Navegação Periódicos - Artigos por assunto "nai detectors"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 07569

    ATTIE, M.R.P.; KOSKINAS, M.F. ; DIAS, M.S. ; FONSECA, K.A. . Absolute disintegration rate measurements of Ga-67. Applied Radiation and Isotopes, v. 49, n. 9/11, p. 1175-1177, 1998.

    Palavras-Chave: gallium 67; standardization; decay; coincidence methods; proportional counters; nai detectors; high-purity ge detectors; gamma spectroscopy

  • IPEN-DOC 08422

    VENTURINI, L. ; CAMPOS, V.P. ; BERTI, E.A.R. . An approach for the efficiency calibration of whole body counters. Health Physics, v. 81, n. 5, p. 580-584, 2001.

    Palavras-Chave: whole-body counting; whole-body counters; calibration; experimental data; monte carlo method; computerized simulation; phantoms; nai detectors

  • IPEN-DOC 08248

    FONSECA, K.A. ; KOSKINAS, M.F. ; DIAS, M.S. . Disintegration rate measurement of a sup(192)Ir solution. Applied Radiation and Isotopes, v. 54, n. 1, p. 141-145, 2001.

    Palavras-Chave: iridium 192; electron capture decay; standardization; beta decay; coincidence methods; particle decay; proportional counters; nuclear medicine; calibration standards; radionuclide kinetics; nai detectors

  • IPEN-DOC 20063

    DIAS, M.S. ; BRANCACCIO, F. ; TOLEDO, F. ; KOSKINAS, M.F. . Disintegration rate, gamma-ray emission probabilities and metastable half-life measurements of sup(67)Ga. Applied Radiation and Isotopes, v. 87, p. 126-131, 2014.

    Palavras-Chave: gallium 67; standardization; decay; coincidence methods; proportional counters; nai detectors; high-purity ge detectors; gamma spectroscopy; half-life; monte carlo method

  • IPEN-DOC 25852

    MESQUITA, C.H. ; VELO, A.F. ; CALVO, W.P. ; CARVALHO, D.V. ; HAMADA, M.M. . Emission and transmission tomography system applied to analyze industrial process inside chemical reactors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v. 954, p. 1-3, 2020. DOI: 10.1016/j.nima.2019.01.073

    Abstract: The tomography techniques are widely used in many industries, such as: chemical, food, pharmaceutical and oil sectors. In the industries the tomography is used to diagnose the state of the machines of production and also in the control of quality of the produced objects. A portable tomography system known as instant-non-scanning type, a similar version of the fourth generation CT, was developed in this work. It is capable to obtain measurements in real time conditions without interrupting the operation of the industrial production and it is useful in the quality control of the means of production and the objects produced. This paper describes an innovative hybrid industrial tomographic system, i.e., simultaneous data from the emission of an internal radioactive source introduced inside to the object (67Ga citrate) and tomographic transmission using five sources of 137Cs positioned externally to the object which are distributed at the vertices of a pentagon. The tomographic system described here is useful for studying dynamic chemical phenomena, associated or not with multiphase systems commonly found in chemical reactors and distillation columns.

    Palavras-Chave: cesium 137; diagnostic techniques; tomography; computerized tomography; image processing; nai detectors; citrates; gallium 67; external irradiation; trace amounts

  • IPEN-DOC 25777

    MESQUITA, C.H. de ; CALVO, W.A.P. ; AOKI, P.E. ; SILVA, V.C. da ; HARAGUCHI, M.I. ; VELO, A.F. ; ALVAREZ, A.G. ; HAMADA, M.M. . Gallium-67 citrate used as a tracer of acetone production routes. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-9, 2019. DOI: 10.15392/bjrs.v7i2A.562

    Abstract: In this work the pathway of the chemical product and the kinetics parameters were evaluated in a laboratory plant settled, using 0.4 GBq (10 mL) of 67Ga citrate as radiotracer and 18 NaI(Tl) radiation detectors. The AnaComp program was used to estimate the kinetic para ameters of the acetone production. The yield of the acetone production was estimated by the percentage ratio between the areas under the curve (AUC) of the curve profiles of the final product compartment divided by the concentration found inside the chemical reactor whose result was 87% yield during the first 30 minutes of reaction.

    Palavras-Chave: gallium 67; citrates; multi-channel analyzers; acetone; nai detectors; tracer techniques; calibration; radioactivity; kinetics

  • IPEN-DOC 03108

    SAXENA, R.N. ; JAHNEL, L.C.; ZAWISLAK, F.C.. Gamma-gamma directional correlations for transitions in sup(84) Kr. Physical Review, C, v. 21, n. 4, p. 1531-1537, 1980.

    Palavras-Chave: gamma radiation; angular correlation; krypton 84; decay; bromine 84; li-drifted ge detectors; nai detectors; gamma cascades

  • IPEN-DOC 25780

    VELO, A.F. ; ALVAREZ, A.G. ; HAMADA, M.M. ; MESQUITA, C.H. . Image quality analysis of an industrial instant non-scanning tomography system with different collimators. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-14, 2019. DOI: 10.15392/bjrs.v7i2A.561

    Abstract: An instant non-scanning tomography system is being developed at the IPEN. This type of tomography system, due to its configurations, provides a low spatial resolution; however, it presents a high temporal resolution as an advantage. In this sense, it has high applicability in industrial processes involving dynamic multiphase processes, like distillation columns. Thereby, to obtain the best conditions of image acquisition, this tomography system comprising different collimators was simulated with Monte Carlo using the MCNP4C.The image quality was evaluated with Matlab® 2013b analyzing the contrast to noise ratio (CNR), root mean square ratio (RMSE), signal to noise ratio (SNR) and the spatial resolution by the Modulation Transfer Function (MTF(f)), to identify which collimator fits better to the tomography in development. It was simulated three situations; (i) with no collimator; (ii) ø 25x 50 mm2 cylindrical collimator with a septum of ø5.0 x 50 mm2; (iii) ø25 x 50 mm2 cylindrical collimator with a slit septum of 24 x 5.0 x 50 mm3. RMSE values for no collimator presented better results. CNR showed that no collimator and slit collimator reaches the same CNR values, but no collimator decreases more than the slit collimator as the number of iteration rises. The hole collimator reaches a higher CNR value, however decreases more than the others. The spatial resolution with no collimator and slit collimator were around 31.9 mm, and for the hole collimator was around 20 mm.

    Palavras-Chave: collimators; tomography; computerized tomography; computerized simulation; monte carlo method; quality assurance; quality management; image processing; nai detectors; signal-to-noise ratio; radiation detectors; radiation detectors; industrial plants; brazilian cnen

  • IPEN-DOC 07581

    FONSECA, K.A. ; KOSKINAS, M.F. ; DIAS, M.S. . Measurement of the gamma-ray probability per decay of I-126. Applied Radiation and Isotopes, v. 49, n. 9/11, p. 1373-1376, 1998.

    Palavras-Chave: iodine 126; particle decay; coincidence methods; calibration standards; radionuclide kinetics; nuclear medicine; nai detectors; high-purity ge detectors

  • IPEN-DOC 16120

    DIAS, MAURO S. ; TONGU, MARGARETH L.O.; TAKEDA, MAURO N.; KOSKINAS, MARINA F. . Monte Carlo simulation to positron emitter standardized by means of 4'pi''beta'-'gamma' coincidence system - Application to sup(22)Na. Applied Radiation and Isotopes, v. 68, n. 7-8, p. 1362-1366, 2010.

    Palavras-Chave: annihilation; calibration; computerized simulation; emission; extrapolation; monte carlo method; nai detectors; nuclear decay; photons; positrons; probability; proportional counters; response functions; sodium 22; standardization

  • IPEN-DOC 27904

    SANTOS, R.S. ; CAVALLARO, F.A.; BERNARDES, T.L.S. ; AMADEU, R.A. ; GARCIA, R.H.L. ; VELO, A.F. ; MESQUITA, C.H. ; HAMADA, M.M. . Performance of the X-ray powder diffraction (XRD), X-ray fluorescence (XRF) and the industrial computed tomography used for characterization of the vesicular volcanic rock. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-13, 2021. DOI: 10.15392/bjrs.v9i1A.1523

    Abstract: Volcanic rock is a designation in geology given to extrusive igneous rocks. One type of igneous rock of interest, in economic terms, is vesicular, since, besides the knowledge of the morphology (positioning, size, direction, and interconnectivity of the vesicles) of these structures within the spill, there is also an economic interest regarding the possibility of this rock as a reservoir of fluids (water and hydrocarbons). In this work, samples of vesicular volcanic rock from the Paraná Basin were studied for their characterization, aiming to contribute to the knowledge of this rock proprieties as a reservoir of fluids. The elements present inside the rocks were identified and quantified by X ray fluorescence and X ray diffraction. The dimensions of the vesicles and the interconnection between them could be clearly observed in the reconstructed images of the rocks measured by the third generation Gamma ray industrial tomography technique

    Palavras-Chave: chemical composition; computerized tomography; gamma radiation; iridium 192; nai detectors; petrography; powders; reservoir fluids; volcanic rocks; x-ray diffraction; x-ray fluorescence analysis

  • IPEN-DOC 27895

    BERNARDES, T.L.S. ; AMADEU, R.A. ; SANTOS, R.S. ; GARCIA, R.H.L. ; VELO, A.F. ; CAVALLARO, F.A.; MESQUITA, C.H. ; HAMADA, M.M. . Petrological study of the Iraty Formation Shale Rocks from Paraná Basin, Limeira, São Paulo. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-17, 2021. DOI: 10.15392/bjrs.v9i1A.1467

    Abstract: Shales are fine-grained rocks formed by clays and silt-sized particles in thin, relatively impermeable layers. They are originated from rocks that suffered weathering and erosion and their composition is quite variable. When oil production declines, interest arises to improve the understanding of the physicochemical properties of unconventional rocks, like shale. For the characterization of the shale samples of the Iraty Formation, the gamma-ray computed industrial tomography technique has been proposed to be used as an alternative to obtaining information about each element present in the mineral, the pore distribution, through the shale morphology. The tomographic results were compared with those obtained by conventional methodologies used in the petrological analysis, such as scanning electron microscopy (SEM), x-ray fluorescence, and x-ray diffraction.

    Palavras-Chave: comparative evaluations; computerized tomography; gamma radiation; industrial radiography; morphology; nai detectors; petrology; reservoir rock; shales

  • IPEN-DOC 16121

    KOSKINAS, MARINA F. ; MOREIRA, DENISE S.; YAMAZAKI, IONE M. ; TOLEDO, FABIO de ; BRANCACCIO, FRANCO ; DIAS, MAURO S. . Primary standardization of sup(57)Co. Applied Radiation and Isotopes, v. 68, n. 7-8, p. 1344-1348, 2010.

    Palavras-Chave: absorption; calibration; cobalt 57; coincidence methods; computerized simulation; extrapolation; gamma detection; gamma radiation; ge semiconductor detectors; kev range 100-1000; monte carlo method; nai detectors; standardization; x-ray spectrometers

  • IPEN-DOC 16122

    DIAS, MAURO S. ; SILVA, FABRICIO F.V.; KOSKINAS, MARINA F. . Standardization and measurement of gamma-ray probability per decay of sup(177)Lu. Applied Radiation and Isotopes, v. 68, n. 7-8, p. 1349-1353, 2010.

    Palavras-Chave: aluminium; coincidence methods; comparative evaluations; computerized simulation; efficiency; emission; extrapolation; gamma radiation; half-life; high-purity ge detectors; lutetium 177; monte carlo method; nai detectors; nuclear decay; probability; proportional counters; radiation sources; standardization

  • IPEN-DOC 10468

    FERREIRA, C.R.P.P.; KOSKINAS, M.F. ; DIAS, M.S. . Standardization of Ca-45 radioactive solution by tracing method. Brazilian Journal of Physics, v. 34, n. 3A, p. 939-941, 2004.

    Palavras-Chave: calcium 45; standardization; decay; cobalt 60; beta decay; gamma decay; coincidence methods; proportional counters; nai detectors

  • IPEN-DOC 20984

    CARVALHO, GILBERTO ; ANDRADE e SILVA, LEONARDO G. de . Study of brazilian woods using gamma-ray sources. Journal of Physical Science and Application, v. 4, n. 5, p. 304-309, 2014.

    Palavras-Chave: brazil; wood; physical properties; density; gamma radiation; americium 241; barium 133; cesium 137; nai detectors

  • IPEN-DOC 25708

    VELO, A.F. ; ALVAREZ, A.G. ; CARVALHO, D.V..S. ; FERNANDEZ, V. ; SOMESSARI, S. ; SPRENGER, F.F. ; HAMADA, M.M. ; MESQUITA, C.H. . A third generation tomography system with fifteen detectors simulated by Monte Carlo method. Brazilian Journal of Radiation Sciences, v. 7, n. 2A, p. 1-13, 2019. DOI: 10.15392/bjrs.v7i2A.708

    Abstract: This paper describes the Monte Carlo simulation, using MCNP4C, of a multichannel third generation tomography system containing a two radioactive sources 192I (316.5 – 468 KeV) and 137Cs (662 KeV), and a set of fifteen NaI(Tl) detectors, with dimensions of 1 inch diameter and 2 inches thick, in fan beam geometry, positioned diametrically opposite. Each detector moves 10 steps of 0,24o, totalizing 150 virtual detectors per projection, and then the system rotate 2 degrees. The Monte Carlo simulation was performed to evaluate the viability of this configuration. For this, a multiphase phantom containing polymethyl methacralate (PMMA ((  1.19 g/cm3)), iron (  7.874 g/cm3), aluminum (  2.6989 g/cm3) and air (  1.20479E-03 g/cm3) was simulated. The simulated number of histories was 1.1E+09 per projection and the tally used were the F8, which gives the pulse height of each detector. The data obtained by the simulation was used to reconstruct the simulated phantom using the statistical iterative Maximum Likelihood Estimation Method Technique (ML-EM) algorithm. Each detector provides a gamma spectrum of the sources, and a pulse height analyzer (PHA) of 10% on the 316.5 KeV and 662 KeV photopeaks was performed. This technique provides two reconstructed images of the simulated phantom. The reconstructed images provided high spatial resolution, and it is supposed that the temporal resolution (spending time for one complete revolution) is about 2.5 hours.

    Palavras-Chave: calculation methods; monte carlo method; nai detectors; spatial resolution; computerized simulation; cesium 137; computerized tomography; phantoms; iridium 192; configuration; tomography

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.