Navegação Eventos - Artigos por Autores IPEN "KOSKINAS, MARINA F."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 12122

    PIASENTIN, RICARDO M. ; KOSKINAS, MARINA F. ; RAJPUT, M.U.; MAIDANA, NORA L.; VANIN, VITO R.; DIAS, MAURO S. . A comparative study for the correction of random gamma ray summing effect in HPGe- detector based gamma ray spectrometry. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: americium 241; cesium 137; counting rates; experimental data; gamma spectroscopy; high-purity ge detectors; radiation sources; regression analysis

  • IPEN-DOC 12120

    DIAS, MAURO S. ; CARDOSO, VANDERLEI; FIGUEIREDO, ANA M.G. ; KOSKINAS, MARINA F. . Covariance analysis of detection processes in K0 NAA methodology. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: data covariances; efficiency; experimental data; gamma spectroscopy; iear-1 reactor; lanthanum 140; neutron activation analysis; radiation sources; scandium 46

  • IPEN-DOC 21069

    BARROS, LIVIA F. ; DIAS, MAURO S. ; KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; SEMMLER, RENATO . Determination of ksub(0) for sup(63)Cu(n,'gamma')sup(64)Cu reaction with covariance analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: neutron activation analysis; copper 63; copper 64; reactors; irradiation; iear-1 reactor; high-purity ge detectors; gamma spectrometers; data covariances

  • IPEN-DOC 16107

    MOREIRA, DENISE S.; KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; DIAS, MAURO S. . Determination of sup(51)Cr and sup(241)Am X-ray and gamma-ray emission probabilities per decay. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 7th, June 22-27, 2008, Praga, Republica Tcheca. Proceedings... 2008.

    Palavras-Chave: chromium 51; americium 241; x radiation; gamma radiation; decay; probability; semiconductor detectors

  • IPEN-DOC 11974

    KOSKINAS, MARINA F. ; PIRES, CARLOS A.; SILVA, ELIEZER A. da; YAMAZAKI, IONE M. ; DIAS, MAURO S. . Disintegration rate measurements of sup(51)Cr and sup(54)Mn radioactive solutions. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: chromium 51; manganese 54; radioisotopes; calibration standards; ionization chambers; spectrometers; elements; trace amounts; iron 55; gamma spectrometers

  • IPEN-DOC 24136

    KOSKINAS, MARINA F. ; ALMEIDA, JAMILLE da S. ; MOREIRA, DENISE S. ; SEMMLER, RENATO ; DIAS, MAURO da S. . Gamma-ray impurities of 111In, 201Tl, 177Lu and 99mTc determined by means of a HPGE spectrometer. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: This work aims to present the radioactive impurities gamma rays emitters detected in some radiopharmaceuticals widely applied to diagnosis and therapy purposes, supplied to nuclear medicine services in Brazil by the Radiopharmaceutical Center(CR) of Nuclear and Energy Research Institute, IPEN, in São Paulo. The analysis was undertaken by means of an HPGe gamma spectrometer. The radiopharceuticals analyzed were: 111In, 201Tl, 177Lu and 99mTc.

    Palavras-Chave: concentration ratio; gamma radiation; high-purity ge detectors; impurities; indium 111; lutetium 177; monte carlo method; quality control; radiopharmaceuticals; technetium 99; thallium 201

  • IPEN-DOC 22870

    ALMEIDA, JAMILLE da S. ; KOSKINAS, MARINA F. ; MARQUES, CAIO P. ; MOREIRA, DENISE S. ; DIAS, MAURO da S. . Impurity determination in 153Sm by means of a High Purity Germanium spectrometer. In: CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇOES IONIZANTES, 3., 21-23 de novembro, 2016, Rio de Janeiro, RJ. Anais... 2016. p. 1-5.

    Abstract: Neste trabalho, a impureza radionuclídica de longa duração 152Eu, presente na solução de 153Sm, foi medida por meio de um espectrômetro de HPGe, calibrado na faixa de energia entre 81 e 1408 keV por meio de soluções padronizadas em ampolas seladas de 60Co, 133Ba, 137Cs e 152Eu. A razão entre as atividades do 152Eu e do 153Sm resultou 5,2x10-6. Este valor é menor que o limite estabelecido pelo controle de qualidade.

    Palavras-Chave: europium 152; gamma spectroscopy; high-purity ge detectors; impurities; quality control; samarium 153

  • IPEN-DOC 16772

    FONSECA, KATIA A. ; KOSKINAS, MARINA F. ; DIAS, MAURO da S. . Measurement of the gamma-ray probability per decay of sup186)Re. In: NUCLEAR SCIENCE SYMPOSIUM/MEDICAL IMAGING CONFERENCE, October 19-25, 2008, Dresden, Germany. Proceedings... 2008. p. 281-285. DOI: 10.1109/NSSMIC.2008.4774566

    Palavras-Chave: rhenium 186; gamma radiation; decay; standardization; high-purity ge detectors; nuclear medicine

  • IPEN-DOC 12015

    KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; SILVA, PAULO R.; ANDRADE e SILVA, LEONARDO G. ; VIEIRA, JOSE M. ; DIAS, MAURO S. . Optimization of the method for preparing water-equivalent solid sources. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: acrylamide; activity levels; aqueous solutions; barium 133; cesium 137; cobalt 57; cobalt 60; gamma sources; optimization; polymerization; radiation doses; resins

  • IPEN-DOC 24065

    BARROS, LIVIA F. ; DIAS, MAURO S. ; KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; SEMMLER, RENATO . Preliminary measurements of k0 values for W-186. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: There are various methods of neutron activation analysis, one of these is the k0 Method for quantitative reactor Neutron Activation Analysis (NAA). The k0-NAA procedure is nowadays widely used in numerous laboratories performing NAA all over the world. Among these reactions, 186W(n, )187W can be considered important because it can be used for a W concentration measurements. The irradiations were performed at position 24A, near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP – Nuclear and Energy Research Institute), in São Paulo, Brazil. Two irradiations were carried out in sequence, using two sets of samples: the first with a cadmium cover around the samples and the second without, in a total of three data sets with and without Cd cover performed in 2014 and 2015. The activity measurements were carried out in an HPGe gamma-ray spectrometer. Standard sources of 152Eu, 133Ba, 60Co and 137Cs supplied by the IAEA were used in order to obtain the HPGe gamma-ray peak efficiency as a function of the energy. The covariance matrix methodology was applied to all uncertainties involved. The preliminary values of k0 for 186W(n, )187W reaction for the gamma transition energy of 479.53 keV was 3.17x10-2(5), for 618.77 keV was 9.08x10-3(15) and for 685.77 keV was 3.88x10-2(6). These preliminary values for k0 have been compared with the literature.

    Palavras-Chave: activity levels; cadmium; data covariances; high-purity ge detectors; neutron activation analysis; tungsten 186

  • IPEN-DOC 26201

    KOSKINAS, MARINA F. ; KUZNETSOVA, MARIA ; MOREIRA, DENISE S. ; SCHOUERI, ROBERTO M. ; MORAIS, THALES S.L. de ; SEMMLER, RENATO ; DIAS, MAURO da S. . Preliminary measurements using a Triple to Double Coincidence Ratio (TDCR) Liquid Scintillator Counter System. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1125-1131.

    Abstract: The preliminary measurements using a Triple to Double Coincidence Ratio (TDCR) Liquid Scintillator Counter System developed by the Nuclear Metrology Laboratory (LMN) at IPEN, is presented. The TDCR system makes use of three photomultipliers positioned at 120° relative angle, operating in coincidence. For this preliminary measurement, 14C was selected to be standardized. This solution was previously calibrated by the efficiency tracing technique using a  (PC) coincidence system, employing 60Co as a tracer. 14C was chosen due to be a beta pure emitter with low end-point energy of 156 keV. The Software Coincidence System (SCS) developed by the LMN was used for both systems to register the events. MICELLE 2 code was used to calculate the theoretical TDCR efficiency. Measurements using HIDEX, a commercial liquid scintillator system, were also carried out and the results from the three methods were compared, showing a good agreement.

    Palavras-Chave: carbon 14; cobalt 60; comparative evaluations; liquid scintillators; photomultipliers; standardization; tracer techniques; brazilian cnen

  • IPEN-DOC 26202

    MORAIS, THALES S.L. de ; KOSKINAS, MARINA F. ; MOREIRA, DENISE S. ; DIAS, MAURO da S. . Preliminary study of radionuclide standardization by TDCR method applying a time-to-amplitude converter. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1147-1155.

    Abstract: This paper proposes an alternative to the use of counters for the standardization of radionuclides in a 3-photodetectors liquid scintillation counter by the triple to double coincidence ratio (TDCR) method using an electronic system for processing pulses that allows the subtraction of the accidental coincidences. The electronic system consists of ampli ers, discriminators, logic gates and delay modules feeding a time-to-amplitude converter (TAC) with output to a multichannel analyzer (MCA). This system does not require individual counters for each photodetector and coincident counts contribute to the noise reduction. The method compares 3 di erent TAC spectra registered in MCA with 4, 3 or 2 peaks obtained from di erent con gurations of the electronic system. For testing the system, a series of measurements with a 90Sr standard solution was performed.

    Palavras-Chave: carbon 14; cobalt 60; comparative evaluations; liquid scintillators; photomultipliers; standardization; tracer techniques; brazilian cnen

  • IPEN-DOC 17094

    YAMAZAKI, IONE M. ; KOSKINAS, MARINA F. ; DIAS, MAURO S. . Preparation of water-equivalent radioactive solid sources. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: gamma sources; calibration; accuracy; standards; gamma spectroscopy; polymerization

  • IPEN-DOC 24096

    KOSKINAS, MARINA F. ; MARQUES, CAIO P. ; MOREIRA, DENISE S. ; RAJPUT, MUHAMMAD U.; YAMAZAKI, IONE M. ; DIAS, MAURO S. . Primary standardization of 90Sr-90Y radioactive solution. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: In the present work, the procedure developed by the Nuclear Metrology Laboratory (LMN) at IPEN, for the primary standardization of 90Sr-90Y, is presented. The method applied has been the efficiency tracing technique using a  coincidence system. That consists in the measurement of a beta pure emitter along with a beta-gamma emitter, previously standardized, which will provide the beta efficiency. In this work, the beta-gamma emitter used was 60Co. The beta efficiency has varied using external absorbers, and the specific activity was determined using the extrapolation curve. ESQUEMA Code, which predicts the extrapolation curve by means of Monte Carlo technique, was applied, and the specific activity obtained from Monte Carlo simulation was compared with the experimental, showing good agreement within the experimental uncertainties.

    Palavras-Chave: beta particles; strontium 90; yttrium 90; cobalt 60; coincidence methods; decay; e codes; efficiency; monte carlo method

  • IPEN-DOC 22879

    MARQUES, CAIO P. ; KOSKINAS, MARINA F. ; ALMEIDA, JAMILLE da S. ; YAMAZAKI, IONE M. ; DIAS, MAURO da S. . Standardization of 32P radioactive solution. In: CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇOES IONIZANTES, 3., 21-23 de novembro, 2016, Rio de Janeiro, RJ. Anais... 2016. p. 1-6.

    Abstract: The standardization of 32P radioactive solution using three different methods is presented. The disintegration rate was determined by the CIEMAT/NIST and TDCR methods in liquid scintillator systems and self-absorption extrapolation method using PC) system. The results obtained for the activity of the 32P solution were compared and they agree within the experimental uncertainties.

    Palavras-Chave: liquid scintillators; phosphorus 32; radiation protection; radioactivity; standardization

  • IPEN-DOC 20990

    KOSKINAS, MARINA F. ; KUZNETSOVA, MARIA ; YAMAZAKI, IONE ; BRANCACCIO, FRANCO ; DIAS, MAURO S. . Standardization of C-14 by tracing method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: standardization; carbon 14; tracer techniques; cobalt 60; liquid scintillators

  • IPEN-DOC 17136

    KOSKINAS, MARINA F. ; LITVAK, FERNANDA; BRITO, ANDREIA B. de; DIAS, MAURO da S. . Standardization of S-35 radioactive solution in liquid scintillation counting system by means of the CIEMAT/NIST method compared with 4'pi''beta'-'gamma' tracing method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 10th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 17th; MEETING ON NUCLEAR INDUSTRY, 2nd, October 24-28, 2011, Belo Horizonte, MG. Proceedings... Sao Paulo: ABEN, 2011, 2011.

    Palavras-Chave: brazilian cnen; laboratories; measuring instruments; sulfur 35; radioactive materials; standardization; liquid scintillation detectors

  • IPEN-DOC 15085

    KOSKINAS, MARINA F. ; PIRES, CARLOS A.; RAJPUT, MUHAMMAD U.; YAMAZAKI, IONE M. ; MOREIRA, DENISE S.; DIAS, MAURO S. . Standardization of TI-201 radioactive solution. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 9th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 16th; MEETING ON NUCLEAR INDUSTRY, 1st, September 27 - October 2, 2009, Rio de Janeiro, RJ. Proceedings... Sao Paulo: ABEN, 2009, 2009.

    Palavras-Chave: coincidence methods; computerized simulation; decay; e codes; efficiency; experimental data; extrapolation; gamma sources; monte carlo method; multi-channel analyzers; nai detectors; proportional counters; standardization; thallium 201

  • IPEN-DOC 19333

    NASCIMENTO, TATIANE S.; KOSKINAS, MARINA F. ; MATOS, IZABELA T.; YAMAZAKI, IONE M. ; RAJPUT, MOHAMED U.; DIAS, MAURO S. . Standardization of Y-90 by tracing method. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 11th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 18th; MEETING ON NUCLEAR INDUSTRY, 3rd, November 24-29, 2013, Recife, PE. Proceedings... Sao Paulo: ABEN, 2013, 2013.

    Palavras-Chave: brazilian cnen; coincidence methods; decay; monte carlo method; sodium 24; standardization; tracer techniques; yttrium 90

  • IPEN-DOC 26312

    CARVALHO, ANA C.R. de ; MOREIRA, DENISE S. ; KOSKINAS, MARINA F. ; DIAS, MAURO da S. . Standartization of (166m)Ho in a coincidence system by software and determination of its gamma emission probabilities. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 2978-2982.

    Abstract: This works presents a new standardization of the radionuclide (166m)Ho that was carried out at Nuclear Metrology Laboratory (LMN) at IPEN. (166m)Ho decays with 1133 years of half-life by beta emission followed by a cascade of gamma-rays in a range of 73 to 1427 keV, and these characteristics makes it a good secondary standard to the calibration of gamma spectrometers. Previously calibrated with a standard 4 Pi(PC)Beta-Gama coincidence system, the same samples were now measured in the Software Coincidence System (SCS), where the data analyses can be done after the measurements, using a software developed at LMN as well. The SCS is composed of a 4Pi geometry proportional counter operated at 0.1MPa coupled to one NaI(Tl) crystal, positioned above the PC counter, and to a HPGe detector, positioned below the PC counter. The signals from all detectors are digitalized and their pulses height and time of occurrence are recorded on computer files. After the standardization, the emission probabilities per decay of the most intense gamma-rays in the (166m)Ho decay were determined by means of a HPGe spectrometer system, which was calibrated with standard sources previously calibrated in the 4 Pi(PC)Beta-Gama coincidence system, and the results were compared with the literature. All the uncertainties were treated by the covariance analysis method.

    Palavras-Chave: holmium 166; coincidence methods; radioisotopes; programming; computer codes; standardization; gamma spectroscopy; measuring methods; decay

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.