAS, L.V.E. ; ALBUQUERQUE, M.P.P. . Clinical dosemeters calibrated in terms of air kerma and absorbed dose to water. In: WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, August 21-26, 1994, Rio de Janeiro, RJ. p. 795... 1994. p. Abstract.

    Palavras-Chave: dosemeters; medical supplies; calibration; water; air; kerma

  • IPEN-DOC 23169

    GIMENEZ-ALVENTOSA, VINCENT; ANTUNES, PAULA C.G. ; VIJANDE, JAVIER; BALLESTER, FACUNDO; PEREZ-CALATAYUD, JOSE; ANDREO, PEDRO. Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy. Physics in Medicine & Biology, v. 62, n. 1, p. 146-164, 2017. DOI: 10.1088/1361-6560/aa4f6a

    Abstract: The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seeds is proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences. State-of-the art Monte Carlo calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone), which in all cases include a realistic modelling of low-energy brachytherapy sources in order to benchmark the formalism proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases (e.g. bone tissue).

    Palavras-Chave: absorbed radiation doses; accuracy; analytical solution; benchmarks; bone tissues; brachytherapy; charged particles; corrections; dosimetry; energy absorption; kerma; monte carlo method; muscles; radiation source implants; skeleton

  • IPEN-DOC 25257

    CABRAL, T.S.; SILVA, C.N.M. da; POTIENS, M.P.A. ; SOARES, C.M.A.; SILVEIRA, R.R.; KHOURY, H.; SAITO, V.; FERNANDES, E.; CARDOSO, W.F.; OLIVEIRA, H.P.S. de; PIRES, M.A.; AMORIM, A.S. de; BALTHAR, M.. Comparison for air kerma from radiation protection gamma-ray beams with brazilian network - 2016/2017. Journal of Physics: Conference Series, v. 975, p. 1-9, 2018. DOI: 10.1088/1742-6596/975/1/012042

    Abstract: The results of the comparison involving 9 laboratories in Brazil are reported. The measured quantity was the air kerma in 137Cs and 60Co, at the level of radioprotection. The comparison was conducted by the National Laboratory Metrology of Ionizing Radiation (LNMRI/IRD) from October 2016 to March 2017. The largest deviation between the calibration coefficients was 0.8% for 137Cs and 0.7% for 60Co. This proficiency exercise proved the technical capacity of the Brazilian calibration network in radiation monitors and the results were used by some in the implementation of the standard ISO/IEC 17025.

    Palavras-Chave: calibration standards; cesium 137; cobalt 60; gamma radiation; interlaboratory comparisons; ionization chambers; kerma; radiation monitors; radiation protection; brazilian cnen

  • IPEN-DOC 22367

    POTIENS JUNIOR, A.J. ; COSTA, N.A. ; SANTOS, L.R. ; CORREA, E.L.; VIVOLO, V. ; POTIENS, M.P.A. . Comparison of a KAP meter and a PDC behaviour using mathematical simulation in reference diagnostic radiology qualities. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 9th, July 6-11, 2014, Valencia, Espanha. Proceedings... 2014.

    Palavras-Chave: comparative evaluations; kerma; evaluation; measuring instruments; diagnosis; radiology; monte carlo method

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.