Navegação Periódicos - Artigos por assunto "radiations"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 26393

    FERREIRA, EDUARDO G.A. ; MARUMO, JULIO T. ; FRANCO, MARGARETH K.K.D. ; YOKAICHIYA, FABIANO; VICENTE, ROBERTO . 10000 years cement: Can hydrated cement last as much as long-lived radionuclides?. Cement and Concrete Composites, v. 103, p. 339-352, 2019. DOI: 10.1016/j.cemconcomp.2019.05.016

    Abstract: This review is focused on the long-term performance of cementitious materials in a repository for radioactive waste. During the last few years, the disposal of disused sealed radioactive sources (DSRS) in a borehole type repository has been studied by many countries. The borehole concept is particularly useful to dispose of spent nuclear fuel and DSRS. In boreholes for DSRS, cementitious materials are intended to be used as structural material, immobilization matrix and as backfill. The understanding of the performance of these materials is essential to ensure the safety of the facilities during their required lifetime, from centuries to many thousands of years, depending on the initial activity and half-life of the waste. This review approaches the behavior of the cement from the hydration and hardening to the long-term processes that can affect its durability. Three main causes of failure of repository-engineered barriers are recognized: a) the formation of a preferential pathway for the migration of the contained radionuclides to the biosphere; b) loss of resistance and cohesion of the structural cementitious material; and c) the increase in the corrosion processes of the metallic components of the structures that affect the overall containment of the facility.

    Palavras-Chave: cement industry; portland cement; radioactive wastes; geologic formations; underground disposal; performance; chemical composition; mineralogy; radiations; magnetic fields; hydration

  • IPEN-DOC 17278

    COELHO, TALITA S.; FERNANDES, MARCO A.R.; YORIYAZ, HELIO ; LOUZADA, MARIO J.Q.. Analise dosimétrica de perfis de distribuições radiais de doses relativas de um aplicador de betaterapia de sup(90)Sr+sup(90)Y utilizando o código MCNP-4C e filmes radiocrônicos. Revista Brasileira de Fisica Medica, v. 4, n. 3, p. 7-10, 2011.

    Palavras-Chave: beta dosimetry; dose equivalents; dosimetry; films; m codes; measuring methods; radiation detection; radiation dose distributions; radiation dose units; radiation doses; radiation monitoring; radiation protection; radiations; strontium; strontium 90; yttrium; yttrium 90

  • IPEN-DOC 25736

    FONTES, LADYJANE P. ; CORREA, EDUARDO L. ; POTIENS, MARIA da P.A. . Application of a Tandem system for HVL evaluation in computed tomography. Radiation Physics and Chemistry, v. 155, p. 62-64, 2019. DOI: 10.1016/j.radphyschem.2018.08.023

    Abstract: Computed tomography (CT) is a method of imaging used for the diagnosis and treatment of diseases. Different from the conventional diagnostic radiology equipment, where the test for the determination of the half value layer (HVL) is recommended, in CT equipment due to its geometry, the determination of the HVL is a difficult task and is usually only provided by the manufacturer. The effective energy of a beam is determined by definition, by means of HVL determination. When HVL values are not easily determined, as in the case of CT, it is possible to evaluate the effective energy of the beam through a system consisting of the use of different energy dependent dosimeters, where the ratio between the calibration curve responses in energy can provide the effective energy of the beam (Tandem system). The system used in this work for the evaluation of HVL in computed tomography is composed of groups formed by an ionization chamber of the pencil-type and cylindrical absorber layers of aluminum and Polymethyl methacrylate (PMMA).

    Palavras-Chave: tomography; computerized tomography; radiations; radiation chemistry; ionization chambers; pmma

  • IPEN-DOC 27360

    ALVARENGA, TALLYSON S. ; POLO, IVON O. ; PEREIRA, WALSAN W.; MAYHUGH, MICHAEL R.; CALDAS, LINDA V.E. . Application of the Reduced-Fitting Method to determine neutron scattering. Radiation Physics and Chemistry, v. 179, p. 1-8, 2021. DOI: 10.1016/j.radphyschem.2020.109207

    Abstract: As the number of techniques using neutron radiation has grown, the number of neutrons detectors has increased along with need for their calibration. In Brazil this substantial demand for neutron detector calibration falls on a single laboratory located in Rio de Janeiro. One of the major problems in the calibration of neutron detectors is neutron scattering, which varies depending on the size and configuration of the laboratory. This is due to the neutrons that interact with the experimental setup and the surrounding, walls, floor and ceiling. This scatter influences the reading of the instrument to be calibrated and causes systematic errors in the calibration of neutron detectors. ISO 8529-2 recommends the following methods to correct these effects: The Semi-Empirical Method (SEM), the Reduced-Fitting Method (RFM), the Shadow-Cone Method (SCM) and the Generalized Fit Method (GFM). In this study, the neutron scattering characterization was performed in the Neutron Calibration Laboratory (LCN) of IPEN/CNEN, using the RFM method. The neutron source used was 241AmBe, which was positioned in the center of the calibration room. Neutron spectra were obtained using a scintillation detector based on 6Lil(Eu) in combination with a Bonner sphere spectrometer (BSS) at source-detector distances from 30 cm to 258 cm.

    Palavras-Chave: scattering; neutrons; radiations; neutron detectors; calibration; calculation methods; bonner sphere spectrometers; neutron spectra

  • IPEN-DOC 20230

    ANTONIO, PATRICIA L. ; XAVIER, MARCOS ; CALDAS, LINDA V.E. . Bohm extrapolation chamber: Study of itas behavior in beta radiation fields at the Calibration Laboratory of IPEN. Radiation Physics and Chemistry, v. 104, p. 310-315, 2014.

    Palavras-Chave: brazilian cnen; laboratories; extrapolation chambers; dosimetry; calibration; strontium 90; yttrium 90; radiation detectors; aluminium; mylar; windows; comparative evaluations; radiations; beta sources

  • IPEN-DOC 19968

    ANTONIO, PATRICIA L.; OLIVEIRA, MERCIA L.; CALDAS, LINDA V.E. . Calibration of the sup(90)Sr+sup(90)Y ophthalmic and dermatological applicators with an extrapolation ionization minichamber. Applied Radiation and Isotopes, v. 85, p. 11-13, 2014.

    Palavras-Chave: calibration; strontium 90; yttrium 90; skin diseases; eyes; sense organs diseases; ionization chambers; extrapolation chambers; radiations; beta sources

  • IPEN-DOC 27802

    VILLANI, D. ; SAVI, M. ; ANDRADE, M.A.B.; CAMPOS, L.L. ; POTIENS, M.P.A. . Characterization of ABS + W and ABS + Bi 3D printing filaments attenuation for different photon beams. Journal of Physics: Conference Series, v. 1826, p. 1-8, 2021. DOI: 10.1088/1742-6596/1826/1/012037

    Abstract: 3D printing techniques and materials have become widely available in the last couple of decades and remains a hot topic of study as new materials can lead to new applications. This study aims to evaluate the attenuation behaviour of GMASS over photon beams ranging from 29.7 up to 661.7keV, comparing with pure ABS and using theoretical data of pure lead as reference. It was used the transmission method to obtain experimental attenuation coefficients to all materials and theoretical data. HVL and TVL calculations were also performed. Results show that ABS+W has higher attenuation than ABS+Bi and pure ABS. Using the lead theoretical reference data it can be concluded that although ABS+Bi and ABS+W attenuates less than pure lead, the 3D printing filaments can be used to create shielding tolls depending on radiation energy and application.

    Palavras-Chave: attenuation; cesium 137; dosimetry; energy dependence; filaments; photon beams; polymers; radiations; shielding

  • IPEN-DOC 19576

    HUBERT, G.; VELAZCO, R.; FEDERICO, C.; CHEMINET, A.; SILVA CARDENAS, C.; CALDAS, L.V.E. ; PANCHER, F.; LACOSTE, V.; PALUMBO, F.; MANSOUR, W.; ARTOLA, L.; PINEDA, F.; DUZELLIER, S.. Continuous high-altitude measuremts of cosmic ray neutrons and SEU/MCU at various locations: correlation and analyses based-on MUSCA SEPsup(3). IEEE Transactions on Nuclear Science, v. 60, n. 4, p. 2418-2426, 2013.

    Palavras-Chave: atmospheric chemistry; cosmic radiation; neutrons; stratosphere; radiations; neutron spectrometers; elements

  • IPEN-DOC 12261

    WILLEGAIGNON, J.; GUIMARAES, MARIA I.C.; STABIN, MICHAEL G.; SAPIENZA, MARCELO T.; MALVESTITI, LUIZ F.; MARONE, MARILIA M.S.; SORDI, GIAN M.A.A.. Correction factors for more accurate estimates of exposure rates near radioactive patients: experimental, point and line source model. Health Physics, v. 93, p. 678-688, 2007.

    Palavras-Chave: iodine 131; thyroid; radiation doses; radioactivity; patients; radiations

  • IPEN-DOC 13132

    TEIXEIRA, M.I.; FERRAZ, GILBERTO M.; CALDAS, LINDA V.E. . Descalvado sand for high-dose dosimetry. Radiation Measurements, v. 43, p. 1163-1165, 2008.

    Palavras-Chave: sand; radiations; dosimetry; electron spin resonance

  • IPEN-DOC 25754

    CAVALIERI, TASSIO A. ; SIQUEIRA, PAULO T.D. ; SHORTO, JULIAN M.B. ; GENEZINI, FREDERICO A. ; YORIYAZ, HELIO . Design, fabrication and modeling of an AmBe neutron irradiator for TLD screening for neutron dose measurement in mixed radiation fields. Applied Radiation and Isotopes, v. 150, p. 31-38, 2019. DOI: 10.1016/j.apradiso.2019.05.009

    Abstract: TLDs dosimeters are frequently presented as a viable choice for dosimetric studies when dealing with mixed neutron-gamma radiation fields. However, this choice is not without some drawbacks, because not only TLD response is highly dependent on particle type but also on neutron energy spectrum. Therefore, a correct screening and calibration of the dosimeter are required, and a simple shift from gamma screening methodology for mixed field is not suitable. This paper presents the design, fabrication and tests of an irradiator for TLD screening for neutron dose measurement using an AmBe source and polyethylene as moderator material. The design of the irradiator was conducted through Monte Carlo simulations using the MCNP5 code. The experimental validation and tests were performed using Indium activation foils and TLD 600 dosimeters. The manufactured irradiator demonstrated to be suitable for TLD screening under neutron source radiation field, offering very good homogeneity conditions in the radiation field so to guarantee same radiation dose delivered to the TLDs.

    Palavras-Chave: dosemeters; thermoluminescent dosemeters; monte carlo method; neutron activation analysis; radiations

  • IPEN-DOC 25130

    POLO, IVON O. ; SANTOS, WILLIAM de S. ; CALDAS, LINDA V.E. . Determination of correction factors in beta radiation beams using Monte Carlo method. Applied Radiation and Isotopes, v. 140, p. 50-54, 2018. DOI: 10.1016/j.apradiso.2018.06.011

    Abstract: The absorbed dose rate is the main characterization quantity for beta radiation. The extrapolation chamber is considered the primary standard instrument. To determine absorbed dose rates in beta radiation beams, it is necessary to establish several correction factors. In this work, the correction factors for the backscatter due to the collecting electrode and to the guard ring, and the correction factor for Bremsstrahlung in beta secondary standard radiation beams are presented. For this purpose, the Monte Carlo method was applied. The results obtained are considered acceptable, and they agree within the uncertainties. The differences between the backscatter factors determined by the Monte Carlo method and those of the ISO standard were 0.6%, 0.9% and 2.04% for 90Sr/90Y, 85Kr and 147Pm sources respectively. The differences between the Bremsstrahlung factors determined by the Monte Carlo method and those of the ISO were 0.25%, 0.6% and 1% for 90Sr/90Y, 85Kr and 147Pm sources respectively.

    Palavras-Chave: extrapolation chambers; radiations; monte carlo method; backscattering; bremsstrahlung; beta dosimetry

  • IPEN-DOC 24674

    POLO, IVON O. ; CALDAS, LINDA V.E. . Determination of transmission factors in beta radiation beams. Applied Radiation and Isotopes, v. 136, p. 82-86, 2018. DOI: 10.1016/j.apradiso.2018.02.010

    Abstract: In beta emitters, in order to evaluate the absorbed dose rate at different tissue depths, it is necessary to determine the transmission factors. In this work, the transmission factors determined in beta secondary standard radiation beams are presented. For this purpose, an extrapolation chamber was used. The results obtained were considered acceptable, and they are within the uncertainties in comparison with the values provided by the source calibration certificate. The maximum differences between the results obtained in this work and those from the calibration certificate were 3.3%, 3.8% and 5.9% for 90Sr/90Y, 85Kr and 147Pm sources respectively.

    Palavras-Chave: absorbed radiation doses; dose rates; extrapolation chambers; krypton 85; promethium 147; radiations; strontium 90; transmission; yttrium 90

  • IPEN-DOC 11798

    FRIMAIO, AUDREW; COSTA, PAULO R.; VANDERLINDE, FLAVIA V.F.; CAMPOS, LETICIA L. . Development of a ceramic compound for coating the walls of image diagnosis centers for dose reduction of the medical team. International Journal of Low Radiation, v. 3, n. 4, p. 355-362, 2006.

    Palavras-Chave: ceramics; coatings; shielding; images; diagnosis; radiations; attenuation; x-ray sources

  • IPEN-DOC 14168

    LOPERGOLO, L.C.; LUGAO, A.B. ; CATALANI, L.H.. Development of a poly(N-vinyl-2-pyrrolidone)/poly (ethylene glycol) hydrogel membrane reinforced with methyl methacrylate-grafted polypropylene fibers for possible use as wound dressing. Journal of Applied Polymer Science, v. 86, n. 3, p. 662-666, 2002.

    Palavras-Chave: hydrogels; mechanical properties; radiations; biological materials; membranes

  • IPEN-DOC 27206

    VILLANI, D. ; RODRIGUES JUNIOR, O. ; CAMPOS, L.L. . Dosimetric characterization of 3D printed phantoms at different infill percentages for diagnostic X-ray energy range. Radiation Physics and Chemistry, v. 172, p. 1-6, 2020. DOI: 10.1016/j.radphyschem.2020.108728

    Abstract: The aim of this paper is to characterize 3D printed phantoms and printing set-ups with different infill percentages for imaging energy X-ray beams attenuation. 3D printing performance was studied using the fused filament fabrication (FFF) technique with PLA (Polylactic Acid) and ABS (Acrylonitrile Butadiene Styrene) filaments. Phantom plates were printed and, using the Pantak Seifert X-ray system with different beam qualities in the diagnostic range, the attenuation coefficients were obtained experimentally with the transmission method and results compared with PMMA used as reference and theoretical data. Different percentages of infill of printed phantoms were also evaluated and transmission characterized. The attenuation coefficients were determined for the different beam qualities and results show that the variation in the values of attenuation coefficients decreases as the infill quality increases. Attenuation characteristics evaluated indicates the suitable equivalence of PLA to PMMA for 3D printing water/tissue equivalent most complex geometry phantoms. The different printing modes characterized together with their attenuation coefficients for the X-ray beams will be studied and used in the development of new 3D printed phantoms in our institute.

    Palavras-Chave: phantoms; computer codes; x-ray sources; lactic acid; dosimetry; acrylonitrile; butadiene; styrene; radiations; beams

  • IPEN-DOC 23528

    MACHI, ANDRE R. ; ARTHUR, VALTER ; SARRIES, GABRIEL A.; PIEDADE, SONIA M. de S.. Effect of gamma irradiation of gravid Tetranychus desertorum, T. urticae and Oligonychus ilicis (Trombidiformes: Tetranychidae) females on the viabilities and durations of F1 life stages. Florida Entomologist, v. 99, special issue 2, p. 186-190, 2016.

    Abstract: The objective of the study was to evaluate—as an alternative phytosanitary treatment—the effects of gamma irradiation of gravid spider mite females on the viabilities and durations of F1 eggs and deutonymphs. The study focused on Tetranychus urticae Koch, Tetranychus desertorum Banks and Oligonychus ilicis (McGregor) (Trombidiformes: Tetranychidae). Each mite species was identified under a stereomicroscope, and individual female mites of each species were each taken with a fine-tipped brush and transferred to a Petri dish—i.e., 1 female mite individualized per dish with 32 dishes per species. Each dish with a Tetranychus spp. female was provided with a jack bean (Canavalia ensiformis [L.] DC) (Fabales: Fabaceae) leaf, and each dish with an O. ilicis female was provided with a coffee (Coffea arabica L.; Gentianales: Rubiaceae) leaf. Gravid female mites were irradiated in a Gammacell 220 cobalt-60 source—dose rate 0.486 kGy/h—with doses of 0 (control), 100, 200, 300, and 400 Gy with 32 replications per mite species. Evaluations were made every 24 h for 22 d after irradiation by counting the numbers of eggs, deutonymphs, and adults and by recording the mortality in each stage. Statistical analyses were done with generalized linear models with either the quasi-binomial distribution or the Gaussian distribution—as appropriate—for analyses of mortality rates and durations (d) of the F1 eggs and deutonymphs of the 3 mite species. A 3 × 5 factorial experimental design was used in which factor A (3 levels) pertained to the species and factor B (5 levels) pertained to the 4 radiation doses plus the control. For Factor B polynomial regressions of dose rates on biological effects were used. The results showed progressive decreases in egg and deutonymph viabilities that were proportional with progressive increases in radiation doses. Against O. ilicis 200 Gy prevented all F1 neonates from developing beyond the first instar. Against T. urticae and T. desertorum 300 Gy prevented all F1 neonates from developing beyond the first instar. Irradiation of gravid females caused the durations of the F1 egg stage and the F1 deutonymph stage to be prolonged.

    Palavras-Chave: ionizing radiations; gamma radiation; mites; radiations; biological effects

  • IPEN-DOC 22604

    HAYASHI, TORU; KIKUCHI, OLIVIA K. ; DOHINO, TOSHIYUKI. Electron beam disinfestation of cut flowers and their radiation tolerance. Radiation Physics and Chemistry, v. 51, n. 2, p. 175-179, 1998.

    Palavras-Chave: reviews; electron beams; disinfestation; flowers; radiations; tolerance; pest eradication; pest control; comparative evaluations; irradiation; gamma radiation

  • IPEN-DOC 25724

    HARIANTO, R.E.; HONG, T.T.; MAITRE, A.; PERINI, E.A. ; QIN, X.; RODRIGUEZ, M.R.; SANTOS, N.O. ; SKOPCHENKO, M.; YINGLEI, G.; STAROVOITOVA, V.N.. Establishing radioisotope and radiopharmaceutical production facilities in developing countries. World Council on Isotopes Newsletter, v. 7, n. 2, p. 7-14, 2018.

    Palavras-Chave: radioisotopes; radiopharmaceuticals; production; cyclotrons; protons; radiations; isotope production; industrial plants; developing countries

  • IPEN-DOC 24237

    ALVARENGA, T.S. ; FEDERICO, C.A.; VALERIANO, C.C. ; CALDAS, L.V.E. . Estimativa computacional da radiação espalhada no laboratório de calibração com nêutrons do IPEN. Brazilian Journal of Radiation Sciences, v. 05, n. 03-A, p. 01-10, 2017. DOI: 10.15392/bjrs.v5i3.274

    Abstract: Com o aumento do uso de técnicas que utilizam radiação de nêutrons, houve um crescimento considerável no número de detectores para esse tipo de radiação. Para ajudar a atender à demanda de calibração desse tipo de detector, foi proje-tado um laboratório de calibração de detectores com nêutrons, com fonte de 241AmBe. Neste tipo de laboratório, um dos problemas principais está relacionado ao conhecimento da radiação espalhada, que é significativa neste tipo de ativida-de. Com o intuito de estimar esta radiação espalhada de maneira a balizar a configuração final do laboratório, foram realizadas simulações computacionais utilizando-se o método de Monte Carlo por meio do código MCNP5. As simula-ções foram realizadas modelando o ambiente do laboratório sem a presença dos elementos estruturais e com a sala completa, de maneira a avaliar o fluxo de nêutrons e equivalente de dose ambiente, H*(10), em quatorze posições de especial interesse dentro da instalação. Com base nos resultados, foram avaliadas as limitações e as condições a serem observadas para o uso pretendido do laboratório.

    Palavras-Chave: neutron detectors; radiations; calibration; monte carlo method; scattering

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.