JavaScript is disabled for your browser. Some features of this site may not work without it.
Navegação Periódicos - Artigos por assunto "luminescent dosemeters"
-
VILLANI, DANIEL
; MORENO, CAROLINA dos S.; SAKURABA, ROBERTO K.; CAMPOS, LETICIA L.
.
Application of OSL dosimetry and 3D printed phantom for comparison of calculation algorithms for VMAT treatment planning.
QUARKS: Brazilian Electronic Journal of Physics, Chemistry and Material Science,
v. 1,
n. 1,
p. 30-39,
2019.
DOI:
10.34019/2674-9688.2019.v1.28227
Abstract:
The application of new commercial and industrial technologies in the fields of dosimetry and
medical physics is of great interest to the scientific community, both to validate existing
protocols and to develop new methodologies. The popularization of 3D printing techniques
has been analyzed as a great advantage in quality control in complex treatment techniques,
such as radiotherapy and the development of patient simulators. Portable dosimetry systems
such as Landauer MicroStar OSL system are versatile and their use in quality control is of
great importance. The aim of this paper is to compare two of the most used dose calculation
algorithms used in Varian Eclipse TPS – AAA and Acuros XB – for treatment planning of
multiple brain metastases using a 3D printed anthropomorphic phantom and the OSL InLight
system for experimental dosimetry validation. A 3D printed anthropomorphic skull phantom
was submitted to a CT scan and planed five target volumes. In order of comparison, two
dose calculations were performed in the Varian Eclipse 13.6 TPS with "Alabama technique",
using the Varian’s AAA and AXB algorithms, and treatment delivered with 6 MV photon beam
of a Varian TrueBeam linear accelerator. Landauer nanoDot dosimeters were positioned
inside each of the five target volumes planned and the experimental dosimetric results were
compared with the algorithms’ calculated doses. The findings of this work indicate that
ACUROS XB calculates more accurate doses compared with AAA, with all the experimental
agreements better than 96.0 %, probably because of the heterogeneity corrections. The
uncertainty analysis of the InLight system device is enough to sustain the dosimetric
uncertainties below 3.0 %, validating the results.
Palavras-Chave:
dosimetry;
luminescent dosemeters;
phantoms;
calculation methods;
algorithms;
radiation doses;
radiation dose distributions;
radiotherapy;
planning;
brain;
metastases
VILLANI, DANIEL; MORENO, CAROLINA dos S.; SAKURABA, ROBERTO K.; CAMPOS, LETICIA L.
Application of OSL dosimetry and 3D printed phantom for comparison of calculation algorithms for VMAT treatment planning.
QUARKS: Brazilian Electronic Journal of Physics, Chemistry and Material Science,
v. 1,
n. 1,
p. 30-39,
2019.
DOI:
10.34019/2674-9688.2019.v1.28227.
Disponível em: http://repositorio.ipen.br/handle/123456789/31374. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VILA, GUSTAVO B.; CALDAS, L.V.E.
.
Brazilian biominerals for high-dose dosimetry.
Radiation Measurements,
v. 46,
p. 1900-1902,
2011.
Palavras-Chave:
biological materials;
minerals;
sample preparation;
thermoluminescence;
luminescent dosemeters;
stimulated emission;
gamma radiation;
dose rates
VILA, GUSTAVO B.; CALDAS, L.V.E.
Brazilian biominerals for high-dose dosimetry.
Radiation Measurements,
v. 46,
p. 1900-1902,
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/4429. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GRONCHI, CLAUDIA; CALDAS, LINDA V.E.
.
Detectores de Alsub(2)Osub(3):C inlight expostos a radiação ultravioleta de um processo de soldagem elétrica.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 13,
n. 1,
p. 80-94,
2011.
Palavras-Chave:
aluminium oxides;
dosimetry;
luminescent dosemeters;
ultraviolet radiation;
welding
GRONCHI, CLAUDIA; CALDAS, LINDA V.E.
Detectores de Alsub(2)Osub(3):C inlight expostos a radiação ultravioleta de um processo de soldagem elétrica.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 13,
n. 1,
p. 80-94,
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/4353. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CARVALHO, G.S.M.; FERREIRA, P.Z.; DANTAS, N.O.; SILVA, A.C.A.; PERINI, A.P.; CALDAS, L.V.E.
; CARRERA, B.N.S.; WATANABE, S.; NEVES, L.P.
.
Evaluation of glasses containing cadmium for high dose dosimetry by the thermoluminescence technique.
Brazilian Journal of Radiation Sciences,
v. 05,
n. 03-A,
p. 01-06,
2017.
DOI:
10.15392/bjrs.v5i3.285
Abstract:
New glass matrices were evaluated for high dose dosimetry by the thermoluminescence technique. Their nominal com-position are 20Li2CO3.10Al2O3.15CdO.55B2O3 and 20Li2CO3.10Al2O3.20CdO.50B2O3 (mol%). The glass matrices were irradiated with different doses: 50, 100, 200, 500, 700 and 900 Gy, and the thermoluminescence emission curves were obtained for each of these values. The results show a great potential of using these matrices in high dose dosime-try.
Palavras-Chave:
cadmium;
glass scintillators;
luminescent dosemeters;
quality control;
radiation dose units;
radiation protection;
thermoluminescence
CARVALHO, G.S.M.; FERREIRA, P.Z.; DANTAS, N.O.; SILVA, A.C.A.; PERINI, A.P.; CALDAS, L.V.E.; CARRERA, B.N.S.; WATANABE, S.; NEVES, L.P.
Evaluation of glasses containing cadmium for high dose dosimetry by the thermoluminescence technique.
Brazilian Journal of Radiation Sciences,
v. 05,
n. 03-A,
p. 01-06,
2017.
DOI:
10.15392/bjrs.v5i3.285.
Disponível em: http://repositorio.ipen.br/handle/123456789/28464. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
YOSHIZUMI, MAIRA T.; XAVIER, MARCOS
; CALDAS, LINDA V.E.
.
Influence of thermal and optical treatments on the OSL response of Alsub(2)Osub(3):C pellets using blue light stimulation.
IEEE Transactions on Nuclear Science,
v. 60,
n. 2,
p. 979-982,
2013.
Palavras-Chave:
aluminium oxides;
carbon;
pellets;
optics;
bleaching;
annealing;
luminescent dosemeters
YOSHIZUMI, MAIRA T.; XAVIER, MARCOS; CALDAS, LINDA V.E.
Influence of thermal and optical treatments on the OSL response of Alsub(2)Osub(3):C pellets using blue light stimulation.
IEEE Transactions on Nuclear Science,
v. 60,
n. 2,
p. 979-982,
2013.
Disponível em: http://repositorio.ipen.br/handle/123456789/4037. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PINTO, TERESA N.O.; ANTONIO, PATRICIA L.; CALDAS, LINDA V.E.
.
Measuring TL and OSL of beta radioisotopes inside a glove box at a radiopharmacy laboratory.
Radiation Measurements,
v. 46,
p. 1847-1850,
2011.
Palavras-Chave:
thermoluminescent dosimetry;
luminescent dosemeters;
stimulated emission;
personnel monitoring;
gloveboxes;
laboratories;
radiopharmaceuticals;
radiations;
beta sources
PINTO, TERESA N.O.; ANTONIO, PATRICIA L.; CALDAS, LINDA V.E.
Measuring TL and OSL of beta radioisotopes inside a glove box at a radiopharmacy laboratory.
Radiation Measurements,
v. 46,
p. 1847-1850,
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/4425. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VALENCA, JOAO V.B.; SILVA, ANIELLE C.A.; DANTAS, NOELIO O.; CALDAS, LINDA V.E.
; DERRICO, FRANCESCO; SOUZA, SUSANA O..
Optically stimulated luminescence of the [20% Li2CO3 + x% K2CO3 + (80 - x)% B2O3] glass system.
Journal of Luminescence,
v. 200,
p. 248-253,
2018.
DOI:
10.1016/j.jlumin.2018.03.060
Abstract:
This study analyzed the optically simulated luminescence (OSL) of borate glasses containing lithium carbonate and potassium carbonate. Borate glasses present desirable characteristics for dosimetry and have been extensively analyzed in relation to thermoluminescence (TL). Five formulations containing 20% of Li2CO3 and different amounts of B2O3 and K2CO3 were produced. Their OSL signal was analyzed following exposure to beta particles. The decay pattern typical of continuous wave stimulation (CW-OSL) was observed for all compositions. Depending on the parameter chosen to normalize the dose-response curve, the sensitivity range changed. If the initial OSL intensity was chosen as reference, the composition containing 65% B2O3 and 15% K2CO3 (named L15KB) presented the most intense signal. However, if the total area below the curve was considered, the composition containing 70% B2O3 and 10% K2CO3 (named L10KB) was the most sensitive. A comparison of the OSL decay for the two quoted compositions, after pre-heating to 200 °C for 10 s prior to the OSL readout, showed a slight change in the decay pattern compared to the absence of pre-heating. The pre-heating treatments also showed the correlation between the shallow traps and the fast component of the OSL decay for L15KB. For all compositions, an increase in dose implied an increase in emitted signal, and no saturation was observed between 0.1 Gy and 7 Gy.
Palavras-Chave:
luminescence;
luminescent dosemeters;
borates;
boron oxides;
thermoluminescence;
x-ray diffraction;
differential thermal analysis;
lithium carbonates;
potassium carbonates
VALENCA, JOAO V.B.; SILVA, ANIELLE C.A.; DANTAS, NOELIO O.; CALDAS, LINDA V.E.; DERRICO, FRANCESCO; SOUZA, SUSANA O.
Optically stimulated luminescence of the [20% Li2CO3 + x% K2CO3 + (80 - x)% B2O3] glass system.
Journal of Luminescence,
v. 200,
p. 248-253,
2018.
DOI:
10.1016/j.jlumin.2018.03.060.
Disponível em: http://repositorio.ipen.br/handle/123456789/29015. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ROCHA, F.D.G.
; VILLANI, D.
; CAMPOS, V.P.
; NOGUEIRA, M.S.; GOULART, M.E.
; SICHITO, V.A.; CAMPOS, L.L.
.
Performance of TL and OSL techniques using CaSO4 and Al2O3 dosimeters for mean glandular dose (MGD) and entrance surface skin dose (ESD) determination in a digital mammographic unit as alternative dosimeters.
Radiation Physics and Chemistry,
v. 155,
SI,
p. 48-52,
2019.
DOI:
10.1016/j.radphyschem.2018.06.037
Abstract:
The mammography is the most important and simple tool in the diagnosis of breast diseases in women. In digital
mammography, the process of image acquisition, display and storage are separated which allows optimization of
each. Despite the innumerous advantages of this technique, such as an accurate diagnosis for women with dense
breast, it was noticed an increase of radiation doses to obtain the images by this system. As with any examination
that includes x-rays, there is always a small stochastic risk of inducing cancer, it is therefore important to
evaluate the risk from the dose delivered to the patient during the screening process. The mean glandular dose
within the breast is the recommended quantity to evaluate the risk from radiation to the breast. To guarantee
proper conditions of protection for patients, the radiation dose should be as low as reasonably achievable
possible and simultaneously compatible with image quality requirements. Thus, this work proposes the use of
the thermoluminescent (TL) CaSO4:Dy sintered discs, produced at IPEN, widely used in individual, environmental
and area monitoring in Brazil, and Al2O3:C optically stimulated luminescence (OSL) ‘dot’ dosimeters,
manufactured by Landauer® Inc., as application as easy-to-use and low cost alternative dosimeters to evaluate
the entrance skin doses (ESD) delivered to patients, the half value layer (HVL) and the mean glandular doses
(MGD) in a mammographic digital unit, comparing these two techniques with the results obtained using an Allin-
one QC meter. The results obtained demonstrated that the TL and OSL dosimetry systems and the CaSO4 and
Al2O3 dosimeters used are able to evaluate the entrance skin dose as well as mean glandular doses in a digital
mammographic unit accurately within the requirements, and they can be considered a practical, simple, easy-touse
and low cost tools for verification of these items in a Quality Assurance Program.
Palavras-Chave:
thermoluminescence;
mammary glands;
images;
diagnosis;
neoplasms;
luminescence;
luminescent dosemeters;
dosimetry;
phantoms;
pmma;
calcium sulfates;
anhydrite;
aluminium oxides
ROCHA, F.D.G.; VILLANI, D.; CAMPOS, V.P.; NOGUEIRA, M.S.; GOULART, M.E.; SICHITO, V.A.; CAMPOS, L.L.
Performance of TL and OSL techniques using CaSO4 and Al2O3 dosimeters for mean glandular dose (MGD) and entrance surface skin dose (ESD) determination in a digital mammographic unit as alternative dosimeters.
Radiation Physics and Chemistry,
v. 155,
p. 48-52,
2019.
SI,
DOI:
10.1016/j.radphyschem.2018.06.037.
Disponível em: http://repositorio.ipen.br/handle/123456789/29831. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
GRONCHI, CLÁUDIA C.; CALDAS, LINDA V.E.
.
PTOSL response pf commercial Alsub(2Osub(3)C detectors to ultraviolet radiation.
Radiation Protection Dosimetry,
v. 154,
n. 1,
p. 117-120,
2013.
Palavras-Chave:
aluminium oxides;
luminescent dosemeters;
radiation detection;
ultraviolet radiation
GRONCHI, CLÁUDIA C.; CALDAS, LINDA V.E.
PTOSL response pf commercial Alsub(2Osub(3)C detectors to ultraviolet radiation.
Radiation Protection Dosimetry,
v. 154,
n. 1,
p. 117-120,
2013.
Disponível em: http://repositorio.ipen.br/handle/123456789/4104. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MATSUSHIMA, LUCIANA C.; VENEZIANI, GLAUCO R.; CAMPOS, LETICIA L.
.
Study of optically stimulated luminescence of LiF:Mg, Ti for beta and gamma dosimetry.
Radiation Measurements,
v. 56,
n. ,
Radiation Measurements,
p. 365-368,
2013.
Palavras-Chave:
beta dosimetry;
luminescent dosemeters;
lithium fluorides;
doped materials;
magnesium;
titanium;
beta sources;
gamma radiation
MATSUSHIMA, LUCIANA C.; VENEZIANI, GLAUCO R.; CAMPOS, LETICIA L.
Study of optically stimulated luminescence of LiF:Mg, Ti for beta and gamma dosimetry.
Radiation Measurements,
v. 56,
n. ,
p. 365-368,
2013.
Radiation Measurements.
Disponível em: http://repositorio.ipen.br/handle/123456789/8575. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MAIA, ANA F.; CALDAS, LINDA V.E.
.
TANDEM study with thermoluminescent materials in standard diagnostic beams.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 9,
n. 3,
p. 97-100,
2007.
Palavras-Chave:
beams;
dosimetry;
luminescent dosemeters;
phosphorus;
radiation protection;
thermoluminescent dosemeters;
thermoluminescent dosimetry
MAIA, ANA F.; CALDAS, LINDA V.E.
TANDEM study with thermoluminescent materials in standard diagnostic beams.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 9,
n. 3,
p. 97-100,
2007.
Disponível em: http://repositorio.ipen.br/handle/123456789/5156. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MATSUSHIMA, LUCIANA C.
; VENEZIANI, GLAUCO R.
; SAKURABA, ROBERTO K.; CRUZ, JOSE C.; CAMPOS, LETICIA L.
.
TL and OSL dose response of LiF:Mg, Ti and Alsub(2)Osub(3):C dosimeters using a PMMA phantom for IMRT technique quality assurance.
Applied Radiation and Isotopes,
v. 100,
p. 7-10,
2015.
Palavras-Chave:
lithium fluorides;
magnesium;
titanium;
aluminium oxides;
thermoluminescent dosimetry;
luminescent dosemeters;
pmma;
phantoms;
radiotherapy;
radiation dose distributions
MATSUSHIMA, LUCIANA C.; VENEZIANI, GLAUCO R.; SAKURABA, ROBERTO K.; CRUZ, JOSE C.; CAMPOS, LETICIA L.
TL and OSL dose response of LiF:Mg, Ti and Alsub(2)Osub(3):C dosimeters using a PMMA phantom for IMRT technique quality assurance.
Applied Radiation and Isotopes,
v. 100,
p. 7-10,
2015.
Disponível em: http://repositorio.ipen.br/handle/123456789/23846. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
PIRES, E.L.; TATUMI, S.H.; MITTANI, J.C.R.; KINOSHITA, A.; BAFFA, O.; CALDAS, L.V.E.
.
TL, OSL and ESR properties of nanostructured KAlSiSUB(3)OSUB(8):Mn Glass.
Radiation Measurements,
v. 46,
p. 1492-1495,
2011.
Palavras-Chave:
thermoluminescent dosimetry;
luminescent dosemeters;
stimulated emission;
nanostructures;
particles;
aluminium silicates;
manganese;
glass;
sol-gel process;
transmission electron microscopy;
electron spin resonance
PIRES, E.L.; TATUMI, S.H.; MITTANI, J.C.R.; KINOSHITA, A.; BAFFA, O.; CALDAS, L.V.E.
TL, OSL and ESR properties of nanostructured KAlSiSUB(3)OSUB(8):Mn Glass.
Radiation Measurements,
v. 46,
p. 1492-1495,
2011.
Disponível em: http://repositorio.ipen.br/handle/123456789/4420. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
-
Todo o repositório
-
Esta coleção
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.