Navegação Periódicos - Artigos por assunto "lutetium 177"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 14075

    ARAUJO, E.B. de ; CALDEIRA FILHO, J.S. ; NAGAMATI, L.T. ; MURAMOTO, E. ; COLTURATO, M.T. ; COUTO, R.M. ; PUJATTI, P.B. ; SILVA, C.P.G. ; MENGATTI, J. . A comparative study of sup(131)I and sup(177)Lu labeled somatostatin analogues for therapy of neuroendocrine tumours. Applied Radiation and Isotopes, v. 67, p. 277-233, 2009.

    Palavras-Chave: neoplasms; nervous system diseases; somatostatin; labelling; targets; therapy; indium 131; lutetium 177

  • IPEN-DOC 21757

    MASSICANO, ADRIANA V.F. ; PUJATTI, PRISCILLA B.; ALCARDE, LAIS F. ; SUZUKI, MIRIAM F. ; SPENCER, PATRICK J. ; ARAUJO, ELAINE B. . Development and biological studies of sup(177)Lu-DOTA-rituximab for the treatment of non-hodgkin's lymphoma. Current Radiopharmaceuticals, v. 9, p. 54-63, 2016. DOI: 10.2174/1874471008666150313103849

    Palavras-Chave: lutetium 177; radiopharmaceuticals; radioimmunotherapy; lymphomas; therapy; mice; animals; antibodies; in vivo

  • IPEN-DOC 16664

    PUJATTI, P.B.; SANTOS, J.S.; MASSICANO, A.V.F.; MENGATTI, J. ; ARAUJO, E.B. de . Development of a new bombesin analog radiolabelled with lutetium-177: in vivo evaluation of the biological properties in BALB-C mice. Cellular and Molecular Biology, v. 56, n. 2, p. 18-24, 2010.

    Palavras-Chave: peptides; gastrin; receptors; neoplasms; labelling; radiopharmaceuticals; lutetium 177; in vivo; mice

  • IPEN-DOC 21323

    KOVACS, LUCIANA ; TASSANO, MARCOS; CABRERA, MIREL; ZAMBONI, CIBELE B. ; FERNANDEZ, MARCELO; ANJOS, ROBERTO M.; CABRAL, PABLO. Development of sup(177)Lu-DOTA-dendrimer and determination of its effect on metal and ion levels in tumor tissue. Cancer Biotherapy and Radiopharmaceuticals, v. 30, n. 10, p. 405-409, 2015. DOI: 10.1089/cbr.2014.1675

    Palavras-Chave: lutetium 177; neutron activation analysis; dendrimers; trace amounts; multi-element analysis; neoplasms; in vivo; stability; high-performance liquid chromatography; mice

  • IPEN-DOC 12287

    SUZUKI, MIRIAM F. ; SILVA, MARCIA A. da; CALDEIRA FILHO, JOSE de S. ; COLTURATO, MARIA T. ; ARAUJO, ELAINE B. de ; BARTOLINI, PAOLO ; OKAZAKI, KAYO . Genotoxic evaluation of [DOTA, Tyrsup(3)]octreotate labelled with sup(131)I and sup(177)Lu in human peripheral lymphocytes in vitro by micronucleus assay. International Journal of Low Radiation, v. 4, n. 2, p. 161-168, 2007.

    Palavras-Chave: dose-response relationships; experimental data; genetic radiation effects; in vitro; iodine 131; labelled compounds; lutetium 177; lymphocytes; neoplasms; somatostatin; toxicity

  • IPEN-DOC 28654

    BOAS, CRISTIAN A.W.V. ; SILVA, JEFFERSON de J. ; DIAS, LUIS A.P. ; FREIRE, MARIA R.B. ; BALIEIRO, LUIZA M. ; SANTOS, CAROLINA S.F. dos ; VIVALDINI, BIANCA F. ; BENEDETTO, RAQUEL ; VIEIRA, DANIEL P. ; PASSOS, PRISCILA de Q.S. ; MARUMO, MARIA H. ; TEIXEIRA, LUIS F.S. ; ARAUJO, ELAINE B. de . In vitro and in vivo response of PSMA-617 radiolabeled with CA and NCA lutetium-177. Applied Radiation and Isotopes, v. 180, p. 1-7, 2022. DOI: 10.1016/j.apradiso.2021.110064

    Abstract: The PSMA-targeted radionuclide therapy has been explored since 2015 with radioisotope lutetium-177, whose β− emission range is adequate for micrometastases treatment. This radioisotope is obtained by two different production routes that directly affect the specific activity of lutetium-177 (non-carrier added and carrier added) and, consequently, the specific activity of radiopharmaceuticals, like 177Lu-PSMA-617. The influence of the specific activity of lutetium-177 on the properties of the radiopharmaceutical PSMA-617 was evaluated through pre-clinical studies. The in vitro study pointed to a lower constant of dissociation with non-carrier added lutetium-177 due to the difference in the specific activity. However, competition and internalization assays resulted in similar results for both lutetium-177. Based on these pre-clinical experiments, the total in vitro tumor cell binding and tumor uptake in vivo were similar, with no influence of the specific activity of the 177Lu-PSMA-617. Regardless the specific activity did not directly affect tumor uptake, the tumor/non-target organs ratios were higher for the radiopharmaceutical labeled with carrier added lutetium-177, which had the lowest specific activity.

    Palavras-Chave: prostate; membranes; antigens; lutetium 177; activity levels; in vivo; in vitro; in vitro; radiopharmaceuticals; neoplasm

  • IPEN-DOC 16663

    COUTO, R.M. ; BARBOZA, M.F. de ; SOUZA, A.A. de ; MURAMOTO, E. ; MENGATTI, J. ; ARAUJO, E.B. de . In vivo comparative study of hydroxyapatite labeled with different radioisotopes: evaluation of the scintigraphic images. Cellular and Molecular Biology, v. 56, n. 2, p. 6-11, 2010.

    Palavras-Chave: apatites; radiopharmaceuticals; labelled compounds; yttrium 90; lutetium 177; samarium 153; rheumatic diseases

  • IPEN-DOC 11424

    CALDEIRA FILHO, JOSE S. ; MURAMOTO, EMIKO ; SILVA, CONSTANCIA P.G. ; ARAUJO, ELAINE B. . Labeling of DOTA-Tyrsup(3)-octreotate with sup(177)Lu - stabillity and biodistribution study. ALASBIMN Journal, v. 7, n. 28, p. 9-14, 2005.

    Palavras-Chave: labelling; tracer techniques; lutetium 177; radiopharmaceuticals; peptides; kidneys; in vivo; stability

  • IPEN-DOC 17127

    PUJATTI, P.B.; SANTOS, J.S.; COUTO, R.M.; MELERO, L.T.U.H.; SUZUKI, M.F. ; SOARES, C.R.J. ; GRALLERT, S.R.M.; MENGATTI, J. ; ARAUJO, E.B. de . Novel series of sup(177)Lu-labeled bombesin derivatives with amino acidic for selective targeting of human PC-3 prostate tumor cells. Quarterly Journal of Nuclear Medicine and Molecular Imaging, v. 55, n. 3, p. 310-323, 2011.

    Palavras-Chave: prostate; neoplasms; labelling; lutetium 177; receptors; amino acids; mice; radionuclide kinetics; chromatography

  • IPEN-DOC 27882

    ZAHN, G.S. ; GENEZINI, F.A. ; SILVA, P.S.C. ; NORY, R.M. ; MOREIRA, E.G. ; SANTIAGO, P.S. . On the feasibility of producing Lu-177 in the IEA-R1 reactor via the direct route. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-11, 2021. DOI: 10.15392/bjrs.v9i1A.1411

    Abstract: Over the last years the 177Lu radioisotope has attracted great interest for the use in therapeutic and diagnostic procedures simultaneously, being what is now called a theranostic radioisotope, with outstanding results in prostate and neuroendocrine cancer. There are mainly two ways of producing this radioisotope, by direct neutron capture in a 176Lu target (the “direct route") or by irradiating a 176Yb sample, producing 177Yb that will then decay to 177Lu (also referred as the “indirect route”). In this work, the technical feasibility of producing 177Lu in the IEA-R1 nuclear research reactor via the direct route was assessed, and the specific activity that could be obtained was estimated both experimentally and theoretically.

    Palavras-Chave: capture; cross sections; feasibility studies; iear-1 reactor; isotope production; lutetium 176 target; lutetium 177; neutron reactions

  • IPEN-DOC 22542

    ARAUJO, E.B. de ; PUJATTI, P.B. ; MENGATTI, J. . Radiolabeling of substance p with lutetium-177 and biodistribution study in rat pancreatic tumor xenografted nude mice. Cellular and Molecular Biology, v. 56, n. 2, p. 12-17, 2010.

    Palavras-Chave: labelling; lutetium 177; tissue distribution; animals; neoplasms; mice; pancreas; endocrine diseases; evaluation

  • IPEN-DOC 18884

    ZIMMERMAN, B.E.; ALTZITZOGLOU, T.; ANTOHE, A.; ARINC, A.; BAKHSHANDEIAR, E.; BERGERON, D.E.; BIGNELL, L.; BOBIN, C.; CAPOGNI, M.; CESSNA, J.T.; COZZELLA, M.L.; DA SILVA, C.J.; DE FELICE, P.; DIAS, M.S. ; DZIEL, T.; FAZIO, A.; FITZGERALD, R.; IWAHARA, A.; JAUBERT, F.; JOHANSSON, L.; KEIGHTLEY, J.; KOSKINAS, M.F. ; KOSSERT, K.; LUBBE, J.; LUCA, A.; MO, L.; NAEHLE, O.; OTT, O.; PAEPEN, J.; POMME, S.; SAHAGIA, M.; SIMPSON, B.R.S.; SILVA, F.F.V. ; AMMEL, R. VAN; STADEN, M.J. VAN; WYNGAARDT, W.M. VAN; YAMAZAKI, I.M. . Results of an international comparison for the activity measurement of sup(177)Lu. Applied Radiation and Isotopes, v. 70, n. 7, p. 1825-1830, 2012.

    Palavras-Chave: calibration standards; comparative evaluations; interlaboratory comparisons; lutetium 177; solutions

  • IPEN-DOC 27848

    VILLAS BOAS, C.A.W. ; DIAS, L.A.P. ; MATSUDA, M.M.N. ; ARAUJO, E.B. . Stability in production and transport of 177Lu labeled PSMA. Brazilian Journal of Radiation Sciences, v. 9, n. 1, p. 1-12, 2021. DOI: 10.15392/bjrs.v9i1.1619

    Abstract: In Brazil, prostate cancer is a common disease among men. The radionuclide therapy with PSMA analogs, labeled with beta and alpha emitters, has brought new perspectives for patients with multi metastatic resistant prostate cancer. The commercialization of radiopharmaceutical becomes a challenge to transport and ensure the quality of the product, especially in terms of radiochemical stability of therapeutic radiopharmaceuticals. The effect of radiolysis on therapeutic doses of radiopharmaceuticals can be avoided or mitigated by diluting the final dose and reducing storage and transportation temperature. This study evaluated the effect of radiolysis on the different radioactive concentration in the industrial batches of 177Lu-PSMA-617 and in the fractionated doses, considering long time transportation. The radiopharmaceutical 177Lu-PSMA-617 was produced in batches reaching 37 GBq, and stability studies were performed in controlled conditions. The results showed that a combination of factors, including reaction buffer, the radioactive concentration of final product, and freezing storage contributed to the stability of the radiopharmaceutical for 48 hours, enabling transport of 177Lu-PSMA-617 to distant regions of the country.

    Palavras-Chave: neoplasms; prostate; lutetium 177; antigens; radiopharmaceuticals; radiolysis; stability

  • IPEN-DOC 16122

    DIAS, MAURO S. ; SILVA, FABRICIO F.V.; KOSKINAS, MARINA F. . Standardization and measurement of gamma-ray probability per decay of sup(177)Lu. Applied Radiation and Isotopes, v. 68, n. 7-8, p. 1349-1353, 2010.

    Palavras-Chave: aluminium; coincidence methods; comparative evaluations; computerized simulation; efficiency; emission; extrapolation; gamma radiation; half-life; high-purity ge detectors; lutetium 177; monte carlo method; nai detectors; nuclear decay; probability; proportional counters; radiation sources; standardization

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.