Navegação Periódicos - Artigos por assunto "radiation sources"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 27125

    BELLEZZO, MURILLO ; FONSECA, GABRIEL P.; VONCKEN, ROBERT; VERRIJSSEN, AN-SOFIE; VAN BEVEREN, CELINE; ROELOFS, ERIK; YORIYAZ, HELIO ; RENIERS, BRIGITTE; VAN LIMBERGEN, EVERT J.; BERB EE, MAAIKE; VERHAEGEN, FRANK. Advanced design, simulation, and dosimetry of a novel rectal applicator for contact brachytherapy with a conventional HDR 192Ir source. Brachytherapy, v. 19, n. 4, p. 544-553, 2020. DOI: 10.1016/j.brachy.2020.03.009

    Abstract: PURPOSE: Dose escalation yields higher complete response to rectal tumors, which may enable the omission of surgery. Dose escalation using 50 kVp contact x-ray brachytherapy (CXB) allow the treatment of a selective volume, resulting in low toxicity and organs-at-risk preservation. However, the use of CXB devices is limited because of its high cost and lack of treatment planning tools. Hence, the MAASTRO applicator (for HDR 192Ir sources) was developed and characterized by measurements and Monte Carlo simulations to be a cost-effective alternative to CXB devices. METHODS AND MATERIALS: A cylindrical applicator with lateral shielding was designed to be used with a rectoscope using its tip as treatment surface. Both the applicator and the rectoscope have a slanted edge to potentially allow easier placement against tumors. The applicator design was achieved by Monte Carlo modeling and validated experimentally with film dosimetry, using the Papillon 50 (P50) device as reference. RESULTS: The applicator delivers CXB doses in less than 9 min using a 20375 U source for a treatment area of approximately 20 20 mm2 at 2 mm depth. Normalized at 2 mm, the dose falloff for depths of 0 mm, 5 mm, and 10 mm are 130%, 70%, and 43% for the P50 and 140%, 67%, and 38% for the MAASTRO applicator, respectively. CONCLUSIONS: The MAASTRO applicator was designed to use HDR 192Ir sources to deliver a dose distribution similar to those of CXB devices. The applicator may provide a cost-effective solution for endoluminal boosting with clinical treatment planning system integration.

    Palavras-Chave: brachytherapy; monte carlo method; rectal administration; iridium 192; dose rates; radiation sources; simulation; radiotherapy; neoplasms; film dosimetry

  • IPEN-DOC 09562

    LIMA, R.B.; YORIYAZ, H. ; HERNANDES, A.C.; MADI FILHO, T. . Avaliacao experimental do fluxo de neutrons de um irradiador com fontes de AmBe e sua possibilidade de uso em analise de materiais. Revista Brasileira de Pesquisa e Desenvolvimento, v. 5, n. 2, p. 43-48, 2003.

    Palavras-Chave: neutron flux; neutrons; irradiation devices; radiation sources; americium; beryllium; nondestructive analysis; neutron activation analysis; experimental data; monte carlo method; comparative evaluations

  • IPEN-DOC 03373

    CALDAS, L.V.E. ; DAVID, J.. Bremsstrahlung and beta radiation fields determination of an industrial radioactive source. Radiation Protection Dosimetry, v. 27, n. 1, p. 47-51, 1989.

    Palavras-Chave: bremsstrahlung; krypton 85; beta particles; radiation sources

  • IPEN-DOC 09359

    OLIVEIRA, M.L.; CALDAS, L.V.E. . Calibracao de um aplicador dermatologico de sup(99)Sr+sup(90)Y. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1Parte 1, p. 898-901, 2002.

    Palavras-Chave: radiation sources; strontium 90; yttrium 90; skin; wounds; calibration; extrapolation chambers; beta dosimetry; beta detection

  • IPEN-DOC 26926

    CAZULA, C.D. ; CAMPOS, M.P. ; MAZZILLI, B.P. . Calibração de detectores sólidos de traços nucleares do tipo CR-39 para medidas de Rn-222 no ar. Brazilian Journal of Radiation Sciences, v. 3, n. 1A, p. 1-8, 2015. DOI: 10.15392/bjrs.v3i1A.174

    Abstract: No método de detecção com detectores sólidos de traços nucleares, quando uma partícula pesada incide sobre a superfície do detector, provoca um desarranjo em sua estrutura molecular formando um traço. Uma das aplicações mais comuns desses detectores está na medição da concentração de Rn-222 no ar, um gás nobre radioativo, membro da série do U-238, emissor de partículas alfa e importante em estudos epidemiológicos para proteção dos indivíduos à radiação natural. Para determinar a concentração de Rn-222 no ar em um ambiente é necessário conhecer a densidade de traços (traços/cm2) na superfície do detector, o tempo de exposição e o fator de calibração. A determinação do fator calibração para os detectores CR-39 foi feita a partir da exposição destes a uma concentração conhecida de Rn-222. Para tanto, os detectores foram inseridos no interior de uma célula de Lucas adaptada e posteriormente expostos a uma concentração de Rn-222 de 15 kBq/m3, por meio do aparelho RN-150 da Pylon Eletronics Incorporation, que possui uma fonte de Ra-226 e libera concentrações conhecidas de Rn-222. Foram realizadas seis determinações do fator de calibração, o valor médio obtido foi de 0,0534 ± 0,0021 (traços/cm2 por Bq/m3 dia). Os resultados são compatíveis com os valores da literatura para o mesmo tipo de detector e apresentaram boa reprodutibilidade.

    Palavras-Chave: calibration; concentration ratio; experimental data; optical microscopy; particle tracks; radiation detectors; radiation sources; radon 222; radon 226

  • IPEN-DOC 11421

    CALDAS, LINDA V.E. ; OLIVEIRA, MERCIA L.. Caracteristicas pre-operacionais de uma mini-camara de extrapolacao para calibracao de fontes de Sr90+Y90. Revista Brasileira de Fisica Medica, v. 1, n. 1, p. 20-26, 2005.

    Palavras-Chave: brazilian cnen; extrapolation chambers; strontium 90; yttrium 90; beta dosimetry; calibration standards; radiation sources

  • IPEN-DOC 18351

    SILVA, ERIC A.B. da; CALDAS, LINDA V.E. . Characterization of an extrapolation chamber in X ray beams, diagnostic radiology level. Radioproteção, v. 2, n. 20, p. 83-90, 2012.

    Palavras-Chave: extrapolation chambers; calibration standards; radiation detectors; x radiation; radiation sources; diagnostic techniques

  • IPEN-DOC 24419

    SILVA JUNIOR, I.A. ; SIQUEIRA, P.T.D. ; NASCIMENTO, E.; VIVOLO, V. ; POTIENS, M.P.A. . Comparação entre duas metodologias para correção da uniformidade de fontes extensas de referência. Brazilian Journal of Radiation Sciences, v. 05, n. 03-A, p. 01-09, 2017.

    Abstract: São apresentados neste artigo os procedimentos para obtenção de fatores de correção de uniformidade de fontes ex- tensas de referência sugerida por duas metodologias distintas. A primeira metodologia é apresentada pelo Guia de Boas Práticas do Nº 14 do NPL, que oferece uma correção numérica e a segunda é uma correção que utiliza o código de transporte de radiação, MCNP5. Ambos os métodos resultam na proposição de valores de correções muito simila- res percentualmente, com desvio máximo de 0,24%.

    Palavras-Chave: carbon 14; comparative evaluations; corrections; iso; monte carlo method; radiation protection; radiation sources

  • IPEN-DOC 27803

    CABRAL, T.S.; LARANJEIRA, A.S.; POTIENS, M.P.A. ; SOARES, C.M.A.; KHOURY, H.; SAITO, V.; DAVID, M.; VIDAL, L.C.; PIRES, M.A.. Comparison of calibration of surface contamination monitors with Brazilian Network - 2018/2019. Journal of Physics: Conference Series, v. 1826, p. 1-6, 2021. DOI: 10.1088/1742-6596/1826/1/012039

    Abstract: This work reports the results obtained from the comparison involving 7 laboratories in Brazil. This exercise is about the calibration service of surface contamination monitors. The monitor has been calibrated to BS ISO 7503-3, the calibration factor in terms of surface emission rate. The comparison was conducted by the Brazilian National Laboratory of Ionizing Radiation Metrology (LNMRI / IRD) from October 2018 to July 2019. The extensive sources used were 14C, 137Cs, 60Co, 90Sr/90Y, 36Cl and 241Am. The result of this proficiency test was excellent and proved the calibration capacity of the Brazilian network in the calibration service for surface contamination monitors.

    Palavras-Chave: calibration standards; interlaboratory comparisons; iso; radiation protection; radiation sources; surface contamination monitors

  • IPEN-DOC 18041

    ANTONIO, PATRICIA L.; CARVALHO, VALDIR S. ; CALDAS, LINDA V.E. . Comparison of calibration results for an extrapolation chamber obtained with different sup(90)Sr+sup(90)Y secondary standard sources. Applied Radiation and Isotopes, v. 70, n. 2, p. 388-391, 2012.

    Palavras-Chave: biophysics; dosimetry; external irradiation; extrapolation chambers; radiation hazards; radiation monitoring; radiation protection; radiation sources; reliability; strontium; strontium 90; yttrium; yttrium 90

  • IPEN-DOC 27117

    SILVA JÚNIOR, IREMAR A. ; SIQUEIRA, PAULO de T.D. ; NASCIMENTO, EDUARDO do; YORIYAZ, HELIO ; SORDI, GIAN-MARIA A.A. ; VIVOLO, VITOR ; POTIENS, MARIA da P.A. . Correction factors for non-uniform large-area reference sources. Applied Radiation and Isotopes, v. 160, p. 1-6, 2020. DOI: 10.1016/j.apradiso.2020.109082

    Abstract: Based on uniformity measurements of large-area reference sources used in calibration procedures of surface contamination monitors, an investigation was carried out to obtain a method that estimates the bias originated from surface source intensity distribution deviation from the ideal uniform distribution and corrects it. It relies on correcting the estimated instrument efficiency by applying correction factors driven from the uniformity distribution profiles of the sources used in calibration procedure. Simulations of the monitor calibration procedure are run for 2 distinct surface source distributions: the real and the ideally uniform distributions. Correction factors are driven from counting rate estimates obtained from each source representation. In order to evaluate adequacy of this proposition it was validated against a method proposed by the NPL in the Good Practices Guide No.14.

    Palavras-Chave: corrections; radiation sources; calibration; monte carlo method; numerical data; surface contamination monitors; measuring methods

  • IPEN-DOC 14990

    OLIVEIRA, JUNIOR, O.P. de ; BOLLE, W. de; ALONSO, A.; RICHTER, S.; WELLUM, R.; PONZEVERA, E.; SARKIS, J.E.S. ; KESSEL, R.. Demonstrating the metrological compatibility of uranium isotope amount ratio measurement results obtained by GSMS, TIMS and MC-ICPMS techniques. International Journal of Mass Spectrometry, v. 291, n. 1-2, p. 48-54, 2010.

    Palavras-Chave: uranium isotopes; metrology; compatibility; icp mass spectroscopy; mass spectra; radiation sources; uranium 234; uranium 235; uranium 236; uranium 238; calibration standards

  • IPEN-DOC 21233

    PELEIAS JUNIOR, FERNANDO dos S. ; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. ; FECHINE, GUILHERMINO J.M.; SOUZA, CARLA D. de ; MATTOS, FABIO R. de ; MOURA, EDUARDO S. de ; MOURA, JOAO A. ; BENEGA, MARCOS A.G. ; FEHER, ANSELMO ; COSTA, OSVALDO L. da ; RODRIGUES, BRUNA T. . Desenvolvimento da metodologia para sintese do poli-)acido latico-co-acido glicolico) para utilização na produção de fontes radioativas / Development of methodology for the synthesis of poly(lactic acid-co-glycolic acid) for use in the production of radioactive sources. Polimeros, v. 25, n. 3, p. 317-325, 2015.

    Palavras-Chave: brachytherapy; neoplasms; prostate; glycolic acid; seeds; synthesis; radiation sources; radioactivity; iodine 125; polymers; isotope production; lactic acid

  • IPEN-DOC 19659

    FONSECA, G.P.; RUBO, R.A.; MINAMISAWA, R.A.; SANTOS, G.R. dos; ANTUNES, P.C.G.; YORIYAZ, H. . Determination of transit dose profile for a sup(192)Ir HDR source. Medical Physics, v. 40, n. 5, p. 051717-1 - 051717-8, 2013.

    Palavras-Chave: brachytherapy; computerized simulation; distribution; dose rates; doses; dosimetry; films; iridium 192; irradiation; monte carlo method; optical fibers; radiation sources

  • IPEN-DOC 14089

    ROSTELATO, MARIA E.C.M. ; RELA, PAULO R. ; ZEITUNI, CARLOS A. ; FEHER, ANSELMO ; MANZOLI, JOSE E.; MOURA, JOAO A.; MOURA, EDUARDO S.; SILVA, CONSTANCIA P.G. . Development and production of radioactive sources used for cancer treatment in Brazil. Nukleonika, v. 53, p. S99-S103, 2008.

    Palavras-Chave: irradiation devices; ionizing radiations; brachytherapy; neoplasms; brazil; iodine 125; iridium 192; radiation sources

  • IPEN-DOC 27870

    CARVALHO, D.V.S. ; GREGIANIN, G.M.; MESQUITA, C.H. . Development of an automated source holder in IoT for application in industrial process tomography. Brazilian Journal of Radiation Sciences, v. 9, n. 1A, p. 1-11, 2021. DOI: 10.15392/bjrs.v9i1A.1349

    Abstract: Computed tomography technology uses an electromagnetic radiation source or particulate radiation source, to analyze / study different samples that can range from living organisms to the most diverse objects (rocks, phantoms, etc.). The use of the radioactive materials may cause harm to the operator if he is exposed to the source of radiation, so aiming at the safety of the operator, the objective of this work is to develop an Internet of Things automation system for the opening of the Industrial Process Tomography source holder for industrial tomography applications. Thus, this system can drive the stepper motors through this platform can be opened at a safe distance to the operator, avoiding the operator to take radiation dose to perform this operation. For the IPT project, five source holders were made so that each was positioned diametrically opposite each array of detectors. In this project we used 192Ir sources that have activity of 18,500 MBq and that were produced in the reactor IEA-R1, from the neutron bombardment of the pellet containing stable isotope 191Ir. The main characteristics of 192Ir are: half-life of 74.2 days; radiation energy from 0.13 to 0.65 MeV. For the safety of the operator during the opening of the sources, an automated opening system with IoT that can be activated with software installed on the tomography or by a smartphone application by the MQTT protocol, which makes it possible to be monitored in real time at long distance showing the opening and closing status of each source holder.

    Palavras-Chave: automation; computerized tomography; iridium 192; occupational exposure; openings; radiation protection; radiation sources; remote handling

  • IPEN-DOC 09090

    KOSKINAS, M.F. ; FONSECA, K.A. ; DIAS, M.S. . Disintegration rate measurement of a sup(152)Eu solution. Applied Radiation and Isotopes, v. 56, n. 1/2, p. 441-445, 2002.

    Palavras-Chave: europium 152; standardization; calibration standards; coincidence methods; beta decay; proportional counters; radiation sources; particle decay; high-purity ge detectors

  • IPEN-DOC 18576

    SILVA, JONAS O. da; CALDAS, LINDA V.E. . Establishment of a Tandem ionization chamber system in standard mammography beams. Radioproteção, v. 2, n. 20, p. 125-132, 2012.

    Palavras-Chave: avalanche quenching; biophysics; brazil; dosimetry; external irradiation; ionization chambers; mammary glands; radiation monitoring; radiation protection; radiation sources; safety standards; reliability; safety showers

  • IPEN-DOC 19823

    VICENTE, ROBERTO ; POTIENS JUNIOR, ADEMAR ; SAKATA, SOLANGE ; DELLAMANO, JOSE . Experience in the management of disused lightning rods containing sup(241)Am in a Research Institute in Brazil. Health Physics, v. 105, Sppl. 5, p. S223-S230, 2013.

    Palavras-Chave: brazil; lightning arresters; rods; radiation sources; americium 241; radioactive waste management

  • IPEN-DOC 24798

    SILVEIRA, LUCAS M. da; PEREIRA, MARCO A.M.; NEVES, LUCIO P. ; PERINI, ANA P. ; BELINATO, WALMIR; CALDAS, LINDA V.E. ; SANTOS, WILLIAM S.. Exposure to 137Cs deposited in soil – A Monte Carlo study. Journal of Physics: Conference Series, v. 975, n. 012050, p. 1-5, 2018. DOI: 10.1088/1742-6596/975/1/012050

    Abstract: In the event of an environmental contamination with radioactive materials, one of the most dangerous materials is 137Cs. In order to evaluate the radiation doses involved in an environmental contamination of soil, with 137Cs, we carried out a computational dosimetric study. We determined the radiation conversion coefficients (CC) for effective (E) and equivalent (H T) doses, using a male and a female anthropomorphic phantoms. These phantoms were coupled with the MCNPX (2.7.0) Monte Carlo simulation software, for three different types of soil. The highest CC[H T] values were for the gonads and skin (male) and bone marrow and skin (female). We found no difference for the different types of soil.

    Palavras-Chave: cesium 137; radiation accidents; environmental exposure; contamination; soils; monte carlo method; radiation sources; computer codes; dosimetry; radiation monitoring; radiation protection

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.