Navegação Eventos - Artigos por Autores IPEN "FUKUMORI, NEUZA T.O."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 17170

    OLIVEIRA, IDELI M. de ; MARTINS, PATRICIA de A. ; SILVA, JOSE L. da ; RAMOS, MARCELO P.S. ; LIMA, JOSE A.S. ; PUJATTI, PRISCILLA B.; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Alternative methods for radiochemical purity testing in radiopharmaceutical. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: radiopharmaceuticals; radiochemical analysis; impurities; thin-layer chromatography; high-performance liquid chromatography

  • IPEN-DOC 12029

    FUKUMORI, NEUZA T.O. ; FERNANDES, ADRIANA V.; CAMPOS, DOMINGOS G. de ; GOMES, ANTONIO C. ; SILVA, NATANAEL G. da ; PEREIRA, NILDA P.S. de ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . A challenge for the validation of the gel clot test in radiopharmaceuticals produced in the radiopharmacy center. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: radiopharmaceuticals; endotoxins; gallium 67; thallium 201; infectivity; validation

  • IPEN-DOC 15119

    MONTEIRO, ELISIANE G.; ALMEIDA, ERIKA V.; RAMOS, MARCELO P.S. ; ALVES, EDSON V. ; BENEDETTI, STELLA; MENGATTI, JAIR ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Comparison of chromatography systems for radiochemical purity determination of lyophilized reagents labeled with technetium-99m. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: comparative evaluations; experimental data; impurities; labelling; quality control; radiochemistry; radiopharmaceuticals; technetium 99; thin-layer chromatography

  • IPEN-DOC 14325

    ALMEIDA, ERIKA V.; MONTEIRO, ELISIANE G.; ALVES, EDSON V. ; SILVA, NATANAEL G. da ; FUKUMORI, NEUZA T.O. ; BARBOZA, MARYCEL F. de ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. ; VASCONCELLOS, MARINA B.A. . Controle de qualidade e EC-sup(99m)Tc: determinacao de pureza radioquimica e investigacao da influencia de impurezas na biodistribuicao. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 14., 10-12 de outubro, 2009, Sao Paulo, SP. Anais... 2009.

    Palavras-Chave: chemical properties; diagnosis; diagnostic techniques; dynamic function studies; labelled compounds; radiopharmaceuticals; technetium 99; technetium; scintiscanning; tracer techniques

  • IPEN-DOC 14327

    ALMEIDA, ERIKA V. de; FUKUMORI, NEUZA T.O. ; MONTEIRO, ELISIANE G. de; MENGATTI, JAIR ; BARBOZA, MARYCEL R.F.F. ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . Desenvolvimento e validacao de metodo analitico por CET para determinacao de SAH em radiofarmaco de sup(99m)Tc. In: CONGRESSO DA QUALIDADE EM METROLOGIA, 1-4 de junho, 2009, Sao Paulo, SP. Anais... 2009.

    Palavras-Chave: chromatography; validation; albumins; blood serum; radiopharmaceuticals; labelled compounds; technetium 99

  • IPEN-DOC 19252

    MARTINS, PATRICIA de A. ; MOURA, REBECA G.; SHIKI, ANDRESSA M.; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Determination of radiochemical yield of sup(99m)Tc radiopharmaceutical preparations using gamma counter and linear radiochromatography scanner. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: technetium 99; radiochemistry; gamma detection; radiochromatography; radioisotope scanners

  • IPEN-DOC 26239

    SILVA, VITOR M.A. da ; SOUSA, JURANDIR A. de ; MARTINS, PATRICIA de A. ; FUKUMORI, NEUZA T.O. ; SILVA, NATANAEL G. da ; MATSUDA, MARGARETH M.N. . Dose calibrator and gamma counter: comparison of results in MIBI-TEC® biological distribution. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1860-1864.

    Abstract: To ensure that pharmaceutical products have and maintain the structure, identity, purity, concentration, potency and safety characteristics required for their use, there is a set of standard procedures called Good Manufacturing Practices (GMP). In Brazil, the National Sanitary Surveillance Agency (ANVISA) regulates the GMP production of medicines through RDC17/2010 and for radiopharmaceuticals through RDC 63/2009 and 38/2008, to ensure their safe and correct use in commercial production and nuclear medicine services, respectively. Most 99mTc radiopharmaceutical monographs have biological distribution specifications. Using invasive method, 99mTcradiopharmaceuticalsare assessed by the injection into animals of defined strains and the radioactivity (as percentage of retainedor injected dose -%RDor%ID)ismeasured in specified organs. Technetium-99m Sestamibi radiopharmaceutical (99mTc-2-methoxy-isobutyl-isonitrile; 99mTc-sestamibi; MIBI-TEC®) monograph is related in USP 41, but the biological distribution assay is not included. At IPEN, the biodistribution test is performed as established in the Radiopharmaceutical Quality Control Manual of ARCAL XV (1999) - International Atomic Energy Agency (IAEA), for each batch. The objective of this work is to compare MIBI-TEC®biodistribution results using dose calibrator and gamma counter with sodium iodide detector by measuring the radioactivity in the organs. Three batches of MIBI-TEC®were used and 1 vial of lyophilized reagent (LR) was labeled with 5-10 mCiin 1-3 mL of 99mTc eluate. 200-300 μCi in 0.2 mLwereinjected in 3 Balb-Cmice. After 30 minutes of biodistribution, heart, lung, muscle, liver, paw, column and tail were withdrawn, weighed and radioactivity was measured in dose calibrator and gamma counter (μCi andcpm, respectively). %ID/g ratio in the organs of interest was calculated using the data obtained by both equipment and the results were compared. No significant differences were observed and it was possible to conclude that either a dose calibrator or a gamma counter can be used in the routine of quality control.

    Palavras-Chave: calibration; comparative evaluations; quality control; radiation detectors; radiation dose distributions; radiation doses; radioactivity; radiopharmaceuticals; sodium iodides; technetium 99

  • IPEN-DOC 15117

    ALMEIDA, ERIKA V.; MONTEIRO, ELISIANE G.; MENGATTI, JAIR ; FUKUMORI, NEUZA T.O. ; SILVA, CONSTANCIA P.G. ; MATSUDA, MARGARETH M.N. . Effect of mobile phase on the RP-HPLC analysis of sup(99m)Tc-ECD. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: brain; chemical preparation; cysteine; ethanol; ethylene; experimental data; high-performance liquid chromatography; impurities; ph value; phosphates; radiochemistry; radiopharmaceuticals; reagents; retention; technetium 99

  • IPEN-DOC 12086

    MARTINS, PATRICIA de A. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. ; VICENTE, IRENE ; SILVA, LAERCIO ; EVEDOVE, SUELI D. ; MURAMOTO, EMIKO . Equivalence of the blockage of ureter and the action of the urethane in sup(99m)Tc-DMSA biodistribution in rats. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: biological localization; intravenous injection; radionuclide kinetics; radiopharmaceuticals; rats; technetium 99; ureters; urethane

  • IPEN-DOC 24107

    FUKUMORI, NEUZA T.O. ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. . Evaluation of 99Mo/99mTc generator columns after irradiation with different absorbed doses. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The 99Mo/99mTc generator is widely used in nuclear medicine and it consists of a glass column containing Teflon® strips and alumina in which 99Mo produced by 235U fission is adsorbed. The 99mTcO4- eluate shall meet the sterile and pyrogen free conditions for injectable radiopharmaceuticals as determined by the Good Manufacturing Practices. The purpose of this study was to evaluate the feasibility of using gamma radiation in the sterilization of the 99Mo/99mTc generator column and the influence on the elution efficiency. Alumina-containing columns were irradiated with 10, 15, 25 and 50 kGy absorbed doses. Alumina samples and control (non-irradiated) were submitted to X-ray diffraction and the combined use of scanning electron microscopy and elemental analysis. Teflon® samples were evaluated by thermogravimetry (TGA) and differential scanning calorimetry (DSC). X-ray diffractograms and micrographies with elemental analysis showed no significant changes in the crystalline structure of the alumina because it was stable α-Al2O3. TGA demonstrated that higher doses showed changes in lower temperatures and times than the control material. For DSC the higher the absorbed dose, the greater the polymer chain breakage and crosslinking in the material. The generator system without radioactivity was set up with the irradiated columns and the eluates demonstrated to be sterile and pyrogen free. The effects of different absorbed doses on the generator column, although some reported changes in the materials, demonstrated that the sterilization of the columns by irradiation with gamma rays as an alternative to wet heat sterilization is feasible from a technical and financial point of view.

    Palavras-Chave: absorbed radiation doses; aluminium oxides; calorimetry; cobalt 60; feasibility studies; molybdenum 99; radioisotope generators; sterilization; technetium 99; thermal gravimetric analysis

  • IPEN-DOC 15046

    BENEDETTI, STELLA; MONTEIRO, ELISIANE G.; ALMEIDA, ERIKA V.; OLIVEIRA, IDELI M. ; CERQUEIRA FILHO, ADEMAR ; MENGATTI, JAIR ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Evaluation of robustness in the validation of total organic carbon (toc) methodology. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: calibration standards; carbon dioxide; carbon; evaluation; experimental data; quality control; validation; water

  • IPEN-DOC 15036

    MARTINS, PATRICIA de A. ; SILVA, JOSE L. ; RAMOS, MARCELO P.S. ; OLIVEIRA, IDELI M. ; SILVA, NATANAEL G. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Identification, control and quantification of residual sol vents in radiopharmaceutical preparations. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: acetone; acetonitrile; benzyl alcohol; ethanol; ethyl ether; experimental data; gas chromatography; hot cells; methanol; propanols; radiopharmaceuticals; solvents

  • IPEN-DOC 15131

    SOUZA, ADRIANO A. ; HERRERIAS, ROSANA ; PIRES, JOSE A. ; ALVES, GERALDO P. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. ; ALMEIDA, ERIKA V.; MENGATTI, JAIR ; BARBOSA, MARYCEL F. . Improvement in the sup(111)In-DTPA-TYRsup(3) octreotide and sup(177)Lu-DOTA-TYRsup(3) octreotate production. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: dtpa; gloveboxes; high-performance liquid chromatography; impurities; indium 111; labelling; lutetium 177; neoplasms; quality control; radiochemistry; radionuclide kinetics; radiopharmaceuticals; radiotherapy; scintiscanning; tissue distribution

  • IPEN-DOC 16139

    MONTEIRO, ELISIANE G.; ALMEIDA, ERIKA V.; BENEDETTI, STELLA; ALVES, EDSON V. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Medodo alternativo para a determinacao de pureza radioquimic de MIBI-sup(99m)Tc. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 15., 18-21 de agosto, 2010, Aracaju, SE. Anais... 2010.

    Palavras-Chave: nuclear medicine; technetium 99; isonitriles; radiopharmaceuticals; high-performance liquid chromatography

  • IPEN-DOC 15768

    ALMEIDA, ERIKA V. ; SILVA, NATANAEL G. ; FREIRE, ANTONIO C. ; MONTEIRO, ELISIANE de G. ; BENEDETTI, STELLA ; MURAMOTO, EMIKO ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. ; VASCONCELLOS, MARINA B.A. . Metodo cintilografico nao invasivo para estudo de biodistribuicao de radiofarmacos. In: CONGRESSO BRASILEIRO DE FISICA MEDICA, 15., 18-21 de agosto, 2010, Aracaju, SE. Anais... 2010.

    Palavras-Chave: radiopharmaceuticals; biological localization; tissue distribution

  • IPEN-DOC 19423

    TAVARES, ANGELICA T.; MARTINS, PATRICIA de A.; FUKUMORI, NEUZA T.O. ; MENGATTI, JAIR ; MATSUDA, MARGARETH M.N. . Multielemental determination of trace elements in radiopharmaceuticals produced at the radiopharmacy center using ICP-OES technique. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: radiopharmaceutical; radiopharmaceuticals; sample preparation; concentration ratio; elements; trace amounts; icp mass spectroscopy; radioisotope generators; brazilian cnen; quality control; validation

  • IPEN-DOC 21021

    CASTRO, THAIS O.M. de ; MENGATTI, JAIR ; MATSUDA, HYLTON ; ARAUJO, ELAINE B. de ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. . Otimização das condições de análise CIDG e, FDG por cromatografia liquida de alta eficiência (CLAE) acoplado a detector amperométrico pulsado (DAP). In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: radiopharmaceuticals; fluorodeoxyglucose; positron computed tomography; high-performance liquid chromatography; radiation detectors; diagnosis; nuclear medicine

  • IPEN-DOC 12104

    SEBASTIAN, MARIA V.A.; LUGON, MARCELO DI M.V.; SILVA, JOSE L. da ; FUKUMORI, NEUZA T.O. ; PEREIRA, NILDA P.S. de ; SILVA, CONSTANCIA P.G. da ; MATSUDA, MARGARETH M.N. . Polarographic determination of Sn(II) and total Sn in pyro and mdp radiopharmaceutical kits. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: experimental data; hydrogen peroxide; lyophilization; oxidation; phosphonic acids; polarography; pyrophosphates; quality control; radiopharmaceuticals; tin ions; tin

  • IPEN-DOC 15035

    MARTINS, PATRICIA de A. ; OLIVEIRA, IDELI M. ; FUKUMORI, NEUZA T.O. ; MATSUDA, MARGARETH M.N. ; OSSO JUNIOR, JOAO A. . Preliminary studies of separation of sup(67) Ga from electroplated Zn targets. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: acetic acid; citrates; copper; electroplating; emission spectroscopy; gallium 67; heating; nickel; targets; temperature range 0273-0400 k; temperature range 0400-1000 k; thermal diffusion; zinc

  • IPEN-DOC 26245

    SANTOS, JOEL M. dos; FUKUMORI, NEUZA T.O. ; OLIVEIRA, IDELI M. de ; MARTINS, PATRICIA de A. ; SILVA, NATANAEL G. da ; MATSUDA, MARGARETH M.N. . Proposal of an identification test for MIBI-TEC® lyophilized reagent using infrared spectroscopy. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1984-1988.

    Abstract: Quality Control is part of the Good Manufacturing Practices (GMP) responsible for the evaluation and release of pharmaceutical components, including active ingredients and excipients, to assure compliance with the specifications in pharmacopoeias. GMP for radiopharmaceuticals is regulated by RDC N. 17/2010 and RDC N. 63/2009 (ANVISA) establishing the minimum quality standards in industrial manufacture. Pharmacopoeias have the specifications for lyophilized reagents (LR) labeled with 99mTc regarding radiochemical purity, biodistribution and, in case of parenteral use, bacterial endotoxins and sterility tests must be performed. In radiopharmaceutical monographs, the necessity of non radioactivity assays for releasing lyophilized reagents are not well described, but ANVISA requires assays to assure the quality of the lyophilized powder, as active ingredient quantification and identification assays, stannous ion quantification and moisture determination. Infrared (IR) spectroscopy is widely used for identification of substances, mainly raw materials. The aim of this work is to propose an identification assay for MIBI-TEC® LR powder using IR spectroscopy. MIBI-TEC® batches were produced at IPEN/CNEN-SP and about 2 mg of the LR powder were mixed with 200 mg KBr, pressed at 80 kgf during 5 minutes into the holder to obtain a transparent pellet. The pellet was placed in ABB IR spectrometer, FTLA 2000 model, and a spectrum in the medium infrared region of 450 to 4000 cm-1 was acquired using Grams software. Tetramibi cuprous tetrafluoroborate, stannous chloride dihydrate, cysteine hydrochloride monohydrate, sodium citrate and mannitol had their respective IR spectrum recorded and the main characteristic absorptions were established for each formulation component. In the MIBI-TEC® spectrum, it was possible to observe a well characterized absorption in 2193 cm-1 which represents the presence of C≡N binding of tetramibi cuprous tetrafluoroborate active ingredient, free of interference, indicating that IR spectrum can be used as identification assay of the LR.

    Palavras-Chave: drugs; infrared spectra; infrared spectrometers; lyophilization; radiopharmaceuticals; reagents; technetium 99

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.