Navegação Teses por assunto "diagnostic techniques"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 06634

    COSTA, PAULO R. . Modelo para determinacao de espessuras de barreiras protetoras em salas para radiologia diagnostica. 1999. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 143 p. Orientador: Linda Viola Ehlin Caldas.

    Palavras-Chave: si semiconductor detectors; surface barrier detectors; calibration; radiology; thickness; radiation protection; computerized simulation; electron spin resonance; x radiation; diagnostic techniques

  • IPEN-DOC 27511

    BOAS, CRISTIAN A.W.V. . Obtenção de kit de PSMA-617 para pronta marcação com lutécio-177 e sua avaliação na aplicabilidade no tratamento do câncer de próstata / Evaluation of the applicability in prostate cancer of a ready-to-use kit of PSMA-617 for radiolabeled with lutetium-177 . 2020. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 209 p. Orientador: Elaine Bortoleti de Araújo. DOI: 10.11606/T.85.2020.tde-23122020-094716

    Abstract: O câncer de próstata é o segundo tipo de neoplasia que mais afeta homens no Brasil. De acordo com o Instituto Nacional de Câncer (INCA), em 2020 surgirão mais de 65 mil novos casos desta doença. Uma via eficiente para o tratamento deste câncer é a partir da produção de radiofármacos que se ligam especificamente ao antígeno de membrana prostático específico (PSMA), superexpresso nas células cancerígenas. Este trabalho estudou a radiomarcação do PSMA-617 com lutécio-177 de atividade específica distinta, em função da rota de produção (com ou sem carregador) e o efeito in vitro e in vivo nas propriedades do radiofármaco. Também foi estudado o escalonamento de lotes piloto de produção do PSMA-617-177Lu (sem carregador), que demonstrou a viabilidade na produção de lote contendo até 4 doses terapêuticas do PSMA-617-177Lu. O trabalho apresenta proposta de um kit para marcação, a partir do estudo da estabilidade de armazenamento dos constituintes da radiomarcação. A estabilidade das doses terapêuticas foi estabelecida por até 48 horas, mediante congelamento do produto, em embalado de transporte, que viabilizará o envio do radiofármaco para regiões distantes do local de produção. O estudo de saturação in vitro demonstrou que a maior atividade específica do radiofármaco resultou em valor de Kd (constante de dissociação) significativamente inferior. No ensaio de competição observou-se que, independentemente da atividade específica estudada, o bloqueio da ligação do PSMA-617-177Lu no PSMA expresso foi semelhante. No ensaio de internalização verificou-se porcentagens semelhantes, a despeito da atividade específica de marcação. Os perfis de clareamento sanguíneo foram semelhantes, assim como o perfil de biodistribuição não foi afetado em função da atividade específica de marcação do PSMA-617-177Lu. Contudo, observou-se um retardo na eliminação do PSMA-617-177Lu de órgãos viscerais não alvo (fígado, baço, pâncreas) na marcação com menor atividade específica. Este estudo atestou a estabilidade do PSMA-617-177Lu in vivo, pois não se observou incremento da captação óssea (177LuCl3 possuí tropismo por osso), para ambas as atividades especificas estudadas. Os ensaios com camundongos com tumor de próstata revelaram captação tumoral semelhante, independentemente da atividade específica, contudo observou-se melhor relação tumor/sangue, órgãos e tecidos de interesse com PSMA-617-177Lu com menor atividade específica. O estudo de bloqueio apresentou, para ambas as atividades específicas, redução expressiva na captação tumoral e renal dos radiofármacos. Concluiu-se que a variação da atividade específica de marcação do PSMA-617 não afetou a especificidade de ligação tumoral e a escolha do lutécio-177 (com ou sem carregador) poderá basear-se em fatores como a disponibilidade do radioisótopo e os custos de produção envolvidos.

    Palavras-Chave: lutetium 177; radiopharmaceuticals; prostate; neoplasms; antigen; cell membranes; tumor cells; uptake; carriers; radionuclide kinetics; biological availability; radioimmunodetection; scintiscanning; in vivo; in vitro; positron computed tomography; gamma radiation; alpha particles; beta decay radioisotopes; dosimetry; diagnostic techniques; diagnosis

  • IPEN-DOC 10890

    MAIA, ANA F. . Padronização de feixes e metodologia dosimétrica em tomografia computadorizada. 2005. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 181 p. Orientador: Linda Viola Ehlin Caldas.

    Palavras-Chave: beams; computerized tomography; dosimetry; image processing; ion-mobility detectors; ionization chambers; multiwire proportional chambers; quality assurance; diagnostic techniques; measuring instruments; processing; proportional counters; radiation detectors; tomography; standards

  • IPEN-DOC 27287

    SILVEIRA, SILVESTRE J.S. da . Perfil clínico e epidemiológico da Leishmaniose Tegumentar Americana no Hospital de Doenças Tropicais da Universidade Federal do Tocantins / Clinical and epidemiological profile of American Tegumentary Leishmaniasis at the Tropical Diseases Hospital of the Federal University of Tocantins . 2020. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 124 p. Orientador: Patrick Jack Spencer. DOI: 10.11606/D.85.2020.tde-21092020-145701

    Abstract: As lesões de pele e mucosas da Leishmaniose Tegumentar são indolores, o que retarda sua busca por tratamento, podendo sobrevir deformidades estigmatizantes. No Tocantins, flebotomíneas Lutzomyia sp transmitem principalmente a Leishmania braziliensis. Foram analisados os prontuários dos 331 pacientes notificados por LTA ao SINAN pelo HDT/UFT, no período de 2010 a 2016, objetivando apresentar seu perfil clínico-epidemiológico. Encontrando 92,14% de residentes no Tocantins, os 83,99% de casos autóctones corroboraram a endemicidade na região. Com 83,08% de moradores urbanos, a zona periurbana foi subestimada. As três faixas etárias mais prevalentes somaram dos 20 aos 49 anos, 51,65%, equivalente à idade predominante da população economicamente ativa. O sexo masculino predominou com 76,43%; as ocupações com atividades agro-pecuárias responderam pela metade dos casos; 13,90% como doenças ocupacionais. A forma cutânea ocorreu em 88,82%, a mucosa em 11,18%, e destas, 35,13% mostraram cicatrizes cutâneas. Coinfecção LTA-HIV foi confirmada em 1,81% dos casos. O critério clínico-laboratorial (94,26%) foi o mais utilizado para confirmar o diagnóstico: 75,83% dos pacientes realizaram o exame parasitológico direto por escarificação da lesão, com positividade de 83,66%. A terapêutica usada: 82,17% com meglumina e 13,60% com anfotericina B; falha terapêutica em 0,6% dos casos. Mas sucedeu-se evolução para cura em 95,47% dos casos notificados. O deslocamento populacional, por obras de impacto ambiental, como a usina hidrelétrica de Estreito-MA inaugurada em 2012, ou pelo próprio florescimento das cidades tocantinenses, avultando as zonas periurbanas, favoreceram a ocorrência de antropozoonoses como a LTA.

    Palavras-Chave: microorganisms; parasites; infectious diseases; animal tissues; skin; clinical trials; patients testing; radioimmunology; interferon; gamma radiation; epidemiology; therapy; diagnostic techniques; drugs; spatial distribution; time dependence; brazil

  • IPEN-DOC 26638

    MORAES, DAVI A. . Planta experimental para monitoração e diagnóstico de falhas utilizando inteligência artificial / Experimental plant for monitoring and fault diagnostic using artificial intelligence . 2019. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 162 p. Orientador: Iraci Martinez Pereira Gonçalves. DOI: 10.11606/T.85.2020.tde-03022020-110813

    Abstract: Neste trabalho foi desenvolvida uma planta experimental inspirada em um reator nuclear de potência do tipo PWR e posterior aplicação de Inteligência Artificial na Monitoração e Diagnóstico de Falhas, por meio dos métodos GMDH (Group Method of Data Handling) e RNA (Redes Neurais Artificiais). Com a planta experimental, tornou-se possível aplicar conceitos inovadores de modelagem de sistemas (Digital Twin) on line para a monitoração e diagnóstico de falhas individuais e/ou combinadas. Conclui-se que, embora ambos os sistemas de monitoração apresentaram resultados satisfatórios, o GMDH demonstrou um melhor desempenho em relação às Redes Neurais, pois além de apresentar valores de desvios médios menores do que o modelo utilizando Redes Neurais, foi possível realizar a monitoração de todas as variáveis, enquanto que utilizando Redes Neurais não foi possível monitorar as variáveis de potência do aquecedor, nível, e potência e vazões das bombas. A inserção de falhas em uma ou mais variáveis de temperatura, repercutiu na estimativa da rede para as demais variáveis, porém não impediu que o Sistema de Monitoração identificasse a falha. Para determinar o comportamento do Sistema de Monitoração com falhas múltiplas, foram aplicadas falhas simultâneas nos sensores de temperatura.

    Palavras-Chave: variational methods; mathematical models; numerical solution; artificial intelligence; genetic algorithms; neural networks; computerized simulation; system failure analysis; sensors; temperature distribution; medicinal plants; diagnosis; diagnostic techniques; diagnostic uses

  • IPEN-DOC 05328

    DIAS, LIGIA E.M.F. . Producao de prolactina humana autentica por tecnicas de DNA recombinante. 1993. Tese (Doutoramento) - Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP, Sao Paulo. 90 p. Orientador: Paolo Bartolini.

    Palavras-Chave: lth; production; recombinant dna; radioimmunoassay; hormones; escherichia coli; diagnostic techniques; sth; proteins; plasmids

  • IPEN-DOC 28055

    PRADO, MARILIZA C. de O. . Thermal damage and time of excision of micro and super pulsed diode lasers : an ex-vivo comparative study / Dano térmico e tempo de excisão dos lasers de diodo micro e superpulsado: um estudo comparativo ex-vivo . 2021. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 138 p. Orientador: Denise Maria Zezell. DOI: 10.11606/T.85.2021.tde-08092021-150518

    Abstract: Diode lasers are portable, accessible, efficient and reliable surgical units for performing surgeries and soft tissue biopsies of the oral cavity. The newer units are equipped with micro and super pulsed technologies and systems that allow the selection of different usage parameters in terms of emission mode, duty cycle, power and pulse duration. It is, however, not known which parameters or types of diode lasers produce the most intact tissue samples in the best possible surgical time. The main objective of this ex vivo study was to compare the thermal damage and the excision time of different parameters of the micro pulsed diode laser and the super pulsed diode laser. The secondary objectives were: 1) to provide practical recommendations for performing surgical excisions with diode lasers; 2) to examine possible correlations between the area and the depth of the thermal damage, as well as between the time of excision and the thermal damage. Ten groups of ten swine tongue specimens were excised (8 mm in diameter) using a surgical blade (control group: G1); micro pulsed diode laser in different emission modes, duty cycles, average power, peak power and pulse duration (G2 - 9); and the new super pulsed diode laser (G10) with the smallest single parameter recommended by the manufacturer (average power = 3.2W, peak power = 80 W, pulse duration from 10 μs to 100 ms). The wavelength of both was 940 nm. All parameters were previously measured with the power meter and activated disposable tips were discarded right after each biopsy. The area and the histological depth of the thermal damage were quantified using the NIS-Element Basic Research software (Nikon Instruments Inc), while the excision time was measured between the clamping until the total excision of the lesion. Kruskal-Wallis and Dunn's multiple comparison tests with Bonferroni correction were applied to compare the area and depth of thermal damage, as well as the time of excision between the groups. Correlations between area and depth of thermal damage and between excision time and thermal damage were examined using Spearman's nonparametric correlation coefficient. The level of significance was set at 5%. In the experimental groups (G2 - G10), the total area of thermal damage observed was smaller in the G3 group (continuous mode, average power = 1.5W; median = 0.91 mm2 ; p = 0.009). All other groups had thermal damage areas larger than 1 mm2 with G7 (pulsed mode, duty cycle = 33%, average power = 1.5W, peak = 5.4W and pulse duration of 100 μs) and G9 (pulsed mode, duty cycle = 50%, average power = 1.5W, peak = 3.6W and pulse duration = 1 ms) producing the largest damage areas (median 1.93 and 1.97 mm2 , respectively). In the multiple comparison, controlling the level of global significance, G3 presented a median area of thermal damage significantly smaller than those of G7 (p = 0.013) and G9 (p = 0.036). There were no statistically significant differences in the depth of thermal damage between the groups (p = 0.12). The median excision times of G1 (scalpel) and G10 (super pulsed) were significantly shorter than those found in the micro pulsed diode laser groups (G1 = 50; G10 = 69; G2 to G9 ranged from 142 to 238 seconds; p < 0.001). There was a direct correlation between the depth and area of thermal damage, but no correlation was found between the excision time and thermal damage. The use of the micro pulsed diode laser in continuous mode with average power = 1.5 W produced biopsies with the smallest area of thermal damage and greater tissue integrity, while the use of the super pulsed diode laser (average power = 3.2W, peak power = 80W, pulse duration from 10 μs to 100 ms) allowed faster excisions. Area and depth of thermal damage correlated directly. In clinical practice, the micro pulsed diode laser should be considered in continuous mode, at 1.5 W output power with 1.8 W peak power as the best option when aiming to achieve maximum tissue integrity. Whereas the use of super pulsed diode laser with output power = 3.2W, peak power = 80W, pulse duration from 10 μs to 100 ms, produced the best relationship between thermal damage and excision time, and is recommended when practical necessity requires rapid excisions with reasonable tissue integrity. The use of micro pulsed diode laser in pulsed emission mode with high peak power and long pulse duration should be avoided when performing oral biopsies so that tissue integrity is not compromised and hinders the histopathological analysis of the lesions.

    Palavras-Chave: diode-pumped solid state lasers; thermionic diodes; semiconductor diodes; electromagnetic pulses; internal electromagnetic pulses; pulse techniques; excision repair; animal tissues; oral cavity; damage; diagnostic techniques; biopsy; temperature dependence; thermal efficiency; penetration depth; depth dose distributions; optical depth curve; histological techniques; optical microscopy

  • IPEN-DOC 25696

    TEIXEIRA, LUCIA R. de A.C. . Tomografia por coerência óptica para avaliação de lesões vasculares na face e cavidade oral / Optical coherence tomography for the evaluation of vascular lesions in the face and oral cavity . 2017. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 103 p. Orientador: Denise Maria Zezell. DOI: 10.11606/T.85.2019.tde-30042019-101834

    Abstract: As lesões vasculares estão entre as anormalidades congênitas e neonatais mais comuns. Cerca de 60% estão localizadas na região da cabeça e pescoço. A identificação e a classificação adequadas de cada tipo de lesão, tem um impacto direto no diagnóstico e, no tratamento destes pacientes. A técnica de Tomografia por Coerência Óptica (Optical coherence tomography: OCT) obtém imagens em alta resolução, geradas em tempo real que permitem visualizar de forma não invasiva, estruturas celulares e extracelulares, com uma resolução espacial da ordem de 10μm, que é 20 vezes maior que a de um ultrassom, aproximando-se do nível histológico convencional, razão pela qual é considerada biópsia óptica. Com o objetivo de fornecer imagens que possibilitassem avaliar as diferenças na arquitetura dos vasos em diferentes tipos de lesões localizadas, no tecido cutâneo e na mucosa, em regiões da cabeça e pescoço, foram tomadas imagens de lesões de 27 pacientes usando um sistema de OCT com Doppler (1325nm). Os resultados deste estudo clínico comprovaram a viabilidade da OCT permitindo distinguir entre a pele normal e a pele com lesão. Na má-formação capilar, os vasos sanguíneos tiveram diâmetro médio de 114\μm ± 92μm e apresentaram uma profundidade média de 304 μm ± 99 μm. Os hemangiomas apresentaram vasos sanguíneos com diâmetro médio de 39μm ± 19 μm e profundidade média de 298 μm ± 133 μm. Nas lesões diagnosticadas pelo clínico como Hemangioma da mucosa labial, medimos diâmetro médio dos vasos de 45μm ± 16 μm com profundidade média de 520,5μm ± 189,5μm. Na má-formação linfática de lábio, os vasos sanguíneos apresentaram diâmetro médio de 157,5μm ± 90μm e, uma profundidade média 695μm ± 136μm. Na má-formação vascular de lábio, os vasos sanguíneos apresentaram diâmetro médio de 128μm±63μm e, uma profundidade média 689 μm ± 217μm. Com estas informações obtidas das imagens de OCT indicando fluxo, foi possível avaliar diferenças peculiares da lesão de cada paciente, promovendo o diagnóstico diferencial das lesões vasculares da superfície tecidual da pele e mucosa oral.

    Palavras-Chave: face; oral cavity; vascular diseases; angiomas; carcinomas; evaluation; control; tomography; optical systems; coherence length; doppler effect lasers; infrared radiation; diagnostic techniques

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.