JavaScript is disabled for your browser. Some features of this site may not work without it.
Navegação Periódicos - Artigos por assunto "x radiation"
-
SILVA, LUIS C.C. da; INFANTE, CARLOS M.C.; URIO, RICARDO de P.; COSENTINO, IVANA C.
; FANTINI, MARCIA C. de A.; MATOS, JIVALDO do R.; NASCIMENTO, FERNANDO H. do; MASINI, JORGE C..
Adsorption/desorption of Hg(II) on FDU-1 silica and FDU-1 silica Modified with humic acid.
Separation Science and Technology,
v. 50,
n. 7,
p. 984-992,
2015.
Palavras-Chave:
silica;
adsorption;
voltametry;
desorption;
mercury;
organic acids;
chemical preparation;
thermal gravimetric analysis;
small angle scattering;
x radiation;
adsorption isotherms
SILVA, LUIS C.C. da; INFANTE, CARLOS M.C.; URIO, RICARDO de P.; COSENTINO, IVANA C.; FANTINI, MARCIA C. de A.; MATOS, JIVALDO do R.; NASCIMENTO, FERNANDO H. do; MASINI, JORGE C.
Adsorption/desorption of Hg(II) on FDU-1 silica and FDU-1 silica Modified with humic acid.
Separation Science and Technology,
v. 50,
n. 7,
p. 984-992,
2015.
Disponível em: http://repositorio.ipen.br/handle/123456789/26491. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
LUCENA, RODRIGO F.; POTIENS, MARIA da P.A.
.
Análise dos efeitos da filtração adicional em feixes de raios X a partir dos cálculos de energia média por fóton em espectros de raios X.
Revista Brasileira de Fisica Medica,
v. 5,
n. 3,
p. 239-244,
2012.
Palavras-Chave:
biomedical radiography;
diagnostic techniques;
solid scintillation detectors;
x radiation;
x-ray spectra;
x-ray spectroscopy;
x-ray tubes
LUCENA, RODRIGO F.; POTIENS, MARIA da P.A.
Análise dos efeitos da filtração adicional em feixes de raios X a partir dos cálculos de energia média por fóton em espectros de raios X.
Revista Brasileira de Fisica Medica,
v. 5,
n. 3,
p. 239-244,
2012.
Disponível em: http://repositorio.ipen.br/handle/123456789/4186. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SARTORIS, C.E.; CALDAS, L.V.E.
.
Aplicacao de metodologia dosimetrica de feixes terapeuticos de raios X com sistema Tandem.
Radiologia Brasileira,
v. 34,
n. 6,
p. 337-342,
2001.
DOI:
10.1590/S0100-39842001000600007
Palavras-Chave:
x radiation;
x-ray dosimetry;
ionization chambers;
quality control;
half-thickness;
radiotherapy
SARTORIS, C.E.; CALDAS, L.V.E.
Aplicacao de metodologia dosimetrica de feixes terapeuticos de raios X com sistema Tandem.
Radiologia Brasileira,
v. 34,
n. 6,
p. 337-342,
2001.
DOI:
10.1590/S0100-39842001000600007.
Disponível em: http://repositorio.ipen.br/handle/123456789/6175. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VENEZIANI, G.R.
; CORREA, E.L.
; POTIENS, M.P.A.
; CAMPOS, L.L.
.
Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams.
Journal of Physics: Conference Series,
v. 733,
p. 1-6,
2016.
DOI:
10.1088/1742-6596/733/1/012088
Abstract:
IAEA code of practice TRS-457 states that standard phantoms should offer the same primary attenuation and scatter production as relevant body section of a representative patient. Material cost, availability and dimensional stability must also be considered. The goal of this study is to determine the attenuation coefficient of printed ABS and PLA samples in standard X-ray beams, verifying if phantoms printed with these materials could be an easier-handle substitute for PMMA, enabling the creation of different designs in an easier and cheaper way. Results show that PMMA presents higher attenuation coefficient, followed by PLA and ABS, which means that thinner PMMA layer creates higher radiation attenuation.
Palavras-Chave:
attenuation;
availability;
design;
layers;
patients;
phantoms;
pmma;
radiology;
stability;
standards;
x radiation
VENEZIANI, G.R.; CORREA, E.L.; POTIENS, M.P.A.; CAMPOS, L.L.
Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams.
Journal of Physics: Conference Series,
v. 733,
p. 1-6,
2016.
DOI:
10.1088/1742-6596/733/1/012088.
Disponível em: http://repositorio.ipen.br/handle/123456789/27807. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, M.V.L.; SAVI, M.
; ANDRADE, M.A.B.; VILLANI, D.
; POTIENS, M.P.A.
; BRANCO, H.S.; UBEDA, C.; MDLETSHE, S..
Attenuation properties of common 3D printed FFF plastics for mammographic applications.
Brazilian Journal of Radiation Sciences,
v. 10,
n. 1,
p. 1-17,
2022.
DOI:
10.15392/bjrs.v10i1.1732
Abstract:
The aim of this study was to evaluate the feasibility of using acrylonitrile butadiene styrene (ABS) and polylactic
acid (PLA) 3D printing filaments as materials for mammography phantom construction, comparing their
attenuation properties at two different set-ups: at a Calibration Laboratory and directly to a mammography
unit. The attenuation of 3D printed test phantoms of two types of common 3D printing Fused Filament
Fabrication (FFF) filaments (ABS and PLA) were characterized in comparison with polymethylmethacrylate
(PMMA). The measurements were carried out with standard IEC 61267 X-rays, using RQR 2-M and RQR 4-M
beam qualities at the Instruments Calibration Laboratory, and then applied to a mammography unit, with
measurements with 28 kV and 35 kV. Attenuation characteristics evaluated indicate the suitable equivalence of
PLA to PMMA for 3D printing breast complex phantoms. The plastic materials used in this study suggest that
the FFF technique may be suitable for mammography phantom development.
Palavras-Chave:
3d printing;
acrylonitrile;
animal tissues;
attenuation;
butadiene;
filaments;
mammary glands;
phantoms;
pmma;
styrene;
x radiation
OLIVEIRA, M.V.L.; SAVI, M.; ANDRADE, M.A.B.; VILLANI, D.; POTIENS, M.P.A.; BRANCO, H.S.; UBEDA, C.; MDLETSHE, S.
Attenuation properties of common 3D printed FFF plastics for mammographic applications.
Brazilian Journal of Radiation Sciences,
v. 10,
n. 1,
p. 1-17,
2022.
DOI:
10.15392/bjrs.v10i1.1732.
Disponível em: http://repositorio.ipen.br/handle/123456789/32958. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
YOSHIZUMI, MAIRA T.; YORIYAZ, HELIO
; CALDAS, LINDA V.E.
.
Backscattered radiation into a transmission ionization chamber: measurement and Monte Carlo simulation.
Applied Radiation and Isotopes,
v. 68,
n. 4-5,
p. 586-588,
2010.
Palavras-Chave:
accuracy;
backscattering;
collimators;
ionization chambers;
monitors;
monte carlo method;
transmission;
x radiation
YOSHIZUMI, MAIRA T.; YORIYAZ, HELIO; CALDAS, LINDA V.E.
Backscattered radiation into a transmission ionization chamber: measurement and Monte Carlo simulation.
Applied Radiation and Isotopes,
v. 68,
n. 4-5,
p. 586-588,
2010.
Disponível em: http://repositorio.ipen.br/handle/123456789/4703. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
AMATO-LOURENCO, LUIS F.; LOBO, DEBORA J.A.; GUIMARAES, ELIANE T.; MOREIRA, TIANA C.L.; CARVALHO-OLIVEIRA, REGIANI; SAIKI, MITIKO
; SALDIVA, PAULO H.N.; MAUAD, THAIS.
Biomonitoring of genotoxic effects and elemental accumulation derived from air pollution in community urban gardens.
Science of the Total Environment,
v. 575,
p. 1438-1444,
2017.
DOI:
10.1016/j.scitotenv.2016.09.221
Abstract:
Urban gardening is a growing global phenomenon with a positive impact on society. Despite several associated benefits, growing vegetables in urban gardens that are localized in highly polluted areas poses questions about the safety of the produced food. Therefore, the identification of risk factors that result in possible deleterious effects to human health is important for realizing all of the benefits to society. We evaluated the use of two-biomonitoring methods in ten urban gardens of Sao Paulo city and one control site: the micronuclei frequencies for early tetrads of Tradescantia pallida (Rose) Hunt. cv. "Purpurea" Boom(hereafter, Trad-MCN) as a short-term indicator of genotoxic response and tree barks to quantify the accumulation of traffic-related chemical elements as a long-term biomarker of air pollution in urban gardens. Mature plants of Tradescantia pallida were exposed in each garden, and their inflorescences were sampled over three months. A random set of 300 early tetrads in 13 to 21 slides per garden were evaluated for micronuclei frequencies. Elemental concentrations in 428 tree barks samples from 107 different trees in the areas surrounding urban gardens were quantified using an energy dispersive X-ray fluorescence spectrometer. The frequency of Trad-MCN has a significant correlation with traffic variables and chemical elements related to road dust and tailpipe emissions deposited in tree barks. Negative associations between Trad-MCN and both the distance through traffic and the presence of vertical obstacles were observed in the community gardens. The Mn/Zn concentrations in tree barks were associated with increased Trad-MCN.
Palavras-Chave:
air pollution;
bark;
biological markers;
buildup;
communities;
gardening;
public health;
toxicity;
trees;
urban areas;
x radiation;
x-ray spectrometers;
brazil
AMATO-LOURENCO, LUIS F.; LOBO, DEBORA J.A.; GUIMARAES, ELIANE T.; MOREIRA, TIANA C.L.; CARVALHO-OLIVEIRA, REGIANI; SAIKI, MITIKO; SALDIVA, PAULO H.N.; MAUAD, THAIS.
Biomonitoring of genotoxic effects and elemental accumulation derived from air pollution in community urban gardens.
Science of the Total Environment,
v. 575,
p. 1438-1444,
2017.
DOI:
10.1016/j.scitotenv.2016.09.221.
Disponível em: http://repositorio.ipen.br/handle/123456789/27905. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MAIA, A.F.; CALDAS, L.V.E.
.
Calibracao de uma camara tipo lapis em feixes padroes de raios-X.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 4,
n. 3,
Parte 1Parte 1,
p. 902-906,
2002.
Palavras-Chave:
ionization chambers;
calibration;
computerized tomography;
x-ray equipment;
energy dependence;
x radiation
MAIA, A.F.; CALDAS, L.V.E.
Calibracao de uma camara tipo lapis em feixes padroes de raios-X.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 4,
n. 3,
p. 902-906,
2002.
Parte 1Parte 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/5984. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SANTOS, W.S.
; NEVES, L.P.; PERINI, A.P.; BELINATO, W.; CALDAS, L.V.E.
; MAIA, A.F..
Cálculo de coeficientes de conversão de risco de câncer para exposições médicas e ocupacionais usando simulação de Monte Carlo em procedimentos cardíacos de radiologia intervencionista.
Brazilian Journal of Radiation Sciences,
v. 3,
n. 1A,
p. 1-11,
2015.
Palavras-Chave:
monte carlo method;
neoplasms;
phantoms;
radiological personnel;
x radiation;
radiation protection;
radiation transport;
radiation doses;
occupational exposure;
patients;
protective clothing;
risk assessment;
shielding materials
SANTOS, W.S.; NEVES, L.P.; PERINI, A.P.; BELINATO, W.; CALDAS, L.V.E.; MAIA, A.F.
Cálculo de coeficientes de conversão de risco de câncer para exposições médicas e ocupacionais usando simulação de Monte Carlo em procedimentos cardíacos de radiologia intervencionista.
Brazilian Journal of Radiation Sciences,
v. 3,
n. 1A,
p. 1-11,
2015.
Disponível em: http://repositorio.ipen.br/handle/123456789/25345. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
AFONSO, L.C.; VIVOLO, VITOR
; CALDAS, L.V.E.
.
Characteristics of a tandem system of ionization chambers in x-ray beams mammography level.
Applied Radiation and Isotopes,
v. 68,
p. 610-613,
2010.
Palavras-Chave:
ionization chambers;
calibration;
x radiation;
beams;
biomedical radiography;
mammary glands;
radiation detectors;
quality control
AFONSO, L.C.; VIVOLO, VITOR; CALDAS, L.V.E.
Characteristics of a tandem system of ionization chambers in x-ray beams mammography level.
Applied Radiation and Isotopes,
v. 68,
p. 610-613,
2010.
Disponível em: http://repositorio.ipen.br/handle/123456789/4736. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, NATALIA F. DA
; XAVIER, M.
; VIVOLO, V.
; CALDAS, L.V.E.
.
Characterization of a free air ionization chamber for low energy X-rays.
Journal of Physics: Conference Series,
v. 733,
p. 1-5,
2016.
DOI:
10.1088/1742-6596/733/1/012090
Abstract:
Free air ionization chambers are used by most primary metrology laboratories as
primary standards of the quantities air kerma and exposure in X-ray beams. The free air
ionization chamber for low energies of the Calibration Laboratory (LCI) of IPEN showed in a
characterization test a problem in the set responsible for the variation of its sensitive volume.
After a modification in the support of the micrometers used for the movement of the internal
cylinder and the establishment of a new alignment system protocol, the tests were redone. The
objective of this work was to present the results obtained in the new condition.
Palavras-Chave:
calibration;
ionization;
standards;
ionization chambers;
air;
alignment;
cylinders;
kerma;
modifications;
variations;
x radiation
SILVA, NATALIA F. DA; XAVIER, M.; VIVOLO, V.; CALDAS, L.V.E.
Characterization of a free air ionization chamber for low energy X-rays.
Journal of Physics: Conference Series,
v. 733,
p. 1-5,
2016.
DOI:
10.1088/1742-6596/733/1/012090.
Disponível em: http://repositorio.ipen.br/handle/123456789/27804. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ROCHA, F.D.G.; CALDAS, L.V.E.
.
Characterization of Al sub(2)Osub(3) sintered pellets for dosimetric applications in radiotherapy.
Journal of Radiological Protection,
v. 19,
n. 1,
p. 51-55,
1999.
DOI:
10.1088/0952-4746/19/1/006
Palavras-Chave:
aluminium oxides;
sintered materials;
thermoluminescence;
dosimetry;
radiotherapy;
cobalt 60;
gamma radiation;
x radiation;
glow curve;
energy dependence
ROCHA, F.D.G.; CALDAS, L.V.E.
Characterization of Al sub(2)Osub(3) sintered pellets for dosimetric applications in radiotherapy.
Journal of Radiological Protection,
v. 19,
n. 1,
p. 51-55,
1999.
DOI:
10.1088/0952-4746/19/1/006.
Disponível em: http://repositorio.ipen.br/handle/123456789/6331. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NEVES, LUCIO P.
; SILVA, ERIC A.B.
; PERINI, ANA P.
; MAIDANA, NORA L.; CALDAS, LINDA V.E.
.
Characterization of an extrapolation chamber for low-energy x-rays: Experimentakl and Monte Carlo preliminary results.
Applied Radiation and Isotopes,
v. 70,
n. 7,
p. 1388-1391,
2012.
Palavras-Chave:
extrapolation chambers;
energy dependence;
x radiation;
computerized simulation;
computer codes;
m codes;
monte carlo method
NEVES, LUCIO P.; SILVA, ERIC A.B.; PERINI, ANA P.; MAIDANA, NORA L.; CALDAS, LINDA V.E.
Characterization of an extrapolation chamber for low-energy x-rays: Experimentakl and Monte Carlo preliminary results.
Applied Radiation and Isotopes,
v. 70,
n. 7,
p. 1388-1391,
2012.
Disponível em: http://repositorio.ipen.br/handle/123456789/4220. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, ERIC A.B. da; CALDAS, LINDA V.E.
.
Characterization of an extrapolation chamber in X ray beams, diagnostic radiology level.
Radioproteção,
v. 2,
n. 20,
p. 83-90,
2012.
Palavras-Chave:
extrapolation chambers;
calibration standards;
radiation detectors;
x radiation;
radiation sources;
diagnostic techniques
SILVA, ERIC A.B. da; CALDAS, LINDA V.E.
Characterization of an extrapolation chamber in X ray beams, diagnostic radiology level.
Radioproteção,
v. 2,
n. 20,
p. 83-90,
2012.
Disponível em: http://repositorio.ipen.br/handle/123456789/4183. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
CASTANHO, S.R.H.M.
; MORENO, R..
Characterization of Sisub(3)Nsub(4) powders in aqueous dispersions.
Cerâmica,
v. 44,
n. 287/288,
p. 141-145,
1998.
DOI:
10.1590/S0366-69131998000400006
Palavras-Chave:
silicon nitrides;
powders;
slip casting;
dispersions;
surfaces;
chemical properties;
oxidation;
photoelectron spectroscopy;
x radiation;
transmission electron microscopy
CASTANHO, S.R.H.M.; MORENO, R.
Characterization of Sisub(3)Nsub(4) powders in aqueous dispersions.
Cerâmica,
v. 44,
n. 287/288,
p. 141-145,
1998.
DOI:
10.1590/S0366-69131998000400006.
Disponível em: http://repositorio.ipen.br/handle/123456789/6362. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
SILVA, J.O.; NONATO, F.B.C.; CALDAS, L.V.E.
.
Characterizations tests of a homemade ionization chamber in mammography standard radiation beams.
Radiation Physics and Chemistry,
v. 95,
p. 151-153,
2014.
Palavras-Chave:
biomedical radiography;
ionization chambers;
dosimetry;
calibration;
mammary glands;
x radiation
SILVA, J.O.; NONATO, F.B.C.; CALDAS, L.V.E.
Characterizations tests of a homemade ionization chamber in mammography standard radiation beams.
Radiation Physics and Chemistry,
v. 95,
p. 151-153,
2014.
Disponível em: http://repositorio.ipen.br/handle/123456789/3992. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MARTINS, JOAO F.T.; COSTA, FABIO E.
; SANTOS, ROBINSON A. dos; MESQUITA, CARLOS H. de
; HAMADA, MARGARIDA M.
.
A comparative study on the performance of radiation detectors from the HgIsub(2) crystals grown by different techniques.
Nukleonika,
v. 57,
n. 4,
p. 555-562,
2012.
Palavras-Chave:
chemical radiation detectors;
crystal growth methods;
gamma radiation;
hgi2 semiconductor detectors;
mercury iodides;
radiation detectors;
semiconductor detectors;
x radiation
MARTINS, JOAO F.T.; COSTA, FABIO E.; SANTOS, ROBINSON A. dos; MESQUITA, CARLOS H. de; HAMADA, MARGARIDA M.
A comparative study on the performance of radiation detectors from the HgIsub(2) crystals grown by different techniques.
Nukleonika,
v. 57,
n. 4,
p. 555-562,
2012.
Disponível em: http://repositorio.ipen.br/handle/123456789/4210. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
TEIXEIRA, BRUNA S.
; GARCIA, RAFAEL H.L.
; TAKINAMI, PATRICIA Y.I.
; DEL MASTRO, NELIDA L.
.
Comparison of gamma radiation effects on natural corn and potato starches and modified cassava starch.
Radiation Physics and Chemistry,
v. 142,
p. 44-49,
2018.
DOI:
10.1016/j.radphyschem.2017.09.001
Abstract:
The objective of this work was to evaluate the effect of irradiation treatment on physicochemical properties of three natural polymers, i.e. native potato and corn starches and a typical Brazilian product, cassava starch modified through fermentation-sour cassava- and also to prepare composite hydrocolloid films based on them. Starches were irradiated in a Co-60 irradiation chamber in doses up to 15 kGy, dose rate about 1 kGy/h. Differences were found in granule size distribution upon irradiation, mainly for corn and cassava starch but radiation did not cause significant changes in granule morphology. The viscosity of the potato, corn and cassava starches hydrogels decreased as a function of absorbed dose. Comparing non-irradiated and irradiated starches, changes in the Fourier transform infrared (FTIR) spectra in the 2000-1500 cm(-1) region for potato and corn starches were observed but not for the cassava starch. Maximum rupture force of the starch-based films was affected differently for each starch type; color analysis showed that doses of 15 kGy promoted a slight rise in the parameter b* (yellow color) while the parameter L* (lightness) was not significantly affected; X-ray diffraction patterns remained almost unchanged by irradiation.
Palavras-Chave:
starch;
cassava;
potatoes;
gamma radiation;
viscosity;
fourier transform spectrometers;
x-ray diffraction;
infrared spectrometers;
radiation effects;
absorbed radiation doses;
cobalt 60;
dose rates;
films;
irradiation;
visible radiation;
x radiation
TEIXEIRA, BRUNA S.; GARCIA, RAFAEL H.L.; TAKINAMI, PATRICIA Y.I.; DEL MASTRO, NELIDA L.
Comparison of gamma radiation effects on natural corn and potato starches and modified cassava starch.
Radiation Physics and Chemistry,
v. 142,
p. 44-49,
2018.
DOI:
10.1016/j.radphyschem.2017.09.001.
Disponível em: http://repositorio.ipen.br/handle/123456789/28857. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
OLIVEIRA, E.C.; CALDAS, L.V.E.
.
Comportamento de canetas dosimetricas em campos de radiacao gama e X de energias baixas.
Radiologia Brasileira,
v. 31,
p. 281-284,
1998.
Palavras-Chave:
dosimetry;
dosemeters;
gamma radiation;
x radiation;
radiation detectors;
performance;
energy dependence;
backscattering
OLIVEIRA, E.C.; CALDAS, L.V.E.
Comportamento de canetas dosimetricas em campos de radiacao gama e X de energias baixas.
Radiologia Brasileira,
v. 31,
p. 281-284,
1998.
Disponível em: http://repositorio.ipen.br/handle/123456789/6349. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
POTIENS, M.P.A.
; CALDAS, L.V.E.
.
Comportamento de monitores, nivel radiodiagnostico, em feixes padronizados de radiacao X.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 4,
n. 3,
Parte 1,
p. 958-960,
2002.
Palavras-Chave:
ionization chambers;
calibration;
energy dependence;
x radiation;
radiology;
diagnosis
POTIENS, M.P.A.; CALDAS, L.V.E.
Comportamento de monitores, nivel radiodiagnostico, em feixes padronizados de radiacao X.
Revista Brasileira de Pesquisa e Desenvolvimento,
v. 4,
n. 3,
p. 958-960,
2002.
Parte 1.
Disponível em: http://repositorio.ipen.br/handle/123456789/5977. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
-
Todo o repositório
-
Esta coleção
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o
significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo
será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.