Navegação Periódicos - Artigos por assunto "x-ray equipment"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 28319

    BATISTA, WILSON O.; SOARES, MARIA R. ; RIOS, JACQUELINE M.G.; SOUZA, ANTONIO C dos S.; PINHEIRO, ISABELLE M.; RAMIREZ, JOSE L.J.V.; CALDAS, LINDA V. E. . Assessment of scattered radiation from hand-held dental x-ray equipment using the Monte Carlo method. Journal of Radiological Protection, v. 41, n. 4, p. 654-668, 2021. DOI: 10.1088/1361-6498/abf3cd

    Abstract: The objective of the present study was to evaluate the intensity and spatial distribution of the scattered radiation caused by the use of hand-held x-ray equipment in the zone occupied by the operator, using the Monte Carlo simulation for radiographic views of the upper and lower incisor teeth, and the consequent evaluation of the equivalent dose in the lens. In order to carry out this evaluation, the geometry of a typical dental facility with plaster walls containing the scattering object was used for the computational scenario implemented for the Monte Carlo method simulation. The PENELOPE code for Monte Carlo simulation of electron and photon transport was used with the radiation beam represented by a 60 kV spectrum, 1.5 mm Al and tungsten target. The simulations were carried out with typical parameters for workload and the number of radiographs/week. The results showed that the exposure levels varied significantly according to the angle of the x-ray beam and with the distance to the scattering object. It is concluded that the incorporation of hand-held equipment in dental radiology must be accompanied by the surveillance of occupational exposure levels and a review of the training structure of professionals in dental radiology regarding aspects of radiological protection and the particularities of using this type of equipment.

    Palavras-Chave: dentistry; x-ray equipment; monte carlo method; oral cavity; biomedical radiography; scattering

  • IPEN-DOC 09360

    MAIA, A.F.; CALDAS, L.V.E. . Calibracao de uma camara tipo lapis em feixes padroes de raios-X. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1Parte 1, p. 902-906, 2002.

    Palavras-Chave: ionization chambers; calibration; computerized tomography; x-ray equipment; energy dependence; x radiation

  • IPEN-DOC 08651

    POTIENS, M.P.A. ; CALDAS, L.V.E. . Calibration of kVsub(p) meters used in quality control tests in diagnostic radiology by spectrometry. Radiation Protection Dosimetry, v. 98, n. 3, p. 343-346, 2002. DOI: 10.1093/oxfordjournals.rpd.a006726

    Palavras-Chave: x-ray equipment; quality control; calibration; spectroscopy; high-purity ge detectors; radiology; diagnostic techniques

  • IPEN-DOC 24817

    ICHIKAWA, RODRIGO U. ; ROCA, ALEJANDRO G.; LOPEZ-ORTEGA, ALBERTO; ESTRADER, MARTA; PERAL, INMA; TURRILLAS, XABIER; NOGUES, JOSEP. Combining X-Ray whole powder pattern modeling, rietveld and pair distribution function analyses as a novel bulk approach to study interfaces in heteronanostructures: oxidation front in FeO/Fe3O4 core/shell nanoparticles as a case study. Small, v. 14, n. 30, p. 1800804-1 - 1800804-11, 2018. DOI: 10.1002/smll.201800804

    Abstract: Understanding the microstructure in heterostructured nanoparticles is crucial to harnessing their properties. Although microscopy is ideal for this purpose, it allows for the analysis of only a few nanoparticles. Thus, there is a need for structural methods that take the whole sample into account. Here, a novel bulk‐approach based on the combined analysis of synchrotron X‐ray powder diffraction with whole powder pattern modeling, Rietveld and pair distribution function is presented. The microstructural temporal evolution of FeO/Fe3O4 core/shell nanocubes is studied at different time intervals. The results indicate that a two‐phase approach (FeO and Fe3O4) is not sufficient to successfully fit the data and two additional interface phases (FeO and Fe3O4) are needed to obtain satisfactory fits, i.e., an onion‐type structure. The analysis shows that the Fe3O4 phases grow to some extent (≈1 nm) at the expense of the FeO core. Moreover, the FeO core progressively changes its stoichiometry to accommodate more oxygen. The temporal evolution of the parameters indicates that the structure of the FeO/Fe3O4 nanocubes is rather stable, although the exact interface structure slightly evolves with time. This approach paves the way for average studies of interfaces in different kinds of heterostructured nanoparticles, particularly in cases where spectroscopic methods have some limitations.

    Palavras-Chave: iron oxides; nanoparticles; shells; oxidation; hybridization; x-ray equipment

  • IPEN-DOC 07049

    ROS, R.A.; CALDAS, L.V.E. . Controle de qualidade de medidores de tensao nao-invasivos em equipamento de raios X, nivel diagnostico. Radiologia Brasileira, v. 34, n. 2, p. 89-94, 2001. DOI: 10.1590/S0100-39842001000200007

    Palavras-Chave: x-ray equipment; x radiation; quality control; electric potential; electric measuring instruments; monitors; high-purity ge detectors; ionization chambers; diagnosis; radiology

  • IPEN-DOC 09365

    COSTA, A.M.; CALDAS, L.V.E. . Desempenho de uma camara de ionizacao especial para controle da qualidade em radioterapia. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1Parte 1, p. 941-945, 2002.

    Palavras-Chave: ionization chambers; x-ray equipment; x radiation; quality control; radiotherapy

  • IPEN-DOC 22508

    SANTOS, FELIPE A.; GALEANO, DIEGO C.; SANTOS, WILLIAM S. ; CARVALHO JUNIOR, ALBERICO B.. Evaluation of medical exposure and exposure by the public in a typical scenario of examinations using mobile X-ray equipment through the Monte Carlo simulation. Radiation Measurements, v. 89, p. 68-73, 2016.

    Palavras-Chave: evaluation; x-ray equipment; monte carlo method; conversion; doses; radiation doses; chest; abdomen

  • IPEN-DOC 26677

    CABRAL, EDUARDO L.L. ; SABUNDJIAN, GAIANE ; CONTI, THADEU das N. . Pixel-position-based lossless image compression algorithm. International Journal of Innovative Studies in Sciences and Engineering Technology, v. 5, n. 12, p. 21-30, 2019.

    Abstract: In this paper we present a novel lossless image compression method that is very simple and fast. The method uses linear prediction followed by arithmetic coding. Different prediction functions are used to estimate the intensity of image pixels. Two variants of the prediction algorithm are presented. One variant uses two different prediction functions and the other uses three different prediction functions. The position of the pixel in the image determines which prediction function is used. The method can be applied for images of any size and of high bit-depths. Standard images available in the literature are used to test the method. The compression ratios obtained with the proposed method are compared with the compression ratios obtained with the JPEG-LS and JPEG2000 methods and the results are satisfactory.

    Palavras-Chave: images; image processing; compression; algorithms; computer graphics; computer codes; image converters; standardization; tomography; x-ray equipment; ultrasonography; oil spills; biomedical radiography

  • IPEN-DOC 21263

    CORREA, EDUARDO ; MEDEIROS, REGINA; POTIENS, MARIA da P. ; VIVOLO, VITOR ; COSTA, NATHALIA ; MURATA, CAMILA; KIKUTI, CRISTINA. Preliminary tests of a kerma-area product (KAP) meter to be used as a monitor chamber in a conventional diagnostic X ray system. Journal of Modern Physics, v. 6, n. 4, p. 483-489, 2015. DOI: 10.4236/jmp.2015.64052

    Palavras-Chave: kerma; radiology; diagnostic uses; x-ray equipment; testing; ionization chambers; quality control

  • IPEN-DOC 08963

    COSTA, A.M.; CALDAS, L.V.E. . Response characteristics of a tandem ionization chamber in standard X-ray beams. Applied Radiation and Isotopes, v. 58, n. 4, p. 495-500, 2003.

    Palavras-Chave: ionization chambers; quality control; x-ray equipment; x radiation; calibration; performance

  • IPEN-DOC 27193

    SILVA, JAQUELINE S. da ; CARVALHO, SABRINA G.M. ; SILVA, RODRIGO P. da ; TAVARES, ANA C.; SCHADE, ULRICH; PUSKAR, LJILJANA; FONSECA, FABIO C. ; MATOS, BRUNO R. . SAXS signature of the lamellar ordering of ionic domains of perfluorinated sulfonic-acid ionomers by electric and magnetic field-assisted casting. Physical Chemistry Chemical Physics, v. 22, n. 24, p. 13764-13779, 2020. DOI: 10.1039/d0cp01864c

    Abstract: At present, small angle X-ray scattering (SAXS) studies of perfluorinated sulfonic-acid ionomers (PFSAs) are unable to fully determine the true shape of their building blocks, as recent SAXS modelling predicts disk- and rod-like nanoionic domains as being equally possible. This scenario requires evidence-based findings to unravel the real shape of PFSA building blocks. Herein, a SAXS pattern signature for a lamellar nanophase separation of the ionic domains of Nafion is presented, backed by mid and far infrared spectroscopy (MIR and FIR) and wide angle X-ray scattering (WAXS) data of Nafion in different ionic forms, a broad range of ionic phase contents (EW ~ 859–42 252 g eq-1) and temperatures. The study indicates that the lamellar arrangement of the ionic domains is the most representative morphology that accounts for the physical properties of this ionomer. The lamellar SAXS reflections of Nafion are enhanced in electric and magnetic field-aligned membranes, as confirmed by atomic force microscopy (AFM). Electric and magnetic field-assisted casting of Nafion allowed producing nanostructured and anisotropic films with the lamellas stacked perpendicularly to the field vector, which is the direction of interest for several applications. Such nanostructured Nafion membranes are bestowed with advanced optical and proton transport properties, making them promising materials for solar and fuel cells.

    Palavras-Chave: scattering; x-ray equipment; x-ray sources; proton exchange membrane fuel cells; polymers; fourier transform spectrometers; measuring instruments; atomic force microscopy; fuel cells

  • IPEN-DOC 09362

    PEREIRA, M.A.G.; BONIFACIO, D.A.B.; MACHADO, A.C.B.; KANASHIRO, F.Y.; HERDADE, S.B.; TERINI, R.A.; CALDAS, L.V.E. . Scattering fraction of X-rays incident on a phantom from the measured energy spectra. Revista Brasileira de Pesquisa e Desenvolvimento, v. 4, n. 3, Parte 1, p. 917-921, 2002.

    Palavras-Chave: x-ray spectroscopy; scattering; x radiation; dose equivalents; photodiodes; phantoms; energy spectra; x-ray equipment; diagnosis; radiology

  • IPEN-DOC 09031

    COSTA, A.M.; CALDAS, L.V.E. . A special ionisation chamber for quality control of diagnostic and mammography X ray equipment. Radiation Protection Dosimetry, v. 104, n. 1, p. 41-45, 2003.

    Palavras-Chave: ionization chambers; x-ray equipment; biomedical radiography; quality control; x radiation; diagnosis; nuclear medicine

  • IPEN-DOC 25835

    MURATA, CAMILA H.; HONDA, CRISTIANE J.C. ; LAVINIA, NICOLAS C.; CALDAS, LINDA V.E. ; MEDEIROS, REGINA B.. The performance of a prototype device designed to evaluate quality parameters of radiological equipment: complementary study. Radiation Physics and Chemistry, v. 159, p. 131-137, 2019. DOI: 10.1016/j.radphyschem.2019.02.034

    Abstract: Quality control measurements in radiological equipment are essential to verify their achievable performance standards, as average peak voltage (kVp), practical peak voltage (kVpp), exposure time, radiation dose and halfvalue layer (HVL). In a recent study, a multifunctional prototype's partial results were presented using a solidstate detector to evaluate quality parameters as kVp, exposure time and HVL of radiological equipment. In the present work, the accuracy of these measurements was improved, and dosimetric parameters were developed aiming to comply with normative requirements. The prototype board hardware was built with four sensors PIN RD100 A and a dedicated software based on their signals. In a single exposure, these signals were used in settled polynomial functions to determine kVp, kVpp, exposure time, radiation dose, dose rate and HVL. Characterization tests were undertaken at an instruments calibration laboratory and at a clinical research laboratory. A mathematical function was fitted for 50–120 kVp range, with R2 =0.999. This new algorithm allowed improving the kVp accuracy from [0.3–2.3%] to [0.03–1.5%]. The reproducibility and accuracy of the radiation dose rate reached 0.94% and 0.34%, respectively. The dose range measurements varied from 0.01 to 40 mGy. In addition, calibration tests were performed in calibration laboratory at standard traceable radiation qualities of RQR6 and RQR8. The total uncertainty associated with this calibration did not exceed 2%. In conclusion, the prototype can be considered a multifunctional non-invasive instrument appropriate to evaluate radiological equipment performance with an effective range from 50 kV to 120 kV.

    Palavras-Chave: radiology; equipment; quality control; performance; x-ray equipment; accuracy; photodiodes; comparative evaluations; quantum efficiency

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.