Navegação Periódicos - Artigos por assunto "optical equipment"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 26864

    PARDO DIAZ, C.A.; SHIMOKAWA, C.A.K.; SAMPAIO, C.S.; FREITAS, A.Z. ; TURBINO, M.L.. Characterization and comparative analysis of voids in class II composite resin restorations by optical coherence tomography. Operative Dentistry, v. 45, n. 1, p. 71-79, 2020. DOI: 10.2341/18-290-L

    Abstract: Purpose: This study aimed to characterize and analyze the number of voids and the percentage of void volume within and between the layers of class II composite restorations made using the bulk fill technique or the incremental technique by optical coherence tomography (OCT). Methods and Materials: Class II cavities (43432 mm) were prepared in 48 human third molars (n=24 restorations per group, two class II cavities per tooth). Teeth were divided into four groups and restored as follows: group 1 (FOB), bulk filled in a single increment using Filtek One Bulk Fill (3M Oral Care); group 2 (FXT), incrementally filled using four oblique layers of Filtek Z350 XT (3M Oral Care); group 3 (FBF+FXT), bulk filled in a single increment using Filtek Bulk Fill Flowable Restorative (3M Oral Care) covered with two oblique layers of Filtek Z350 XT (3M Oral Care), and group 4 (FF+FXT), incrementally filled using Filtek Z350 XT Flow (3M Oral Care) covered with two oblique layers of Filtek Z350 XT (3M Oral Care). After the restorative procedure, specimens were immersed into distilled water and stored in a hot-air oven at 378C. Forty-eight hours later, thermal cycling was conducted (5000 cycles, 58C to 558C). Afterward, OCT was used to detect the existence of voids and to calculate the number of voids and percentage of voids volume within each restoration. Data were submitted to chi-square and Kruskal- Wallis tests (a=0.05). Comparisons were made using the Dunn method. Results: Voids were detected in all groups, ranging from 0.000002 (FBF+FXT and FF+FXT) to 0.32 mm3 (FBF+FXT). FF + FXT presented voids in all of the restorations and had a significantly higher number of voids per restoration when compared to the other groups (p,0.05), but restorations with the presence of voids were significantly higher only when compared to FXT (p,0.05). FBF + FXT presented a significantly higher percentage of voids volume than that of FXT (p,0.05). When comparing restorations made using high-viscosity resin-based composites (FOB and FXT), no significant differences regarding number of voids or percentage of voids volume were detected (p 0.05). Conclusions: The use of flowable resin-based composites can result in an increased number of voids and percentage of voids volume in restorations, and this appears to be more related to voids present inside the syringe of the material than to the use of incremental or bulk fill restorative techniques.

    Palavras-Chave: dentistry; resins; biological recovery; tomography; optical equipment; images; composite materials; voids; layers

  • IPEN-DOC 26419

    PRETTO, LUCAS R. de ; MOULT, ERIC M.; ALIBHAI, A.Y.; CARRASCO-ZEVALLOS, OSCAR M.; CHEN, SIYU; LEE, BYUNGKUN; WITKIN, ANDRE J.; BAUMAL, CAROLINE R.; REICHEL, ELIAS; FREITAS, ANDERSON Z. de ; DUKER, JAY S.; WAHEED, NADIA K.; FUJIMOTO, JAMES G.. Controlling for artifacts in widefield optical coherence tomography angiography measurements of non-perfusion area. Scientific Reports, v. 9, p. 1-15, 2019. DOI: 10.1038/s41598-019-43958-1

    Abstract: The recent clinical adoption of optical coherence tomography (OCT) angiography (OCTA) has enabled non-invasive, volumetric visualization of ocular vasculature at micron-scale resolutions. Initially limited to 3 mm × 3 mm and 6 mm × 6 mm fields-of-view (FOV), commercial OCTA systems now offer 12 mm × 12 mm, or larger, imaging fields. While larger FOVs promise a more complete visualization of retinal disease, they also introduce new challenges to the accurate and reliable interpretation of OCTA data. In particular, because of vignetting, wide-field imaging increases occurrence of low-OCT-signal artifacts, which leads to thresholding and/or segmentation artifacts, complicating OCTA analysis. This study presents theoretical and case-based descriptions of the causes and effects of low-OCTsignal artifacts. Through these descriptions, we demonstrate that OCTA data interpretation can be ambiguous if performed without consulting corresponding OCT data. Furthermore, using wide-field non-perfusion analysis in diabetic retinopathy as a model widefield OCTA usage-case, we show how qualitative and quantitative analysis can be confounded by low-OCT-signal artifacts. Based on these results, we suggest methods and best-practices for preventing and managing low-OCT-signal artifacts, thereby reducing errors in OCTA quantitative analysis of non-perfusion and improving reproducibility. These methods promise to be especially important for longitudinal studies detecting progression and response to therapy.

    Palavras-Chave: ophthalmology; retina; biomedical radiography; tomography; vascular diseases; optical equipment; coherent radiation; images; blood vessels; beam scanners

  • IPEN-DOC 24863

    BERECZKI, ALLAN ; LOPEZ, MARCIO A.P.A. ; WETTER, NIKLAUS U. . Dynamically stable Nd:YAG resonators with beam quality beyond the birefringence limit and pumping of a singly resonant optical parametric oscillator. Optics Letters, v. 43, n. 4, p. 695-698, 2018. DOI: 10.1364/OL.43.000695

    Abstract: A simple, reliable, linearly polarized laser source with very high beam quality is demonstrated using standard diode-side-pumped Nd:YAG modules. The laser produced 30 W of output power with beam quality factor 𝑀2<1.15 over the entire range of input powers and beam quality of 1.02 at the laser operation point. This is, to our knowledge, the highest beam quality for a dynamically stable high-power laser that uses an optically isotropic crystal. The laser was used as a pump source for an optical parametric oscillator based on a periodically poled lithium niobate, producing wavelength in the 1.5–3.8 μm range.

    Palavras-Chave: lasers; resonators; diode-pumped solid state lasers; neodymium lasers; beams; quality factor; lithium; niobates; optical systems; parametric oscillators; optical equipment; laser pumping

  • IPEN-DOC 29619

    BORDON, CAMILA D. da S.; DIPOLD, JESSICA ; WETTER, NIKLAUS U. ; ROSSI, WAGNER de ; FREITAS, ANDERSON Z. ; KASSAB, LUCIANA R.P.. Effect of silver nanoparticles on the optical properties of double line waveguides written by fs laser in Nd3+-doped GeO2-PbO glasses. Nanomaterials, v. 13, n. 4, p. 1-13, 2023. DOI: 10.3390/nano13040743

    Abstract: Nd3+-doped GeO2-PbO glass with silver (Ag) nanoparticles (NPs) are produced with double line waveguides through fs laser processing for photonic applications. A Ti:sapphire fs laser at 800 nm was used to write the waveguides directly into the glass 0.7 mm beneath the surface. This platform is based on pairs of parallel lines with spacing of 10 µm, each pair being formed by two identical written lines but in two different configurations of 4 or 8 separately processed lines, which are coincident. The results of optical microscopy, absorbance measurements, refractive index change, beam quality factor (at 632 and 1064 nm), photoluminescence, propagation losses, and relative gain at 1064 nm are presented. The structural changes in the glass due to the presence of Ag NPs were investigated by Raman spectroscopy. At 632 and 1064 nm, x,y-symmetrical guiding was observed, and for both kinds of overlapping pulses, a refractive index alteration of 10−3 was found in both directions. Photoluminescence growth of ~47% at 1064 nm was observed due to the plasmonic effect of Ag NPs. In dual waveguides containing Ag NPs, the relative gain obtained increased by 40% and 30% for four and eight overlapping lines, respectively, at 600 mW of 808 nm pump power, when compared to waveguides without those metallic NPs. We highlight the resultant positive internal gains of 5.11 and 7.12 dB/cm that showed a growth of ~40% and ~30%, respectively, with respect to the samples without Ag NPs. The increase in photoluminescence and relative gain were related to the local field growth produced by Ag NPs. The present results show that the addition of Ag NPs impacts positively on the optical performance at 1064 nm of double line waveguides processed by fs laser writing in Nd3+-doped GeO2-PbO glass, opening news perspectives for photonics.

    Palavras-Chave: lasers; pulses; germanates; waveguides; optical equipment; silver; nanoparticles

  • IPEN-DOC 27773

    NEGRINI NETO, O. ; SARKIS, J.E.S. ; SIQUEIRA, A.N. ; RIBEIRO, L.A.S. ; FREITAS, A.Z. . A new method for measuring pen pressure in forensic handwriting analysis: a proof of concept study. Analyst, v. 146, n. 6, p. 1973-1980, 2021. DOI: 10.1039/d0an01787f

    Abstract: This work describes a new method for the analysis of handwritten documents through a system composed of a pre-selector optical analyser equipped with light sources of different wavelengths coupled with bandpass filters combined with an optical coherence tomography (OCT) instrument. The optical analyser identifies regions with different pen pressures on the paper using specific wavelengths from ultraviolet (UV) to infrared (IR) and bandpass filters. Then the selected regions are analysed with a coherence tomography analyser to measure the depth of grooves and capture three-dimensional images. With this methodology, it is possible to identify similarities, or differences, between the pieces of evidence under investigation, increasing the possibility of correct attribution concerning the authorship of the signature and we also showed that this feature is independent of the paper substrate. In this work, a new strategy will be presented to categorize and quantify pen pressure in order to aid a better response for a forensic examiner. Thereby, from the observed areas that display higher pressures (more significant grooves), it is possible to determine the authorship of the signature.

    Palavras-Chave: light transmission; optical equipment; light sources; crime detection; document types; images; measuring methods; systems analysis

  • IPEN-DOC 21297

    GOULART, VIVIANE P. ; SANTOS, MOISES O. dos; LATRIVE, ANNE ; FREITAS, ANDERSON Z. ; CORREA, LUCIANA; ZEZELL, DENISE M. . Noninvasive monitoring of photodynamic therapy on skin neoplastic lesions using the optical attenuation coefficient measured by optical coherence tomography. Journal of Biomedical Optics, v. 20, n. 5, p. 051007-1 - 051007-7, 2015.

    Palavras-Chave: monitoring; therapy; skin; attenuation; tomography; images; mice; neoplasms; histological techniques; optical equipment

  • IPEN-DOC 26694

    QUITERO, MAYRA F.Z.; SIRIANI, LUCIANA K.; AZEVEDO, CYNTHIA S. de; FREITAS, ANDERSON Z. de ; SCARAMUCCI, TAIS; SIMIONATO, MARIA R.L.; MATOS, ADRIANA B.. Optical coherence tomography and polarized light microscopy for the evaluation of artificial caries: a preliminary study. General Dentistry, v. 67, n. 1, p. e1-e6, 2019.

    Abstract: This study was designed to investigate whether there is a correlation between the findings of optical coherence tomography (OCT) and polarized light microscopy (PLM) when these techniques are used to evaluate standard enamel white-spot lesions developed by distinct cariogenic challenges. Bovine enamel fragments (N = 168) were randomly allocated into 6 experimental groups according to the microbiologic model (Streptococcus mutans UA159, Streptococcus sobrinus ATCC 33478, or mixed S mutans and S sobrinus) and carbohydrate sources (1% sucrose or combined 1% sucrose and 1% starch). Specimens were examined by OCT and PLM every day within a period of 7 days. Five measurements of demineralization depth were recorded for each specimen, and means were calculated. Data were analyzed with analysis of variance and Tukey tests (α = 0.05), and a correlation test was performed. All cariogenic challenges created sub-superficial lesions. In both the OCT and PLM analyses, the demineralization depth reached its peak between days 6 and 7 of the cariogenic challenge, except for the group challenged with S sobrinus supplemented with combined sucrose and starch; for that group, demineralization peaked on day 5 in the OCT analysis. There was a significant correlation between OCT and PLM (P = 0.00; r = 0.842). This preliminary study suggests that OCT is a reliable, nondestructive method to measure the demineralization depth of enamel whitespot lesions, which can be useful for the laboratory and has potential for clinical studies. Using the 1% sucrose and S mutans model for 6 days is a simple and effective method to induce enamel caries–like lesions without compromising the depth and morphologic features of the obtained lesions.

    Palavras-Chave: tomography; optical equipment; coherent radiation; optical tomography; polarized beams; dentistry; caries; bacteria; enamels; microbial processes; streptococcus; statistical data

  • IPEN-DOC 26682

    ISHIBAZAWA, AKIHIRO; PRETTO, LUCAS R. de ; ALIBHAI, A. YASIN; MOULT, ERIC M.; ARYA, MALVIKA; SOROUR, OSAMA; MEHTA, NIHAAL; BAUMAL, CAROLINE R.; WITKIN, ANDRE J.; YOSHIDA, AKITOSHI; DUKER, JAY S.; FUJIMOTO, JAMES G.; WAHEED, NADIA K.. Retinal nonperfusion relationship to arteries or veins observed on widefield optical coherence tomography angiography in diabetic retinopathy. Investigative Ophthalmology & Visual Science, v. 60, n. 13, p. 4310-4318, 2019. DOI: 10.1167/iovs.19-26653

    Abstract: PURPOSE. To evaluate whether retinal capillary nonperfusion is found predominantly adjacent to arteries or veins in eyes with diabetic retinopathy (DR). METHODS. Sixty-three eyes from 44 patients with proliferative DR (PDR) or non-PDR (NPDR) were included. Images (12 3 12-mm) foveal-centered optical coherence tomography (OCT) angiography (OCTA) images were taken using the Zeiss Plex Elite 9000. In 37 eyes, widefield montages with five fixation points were also obtained. A semiautomatic algorithm that detects nonperfusion in full-retina OCT slabs was developed, and the percentages of capillary nonperfusion within the total image area were calculated. Retinal arteries and veins were manually traced. Based on the shortest distance, nonperfusion pixels were labeled as either arterial-side or venous-side. Arterial-adjacent and venous-adjacent nonperfusion and the A/V ratio (arterial-adjacent nonperfusion divided by venous-adjacent nonperfusion) were quantified. RESULTS. Twenty-two eyes with moderate NPDR, 16 eyes with severe NPDR, and 25 eyes with PDR were scanned. Total nonperfusion area in PDR (median: 8.93%) was greater than in moderate NPDR (3.49%, P < 0.01). Arterial-adjacent nonperfusion was greater than venousadjacent nonperfusion for all stages of DR (P < 0.001). The median A/V ratios were 1.93 in moderate NPDR, 1.84 in severe NPDR, and 1.78 in PDR. The A/V ratio was negatively correlated with the total nonperfusion area (r ¼ 0.600, P < 0.0001). The results from the widefield montages showed similar patterns. CONCLUSIONS. OCTA images with arteries and veins traced allowed us to estimate the nonperfusion distribution. In DR, smaller nonperfusion tends to be arterial-adjacent, while larger nonperfusion tends toward veins.

    Palavras-Chave: tomography; optical modes; optical equipment; diabetes mellitus; blood vessels; ischemia; retina; veins

  • IPEN-DOC 11050

    PRETO, A.O.; FREITAS, D.M.; REIS JUNIOR, N.D.; DUARTE, V.; KASSAB, L.R.P.; PRISON, J.M.; MARTINELLI, J.R. . Sistema de agitacao mecanica para reducao de estrias em matrizes vitreas. Boletim Técnico da Faculdade de Tecnologia de São Paulo, v. 16, p. 36-39, 2004.

    Palavras-Chave: glass; matrices; optical equipment; furnaces; mixing; mechanical properties; bubbles

  • IPEN-DOC 29615

    RIBEIRO, I.L.F.; CARVALHO, G.L.; DIB, L.F.G.; BARBOSA, E.A.; WETTER, N.U. . Vibration amplitude mapping by stroboscopic structured light projection. Optics Communications, v. 531, p. 1-9, 2023. DOI: 10.1016/j.optcom.2022.129219

    Abstract: In this work a method to evaluate the distribution of vibration amplitudes of objects was demonstrated, combining for the first time oblique structured light projection, stroboscopic illumination and fringe evaluation. The light pattern was formed by straight and parallel fringes produced by a slightly misaligned Twyman–Green interferometer illuminated by a 40-mW, 650-nm diode laser. Stroboscopic illumination was achieved by driving the laser with a PWM signal with the same frequency than that of the vibrating object. By evaluating the fringes with phase stepping and phase unwrapping procedures, the amplitude mapping of a formica bar and circular rubber membranes was performed. By averaging the fringe position over the light pulse duration a correction ratio between the actual phase and the measured phase was obtained as a function of the pulse duty cycle, and the dependence of the fringe visibility on the duty cycle was studied. The experiments showed that relatively large amplitudes in a range from tens of millimeters up to few millimeters can be measured.

    Palavras-Chave: optical equipment; evaluation; vibrational states; mechanical vibrations

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.