Navegação Teses por assunto "optical depth curve"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 28028

    FONTES, ERIC H. . Estudo experimental e teórico da oxidação eletroquímica do etanol em meio alcalino por eletrocatalisadores core-shell Au@Pd/C e Pd/C / Experimental and theoretical studies of ethanol oxidation in alkaline medium by core-shell Au@Pd/C and Pd/C . 2021. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 183 p. Orientador: Almir Oliveira Neto. DOI: 10.11606/T.85.2021.tde-14072021-154529

    Abstract: O aumento na atividade catalítica da oxidação do etanol trará benefícios na performance de Células a Combustível Direta a Álcool, mas para que isso ocorra, a clivagem da ligação C-C associada aos processos de desidrogenação do etanol se faze necessário. Existe ainda uma lacuna no desenvolvimento de eletrocatalisadores que possuem essa habilidade, no entanto, as nanopartículas do tipo core-shell são fortes candidatas a promover novas propriedades eletrônicas que facilitam essa clivagem. A técnica de Espectroscopia Raman permitiu observar efeitos físicos característicos de nanopartículas de Au@Pd, e, juntamente com a DFT possibilitou identificar ligações híbridas Pd-C para Pd/C. A técnica de DRX permitiu observar a presença da estrutura cristalina dos eletrocatalisadores, no entanto, não foi possível observar variações nos parâmetros de rede. As técnicas TEM e STEM possibilitaram identifcar dispersões e deposições das nanopartículas metálicas sobre o suporte de carbono. As técnicas de STEM, Nano-ESD e core level XPS reveleram a presença da estrutura core-shell Au@Pd suportada em Carbono e que posteriormente foi comprovada por um método desenvolvido nesta tese. Além disso, as técnicas core level XPS e Nano-EDS revelaram respectivamente uma espessura do shell de 2,74 nm e 2,56 nm o que corresponde a uma espessura de 12 ML. Já a técnica de core level XPS para Au@Pd/C, revelou também uma homogeneidade na distribuição da composição ao longo da superfície, enquanto que diferentes estados de oxidação do Au não foram observados. Já a composição atômica ao longo da superfície do eletrocatalisador Pd/C variou em cerca de 30% relativo ao próprio material. A técnica de depth profiling XPS permitiu obter informações sobre a composição e os estados de oxidação ex situ em função da profundidade dos eletrodos, enquanto que a técnica de XPS de banda de valência permitiu obter informações experimentais da densidade de estados dos eletrocatalisadores e compará-los com as densidades de estados obtidos por DFT. Os resultados eletroquímicos foram promissores para o eletrocatalisador Au@Pd/C devido à elevada produção de dióxido de carbono. A produção de dióxido de carbono foi favorecida nos ânodos à base de Au e Pd devido a estabilidade da espécie CO, menor ativação para a clivagem da ligação C-C e menor Δ Greação (via DFT). Os resultados de DFT e VBXPS foram contrários ao previsto pela Teoria do centro da banda-d, no entanto, foram condizentes com o modelo de Anderson-Newns-Grimley. Além disso, o modelo ANG (englobando a descritor εμ) descreveu corretamente a interação metal - metal e metal - adsorbatos. Por Fim, o mecanismo de oxidação do etanol em meio alcalino foi incompleto, paralelo e com uma predominância de espécies C1 para os eletrocatalisadores Au@Pd/C.

    Palavras-Chave: alcohol fuel cells; direct ethanol fuel cells; direct methanol fuel cells; palladium complexes; catalyst supports; carbon; electrocatalysts; electrochemistry; fourier analysis; fourier transform spectrometers; fourier transformation; x-ray diffraction; optical depth curve; x-ray spectrometers; photon emission; scanning electron microscopy; transmission electron microscopy; transmission electron microscopy; electrodes; oxidation; field theories

  • IPEN-DOC 27277

    SILVA, MARCONES C.B. da . Metodologia para medida de foco de imageamento de escoamento bifásico utilizando técnicas de processamento inteligente / Methodology for measuring focus of two-phse flow imaging using intelligent processing techniques . 2020. Dissertação (Mestrado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 118 p. Orientador: Roberto Navarro de Mesquita. DOI: 10.11606/D.85.2020.tde-18092020-145342

    Abstract: Uma das necessidades comuns em parcela significativa das aplicações cientificas que utilizam imagens, é a avaliação objetiva da qualidade com base no nível de nitidez. Utilizando imagens capturadas experimentalmente sob condições de aquisição semelhantes a experimentos de escoamento bifásico em um Circuito de Circulação Natural (CCN) do Centro de Engenharia Nuclear (CEN) do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN / SP), foi desenvolvida uma metodologia para avaliação de nitidez de região de interesse (ROI) baseada em inferência fuzzy entre diferentes métricas de foco de baixa complexidade computacional, utilizando uma ferramenta de aquisição e processamento de imagens denominada FFE. Experimentos que utilizaram um padrão de foco na aquisição, demonstraram a utilidade do FFE para avaliar calibrações e ajustes de profundidade de campo estimadas entre 4 a 10 mm, permitindo um melhor ajuste do ponto máximo de foco em regiões de interesse (ROI) nos circuitos experimentais de escoamento, levando em consideração variações de distância de aquisição e condições de refração. Com a aplicação da metodologia é possível parametrizar, numericamente, a profundidade de campo (DOF) em experimentos que utilizam o foco de objetos de interesse como parâmetro para segmentação de imagens. A metodologia mostrou-se eficiente na calibração dos parâmetros de aquisição de imagens em condições variáveis de escoamento bifásico. Este trabalho demonstrou a eficácia de uma nova metodologia de estudo de métricas de foco que possibilitará desenvolvimento de novas técnicas e métricas de avaliação da qualidade de imagens que possam ser aplicadas em experimentos científicos.

    Palavras-Chave: natural convection; fuzzy logic; optical depth curve; counting techniques; metrics; calibration; image processing; optical properties; brightness; compressible flow; flow visualization; scientific personnel; quality control; computer codes; programming; computerized simulation

  • IPEN-DOC 28055

    PRADO, MARILIZA C. de O. . Thermal damage and time of excision of micro and super pulsed diode lasers : an ex-vivo comparative study / Dano térmico e tempo de excisão dos lasers de diodo micro e superpulsado: um estudo comparativo ex-vivo . 2021. Tese (Doutorado em Tecnologia Nuclear) - Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, São Paulo. 138 p. Orientador: Denise Maria Zezell. DOI: 10.11606/T.85.2021.tde-08092021-150518

    Abstract: Diode lasers are portable, accessible, efficient and reliable surgical units for performing surgeries and soft tissue biopsies of the oral cavity. The newer units are equipped with micro and super pulsed technologies and systems that allow the selection of different usage parameters in terms of emission mode, duty cycle, power and pulse duration. It is, however, not known which parameters or types of diode lasers produce the most intact tissue samples in the best possible surgical time. The main objective of this ex vivo study was to compare the thermal damage and the excision time of different parameters of the micro pulsed diode laser and the super pulsed diode laser. The secondary objectives were: 1) to provide practical recommendations for performing surgical excisions with diode lasers; 2) to examine possible correlations between the area and the depth of the thermal damage, as well as between the time of excision and the thermal damage. Ten groups of ten swine tongue specimens were excised (8 mm in diameter) using a surgical blade (control group: G1); micro pulsed diode laser in different emission modes, duty cycles, average power, peak power and pulse duration (G2 - 9); and the new super pulsed diode laser (G10) with the smallest single parameter recommended by the manufacturer (average power = 3.2W, peak power = 80 W, pulse duration from 10 μs to 100 ms). The wavelength of both was 940 nm. All parameters were previously measured with the power meter and activated disposable tips were discarded right after each biopsy. The area and the histological depth of the thermal damage were quantified using the NIS-Element Basic Research software (Nikon Instruments Inc), while the excision time was measured between the clamping until the total excision of the lesion. Kruskal-Wallis and Dunn's multiple comparison tests with Bonferroni correction were applied to compare the area and depth of thermal damage, as well as the time of excision between the groups. Correlations between area and depth of thermal damage and between excision time and thermal damage were examined using Spearman's nonparametric correlation coefficient. The level of significance was set at 5%. In the experimental groups (G2 - G10), the total area of thermal damage observed was smaller in the G3 group (continuous mode, average power = 1.5W; median = 0.91 mm2 ; p = 0.009). All other groups had thermal damage areas larger than 1 mm2 with G7 (pulsed mode, duty cycle = 33%, average power = 1.5W, peak = 5.4W and pulse duration of 100 μs) and G9 (pulsed mode, duty cycle = 50%, average power = 1.5W, peak = 3.6W and pulse duration = 1 ms) producing the largest damage areas (median 1.93 and 1.97 mm2 , respectively). In the multiple comparison, controlling the level of global significance, G3 presented a median area of thermal damage significantly smaller than those of G7 (p = 0.013) and G9 (p = 0.036). There were no statistically significant differences in the depth of thermal damage between the groups (p = 0.12). The median excision times of G1 (scalpel) and G10 (super pulsed) were significantly shorter than those found in the micro pulsed diode laser groups (G1 = 50; G10 = 69; G2 to G9 ranged from 142 to 238 seconds; p < 0.001). There was a direct correlation between the depth and area of thermal damage, but no correlation was found between the excision time and thermal damage. The use of the micro pulsed diode laser in continuous mode with average power = 1.5 W produced biopsies with the smallest area of thermal damage and greater tissue integrity, while the use of the super pulsed diode laser (average power = 3.2W, peak power = 80W, pulse duration from 10 μs to 100 ms) allowed faster excisions. Area and depth of thermal damage correlated directly. In clinical practice, the micro pulsed diode laser should be considered in continuous mode, at 1.5 W output power with 1.8 W peak power as the best option when aiming to achieve maximum tissue integrity. Whereas the use of super pulsed diode laser with output power = 3.2W, peak power = 80W, pulse duration from 10 μs to 100 ms, produced the best relationship between thermal damage and excision time, and is recommended when practical necessity requires rapid excisions with reasonable tissue integrity. The use of micro pulsed diode laser in pulsed emission mode with high peak power and long pulse duration should be avoided when performing oral biopsies so that tissue integrity is not compromised and hinders the histopathological analysis of the lesions.

    Palavras-Chave: diode-pumped solid state lasers; thermionic diodes; semiconductor diodes; electromagnetic pulses; internal electromagnetic pulses; pulse techniques; excision repair; animal tissues; oral cavity; damage; diagnostic techniques; biopsy; temperature dependence; thermal efficiency; penetration depth; depth dose distributions; optical depth curve; histological techniques; optical microscopy

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.