Navegação IPEN por assunto "optical fibers"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 17225

    HUDSON, D.; MAGI, E.; GOMES, L. ; JACKSON, S.D.. 1W diode-pumped tunable Hosup(3+) Prsup(3+)-doped fluoride glass fibre laser. Electronics Letters, v. 47, n. 17, p. 985-986, 2011.

    Palavras-Chave: diode-pumped solid state lasers; holmium; praseodymium; doped materials; fluorides; glass; optical fibers

  • IPEN-DOC 28097

    MELO, PEDRO B. dos S.; SAMAD, RICARDO E. ; MOTTA, CLAUDIO C.. Analytical formulation of an Yb-doped tandem-pumping fiber amplifier. In: SBFOTON INTERNATIONAL OPTICS AND PHOTONICS CONFERENCE, May 31 - June 2, 2021, Online. Proceedings... Piscataway, NJ, USA: IEEE, 2021. DOI: 10.1109/SBFOTONIOPC50774.2021.9461980

    Abstract: An analytical formulation of a multi-kilowatt ytterbium-doped double-cladding tandem-pumped fiber amplifier was developed and is reported in this paper. The model consists of a system including the laser rate, pumping and seed power equations. The model was validated by describing a fiber amplifier behavior with a 5.986kW, 1018nm pumping and a signal seed of 75W, 1080nm, yielding a maximum power output of 5.448kW, with an efficiency of 91.1%. The thermal equations are solved for the temperature distribution along the fiber with a maximum temperature of 43.24°C, when the convective coefficient of 4000W. m-2. K -1 is used.

    Palavras-Chave: optical fibers; power range; ytterbium; lasers; optical pumping; equations

  • IPEN-DOC 11309

    CAVALCANTE, JONAS S. . Caracterizacao de copolimero reticulado, a base de acrilato e metacrilato obtido por fotopolimerizacao para aplicacao como guia de onda. 2005. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 73 p. Orientador: Jose Oscar Willian Vega Bustillos.

    Palavras-Chave: copolymers; cross-linking; pmma; polymerization; ultraviolet radiation; waveguides; optical fibers

  • IPEN-DOC 11791

    FREITAS, ANDERSON Z. de . Caracterização de tecidos biológicos através de tomografia por coerência óptica. 2007. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. p. Orientador: Nilson Dias Vieira Junior. DOI: 10.11606/T.85.2007.tde-19062008-155621

    Abstract: Neste trabalho implementamos dois sistemas de OCT, um deles utilizando fibras ópticas e um estágio de translação linear como sistema de deslocamento e foi desenvolvido no departamento de Física da Universidade Federal de Pernambuco. O outro sistema de OCT foi baseado um interferômetro de Michelson convencional, foi implementado no Centro de Lasers e Aplicações no Ipen utilizando a técnica de introdução de atraso com grade de difração e galvanômetro (fast Fourier Scanning), como sistema de varredura longitudinal. Foi implementado e um programa computacional para aquisição de dados automática, com geração das imagens de OCT em \"tempo real\". Com os sistemas desenvolvidos, foi possível detectar objetos imersos em meios espalhadores, detectar lesões de cáries induzidas in vitro quimicamente ou microbiologicamente, sendo este último um resultado original, além de avaliar a qualidade de restaurações dentárias. É importante destacar ainda que as alterações nas propriedades ópticas dos tecidos cariados podem ser detectadas pelo método de OCT muito antes de se tornarem aparentes aos métodos convencionais de detecção. Ela pode extrair informações quantitativas sobre a birrefringência do tecido, quando a técnica for sensível à polarização. Demonstramos que a análise de Fourier aplicada ao sinal de OCT permite detectar deslocamentos em sistemas periódicos e quase periódicos, abaixo do limite de resolução espacial definido pelo comprimento de coerência da fonte óptica. Com o auxílio desta metodologia aqui desenvolvida, mostramos que nosso sistema, com resolução de 10 ?m, é capaz de detectar variações em redes periódicas de algumas centenas de nanômetros entre as estruturas espalhadoras. Este desenvolvimento é uma contribuição inédita às aplicações de OCT.

    Palavras-Chave: tomography; optical properties; interferometry; optical fibers; teeth; optical systems; lasers; bone tissues; caries; enamels; animal tissues

  • IPEN-DOC 26720

    ZEZELL, DENISE M. ; SILVA JUNIOR, DANIEL S. da; MOTA, CLAUDIA C.B. de O.. Correção minimamente invasiva do sorriso. In: BRUGNERA JUNIOR, ALDO (Coord.); ZANIN, FATIMA (Coord.); NAMOUR, SAMIR (Coord.); SHIBLI, JAMIL A. (Coord.). Laser em odontologia: de clínico para clínico. São Paulo, SP: VW Cultural, 2019. p. 230-237, cap. 24.

    Palavras-Chave: dentistry; lasers; optical fibers; diode tubes

  • IPEN-DOC 17754

    SILVA, FERNANDO R. da; MORAES, JAIR R. de; BALDOCHI, SONIA L. . Crescimento de fibras de BaLiFsub(3) pela técnica de micro-pulling-down. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 29., 9-13 de maio, 2006, São Lourenço, MG. Resumos... 2006.

    Palavras-Chave: monocrystals; barium fluorides; lithium fluorides; optical fibers; crystal growth

  • IPEN-DOC 12789

    SILVA, FERNANDO R. da . Crescimento de fibras de LiYFsub(4) dopadas com Ndsup(3+) e Ersup(3+) para aplicações em lasers de estado sólido / Single fiber crystal growth of Nd3+ and Er3+- doped LiYF4 for solid state laser applications . 2008. Dissertação (Mestrado) - Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP, São Paulo. 74 p. Orientador: Sonia Licia Baldochi. DOI: 10.11606/D.85.2008.tde-18082009-164502

    Abstract: Neste trabalho foi estudado o crescimento de fibras monocristalinas de LiYF4 (YLF) dopadas com Er3+ ou Nd3+ pelo método de micro-pulling-down (-PD) no modo resistivo. Para otimização do processo de crescimento foi, desenvolvida nova metodologia de confecção de cadinhos, de forma a torná-los mais rígidos permitindo sua utilização em mais de uma experiência, aumentando a reprodutibilidade do processo. A câmara de crescimento também foi modificada para obtenção de vácuo da ordem de 10-7 torr. Devido ao tratamento térmico do sistema sob alto vácuo, antes da fusão do material, não foram observados transientes iniciais no processo de puxamento das fibras de YLF dopadas. Foram crescidas fibras de YLF:Nd com concentrações de 0,5, 1 e 1,5 mol% e fibras de YLF:Er com 1, 10, 20 mol %, com diâmetros da ordem de 0,7 mm e comprimentos de até 120mm. Devido a problemas mecânicos do sistema, o ancoramento das fibras, ou seja, o equilíbrio na interface sólidoliquido, mostrou-se muito difícil, sendo necessárias várias correções nos parâmetros de crescimento para estabilização da interface sólido-líquido resultando na formação de defeitos, principalmente na superfície, em regiões ao longo das fibras. Nas condições do presente estudo, o uso de uma atmosfera estática mostrou-se desfavorável. Testes de ganho efetuados com a fibra de YLF:Nd dopada com 1,5mol%, mostraram um ganho superior às perdas comprovando seu potencial para ação laser.

    Palavras-Chave: solid state lasers; optical fibers; crystal growth; erbium; neodymium; lithium fluorides

  • IPEN-DOC 19102

    SILVA, FERNANDO R. da . Crescimento de fibras de molibdato duplo de lítio e lantânio e adaptação de sistema de alto vácuo para micro pulling-down / Single crystal fibers growth of double lithium, lantanium molybdate and adjustment of a micro-pulling down furnace for high vacuum setup . 2013. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 96 p. Orientador: Sonia Licia Baldochi. DOI: 10.11606/T.85.2013.tde-22082013-141437

    Abstract: Neste trabalho, foi investigado o processo de crescimento de fibras monocristalinas (FMc) para aplicação em sistemas laser. Para o aperfeiçoamento na fabricação de FMc de fluoretos, foi projetada e construída uma nova câmara de crescimento para um forno comercial de micro-pulling down (μ-PD), permitindo um rígido controle da atmosfera de processamento, (sob vácuo, fluxo e atmosferas estáticas). Paralelamente, foi investigado o processo de crescimento de FMc de molibdatos duplos de terras raras, sendo crescidas e caracterizadas fibras puras e dopadas com Nd3+ do composto LiLa(MoO4)2 (LLM) com concentrações na faixa de 0,5 a 10mol%. A câmara de crescimento projetada para o controle de atmosfera foi avaliada em diversas condições de operação. Em particular, a mesma foi testada com o puxamento de fibras de LiF, sob atmosfera de CF4, para observação da sua eficiência no controle da atmosfera de crescimento. Foram obtidas FMc de LLM, homogêneas e transparentes; nas fibras puras foi observada a presença de facetas, entretanto, a adequação dos parâmetros de crescimento e a adição de dopantes permitiu a redução significativa destes defeitos. A difração de raios-x mostrou a cristalização no grupo espacial I41/a; medidas de tomografia por coerência ótica permitiram a detecção de centros de espalhamento em regiões onde ocorreram instabilidades no processo de crescimento. Foi possível observar que o coeficiente de segregação do íon Nd3+ é próximo à unidade nesta matriz. O ganho potencial para ação laser foi determinado utilizando-se uma solução numérica das equações de taxa do sistema em 805nm e regime CW. O ganho máximo da emissão laser em 1,064 μm foi previsto para a dopagem de 5% mol Nd3+.

    Palavras-Chave: solid state lasers; optical fibers; crystal growth; monocrystals; lithium; lanthanum; molybdates; doped materials; neodymium; x-ray diffraction; coherent radiation; tomography; optical models

  • IPEN-DOC 19659

    FONSECA, G.P.; RUBO, R.A.; MINAMISAWA, R.A.; SANTOS, G.R. dos; ANTUNES, P.C.G.; YORIYAZ, H. . Determination of transit dose profile for a sup(192)Ir HDR source. Medical Physics, v. 40, n. 5, p. 051717-1 - 051717-8, 2013.

    Palavras-Chave: brachytherapy; computerized simulation; distribution; dose rates; doses; dosimetry; films; iridium 192; irradiation; monte carlo method; optical fibers; radiation sources

  • IPEN-DOC 18935

    HUDSON, D.; ANDERSON, L.; MAGI, E.; EGGLETON, B.J.; GOMES, L. ; JACKSON, S.D.. Diode-pumped Hosup(3+), Prsup(3+)-doped fluoride glass double clad fibre laser tuneable from 2.825 um to 2.90 um. In: IEEE INTERNATIONAL PHOTONICS SOCIETY SUMMER TOPICAL MEETING SERIES, July 18-20, 2011, Montreal, Canada. Proceedings... 2011. DOI: 10.1109/PHOSST.2011.6000058

    Palavras-Chave: diode-pumped solid state lasers; holmium; praseodymium; doped materials; fluorides; glass; optical fibers

  • IPEN-DOC 18944

    HUDSON, D.; ANDERSON, L.; MAGI, E.; EGGLETON, B.J.; GOMES, L. ; JACKSON, S.D.. Diode-pumped tunable Hosup(3+), Prsup(3+)-doped fluoride glass double clad fibre laser. In: QUANTUM ELECTRONICS CONFERENCE & LASERS AND ELECTRO-OPTICS CONFERENCE, August 28 - September 1, 2011, Sidney, Australia. Proceedings... 2011. p. 525-526.

    Palavras-Chave: diode-pumped solid state lasers; holmium; praseodymium; doped materials; fluorides; glass; optical fibers

  • IPEN-DOC 25247

    PIERETTI, EURICO F. ; CORREA, OLANDIR V. ; PILLIS, MARINA F. ; NEVES, MAURICIO D.M. das . Electrochemical characterization of an optical fiber laser-treated biomaterial. In: PIGNATELLO, ROSARIO (Ed.); MUSUMECI, TERESA (Ed.). Biomaterials. London: IntechOpen, 2018. p. 75-85, cap. 5. DOI: 10.5772/intechopen.72653

    Abstract: The implant manufacturing process includes texturization to enhance its adhesion and marking the final products for their identification, long-term quality control and traceability. Marking is carried out after cleaning and prior to sterilization. These marks eventually can concentrate stress leading to premature failure. The marked areas are defective regions that affect the passive film formed on the metallic biomaterials used for implants favoring the onset of various corrosion types, such as pitting, crevice or fatigue. This study aims to evaluate the effect of a Yb optical fiber laser marking processes used for metallic implants on the localized corrosion resistance of the austenitic stainless steel ISO 5832-1. This is one of the most used materials for manufacturing implants. The electrochemical behavior of the marked areas obtained by this method was evaluated in a phosphate- buffered saline (PBS) solution with pH of 7.4 and the results were compared with unmarked samples. All tested surfaces were prepared according to the recommendations for the use in surgery. For localized corrosion resistance evaluation, electrochemical tests such as monitoring the open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and cyclic potentiodynamic polarization measurements were performed. The results showed that the laser marks affect the protector characteristics of the biomaterial’s passive film. Lower pitting resistance was associated to the laser marked areas.

    Palavras-Chave: biological repair; stainless steels; electrochemistry; lasers; optical fibers

  • IPEN-DOC 21268

    GOMES, LAERCIO ; RHONEHOUSE, DANIEL; NGUYEN, DAN T.; ZONG, JIE; CHAVEZ-PIRSON, ARTURO; JACKSON, STUART D.. Energy transfer and energy level decay processes of Ersup(3+) in water-free tellurite glass. Optical Materials, v. 50, p. 268-274, 2015.

    Palavras-Chave: infrared spectra; fibers; lasers; optical fibers; spectroscopy; energy transfer; glass; tellurium oxides; erbium oxides; decay; fluorescence spectroscopy

  • IPEN-DOC 08861

    CAVALCANTE, J.S.; MIRAGLIA, J.; LUGAO, A.B. ; TONOLLI, J.. Estudo do processo de co-polimerizacao de acrilatos e metacrilatos induzido por irradiacao gama. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: pmma; acrylates; copolymerization; gamma radiation; cobalt 60; thermal analysis; flexibility; optical properties; optical fibers; polymers

  • IPEN-DOC 17245

    RODRIGUEZ, H.M.H.; GARCEZ, A.S.; DAGHASTANLI, N.A.; NUNEZ, S.C.; FREGNANI, E.R.; AZAMBUJA JUNIOR, N.; SABINO, C.P.; RIBEIRO, M.S.. É realmente necessário o uso de fibra óptica na PDT endodôntica?. Photodiagnosis and Photodynamic Therapy, v. 25, n. Supl. 1, p. 293, 2011.

    Palavras-Chave: optical fibers; antimicrobial agents; dentistry; therapy; photosensitivity

  • IPEN-DOC 11713

    KASSAB, L.R.P.; HORA, W.G.; MARTINELLI, J.R. ; SENE, F.F. ; JAKUTIS, J.; WETTER, N.U. . Fabrication and characterization of Ersup(3+) doped GeOsub(2)-PbO and GeOsub(2)-PbO-Bisub(2)Osub(3) glass fibers. Journal of Non-Crystalline Solids, v. 352, p. p. 3530-3534, 2006.

    Palavras-Chave: optical fibers; oxides; glass; rare earths; germanates

  • IPEN-DOC 14149

    PORTELA, MAYERLIN N.; TOPOMONDZO, JOSEPH D.; NOGUEIRA, GIOVANA T.; CRUZ, FLAVIO C.; WETTER, NIKLAUS U. . Frequency doubled Nd:YLF laser: an all-solid-state local oscillator for a calcium optical atomic clock. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 32., 11-15 de maio, 2009, Aguas de Lindoia, SP. Resumo... 2009.

    Palavras-Chave: diode-pumped solid state lasers; neodymium lasers; optical fibers; atoms; calcium; noise; microwave radiation; frequency measurement

  • IPEN-DOC 11174

    ESPIRITO SANTO, A.M.; RANIERI, I.M. ; BRITO, G.E.S.; EPELBAUM, B.M.; MORATO, S.P. ; VIEIRA JUNIOR, N.D. ; BALDOCHI, S.L. . Growth of LiYFsub(4) single-crystalline fibres by micro-pulling-down technique. Journal of Crystal Growth, v. 275, n. 3-4, p. 528-533, 2005.

    Palavras-Chave: yttrium fluorides; lithium fluorides; crystal growth; monocrystals; optical fibers

  • IPEN-DOC 27576

    GUIMARAES, LUCCA B.; BOTAS, ALEXANDRE M.P.; FELINTO, MARIA C.F.C. ; FERREIRA, RUTE A.S.; CARLOS, LUIS D.; MALTA, OSCAR L.; BRITO, HERMI F.. Highly sensitive and precise optical temperature sensors based on new luminescent Tb3+/Eu3+ tetrakis complexes with imidazolic counterions. Materials Advances, v. 1, n. 6, p. 1988-1995, 2020. DOI: 10.1039/d0ma00201a

    Abstract: In the present work, new Tb3+/Eu3+ tetrakis(benzoyltrifluoroacetone) complexes containing imidazolic counterions were successfully prepared and characterized via elemental analysis, infrared spectroscopy, thermogravimetry, and X-ray powder diffraction. Photophysical features of the Eu3+ ion, such as the intrinsic emission quantum yields, radiative and non-radiative decay rates, and emission lifetimes were dramatically improved when compared with the data from the hydrated tris complex reported in the literature. The values found for the absolute emission quantum yields are up to 0.79 and ratiometric luminescent thermometers were built-up based on the ratio between the spectral areas of the 5D0 → 7F2 (Eu3+) and 5D4 → 7F5 (Tb3+) transitions. The best contactless temperature sensor operates in a wide temperature range (20–225 K) with a relative thermal sensitivity higher than 4% K−1 (maximum value of ∼7.6% K−1 at 20 K) and a temperature uncertainty lower than 0.1 K with a minimal lower than 0.01 K by combining excitation at the ligand (360 nm) and the Tb3+ ion (489 nm), illustrating the potential of lanthanide-based tetrakis complexes in the design of efficient luminescent thermometers.

    Palavras-Chave: photoluminescence; sensors; optical fibers; temperature measurement; rare earths; emission spectra

  • IPEN-DOC 18942

    MILANESE, D.; LOUSTEAU, J.; GOMES, L. ; BOETTI, N.; ABRATE, S.; JACKSON, S.. Ho-doped tellurite glasses for emission in the mid infrared wavelength region. In: EUROPEAN CONFERENCE ON LASERS AND ELECTRO-OPTICS; EUROPEAN QUANTUM ELECTRONICS CONFERENCE, 12th, May 22, 2011, Munique, Alemanha. Abstract... 2011.

    Palavras-Chave: holmium ions; doped materials; tellurides; glass; optical fibers; infrared spectra; wavelengths

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.