Navegação Eventos - Artigos por autor "RAELE, MARCUS P."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 12694

    GENEZINI, FREDERICO A. ; ZAHN, GUILHERME S. ; RAELE, MARCUS P. ; ZAMBONI, CIBELE B. ; CRUZ, MANOEL T.F. da. Analysis of multi-parametric coincidence measurements with n detectors. In: REUNIAO DE TRABALHO SOBRE FISICA NUCLEAR NO BRASIL, 28., 7-11 de setembro, 2005, Guaruja, SP. Anais... 2005. p. 373-378.

    Palavras-Chave: neutron detectors; multi-parameter analysis; coincidence methods; gamma detection

  • IPEN-DOC 24968

    RAELE, MARCUS P. ; SAMAD, RICARDO E. ; FREITAS, ANDERSON Z. ; PRETTO, LUCAS de ; AMARAL, MARCELLO M.; VIEIRA JUNIOR, NILSON D. ; WETTER, NIKLAUS U. . Backscattered light properties during femtosecond laser ablation and development of a dynamic interferometric focusing system. In: KAIERLE, STEFAN (Ed.); HEINEMANN, STEFAN W. (Ed.) HIGH-POWER LASER MATERIALS PROCESSING: APPLICATIONS, DIAGNOSTICS, AND SYSTEMS, 7th, January 27 - February 01, 2018, San Francisco, California, USA. Proceedings... Bellingham, WA, USA: Society of Photo-optical Instrumentation Engineers, 2018. p. 105250H-1 - 105250H-9. (SPIE Proceedings Series, 10525). DOI: 10.1117/12.2285899

    Abstract: The backscattered light originated when machining with femtosecond laser pulses can be used to accurately measure the processed surface position through an interferometer, as recently demonstrated by our group, in a setup that uses the same laser beam for ablation and inspection. The present work explores the characteristics of the laser light reflected by the target and its interaction with the resulting plasma to better understand its propagation physics and to improve the dynamic focusing system. The origin of this returning radiation was studied and has been traced, mainly, from the peripheral area of the focal spot (doughnut-like). By means of a Mach-Zehnder setup, the interferometric pattern was measured and analyzed aiming to access the influences of the plasma on the laser beam properties, and therefore on the retrieved information. Finally, the wavefront of the laser that creates and propagates through the plasma was characterized using a Shack-Hartmann sensor.

    Palavras-Chave: interferometry; lasers; ablation; plasma; backscattering; sensors; measuring instruments; laser beam machining; wavelengths

  • IPEN-DOC 21130

    COSTA, PRISCILA ; RAELE, MARCUS P. ; YORIYAZ, HELIO ; SIQUEIRA, PAULO de T.D. ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Boron film thickness determination to develop a low cost neutron using Monte Carlo Method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: boron; thin films; monte carlo method; neutron flux; neutron detection; alpha particles; thermal neutrons; charged particles; computerized simulation; photodiodes; silicon; thickness

  • IPEN-DOC 19129

    PIERETTI, EURICO F.; LEIVAS, TOMAZ P.; MAXIMO, ARTHUR; RAELE, MARCUS P. ; ROSSI, WAGNER de ; NEVES, MAURICIO D.M. das . Caracterização do efeito da gravação a laser na superfície do aço inoxidável austenitico ABNT NBR ISO 5832-1, utilizando implantes ortopédicos. In: CONGRESSO INTERNACIONAL ANUAL DA ABM, 68th, July 30 - August 2, 2013, Belo Horizonte, MG. Proceedings... 2013.

    Palavras-Chave: stainless steels; biological materials; roughness; laser beam machining; prostheses

  • IPEN-DOC 23822

    RAELE, MARCUS P. ; PRETTO, LUCAS R. de ; SAMAD, RICARDO E. ; FREITAS, ANDERSON Z. de ; ROSSI, WAGNER de ; VIEIRA JUNIOR, NILSON D. ; WETTER, NIKLAUS U. . Development of a dynamic interferometric focusing system for femtosecond laser machining. In: HEISTERKAMP, ALEXANDER (Ed.); HERMAN, PETER R. (Ed.); MEUNIER, MICHEL (Ed.); OSELLAME, ROBERTO (Ed.) FRONTIERS IN ULTRAFAST OPTICS: BIOMEDICAL, SCIENTIFIC, AND INDUSTRIAL APPLICATIONS, 18th, January 28, 2017, San Francisco, California, United States. Proceedings... Bellingham, Washington USA: Society of Photo-optical Instrumentation Engineers, 2017. p. 100940N-1 - 100940N-13. (SPIE Proceedings Series, 10094).

    Abstract: Taking advantage of the inherent characteristics of femtosecond laser used for machining, we developed an interferometric system able to evaluate and correct the focal position with an accuracy of a few microns, implementing a technique based on low coherence interferometry. This approach measures at the exact spot that the laser is machining, in real time, and is sensitive to any sample that acts as a scatterer to the wavelength in use. The experimental evaluation was divided in two steps: in the first a system based on a superluminescent LED was mounted to check the viability and develop the controlling software; in the second part a setup was mounted employing a femtosecond laser, and several kinds of samples using the active focus control, among which the results obtained with glass sample and a bovine tooth are meticulously described in this paper. The system was able to improve the performance in both samples, keeping them in the confocal region for an extended positioning range, resulting in better engraving by the laser.

    Palavras-Chave: laser beam machining; lasers; interferometry; laser radiation; ablation; michelson interferometer; cattle; teeth; bone tissues

  • IPEN-DOC 19240

    GUIMARAES, RENATO da S.; RAELE, MARCUS P. ; POTIENS JUNIOR, ADEMAR J. . Development of a sampler to caracterize radioactive materials. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: radioactive materials; radioactive wastes; samplers; neodymium lasers; decontamination

  • IPEN-DOC 18937

    COUCEIRO, IAKYRA B.; SILVA, THIAGO F. da; TARELHO, LUIZ V.G.; AZEREDO, CARLOS L.S.; MALINOVSKI, IGOR; GRIENEISEN, HANS P.H.; BARROS, WELLINGTON S.; FARIA, GIANCARLO V.; WEID, JEAN P. VON DER; AMARAL, MARCELLO M. ; RAELE, MARCUS P. ; FREITAS, ANDERSON Z. de . Development of traceability methodology for optical coherence tomography (OCT) using step height standard as calibration reference. In: LEHMANN, PETER H. (Ed.); OSTEN, WOLFGANG (Ed.); GASTINGER, KAY (Ed.) OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION, VII, May 23-26, Munich, Germany. Proceedings... Bellingham, Washington: Society of Photho-optical Instrumentation Engineers, 2011. p. 80822P-1 - 80822P-10. DOI: 10.1117/12.889404

    Palavras-Chave: coherent radiation; interferometry; calibration standards; tomography; optical models

  • IPEN-DOC 24157

    COSTA, PRISCILA ; COSTA, FABIO E. ; RAELE, MARCUS P. ; ZAHN, GUILHERME S. ; GERALDO, BIANCA ; VIEIRA JUNIOR, NILSON D. ; SAMAD, RICARDO E. ; GENEZINI, FREDERICO A. . Eletronic response of a photodiode coupled to a boron thin film. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: A portable thermal neutron detector is proposed in this work using a silicon photodiode coupled to a boron thin film. The aim of this work was to verify the effect in the electronic response of this specific photodiode due to boron deposition, since the direct deposition of boron in the semiconductor surface could affect its electrical properties specifically the p-type layer that affects directly the depletion region of the semiconductor reducing the neutron detector efficiency count. Three boron depositions with different thickness were performed in the photodiode (S3590-09) surface by pulsed laser deposition and the photodiode was characterized, before and after the deposition process, using a radioactive americium source. Energy spectra were used to verify the electronic response of the photodiode, due to the fact that it is possible to relate it to the photopeak pulse height and resolution. Spectra from the photodiode without and with boron film deposition were compared and a standard photodiode (S3590-04) that had the electronic signal conserved was used as reference to the pulse height for electronics adjustments. The photopeak energy resolution for the photodiode without boron layer was 10.26%. For the photodiode with boron deposition at different thicknesses, the resolution was: 7.64 % (0.14 μm), 7.30 % (0.44 μm) and 6.80 % (0.63 μm). From these results it is possible to evaluate that there was not any degradation in the silicon photodiode.

    Palavras-Chave: americium 241; boron; electrical properties; energy spectra; brazilian cnen; neutron detectors; photodiodes; portable equipment; thermal neutrons; thin films

  • IPEN-DOC 20913

    RAELE, MARCUS P. ; PRETTO, LUCAS R. de ; FREITAS, ANDERSON Z. de . Enhance resolution on OCT profilometry measurements using harmonic artifacts. In: FUJIMOTO, JAMES G. (Ed.); IZZATT, JOSEPH A. (Ed.); TUCHIN, VALERY V. (Ed.) OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE, 19th, February 7, 2015, San Francisco, California, United States. Proceedings... Society of Photho-optical Instrumentation Engineers, 2015. p. 93123Q-1 - 93123Q-8. (SPIE Proceedings Series, 9312).

    Palavras-Chave: coherent radiation; interferometry; harmonics; resolution; images; fourier transformation; tomography; optical models

  • IPEN-DOC 24814

    COSTA, PRISCILA ; RAELE, MARCUS P. ; SAMAD, RICARDO E. ; MACHADO, NOE G.P. ; VIEIRA JUNIOR, NILSON D. ; GENEZINI, FREDERICO A. . Femtosecond pulsed laser deposition of a boron thin film aiming at the development of a low-cost neutron detector. In: KAIERLE, STEFAN (Ed.); HEINEMANN, STEFAN W. (Ed.) HIGH-POWER LASER MATERIALS PROCESSING: APPLICATIONS, DIAGNOSTICS, AND SYSTEMS, 7th, January 27 - February 01, 2018, San Francisco, California, USA. Proceedings... Bellingham, WA, USA: Society of Photo-optical Instrumentation Engineers, 2018. p. 105250J-1 - 105250J-7. (SPIE Proceedings Series, 10525). DOI: 10.1117/12.2285896

    Abstract: Boron thin films were produced using femtosecond pulsed laser deposition aiming at the development of a neutron detector. As neutrons have no charge, in order to detect this particle converter materials are applied, promoting nuclear reactions that result in the emission of charged particles, allowing the neutrons presence to be indirectly inferred. Among the possible conversion materials, 10B has a considerable cross section for thermal neutrons and accessible cost. Furthermore, the nuclear reaction produces easily detectable alpha particles, making it a rational option to develop a low cost and portable neutron detector. The boron ablation threshold fluence has been measured by the Diagonal Scan (Dscan) technique that resulted in the minimum laser energy value of 17.7 (6) μJ and fluence of 5.63(19) J/cm2. Boron deposition was performed varying the pulse energy and deposition duration. The growth rate, morphological and physical aspects of the boron pulsed laser deposition were characterized by a Scanning Electron Microscope and an optical profilometer. The films surfaces have a flaky aspect with eventual droplets which had decayed overtime to a more smooth surface. The studied parameters allowed producing a boron coating with the optimal thickness in order to minimize self-absorption effect in the film, thus increasing efficiency.

    Palavras-Chave: laser radiation; neutron detectors; boron; thin films; lasers; ablation; scanning electron microscopy; thickness; deposition

  • IPEN-DOC 14647

    KATO, ILKA T.; MENDES, FAUSTO M.; ZEZELL, D.M. ; FREITAS, ANDERSON Z. de ; RAELE, MARCUS P. ; WETTER, NIKLAUS U. . Inhibition of enamel remineralization with blue LED: an in vitro study. In: SPIE PHOTONICS WEST 2009 - BIOS, January 24-29, 2009, Sao Francisco, USA. Proceedings... 2009.

    Palavras-Chave: light emitting diodes; enamels; caries; demineralization; fluorides; animal tissues; interactions; microhardness

  • IPEN-DOC 18510

    POTIENS JUNIOR, ADEMAR J. ; DELLAMANO, JOSE C. ; VICENTE, ROBERTO ; WETTER, NIKLAUS U. ; LANDULFO, EDUARDO ; RAELE, MARCUS P. . Laser decontamination of the radioactive lightning rods. In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 12th, October 7-12, 2012, Rio de Janeiro, RJ. Proceedings... 2012.

    Palavras-Chave: radioactivity; lightning; rods; americium 241; radioactive wastes; decontamination; laser radiation; ablation

  • IPEN-DOC 14127

    AMARAL, MARCELLO M.; RAELE, MARCUS P. ; FREITAS, ANDERSON Z. de ; ZAHN, GUILHERME S. ; SAMAD, RICARDO E. ; VIEIRA JUNIOR, NILSON D. ; TARELHO, LUIZ V.G. . Laser induced breakdown spectroscopy (LIBS) applied to stratigrafic elemental analysis and optical coherence tomography (OCT) to damage determination of cultural heritage brazilian coins. In: SPIE EUROPE: OPTICAL METROLOGY, 14-18 June, 2009, Munique, Alemanha. Proceedings... Society of Photho-optical Instrumentation Engineers, 2009. (SPIE Proceedings Series, 7390).

    Palavras-Chave: brazil; laser spectroscopy; breakdown; optical properties; tomography; cultural objects; bronze; damage; neutron activation analysis

  • IPEN-DOC 17636

    AMARAL, MARCELLO M. ; RAELE, MARCUS P. ; LANDULFO, EDUARDO ; NUNEZ, SILVIA C.; CAMPOS, GUSTAVO S.M. ; VIEIRA JUNIOR, NILSON D. ; WETTER, NIKLAUS U. ; FREITAS, ANDERSON Z. . LIDAR-like equation model for optical coherence tomography signal solution. In: WAX, ADAM P. (Ed.); BACKMAN, VADIM (Ed.) BIOMEDICAL APPLICATIONS OF LIGHT SCATTERING, V, January 22-24, 2011, San Francisco, California. Proceedings... Bellingham, Washington: Society of Photho-optical Instrumentation Engineers, 2011. p. 790714-1 - 790714-8.

    Palavras-Chave: tomography; optical systems; coherence length; scattering; samplers; mathematical models; optical radar; animal tissues; diagnosis

  • IPEN-DOC 11956

    GENEZINI, FREDERICO A. ; RAELE, MARCUS P. ; ZAHN, GUILHERME S. ; ZAMBONI, CIBELE B. . Multiparametric coincidence measurements of sup(155)SM beta-decay. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: beta-minus decay; coincidence spectrometry; data acquisition systems; europium 155; high-purity ge detectors; linear accelerators; multi-parameter analysis; samarium 155

  • IPEN-DOC 17637

    RAELE, MARCUS P. ; AMARAL, MARCELLO M. ; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. . Polarization sensitive and Mueller matrix OCT measurements and data analysis. In: FUJIMOTO, JAMES G. (Ed.); IZATT, JOSEPH A. (Ed.); TUCHIN, VALERY V. (Ed.) OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE, XV, January 24-26, San Francisco, California. Proceedings... Bellingham, Washington: Society of Photho-optical Instrumentation Engineers, 2011. p. 788939-1 - 788939-9.

    Palavras-Chave: tomography; optical systems; coherence length; matrices; polarization; interferometers

  • IPEN-DOC 24097

    COSTA, PRISCILA ; GERALDO, BIANCA ; RAELE, MARCUS P. ; MARUMO, JULIO T. ; VICENTE, ROBERTO ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Production of a square geometry americium standard source for use with photodiodes. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: In the development of a thermal neutron detector using a square photodiode and a thin boron film, a radioactive calibration source with the same geometry was needed. An americium-243 standard source was produced by electrodeposition aiming at the calibration of a PIN-type silicon photodiode with a detection area of 10 x 10 mm2. To produce the samples two tests were performed. In the first test, a square stainless steel plate (10 x 10 mm2) was fixed on the surface of the conventional plate, which was removed after deposition. To reduce the loss of activity of the source, in the second test nail polish was applied on the silver plate leaving only an area of 10 x 10 mm2 without varnish coating. Once the electrodeposition process was completed, the activity concentration measurement was performed by alpha particle spectrometry. The first method presented a lower activity when compared to the total activity of Am-243 added initially. For the second method, the total activity was concetrated in the exposed square region (without nail polish).The results showed that it is possible to obtain a square geometry source; furthermore, the surrounding nail polish was not contaminated by 243Am. The comparison of these two approaches indicated that the second method was more efficient as it was possible to concentrate all the americium activity in the delimitated square area.

    Palavras-Chave: americium 243; boron; calibration; electrodeposition; neutron detectors; photodiodes; brazilian cnen; silicon; square configuration; stainless steels; thermal neutrons; thin films

  • IPEN-DOC 14126

    AMARAL, MARCELLO M. ; RAELE, MARCUS P. ; CALY, JOSE P.; SAMAD, RICARDO E. ; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. . Roughness measurement methodology according to DIN 4768 using optical coherence tomography (OCT). In: SPIE EUROPE: OPTICAL METROLOGY, 14-18 June, 2009, Munique, Alemanha. Proceedings... Society of Photho-optical Instrumentation Engineers, 2009. (SPIE Proceedings Series, 7390).

    Palavras-Chave: optical properties; tomography; roughness; surface properties; standards

  • IPEN-DOC 12185

    FREITAS, ANDERSON Z. ; VELASCO, MARIA V.R.; RAELE, MARCUS P. ; KANEKO, TELMA M.; VIEIRA JUNIOR, NILSON D. ; BABY, ANDRE R.. Structural characterization of hair fiber by optical coherence tomography (OCT). In: PODOLEANU, ADRIAN (Ed.) CANTERBURY WOKSHOP ON OPTICAL COHERENCE TOMOGRAPHY ABND ADAPTIVE OPTICS, 1st, September 6, 2008, Canterbury, United Kingdom. Proceedings... Society of Photho-optical Instrumentation Engineers, 2008. p. 71390L-1 - 71390L-7. (SPIE Proceedings Series, 7139).

    Palavras-Chave: coherence length; michelson interferometer; hair; in vitro; tomography; optical models

  • IPEN-DOC 24703

    AMARAL, MARCELLO M.; RAELE, MARCUS P. ; ANA, PATRICIA A.; NUNEZ, SILVIA C.; ZAMATARO, CLAUDIA B. ; ZEZELL, DENISE M. . Wavelength comparison for laser induced breakdown spectroscopy caries detection. In: RECHMANN, PETER (Ed.); FRIED, DANIEL (Ed.) LASERS IN DENTISTRY, 24th, January 27 - February 01, 2018, San Francisco, California, USA. Proceedings... Bellingham, WA, USA: Society of Photo-optical Instrumentation Engineers, 2018. p. 104730K-1 - 104730K-6. (SPIE Proceedings Series, 10473). DOI: 10.1117/12.2288373

    Abstract: Laser Induced Breakdown Spectroscopy (LIBS) is a technique capable to perform elemental analyses of a variety of samples, independent of matter state. Other spectroscopy techniques may require a destructive and time-consuming sample preparation. On the other hand, LIBS is a less destructive technique with no (or considerably less) sample preparation, using a relatively simple experimental setup. LIBS also provides a multielement analysis into one single spectrum acquisition, applying a Nd:YAG short-pulsed laser to ensure the stoichiometry between the sample and the generated plasma. LIBS have been applied on the study of carious lesions using a Nd:YAG into its fundamental emission at 1064 nm. It was shown that ratio of P/Ca and Zn/Ca can be used to monitor the cariogenic process. Another minor elements, e.g. C and Cu, associated with bacteria biofilm were also measured with the Nd:YAG laser. The fundamental wavelength emission (1064 nm) of Nd:YAG is coincident with a hydroxyapatite transmission window and it may affect the result. In order to address this issue a study used the second harmonic of the Nd:YAG laser at 532 nm. It was show that it is also possible perform LIBS on carious lesion using the Nd:YAG at 532 nm. However, there is not a work direct comparing the LIBS at 532 nm and 1064 nm for carious lesion detection. So, the aim of this work was to investigate the influence of laser wavelength on the LIBS performance for carious lesion detection. In both cases the carious lesion was detected with the advantage of no interference with hydroxyapatite at 532 nm.

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.