Navegação Periódicos - Artigos por Autores IPEN "YORIYAZ, H."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 19230

    VIANA, R.S.; AGASTHYA, G.A.; YORIYAZ, H. ; KAPADIA, A.J.. 3D element imaging using NSECT for the detection of renal cancer: a simulation study in MCNP. Physics in Medicine and Biology, v. 58, n. 17, p. 5867-5883, 2013.

    Palavras-Chave: kidneys; carcinomas; computerized tomography; three-dimensional calculations; neutron emission; stimulated emission; simulation; m codes

  • IPEN-DOC 07062

    YORIYAZ, H. ; SANTOS, A.; STABIN, M.G.; CABEZAS, R. . Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code. Medical Physics, v. 27, n. 7, p. 1555-1562, 2000.

    Palavras-Chave: internal irradiation; spatial dose distributions; dosimetry; phantoms; radiation transport; radionuclide kinetics; monte carlo method; computerized simulation; numerical solution; biological models

  • IPEN-DOC 09562

    LIMA, R.B.; YORIYAZ, H. ; HERNANDES, A.C.; MADI FILHO, T. . Avaliacao experimental do fluxo de neutrons de um irradiador com fontes de AmBe e sua possibilidade de uso em analise de materiais. Revista Brasileira de Pesquisa e Desenvolvimento, v. 5, n. 2, p. 43-48, 2003.

    Palavras-Chave: neutron flux; neutrons; irradiation devices; radiation sources; americium; beryllium; nondestructive analysis; neutron activation analysis; experimental data; monte carlo method; comparative evaluations

  • IPEN-DOC 09332

    UMBEHAUN, P.E. ; YORIYAZ, H. ; YAMAGUCHI, M. . Calculo de temperatura no silicio irradiado no reator IEA-R1. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 2, p. 315-318, 2002.

    Palavras-Chave: silicon; irradiation; heat transfer; monte carlo method; m codes; temperature measurement; temperature distribution; temperature range 0273-0400 k; temperature range 0400-1000 k; thermal hydraulics

  • IPEN-DOC 08664

    SILVA, M.A.; SUZUKI, M.F. ; GUIMARAES, M.I.C.C.; BUCHPIGUEL, C.A.; ROGERO, J.R. ; YORIYAZ, H. ; SIQUEIRA, P.T.D. ; COELHO, P.R.P. ; OKAZAKI, K. . Comparative in vivo and in vitro study of the cytogenetic effects of sup(153)Sm-EDTMP in lymphocytes of patients with bone metastases. Cellular and Molecular Biology, v. 48, n. 5, p. 493-499, 2002.

    Palavras-Chave: biological radiation effects; radiopharmaceuticals; samarium 153; beta particles; lymphocytes; chromosomal aberrations; skeleton; metastases; in vitro; in vivo; dose-response relationships

  • IPEN-DOC 17279

    COELHO, T.S.; FERNANDES, M.A.R.; YORIYAZ, H. ; ANTONIO, P.L.. A complete dosimetric characterization of two sup(90)Sr-sup(90)Y dermatology applicators. Nuclear Instruments and Methods in Physics Research, A, v. 632, n. 1, p. 147-151, 2011.

    Palavras-Chave: radiotherapy; strontium 90; yttrium 90; dosimetry; skin diseases; monte carlo method

  • IPEN-DOC 25969

    MAZER, A.C. ; NAKANDAKARI, M.V.N.; RIBEIRO, V.A.B.; SIQUEIRA, P.T.D. ; SHORTO, J.M.B. ; YORIYAZ, H. . Computational model of a 3D dosimetry system - ArcCHECK®. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-11, 2019. DOI: 10.15392/bjrs.v7i2A.675

    Abstract: Ionizing radiation therapies have been improving over the years, becoming more specific for each patient. Thereby, as the treatment planning system (TPS) complexities increases, the quality assurance (QA) methods have to be in constant evolution. One of the techniques that demand great complexity is the Volumetric Modulated Arc Therapy (VMAT), and one possible way to VMAT commissioning is using 3D dosimetry systems. Recently a new 3D dosimetry system called ArcCHECK had been developed and commercialized mainly for VMAT quality assurance. It is water-equivalent and composed by an array of 1386 diodes arranged in a helical pattern. Since simulation methods, like Monte Carlo method, ensure highly accurate results, MCNP (A General Monte Carlo N-Particle Transport Code System) is totally reliable for problems that involve radiation transport. This work presents two computational models for Monte Carlo simulations to predict detection responses in the QA procedure using the ArcCHECK. The computational models were validated comparing the system responses obtained from MCNP6 simulations against measured responses due to a 6 MeV clinical photon beam from a Linear Accelerator. 2D dose maps were reported here with good agreement between simulated and measured values.

    Palavras-Chave: radiotherapy; dosimetry; quality assurance; mathematical models; monte carlo method; programming

  • IPEN-DOC 25716

    BRANCO, I.S.L.; LIMA, F.A.; ANTUNES, P.C.G. ; YORIYAZ, H. ; BELLEZZO, M.; FONSECA, G.P.; BORGUEZAN NETO, E.; BRUNO, A.C.; SANTO, M.L.R.; BARBI, G.L.; BORGES, L.F.; BERTUCCI, E.C.; VIANI, G.A.; PAVONI, J.F.. Desenvolvimento de software de cálculo de dose pontual em braquiterapia baseado em simulações de Monte Carlo / Software development of point dose calculation in brachytherapy based on Monte Carlo simulations. Revista Brasileira de Física Médica, v. 12, n. 1, p. 2-9, 2018. DOI: 10.29384/rbfm.2018.v12.n1.p2-9

    Abstract: Em braquiterapia, o controle de qualidade é necessário para garantir a consistência entre a dose clínica prescrita para o tratamento e a dose real administrada ao paciente. Entre os procedimentos necessários na adoção de um programa de garantia de qualidade se enquadra a verificação do sistema de planejamento e processo de planejamento e controle de qualidade rotineiro. Visando os processos de verificação do sistema de planejamento, inicialmente, neste trabalho uma fonte de 192Ir GammaMed Plus foi caracterizada com base em parâmetros estabelecidos pelo Task Group 43 (TG-43) da AAPM. Para avaliação de seus parâmetros dosimétricos, a fonte foi simulada através do Método de Monte Carlo, com o código MCNP6 (Monte Carlo NParticle). Os valores de distribuição de dose obtidos a partir da simulação foram comparados com os dados fornecidos pela literatura. As simulações serviram de base para o desenvolvimento de um software de código aberto, o BrachySure, que permite comparar a dose pontual calculada pelo sistema de planejamento e por Monte Carlo em um caso clínico real. Os resultados obtidos na caracterização da fonte, mostram uma ótima concordância com os dados bibliográficos, apresentando diferenças próximas à incerteza associada as simulações. O erro relativo máximo encontrado para a malha virtual simulada (mesh) foi de 0.31%, quando comparada com os valores de outros autores, a diferença relativa apresentou valores em torno de 1% para a maior parte dos pontos da malha. O software BrachySure foi pré-validado e apresentou um erro sistemático ainda a ser utilizado como objeto de pesquisa (em torno de 8%), além disso, este software forneceu uma dupla verificação de dose pontual de maneira rápida e simples, contribuindo para organização dos dados e registro de tratamentos. Intenta-se com os dados obtidos neste trabalho impulsionar o desenvolvimento de novas metodologias para uso na rotina clínica, que contribuam na incorporação de novas estimativas de doses com maior exatidão.

    Palavras-Chave: brachytherapy; iridium 192; monte carlo method; therapy; computer codes; dosimetry

  • IPEN-DOC 19659

    FONSECA, G.P.; RUBO, R.A.; MINAMISAWA, R.A.; SANTOS, G.R. dos; ANTUNES, P.C.G.; YORIYAZ, H. . Determination of transit dose profile for a sup(192)Ir HDR source. Medical Physics, v. 40, n. 5, p. 051717-1 - 051717-8, 2013.

    Palavras-Chave: brachytherapy; computerized simulation; distribution; dose rates; doses; dosimetry; films; iridium 192; irradiation; monte carlo method; optical fibers; radiation sources

  • IPEN-DOC 29096

    BURIN, A.L. ; BRANCO, I.S.L. ; YORIYAZ, H. . Determination of WER and WET equivalence estimators for proton beams in the therapeutic energy range using MCNP6.1 and TOPAS codes. Radiation Physics and Chemistry, v. 203, n. Part A, p. 1-9, 2023. DOI: 10.1016/j.radphyschem.2022.110606

    Abstract: To use the dosimetric advantages that proton therapy provides, the exact knowledge of the range and its associated parameters of the beam is essential. Since the human body is composed of several tissues whose composition and density differ from water it is important to relate the range in water to the range in those tissues. Those range associated parameters are the Water Equivalent Ratio (WER) and Water Equivalent Thickness (WET). This work presents the Range, WER and WET values obtained from the simulations using the Monte Carlo codes MCNP6.1 and TOPAS for several tissue-equivalent materials, which are materials that reproduce the radiation behavior of the human tissues in a phantom. Simulations have been done in the therapeutic proton energy range from 70 to 225 MeV. Therefore, the main objective of this work is to provide and contribute to the improvement of dose calculation in proton therapy, more specifically in the calculation of WER and WET in tissue equivalent medium. The results showed good agreement between codes, presenting only small differences less than 1.9% in the cortical bone, but they did not affect the dose calculation in the therapeutic range used in this study.

    Palavras-Chave: proton beams; thickness; water; monte carlo method; particles; simulation

  • IPEN-DOC 19646

    TARDELLI, T.C.; STECHER, L.C.; COELHO, T.S.; CASTRO, V.A. de; CAVALIERI, T.A.; MENZEL, F.; GIAROLA, R.S.; DOMINGOS, D.B.; YORIYAZ, H. . Diferenças entre bibliotecas de seções de choque para dosimetria de nêutrons / Diferences between cross-section libraries for neutron dosimetry. Scientia Plena, v. 9, n. 8, p. 081007-1 - 081007-13, 2013.

    Palavras-Chave: neutron dosimetry; cross sections; monte carlo method; nuclear data collections

  • IPEN-DOC 16597

    CORREA, S.C.A.; SOUZA, E.M.; SILVA, A.X.; YORIYAZ, H. ; LOPES, R.T.. Dose and risk evaluation in thoracic radiology using male and female voxel phantoms. International Journal of Low Radiation, v. 7, n. 2, p. 81-97, 2010.

    Palavras-Chave: chest; biomedical radiography; radiation doses; hazards; biological models; phantoms; females; males

  • IPEN-DOC 13746

    CORREA, S.C.A.; SOUZA, E.M.; SILVA, A.X.; LOPES, R.T.; YORIYAZ, H. . Dose-image quality study in digital chest radiography using Monte Carlo simulation. Applied Radiation and Isotopes, v. 66, n. 9, p. 1213-1217, 2008.

    Palavras-Chave: chest; biomedical radiography; radiation dose; image processing; quality assurance; simulation; monte carlo method; m codes; digital systems

  • IPEN-DOC 11387

    MADI FILHO, TUFIC ; LIMA, RUY B. de; YORIYAZ, H. ; HERNANDES, ANTONIO C.. Experimental and Monte Carlo evaluation of the neutron flux of an assembly with two AmBe sources. Radiation Protection Dosimetry, v. 115, n. 1-4, p. 412-414, 2005.

    Palavras-Chave: irradiation devices; neutron flux; neutron sources; neutron activation analysis; monte carlo method

  • IPEN-DOC 26469

    FONSECA, T.C.F.; ANTUNES, P.C.G. ; BELO, M.C.L.; BASTOS, F.; CAMPOS, T.P.; GERALDO, J.M.; MENDES, A.M.; MENDES, B.M.; PAIXÃO, L.; SANTANA, P.C.; SENIWAL, B.; SQUAIR, P.L.; YORIYAZ, H. . MCMEG: intercomparison exercise on prostate radiotherapy dose assessment. Radiation Physics and Chemistry, v. 167, p. 1-7, 2020. DOI: 10.1016/j.radphyschem.2019.04.045

    Abstract: The improvement of the Monte Carlo (MC) community skills on computational simulations in Medical Physics is crucial to the field of radiotherapy as well as radiology. The Monte Carlo Modelling Expert Group (MCMEG) is an expert network specialized in MC radiation transport modelling and simulation applied to the radiation protection and dosimetry research fields. The MCMEG addressed a multigroup dosimetric intercomparison exercise for modelling and simulating a case of prostate radiation therapy (RT) protocol. This intercomparison was launched in order to obtain the dose distribution in the prostate target volume and in the neighboring organs. Dose assessments were achieved by using TLDs. A protocol using two pair of parallel-opposed fields were planned and performed with Alderson-Rando Pelvic Phantom. The assessed organs at risk were the urinary bladder, rectum and right and left femur heads. The RT simulations were performed using the MCNPx, MCNP6 and egs++ and BEAMnrc/DOSXYZnrc modules of EGSnrc Monte Carlo codes. The dose to the target volume, mean doses and standard deviation in the organs at risk, and dose volume data were computed. A comparison between the simulated results and the experimental values obtained from TLD measurements was made. In some cases the results obtained using MC simulations showed large deviations in comparison to the results obtained from the TLD measurements and these variations can be explained by the difficulties in the modelling of the geometry, selection of MC parameters required for the simulations and the statistical errors and inaccuracies in experimental measurements. Even though, the exercise has been a great opportunity for the MC groups to learn and share the main difficulties found during the modelling and the analysis of the results. Concerned to the obtained variations, the MCMEG team consider that this was expected for the level of complexity of the exercise and must be studied by the MC groups.

    Palavras-Chave: monte carlo method; simulation; radiotherapy; prostate; irradiation; formation damage; phantoms; interlaboratory comparisons; radiation doses; therapy; radiology

  • IPEN-DOC 09342

    VIEIRA, W.J.; CLARO, L.H.; YORIYAZ, H. . MCNP isothermal reactivity calculations of the IPEN/MB-01 zero-power reactor. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 2, p. 450-453, 2002.

    Palavras-Chave: zero power reactors; ipen-mb-1 reactor; reactivity; reactivity coefficients; monte carlo method; m codes; temperature range 0273-0400 k; cross sections

  • IPEN-DOC 09422

    SANCHEZ, A.; SANTOS, A.; YORIYAZ, H. . Modelagem de olho humano para projeto de simuladores oftalmicos para aplicacoes clinicas. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 2, p. 1439-1443, 2002.

    Palavras-Chave: eyes; simulators; radiation sources; monte carlo method; m codes; radiation dose distributions; melanomas; neoplasms; radiotherapy; ophthalmology

  • IPEN-DOC 08415

    YORIYAZ, H. ; STABIN, M.G.; SANTOS, A.. Monte Carlo MCNP-4B-based absorbed dose distribution estimates for patient-specific dosimetry. Journal of Nuclear Medicine, v. 42, n. 4, p. 662-669, 2001.

    Palavras-Chave: radioimmunotherapy; dosimetry; spatial dose distributions; patients; monte carlo method; computerized simulation; computer codes; radiation transport

  • IPEN-DOC 09258

    OLIVEIRA, C.; YORIYAZ, H. ; OLIVEIRA, M.C.; FERREIRA, L.M.. Monte Carlo simulation for dose distribution calculations in a CT-based phantom at the Portuguese gamma irradiation facility. Nuclear Instruments and Methods in Physics Research, v. 213, Section B, p. 662-665, 2004.

    Palavras-Chave: monte carlo method; computerized simulation; radiation dose distributions; computerized tomography; phantoms; s codes; gamma radiation; irradiation plants; dosimetry

  • IPEN-DOC 06659

    MARDIROSSIAN, G.; TAGESSON, M.; BLANCO, P.; BOUCHET, L.G.; STABIN, M.G.; YORIYAZ, H. ; BAZA, S.; LJUNGBERG, M.; STRAND, S.E.; BRILL, A.B.. A new rectal model for dosimetry applications. Journal of Nuclear Medicine, v. 40, n. 9, p. 1524-1531, 1999.

    Palavras-Chave: reference man; phantoms; rectum; large intestine; bladder; prostate; simulation; monte carlo method; radiation doses; radiopharmaceuticals

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.