Navegação IPEN por assunto "laboratories"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 16537

    DANTAS, B.M.; DANTAS, A.L.A.; ACAR, M.E.D.; CARDOSO, J.C.S. ; JULIAO, L.M.Q.C.; LIMA, M.F. ; TADDEI, M.H.T.; ARINE, D.R.; ALONSO, T.; RAMOS, M.A.P.; FAJGELJ, A.. Accreditation and training on internal dosimetry in a laboratory network in Brazil: an increasing demand. Radiation Protection Dosimetry, v. 144, n. 1-4, p. 124-129, 2011.

    Palavras-Chave: brazil; laboratories; dosimetry; internal irradiation; monitoring; network analysis; training

  • IPEN-DOC 16161

    CAPORALE, GRACIANE M.M.; PEIXOTO, ZELIA M.P.; CHAVES, LUCIANA B.; CARRIERI, MARIA L.; SCHEFFER, KARIN C.; ACHKAR, SAMIRA M.; CARNIELI JUNIOR, PEDRO; SPENCER, PATRICK ; VASSAO, RUTH C.; SILVA, ANDREA de C.R. da. Advances in rabies laboratory diagnosis in Brazil. In: WILLIAMSON, JOHN G. (Ed.). Rabies: Symptoms, treatment and prevention. Nova Science Publishers: New York, USA, 2010. p. 65-79, (Virology Research Progress Series).

    Palavras-Chave: brazil; rabies; symptoms; laboratories; diagnosis; therapy; preventive medicine

  • IPEN-DOC 21714

    SARMENTO, D.M. ; RODRIGUES, D.L. ; SANCHES, M.P. ; CARNEIRO, J.C.G.G. . Ambient radiation levels in a microPET/CT research laboratory. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 2 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: thermoluminescent dosimetry; animals; radiation protection; evaluation; radiation monitoring; laboratories; computerized tomography; occupational exposure; positron computed tomography

  • IPEN-DOC 17203

    KIRITA, RODRIGO; CARVALHO, DIEGO V. de S.; MESQUITA, CARLOS H. de ; VASQUEZ, PABLO A.S. ; HAMADA, MARGARIDA M. . Analysis of an industrial process simulator column using third-generation computed tomography. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: brazilian cnen; laboratories; computerized tomography; simulators; industrial plants; gamma radiation

  • IPEN-DOC 19117

    PUERTA, DANIEL C. . Aplicação do método ksub(0)-INAA no Laboratório de Análise por Ativação com Nêutrons do IPEN utilizando o programa ksub(0)-IAEA. Análise de amostras biológicas / ksub(0)-INAA application at IPEN Neutron Activation Laboratory by using the ksub(0)-IAEA program. Biological sample analysis . 2013. Dissertação (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 190 p. Orientador: Ana Maria Graciano Figueiredo. DOI: 10.11606/D.85.2013.tde-22082013-143640

    Abstract: Este estudo apresenta os resultados obtidos na aplicação do método de padronização k0-INAA no LANIPEN, para a análise de amostras biológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). Os parâmetros de fluxo f e α do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação e na posição de irradiação 24B/prateleira2, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr- 94Zr. Para a verificação da precisão e exatidão do método, foram analisados os materiais biológicos de referência Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a). Os critérios estatísticos Erro Relativo (bias, %), Coeficiente de Variação (CV) e U-score foram aplicados para avaliação dos resultados obtidos (média de seis replicatas). Os erros relativos (bias, %) ficaram, para maioria dos elementos, entre 0 e 30%, em relação aos valores certificados. Os Coeficientes de Variação foram inferiores a 20%, mostrando boa reprodutibilidade nos resultados obtidos experimentalmente. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Na no Peach Leaves e no Tomato Leaves, estão dentro de um intervalo de confiança de 95%. Estes resultados apontam para uma promissora utilização do método k0-INAA no LAN-IPEN para a análise de amostras biológicas.

    Palavras-Chave: brazilian cnen; laboratories; biological materials; standardization; sample preparation; neutron activation analysis; programming

  • IPEN-DOC 19262

    PUERTA, DANIEL C.; FIGUEIREDO, ANA M.G. ; SEMMLER, RENATO ; JACIMOVIC, RODOJKO. Application of the ksub(0)-INAA method for analysis of biological samples at the pneumatic station of the IEA-R1 nuclear research reactor. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: brazilian cnen; laboratories; biological materials; standardization; sample preparation; neutron activation analysis; programming

  • IPEN-DOC 09308

    MAIA, FRANCISCO J. de O. . Aspectos da gestao ambiental em empresas que utilizam analises de agua. 2003. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 108 p. Orientador: Maria Beatriz Bohrer-Morel. Coorientador: Isak Kruglianskas.

    Palavras-Chave: industry; management; environment; monitoring; water; cooperation; laboratories; chemical analysis; quality assurance

  • IPEN-DOC 13602

    LAINETTI, P.E. de O. . Aspectos reguladores de um projeto de descomissionamento no Brasil - Ex. Laboratorio de Caracterizacao Isotopica. In: REUNION REGIONAL SOBRE CLAUSURA DE INSTALACIONES QUE UTILIZAN MATERIAL RADIOACTIVO, 27-31 Octubre, 2008, Buenos Aires, Argentina. Proceedings... 2008.

    Palavras-Chave: brazil; decommissioning; nuclear facilities; laboratories; isotopes

  • IPEN-DOC 08052

    HORODYNSKI MATSUSHIGUE, L.B.; YOSHIMURA, E.M.; GUIMARAES FILHO, Z.O.; AMAKU, M.; CASTRO, R.M.; CYBULSKA, E.W.; MEDINA, N.H.; PASCHOLATI, P.R.. Assessing in the laboratory: can it be significant?. In: MOREIRA, M.A. (Ed.) CONFERENCIA INTERAMERICANA SOBRE EDUCACAO EM FISICA, 7, 3-7 jul, 2000, Canela, RS. Atas... Porto Alegre: Instituto de Fisica - UFRGS, 2000, 2000.

    Palavras-Chave: education; physics; educational facilities; laboratories; learning; evaluation

  • IPEN-DOC 01706

    VASCONCELLOS, M.B.A. . Atividades do laboratorio de analise por ativacao com neutrons da Divisao de Radioquimica do IPEN-CNEN/SP. In: 2o. CONGRESSO GERAL DE ENERGIA NUCLEAR, 24-29 de abril, 1988, Rio de Janeiro, RJ. 1988. p. 423-432.

    Palavras-Chave: laboratories; neutron activation analysis; radiochemistry; research programs; uses

  • IPEN-DOC 18921

    SANTOS, L.R.; XAVIER, M. ; KAKOI, A.A.Y.; SILVA JUNIOR, I.A.; CARDOSO, J.C.S. . Avaliação da atividade mínima de contadores de corpo inteiro e tireóide do laboratório de monitoramento in vivo do IPEN/CNEN-SP / Evaluation of the minimum detectable activity of whole-body and thyroid counters of the in vivo monitoring laboratory of IPEN/CNEN-SP. Scientia Plena, v. 8, n. 11, p. 119907-1 - 119907-4, 2012.

    Palavras-Chave: brazilian cnen; laboratories; monitors; monitoring; in vivo; whole-body counters; thyroid; occupational exposure

  • IPEN-DOC 21822

    SARMENTO, DANIELE M. . Avaliação dos níveis de radiação ambiental no laboratório de tomografia por emissão de pósitrons acoplada a tomografia computadorizada, microPET/CT / Evaluation of ambient radiation levels in positron emission tomography/computed tomography in microPET/CT laboratory . 2016. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 83 p. Orientador: Janete Cristina Gonçalves Gaburo Carneiro. DOI: 10.11606/D.85.2016.tde-01072016-132544

    Abstract: O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.

    Palavras-Chave: radiation protection; positron computed tomography; laboratories; ilo; safety standards; dose-response relationships; environmental exposure; acute irradiation; biological effects; personnel; employment

  • IPEN-DOC 20230

    ANTONIO, PATRICIA L. ; XAVIER, MARCOS ; CALDAS, LINDA V.E. . Bohm extrapolation chamber: Study of itas behavior in beta radiation fields at the Calibration Laboratory of IPEN. Radiation Physics and Chemistry, v. 104, p. 310-315, 2014.

    Palavras-Chave: brazilian cnen; laboratories; extrapolation chambers; dosimetry; calibration; strontium 90; yttrium 90; radiation detectors; aluminium; mylar; windows; comparative evaluations; radiations; beta sources

  • IPEN-DOC 19851

    ANTONIO, PATRICIA L.; XAVIER, MARCOS ; CALDAS, L.V.E. . Bohm extrapolation chamber: study of its behavior in beta radiation fields at the Calibration Laboratory of IPEN. In: INSTERNATIONAL CONFERENCE ON DOSIMETRY AND ITS APPLICATIONS, 1st, June 23-28, 2013, Praga, Republica Checa. Abstract... 2013. p. 146.

    Palavras-Chave: brazilian cnen; laboratories; extrapolation chambers; dosimetry; calibration; strontium 90; yttrium 90; radiation detectors; aluminium; mylar; windows; comparative evaluations; radiations; beta sources

  • IPEN-DOC 18698

    MONTEIRO, L.R. ; GRAFFITTI, D.; RODRIGUES, ALBANO M.; COTRIM, M.E.B. ; PIRES, M.A.P.. Brazilian ion chromatography proficiency test - a five year evaluation. In: INTERNATIONAL SYMPOSIUM ON BIOLOGICAL AND ENVIRONMENTAL REFERENCE MATERIALS, 13th, June 25-29, 2012, Vienna, Austria. Abstract... 2012.

    Palavras-Chave: ions; anions; water supply; chromatography; accuracy; testing; quality control; program management; brazilian cnen; laboratories; comparative evaluations

  • IPEN-DOC 10405

    KODAMA, Y. ; SORDI, G.M.A.; RODRIGUES, D.L. . A brief discussion on the decision aiding techniques applied to a laboratory of radioactive decontamination: a general case. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 11th, 23-28 May, 2004, Madrid, Spain. 2004.

    Palavras-Chave: brazilian cnen; laboratory equipment; decontamination; laboratories; radiation doses; radiation protection; research reactors

  • IPEN-DOC 11683

    MOREL, PIERRE; ARRUDA, TATIANA L. de; BOHRER-MOREL, MARIA B.C. . Calculation of uncertainties in influence quantities in biological assays. Brazilian Archives of Biology and Technology, v. 49, p. p. 97-99, 2006.

    Palavras-Chave: bioassay; uncertainty principle; calculation methods; quality control; laboratories; environmental quality

  • IPEN-DOC 11034

    MOREL, P.; ARRUDA, T.L.; MOREL, M.B.C.B. . Calculo de incertezas nas grandezas de influencia em ensaios biologicos. In: CONGRESSO LATINO AMERICANO DE METROLOGIA, 4., 9-12 nov, 2004, Foz do Iguacu, PR. Anais... 2004.

    Palavras-Chave: laboratories; brazilian cnen; bioassay; quality control; accuracy; errors

  • IPEN-DOC 19824

    PERINI, ANA P. ; NEVES, LUCIO P. ; MAIA, ANA F.; CALDAS, LINDA V.E. . Characterization and simulation of a new design parallel-plate ionization chamber for CT Dosimetry at Calibration Laboratories. IEEE Transactions on Nuclear Science, v. 60, n. 6, p. 4641-4649, 2013.

    Palavras-Chave: computerized tomography; dosimetry; dosimetry; simulation; monte carlo method; ionization chambers; laboratories; calibration

  • IPEN-DOC 27197

    POLO, IVON O. ; SANTOS, WILLIAM S. ; CALDAS, LINDA V.E. . Characterization of an extrapolation chamber in beta radiation beams and Monte Carlo modelling. Radiation Physics and Chemistry, v. 171, p. 1-9, 2020. DOI: 10.1016/j.radphyschem.2020.108746

    Abstract: At the Calibration Laboratory (LCI) of the IPEN/CNEN, studies are in development on the establishment of a standard composed by the beta radiation sources for the dosimetry and calibration for personal monitoring in Brazil. For this purpose is used the Böhm extrapolation chamber (PTW model 23392). This chamber was already characterized at LCI in 90Sr/90Y beams using two different entrance windows: one of aluminized Mylar and another of PET (polyethylene terephthalate) known as Hostaphan. In this work, this extrapolation chamber was characterized in 85Kr and 147Pm beams. All tests were carried out with the reference 90Sr /90Y source, for comparison purposes. The Monte Carlo code MCNP5 code was used to obtain an extrapolation chamber and the BSS2 system sources computational model, based on the determination of the absorbed dose rate. Saturation curves, ion collection efficiency, ion recombination, polarity effect, stability of response, null depth, linearity of response, variation of response as a function of source-detector distance, extrapolation curves, correction factors and absorbed dose rates were obtained. The difference between the experimental absorbed dose rates and those obtained using the Monte Carlo model, compared to those from the calibration certificates, was less than 1.9% for the 108 histories for each BSS2 system source. All results of the performed tests are within the limits of the international recommendations. The results for the 90Sr/90Y source were in good agreement with previous works performed at LCI. These results are suitable for the establishment of a standard instrument for the dosimetry and calibration of beta radiation sources and detectors in the LCI/IPEN. This standard will allow the calibration of detectors in beta radiation beams in dosimetry services in Brazil.

    Palavras-Chave: extrapolation chambers; radiation doses; beta sources; monte carlo method; calibration; calibration standards; laboratories

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.