JavaScript is disabled for your browser. Some features of this site may not work without it.
Navegação IPEN por assunto "x-ray sources"
-
FREITAS, LUCAS F. de
; VARCA, GUSTAVO H.C.
; BATISTA, JORGE G. dos S.
; LUGAO, ADEMAR B.
.
An overview of the synthesis of gold nanoparticles using radiation technologies.
Nanomaterials,
v. 8,
n. 11,
2018.
DOI:
10.3390/nano8110939
Abstract:
At a nano-level, optical properties of gold are unique and gave birth to an emerging
platform of nanogold-based systems for diverse applications, because gold nanoparticle properties
are tunable as a function of size and shape. Within the available techniques for the synthesis of gold
nanoparticles, the radiolytic synthesis allows proper control of the nucleation process without the need
for reducing agents, in a single step, combined or not with simultaneous sterilization. This review
details and summarizes the use of radiation technologies for the synthesis and preparation of gold
nanoparticles concerning fundamental aspects, mechanism, current pathways for synthesis and
radiation sources, as well as briefly outlines final applications and some toxicity aspects related to
nanogold-based systems.
Palavras-Chave:
gold;
nanoparticles;
gamma radiation;
electron beams;
x-ray sources;
radiolysis;
nanotechnology;
medicine;
diagnostic uses;
ionizing radiations
FREITAS, LUCAS F. de; VARCA, GUSTAVO H.C.; BATISTA, JORGE G. dos S.; LUGAO, ADEMAR B.
An overview of the synthesis of gold nanoparticles using radiation technologies.
Nanomaterials,
v. 8,
n. 11,
2018.
DOI:
10.3390/nano8110939.
Disponível em: http://repositorio.ipen.br/handle/123456789/29423. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
YOSHIZUMI, MAIRA T.; CALDAS, LINDA V.E.
.
Application of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level.
In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION,
October 19-24, 2008,
Buenos Aires, Argentina.
Proceedings...
2008.
Palavras-Chave:
radiotherapy;
ionization chambers;
x-ray equipment;
x-ray sources;
quality control
YOSHIZUMI, MAIRA T.; CALDAS, LINDA V.E.
Application of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level.
In:
INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION,
October 19-24, 2008,
Buenos Aires, Argentina.
Proceedings...
2008.
Disponível em: http://repositorio.ipen.br/handle/123456789/15938. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, NATALIA F.
; XAVIER, MARCOS
; VIVOLO, VITOR
; CALDAS, LINDA V.E.
.
Caracterização de uma camara de ionização de ar livre para baixas energias / Characterization of a free air ionization chamber for low energies.
In: CONGRESSO BRASILEIRO DE METROLOGIA, 8.,
29 de novembro - 4 de dezembro, 2015,
Bento Gonçalves, RS.
Anais...
2015.
Palavras-Chave:
ionization chambers;
kerma;
x-ray sources;
beams
SILVA, NATALIA F.; XAVIER, MARCOS; VIVOLO, VITOR; CALDAS, LINDA V.E.
Caracterização de uma camara de ionização de ar livre para baixas energias.
In:
CONGRESSO BRASILEIRO DE METROLOGIA, 8.,
29 de novembro - 4 de dezembro, 2015,
Bento Gonçalves, RS.
Anais...
2015.
Disponível em: http://repositorio.ipen.br/handle/123456789/25494. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, ERIC A.B. da; CALDAS, LINDA V.E.
.
Caracterização de uma câmara de extrapolação em feixes padrões de raios X, nível radioagnóstico.
In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DOS PAÍSES DE LÍNGUA PORTUGUESA, 2.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 2.; CONGRESSO INTERNACIONAL DE PROTEÇÃO INDUSTRIAL, 5.,
17-20 de maio, 2011,
Recife, PE.
Anais...
2011.
Palavras-Chave:
biomedical radiography;
extrapolation chambers;
x radiation;
x-ray detection;
x-ray dosimetry;
x-ray equipment;
x-ray radiography;
x-ray sources
SILVA, ERIC A.B. da; CALDAS, LINDA V.E.
Caracterização de uma câmara de extrapolação em feixes padrões de raios X, nível radioagnóstico.
In:
CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DOS PAÍSES DE LÍNGUA PORTUGUESA, 2.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 2.; CONGRESSO INTERNACIONAL DE PROTEÇÃO INDUSTRIAL, 5.,
17-20 de maio, 2011,
Recife, PE.
Anais...
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/12348. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
LIMA, MATEUS H. de
.
Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia
/ Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography
.
2014.
Dissertação (Mestrado em Tecnologia Nuclear) -
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP,
São Paulo.
78 p.
Orientador: Linda Viola Ehlin Caldas.
DOI:
10.11606/D.85.2014.tde-02052014-152732
Abstract:
Neste trabalho foram realizados testes de estabilidade e de caracterização de uma câmara de ionização de ar-livre com cilindros concêntricos da marca Victoreen, modelo 481. Os testes foram feitos utilizando feixes diretos de mamografia como uma contribuição para a implantação desta câmara como sistema padrão primário para a grandeza kerma no ar. Os testes de caracterização realizados foram: curva de saturação, eficiência de coleção de íons, efeito de polaridade, linearidade da resposta com a taxa de kerma no ar e linearidade da resposta com a variação volumétrica. O teste de eficiência de coleção de íons possibilitou a determinação do fator de correção para recombinação iônica. A maioria dos testes realizados esteve em conformidade com os limites estabelecidos por normas internacionais. Foram obtidos os fatores de correção para atenuação de fótons no ar para as qualidades de mamografia com filtros de alumínio e molibdênio. Foram determinados também os fatores de correção para transmissão e espalhamento de fótons nas bordas do diafragma para as qualidades de mamografia com filtro de alumínio e para a qualidade padrão de mamografia com filtro de molibdênio.
Palavras-Chave:
mammary glands;
biomedical radiography;
x-ray sources;
ionization chambers;
kerma
LIMA, MATEUS H. de.
Caracterização de uma câmara de ionização ar-livre em feixes diretos de raios X utilizados em mamografia.
Orientador: Linda Viola Ehlin Caldas.
2014.
78 f.
Dissertação (Mestrado em Tecnologia Nuclear) -
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP,
São Paulo.
DOI:
10.11606/D.85.2014.tde-02052014-152732.
Disponível em: http://repositorio.ipen.br/handle/123456789/23297. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CORREA, EDUARDO de L.; VIVOLO, VITOR
; POTIENS, MARIA da P.A.
.
Comparison of KVp and PPV measurements between a constant potential and clinical x-ray system used for calibration in mammography.
In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd,
October 24-28, 2011,
Belo Horizonte, MG.
Proceedings...
Sao Paulo: ABEN, 2011,
2011.
Palavras-Chave:
calibration;
calibration standards;
hvdc systems;
mammary glands;
x radiation;
x-ray sources;
biomedical radiography
CORREA, EDUARDO de L.; VIVOLO, VITOR; POTIENS, MARIA da P.A.
Comparison of KVp and PPV measurements between a constant potential and clinical x-ray system used for calibration in mammography.
In:
INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd,
October 24-28, 2011,
Belo Horizonte, MG.
Proceedings...
Sao Paulo: ABEN, 2011,
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/16186. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NOGUEIRA, M.S.; CAMPOS, L.L.
; MOTA, H.C..
Determination of conversion coefficients between air kerma or photon fluence and ambient dose equivalent for diagnostic X ray beams.
Radiation Protection Dosimetry,
v. 81,
n. 2,
p. 123-132,
1999.
Palavras-Chave:
kerma;
photons;
dose equivalents;
diagnostic uses;
x-ray sources;
radiation quality;
pmma;
phantoms;
ionization chambers;
thermoluminescent dosemeters;
shielding;
radiation protection
NOGUEIRA, M.S.; CAMPOS, L.L.; MOTA, H.C.
Determination of conversion coefficients between air kerma or photon fluence and ambient dose equivalent for diagnostic X ray beams.
Radiation Protection Dosimetry,
v. 81,
n. 2,
p. 123-132,
1999.
Disponível em: http://repositorio.ipen.br/handle/123456789/7156. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CORREA, EDUARDO de L.
; VIVOLO, VITOR
; POTIENS, MARIA da P.A.
.
Determination of the effective energy in X-rays standard beams, mammography level.
Radioproteção,
v. 2,
n. 20,
p. 59-63,
2012.
Palavras-Chave:
biomedical radiography;
critical organs;
dose commitments;
integral doses;
internal irradiation;
irradiation procedures;
isodose curves;
local irradiation;
mammary glands;
spatial dose distributions;
x radiation;
x-ray radiography;
x-ray sources
CORREA, EDUARDO de L.; VIVOLO, VITOR; POTIENS, MARIA da P.A.
Determination of the effective energy in X-rays standard beams, mammography level.
Radioproteção,
v. 2,
n. 20,
p. 59-63,
2012.
Disponível em: http://repositorio.ipen.br/handle/123456789/9053. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CORREA, EDUARDO de L.; VIVOLO, VITOR
; POTIENS, MARIA da P.A.
.
Determination of the effective energy in X-rays standard beams, mammography level.
In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DOS PAÍSES DE LÍNGUA PORTUGUESA, 2.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 2.; CONGRESSO INTERNACIONAL DE PROTEÇÃO INDUSTRIAL, 5.,
17-20 de maio, 2011,
Recife, PE.
Anais...
2011.
Palavras-Chave:
biomedical radiography;
critical organs;
dose commitments;
integral doses;
internal irradiation;
irradiation procedures;
isodose curves;
local irradiation;
mammary glands;
spatial dose distributions;
x radiation;
x-ray radiography;
x-ray sources
CORREA, EDUARDO de L.; VIVOLO, VITOR; POTIENS, MARIA da P.A.
Determination of the effective energy in X-rays standard beams, mammography level.
In:
CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DOS PAÍSES DE LÍNGUA PORTUGUESA, 2.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 2.; CONGRESSO INTERNACIONAL DE PROTEÇÃO INDUSTRIAL, 5.,
17-20 de maio, 2011,
Recife, PE.
Anais...
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/12354. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FRIMAIO, AUDREW; COSTA, PAULO R.; VANDERLINDE, FLAVIA V.F.; CAMPOS, LETICIA L.
.
Development of a ceramic compound for coating the walls of image diagnosis centers for dose reduction of the medical team.
International Journal of Low Radiation,
v. 3,
n. 4,
p. 355-362,
2006.
Palavras-Chave:
ceramics;
coatings;
shielding;
images;
diagnosis;
radiations;
attenuation;
x-ray sources
FRIMAIO, AUDREW; COSTA, PAULO R.; VANDERLINDE, FLAVIA V.F.; CAMPOS, LETICIA L.
Development of a ceramic compound for coating the walls of image diagnosis centers for dose reduction of the medical team.
International Journal of Low Radiation,
v. 3,
n. 4,
p. 355-362,
2006.
Disponível em: http://repositorio.ipen.br/handle/123456789/5344. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VILLANI, D.
; RODRIGUES JUNIOR, O.
; CAMPOS, L.L.
.
Dosimetric characterization of 3D printed phantoms at different infill percentages for diagnostic X-ray energy range.
Radiation Physics and Chemistry,
v. 172,
p. 1-6,
2020.
DOI:
10.1016/j.radphyschem.2020.108728
Abstract:
The aim of this paper is to characterize 3D printed phantoms and printing set-ups with different infill percentages
for imaging energy X-ray beams attenuation. 3D printing performance was studied using the fused filament
fabrication (FFF) technique with PLA (Polylactic Acid) and ABS (Acrylonitrile Butadiene Styrene) filaments.
Phantom plates were printed and, using the Pantak Seifert X-ray system with different beam qualities in the
diagnostic range, the attenuation coefficients were obtained experimentally with the transmission method and
results compared with PMMA used as reference and theoretical data. Different percentages of infill of printed
phantoms were also evaluated and transmission characterized. The attenuation coefficients were determined for
the different beam qualities and results show that the variation in the values of attenuation coefficients decreases
as the infill quality increases. Attenuation characteristics evaluated indicates the suitable equivalence of PLA to
PMMA for 3D printing water/tissue equivalent most complex geometry phantoms. The different printing modes
characterized together with their attenuation coefficients for the X-ray beams will be studied and used in the
development of new 3D printed phantoms in our institute.
Palavras-Chave:
phantoms;
computer codes;
x-ray sources;
lactic acid;
dosimetry;
acrylonitrile;
butadiene;
styrene;
radiations;
beams
VILLANI, D.; RODRIGUES JUNIOR, O.; CAMPOS, L.L.
Dosimetric characterization of 3D printed phantoms at different infill percentages for diagnostic X-ray energy range.
Radiation Physics and Chemistry,
v. 172,
p. 1-6,
2020.
DOI:
10.1016/j.radphyschem.2020.108728.
Disponível em: http://repositorio.ipen.br/handle/123456789/31432. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GONSALVES, T.C.
; SILVA, F.M.; VIEIRA, L.S.; CASINI, J.C.S.; FARIA, R.N.
.
Electrochemical characteristics and microstructure of activated carbon powder supercapacitors for energy storage.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 22.,
06-10 de novembro, 2016,
Natal, RN.
Proceedings...
2016.
p. 3832-3841.
Abstract:
In recent years, extensive investigations have concentrated on the study and improvement of supercapacitors electrode materials. The electric devices produced with these materials are used for stored energy over time periods ranging from seconds to several days. The main factor determining the energy storage time of a supercapacitor is its self-discharge rate. This property concerns to the gradual decrease in the electric potential that occurs when the supercapacitor terminals are left unconnected to either a charging circuit or an electric load. Self-discharge is attenuated with a decrease in room temperature and lifetime is enhanced. This paper addresses this aspect and reports the results of a work carried out on a systematic study with supercapacitors with nominal capacitance of 1.0 rated at a DC potential of 5.5 V and 10.0 F at 2,7 V. The specific capacitance, internal resistance and self-discharge of commercial activated carbon electrode supercapacitors have been investigated. Specific capacitances were measured in this study using cyclic voltammetry (CV). Specific capacitances of 44.4 and 66.7 Fg-1 were determined for distinct carbon electrodes supercapacitors. Self-discharge were carried out at room temperature and close to the freezing point. Internal resistances of the supercapacitors were calculated using the discharge curve at room temperature. The microstructures of the electrode material have been investigated using scanning electron microscopy (SEM).
Palavras-Chave:
activated carbon;
capacitance;
capacitors;
electric discharges;
electrodes;
energy storage;
microstructure;
powders;
scanning electron microscopy;
voltametry;
x-ray sources
GONSALVES, T.C.; SILVA, F.M.; VIEIRA, L.S.; CASINI, J.C.S.; FARIA, R.N.
Electrochemical characteristics and microstructure of activated carbon powder supercapacitors for energy storage.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 22.,
06-10 de novembro, 2016,
Natal, RN.
Proceedings...
2016.
p. 3832-3841.
Disponível em: http://repositorio.ipen.br/handle/123456789/27243. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GONSALVES, TAYARA C.
; SILVA, FRANKS M.; VIEIRA, LIGIA S.; CASINI, JULIO C.S.; FARIA, RUBENS N. de
.
Electrochemical characteristics and microstructures of activated carbon powder supercapacitors for energy storage.
Materials Science Forum,
v. 930,
p. 597-602,
2018.
DOI:
10.4028/www.scientific.net/MSF.930.597
Abstract:
In recent years, extensive investigations have focused on the study and improvement of
supercapacitor electrode materials. The electric devices produced with these materials are used to
store energy over time periods ranging from seconds to several days. The main factor that
determines the energy storage period of a supercapacitor is its self-discharge rate, i.e., the gradual
decrease in electric potential that occurs when the supercapacitor terminals are not connected to
either a charging circuit or electric load. Self-discharge is attenuated at lower temperatures,
resulting in an increased energy storage period. This paper addresses the temperature-dependence of
self-discharge via a systematic study of supercapacitors with nominal capacitances of 1.0 and 10.0 F
at DC potentials of 5.5 and 2.7 V, respectively. The specific capacitances, internal resistances, and
self-discharge characteristics of commercial activated carbon electrode supercapacitors were
investigated. Using cyclic voltammetry, the specific capacitances were determined to be 44.4 and
66.7 Fg−1 for distinct carbon electrode supercapacitors. The self-discharge characteristics were
investigated at both room temperature and close to the freezing point. The internal resistances of the
supercapacitors were calculated using the discharge curves at room temperature. The
microstructures of the electrode materials were determined using scanning electron microscopy.
Palavras-Chave:
activated carbon;
capacitance;
capacitors;
electric discharges;
electrodes;
energy storage;
microstructure;
powders;
scanning electron microscopy;
voltametry;
x-ray sources
GONSALVES, TAYARA C.; SILVA, FRANKS M.; VIEIRA, LIGIA S.; CASINI, JULIO C.S.; FARIA, RUBENS N. de.
Electrochemical characteristics and microstructures of activated carbon powder supercapacitors for energy storage.
Materials Science Forum,
v. 930,
p. 597-602,
2018.
DOI:
10.4028/www.scientific.net/MSF.930.597.
Disponível em: http://repositorio.ipen.br/handle/123456789/29309. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
-
KUPLICH, L.; DEPIANTI, J.B.; SOUZA, D.O.; CRUZ, P.C.M.; MEDEIROS, E.F.; ORLANDO, M.T.D.; MARTINEZ, L.G.
; ORTIZ, R.P..
Estudo sobre a energia de ligacao do CaCsub(2)Osub(4)-Hsub(2)O.
In: REUNIAO ANUAL DE USUARIOS DO LNLS, 17.,
18-19 de fevereiro, 2007,
Campinas, SP.
Resumo...
2007.
Palavras-Chave:
binding energy;
brazilian lnls;
calcium carbonates;
calcium;
chemical bonds;
covalence;
crystallography;
light sources;
oxalates;
storage rings;
structural chemical analysis;
synchrotron radiation sources;
synchrotron radiation;
x radiation;
x-ray diffraction;
x-ray sources
KUPLICH, L.; DEPIANTI, J.B.; SOUZA, D.O.; CRUZ, P.C.M.; MEDEIROS, E.F.; ORLANDO, M.T.D.; MARTINEZ, L.G.; ORTIZ, R.P.
Estudo sobre a energia de ligacao do CaCsub(2)Osub(4)-Hsub(2)O.
In:
REUNIAO ANUAL DE USUARIOS DO LNLS, 17.,
18-19 de fevereiro, 2007,
Campinas, SP.
Resumo...
2007.
Disponível em: http://repositorio.ipen.br/handle/123456789/22798. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CORREA, EDUARDO de L.; POTIENS, MARIA da P.A.
; CALDAS, LINDA V.E.
; VIVOLO, VITOR
.
Evaluation of ionization chambers in X-ray beams used for instruments calibration.
In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION,
October 19-24, 2008,
Buenos Aires, Argentina.
Proceedings...
2008.
Palavras-Chave:
ionization chambers;
x-ray sources;
beams;
quality control;
calibration;
biomedical radiography;
mammary glands;
radiology;
diagnostic techniques
CORREA, EDUARDO de L.; POTIENS, MARIA da P.A.; CALDAS, LINDA V.E.; VIVOLO, VITOR.
Evaluation of ionization chambers in X-ray beams used for instruments calibration.
In:
INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION,
October 19-24, 2008,
Buenos Aires, Argentina.
Proceedings...
2008.
Disponível em: http://repositorio.ipen.br/handle/123456789/15940. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PASSAMAI JUNIOR, JOSE L.; PASSOS, CARLOS A.C.; CRUZ, PAULO C.M. da; ORLANDO, MARCOS T.D.; PINHEIRO, CINTIA G.; CORREA, H.P.S.; MARTINEZ, L.G.
.
Evaluation of precursor on the Hg,Re-1223 polycrystalline samples.
In: REUNIAO ANUAL DE USUARIOS DO LNLS, 17.,
18-19 de fevereiro, 2007,
Campinas, SP.
Resumo...
2007.
p. 186.
Palavras-Chave:
brazilian lnls;
crystallography;
light sources;
mercury;
polycrystals;
rhenium;
storage rings;
structural chemical analysis;
synchrotron radiation sources;
synchrotron radiation;
x radiation;
x-ray diffraction;
x-ray sources
PASSAMAI JUNIOR, JOSE L.; PASSOS, CARLOS A.C.; CRUZ, PAULO C.M. da; ORLANDO, MARCOS T.D.; PINHEIRO, CINTIA G.; CORREA, H.P.S.; MARTINEZ, L.G.
Evaluation of precursor on the Hg,Re-1223 polycrystalline samples.
In:
REUNIAO ANUAL DE USUARIOS DO LNLS, 17.,
18-19 de fevereiro, 2007,
Campinas, SP.
Resumo...
2007.
p. 186.
Disponível em: http://repositorio.ipen.br/handle/123456789/22796. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, L.R.
; VIVOLO, V.
; NAVARRO, M.V.T.; XAVIER, M.
; POTIENS, M.P.A.
.
Filtration influence in a constant potential X-ray machine peak voltage measurements.
Brazilian Journal of Radiation Sciences,
v. 05,
n. 02,
p. 01-09,
2017.
Abstract:
This work shows the peak voltage measurements for several beam filtrations used in diagnostic radiology, using two types of non-invasive detectors; a voltage meter and a high-resolution spectrometer. The technique chosen for the voltage peak measurements with the spectrometer was the endpoint. The results were compared to the measured ones and showed good similarity to the nominal values. However the voltage meter detector used in this work pre-sented errors for heavier filtrations.
Palavras-Chave:
beams;
calibration;
electric potential;
peaks;
radiology;
semiconductor detectors;
spectroscopy;
x-ray dosimetry;
x-ray sources
SANTOS, L.R.; VIVOLO, V.; NAVARRO, M.V.T.; XAVIER, M.; POTIENS, M.P.A.
Filtration influence in a constant potential X-ray machine peak voltage measurements.
Brazilian Journal of Radiation Sciences,
v. 05,
n. 02,
p. 01-09,
2017.
Disponível em: http://repositorio.ipen.br/handle/123456789/28570. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
POTIENS, M.P.A.
; VIVOLO, V.
; MIRANDA, J.A.; CALDAS, L.V.E.
.
Flat ionization chambers as monitors in x-ray beams.
In: INTERNATIONAL MEETING ON APPLIED PHYSICS, 1st,
Oct. 13-18, 2003,
Badajoz, Espanha.
Proceedings...
2003.
Palavras-Chave:
ionization chambers;
phantoms;
dosemeters;
x-ray sources;
beam monitors;
calibration;
diagnosis;
radiology
POTIENS, M.P.A.; VIVOLO, V.; MIRANDA, J.A.; CALDAS, L.V.E.
Flat ionization chambers as monitors in x-ray beams.
In:
INTERNATIONAL MEETING ON APPLIED PHYSICS, 1st,
Oct. 13-18, 2003,
Badajoz, Espanha.
Proceedings...
2003.
Disponível em: http://repositorio.ipen.br/handle/123456789/15433. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
FRANCO, MARGARETH K.K.D.
; YOKAICHIYA, FABIANO; KARDJILOV, NIKOLAY; FERRAZ, ANTONIO C. de O..
Microfocus X-ray imaging of Brazil nuts for quality control / Images de raios-x (Microfocus) no controle de qualidade de castanha do Brasil.
Semina: Ciencias Agrárias, Londrina,
v. 36,
n. 4,
p. 2565-2576,
2015.
Palavras-Chave:
computerized tomography;
cross sections;
fungi;
morphology;
nuts;
quality control;
x-ray sources;
brazil;
images
FRANCO, MARGARETH K.K.D.; YOKAICHIYA, FABIANO; KARDJILOV, NIKOLAY; FERRAZ, ANTONIO C. de O.
Microfocus X-ray imaging of Brazil nuts for quality control.
Semina: Ciencias Agrárias, Londrina,
v. 36,
n. 4,
p. 2565-2576,
2015.
Disponível em: http://repositorio.ipen.br/handle/123456789/25443. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
-
Todo o repositório
-
Esta comunidade
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o
significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo
será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.