  • IPEN-DOC 16962

    FERNANDES, MARCO A.R.; RIBEIRO, VICTOR A.B.; VIANA, RODRIGO S.S.; COELHO, TALITA S.. Analysis of the variation of the attenuation curve in function of the radiation field size 50 KvP x-ray beams using the MCNP-5C code. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: accelerators; depth dose distributions; monte carlo method; neoplasms; stochastic processes; tumor cells; x radiation; x-ray equipment; radiotherapy

  • IPEN-DOC 07086

    GALHARDO, E.P.; CALDAS, L.V.E. . Aplicacao de um sistema Tandem de camaras de ionizacao para a determinacao da filtracao inerente. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: x-ray equipment; x-ray tubes; x radiation; half-thickness; ionization chambers

  • IPEN-DOC 20952

    HONDA, CRISTIANE J. de C. . Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography . 2015. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, São Paulo. 130 p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2015.tde-16092015-095035

    Abstract: A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais.

    Palavras-Chave: biomedical radiography; mammary glands; x-ray equipment; ionization chambers; dosimetry; diagnostic uses; quality control

  • IPEN-DOC 13389

    YOSHIZUMI, MAIRA T.; CALDAS, LINDA V.E. . Application of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, October 19-24, 2008, Buenos Aires, Argentina. Proceedings... 2008.

    Palavras-Chave: radiotherapy; ionization chambers; x-ray equipment; x-ray sources; quality control

  • IPEN-DOC 28319

    BATISTA, WILSON O.; SOARES, MARIA R. ; RIOS, JACQUELINE M.G.; SOUZA, ANTONIO C dos S.; PINHEIRO, ISABELLE M.; RAMIREZ, JOSE L.J.V.; CALDAS, LINDA V. E. . Assessment of scattered radiation from hand-held dental x-ray equipment using the Monte Carlo method. Journal of Radiological Protection, v. 41, n. 4, p. 654-668, 2021. DOI: 10.1088/1361-6498/abf3cd

    Abstract: The objective of the present study was to evaluate the intensity and spatial distribution of the scattered radiation caused by the use of hand-held x-ray equipment in the zone occupied by the operator, using the Monte Carlo simulation for radiographic views of the upper and lower incisor teeth, and the consequent evaluation of the equivalent dose in the lens. In order to carry out this evaluation, the geometry of a typical dental facility with plaster walls containing the scattering object was used for the computational scenario implemented for the Monte Carlo method simulation. The PENELOPE code for Monte Carlo simulation of electron and photon transport was used with the radiation beam represented by a 60 kV spectrum, 1.5 mm Al and tungsten target. The simulations were carried out with typical parameters for workload and the number of radiographs/week. The results showed that the exposure levels varied significantly according to the angle of the x-ray beam and with the distance to the scattering object. It is concluded that the incorporation of hand-held equipment in dental radiology must be accompanied by the surveillance of occupational exposure levels and a review of the training structure of professionals in dental radiology regarding aspects of radiological protection and the particularities of using this type of equipment.

    Palavras-Chave: dentistry; x-ray equipment; monte carlo method; oral cavity; biomedical radiography; scattering

  • IPEN-DOC 10701

    MIRANDA, J.A.; POTIENS, M.P.A. . Avaliacao dos valores de taxa de kerma no ar dos sistemas de radiacao X utilizados na calibracao de intrumentos de medida em radiodiagnostico. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: air; calibration standards; calibration; ionization chambers; kerma; quality assurance; radiation doses; radiation protection; radiation quality; x-ray equipment

  • IPEN-DOC 11519

    SOARES, FERNANDA C.S. . Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica. 2006. Dissertacao (Mestrado) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. p. Orientador: Linda Viola Ehlin Caldas. DOI: 10.11606/D.85.2006.tde-16052012-103302

    Abstract: Neste trabalho foram avaliados aventais de proteção e blindagens de ovário de cinco fabricantes segundo as normas NBR / IEC 61331-1 e NBR / IEC 61331-3 de 2004. Para a determinação da espessura equivalente de atenuação foram aplicadas três metodologias diferentes (interpolação linear, modelo de Archer e somatório de exponenciais), uma vez que a norma não indica como este valor deve ser obtido. Além disso, foram estimadas as incertezas associadas a cada método e a influência do número de medições na incerteza combinada. As características de confecção avaliadas foram: documento acompanhante, projeto, materiais, dimensões e marcação da etiqueta. Para esta avaliação foi elaborado um formulário que contemplava todas as exigências da NBR / IEC 61331-3. Os resultados mostraram uma grande diferença entre os valores de espessura equivalente de atenuação declarados e medidos. A comparação dos resultados das três metodologias aplicadas mostrou que há pouca variação entre os valores obtidos e entre as incertezas associadas nas diferentes metodologias. Foi possível observar também que o número de medições não contribui significativamente para o aumento da incerteza nas três metodologias. A metodologia que melhor se adequou à rotina do laboratório foi a metodologia da interpolação linear com cinco medições da taxa de kerma no ar. A discrepância entre os resultados apresentados neste trabalho e as exigências das normas estudadas mostra a necessidade de tornar compulsória a certificação dos dispositivos de proteção, contribuindo assim para o aumento da proteção radiológica do usuário.

    Palavras-Chave: attenuation; data covariances; experimental data; ionization chambers; kerma; protective clothing; radiation protection; radiation quality; safety standards; thickness; x-ray equipment

  • IPEN-DOC 09360

    MAIA, A.F.; CALDAS, L.V.E. . Calibracao de uma camara tipo lapis em feixes padroes de raios-X. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1Parte 1, p. 902-906, 2002.

    Palavras-Chave: ionization chambers; calibration; computerized tomography; x-ray equipment; energy dependence; x radiation

  • IPEN-DOC 08728

    MAIA, A.F.; CALDAS, L.V.E. . Calibracao de uma camara tipo lapis em feixes padroes de raios-X. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: ionization chambers; calibration; computerized tomography; x-ray equipment; energy dependence; x radiation

  • IPEN-DOC 08651

    POTIENS, M.P.A. ; CALDAS, L.V.E. . Calibration of kVsub(p) meters used in quality control tests in diagnostic radiology by spectrometry. Radiation Protection Dosimetry, v. 98, n. 3, p. 343-346, 2002. DOI: 10.1093/oxfordjournals.rpd.a006726

    Palavras-Chave: x-ray equipment; quality control; calibration; spectroscopy; high-purity ge detectors; radiology; diagnostic techniques

  • IPEN-DOC 07083

    DIAS, V.; XAVIER, M. ; CALDAS, L.V.E. . Caracterizacao de campos padroes de radiacao X de energias intermediarias, nivel terapia. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: x radiation; x-ray equipment; ionization chambers; half-thickness; energy dependence; radiotherapy; calibration; dosimetry

  • IPEN-DOC 08029

    GUERRA, A.B.; CALDAS, L.V.E. . Caracterizacao de campos padroes para calibracao de instrumentos, nivel mamografia. In: FROTA, M.N. (Ed.); CARMO, L.C.S. (Ed.) INTERNATIONAL CONFERENCE ON ADVANCED METROLOGY IN CHEMISTRY AND LABORATORY QUALITY; BRAZILIAN CONGRESS OF METROLOGY, 2nd; INTER-AMERICAN CONGRESS ON METROLOGY IN CHEMISTRY, 2nd; NATIONAL MEETING OF ACCREDITED LABORATORIES, 2nd, Dec. 4-7, 2000, Sao Paulo, SP. Proceedings... 2000. p. 311-319.

    Palavras-Chave: ionization chambers; calibration; mammary glands; biomedical radiography; x radiation; molybdenum; x-ray equipment; quality control

  • IPEN-DOC 17525

    SILVA, ERIC A.B. da; CALDAS, LINDA V.E. . Caracterização de uma câmara de extrapolação em feixes padrões de raios X, nível radioagnóstico. In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DOS PAÍSES DE LÍNGUA PORTUGUESA, 2.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 2.; CONGRESSO INTERNACIONAL DE PROTEÇÃO INDUSTRIAL, 5., 17-20 de maio, 2011, Recife, PE. Anais... 2011.

    Palavras-Chave: biomedical radiography; extrapolation chambers; x radiation; x-ray detection; x-ray dosimetry; x-ray equipment; x-ray radiography; x-ray sources

  • IPEN-DOC 13365

    AFONSO, L.C.; VIVOLO, V. ; CALDAS, L.V.E. . Characteristics of a tandem system of ionization chambers in X-ray beams mammography level. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 7th, June 22-27, 2008, Praga, Republica Tcheca. Proceedings... 2008.

    Palavras-Chave: biomedical radiography; dosemeters; dosimetry; ionization chambers; kerma; mammary glands; quality control; x radiation; x-ray equipment

  • IPEN-DOC 13388

    YOSHIZUMI, MAIRA T.; CALDAS, LINDA V.E. . Characterization and quality control tests of a transmission ionization chamber using an x-ray equipment. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 12th, October 19-24, 2008, Buenos Aires, Argentina. Proceedings... 2008.

    Palavras-Chave: x-ray equipment; ionization chambers; energy dependence; quality control

  • IPEN-DOC 21016

    HONDA, CRISTIANE J.C.; SILVA, JONAS O.; CALDAS, LINDA V.E. . Characterization tests and application of special ionization chambers in standard mammography beams. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: uses; ionization chambers; mammary glands; biomedical radiography; x radiation; beams; x-ray equipment

  • IPEN-DOC 24817

    ICHIKAWA, RODRIGO U. ; ROCA, ALEJANDRO G.; LOPEZ-ORTEGA, ALBERTO; ESTRADER, MARTA; PERAL, INMA; TURRILLAS, XABIER; NOGUES, JOSEP. Combining X-Ray whole powder pattern modeling, rietveld and pair distribution function analyses as a novel bulk approach to study interfaces in heteronanostructures: oxidation front in FeO/Fe3O4 core/shell nanoparticles as a case study. Small, v. 14, n. 30, p. 1800804-1 - 1800804-11, 2018. DOI: 10.1002/smll.201800804

    Abstract: Understanding the microstructure in heterostructured nanoparticles is crucial to harnessing their properties. Although microscopy is ideal for this purpose, it allows for the analysis of only a few nanoparticles. Thus, there is a need for structural methods that take the whole sample into account. Here, a novel bulk‐approach based on the combined analysis of synchrotron X‐ray powder diffraction with whole powder pattern modeling, Rietveld and pair distribution function is presented. The microstructural temporal evolution of FeO/Fe3O4 core/shell nanocubes is studied at different time intervals. The results indicate that a two‐phase approach (FeO and Fe3O4) is not sufficient to successfully fit the data and two additional interface phases (FeO and Fe3O4) are needed to obtain satisfactory fits, i.e., an onion‐type structure. The analysis shows that the Fe3O4 phases grow to some extent (≈1 nm) at the expense of the FeO core. Moreover, the FeO core progressively changes its stoichiometry to accommodate more oxygen. The temporal evolution of the parameters indicates that the structure of the FeO/Fe3O4 nanocubes is rather stable, although the exact interface structure slightly evolves with time. This approach paves the way for average studies of interfaces in different kinds of heterostructured nanoparticles, particularly in cases where spectroscopic methods have some limitations.

    Palavras-Chave: iron oxides; nanoparticles; shells; oxidation; hybridization; x-ray equipment

  • IPEN-DOC 07049

    ROS, R.A.; CALDAS, L.V.E. . Controle de qualidade de medidores de tensao nao-invasivos em equipamento de raios X, nivel diagnostico. Radiologia Brasileira, v. 34, n. 2, p. 89-94, 2001. DOI: 10.1590/S0100-39842001000200007

    Palavras-Chave: x-ray equipment; x radiation; quality control; electric potential; electric measuring instruments; monitors; high-purity ge detectors; ionization chambers; diagnosis; radiology

  • IPEN-DOC 08939

    ROS, R.A.; CALDAS, L.V.E. . Controle de qualidade de monitores nao invasivos. In: JORNADA PAULISTA DE RADIOLOGIA, abr, 2000, Sao Paulo, SP. Resumos... 2000. p. 1764.

    Palavras-Chave: survey monitors; quality control; x-ray equipment

  • IPEN-DOC 07091

    COSTA, A.M.; CALDAS, L.V.E. . Curvas de saturacao de camaras de ionizacao de placas paralelas. In: REGIONAL CONGRESS ON RADIATION PROTECTION AND SAFETY, 5th, REGIONAL IRPA CONGRESS, Apr. 29 - May 4, 2001, Recife, PE. Proceedings... Recife: SBPR, 2001, 2001.

    Palavras-Chave: ionization chambers; x radiation; quality control; x-ray equipment; dosimetry; radiotherapy; diagnosis; radiology

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.