Navegação Eventos - Artigos por assunto "data covariances"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 26345

    MADEIRA, ALZIRA A.; PEREIRA, LUIZ C.M.; SABUNDJIAN, GAIANE . An Angra 2 LBLOCA simulation model for RELAP5MOD3.3 code with uncertainty analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 4476-4502.

    Abstract: This paper describes the activities related to the work planned within Project BRA3.01/12 between CNEN and the European Community, relatively to its Task 2.1 (independent uncertainty quantification and sensitivity analysis utilizing the computational tool SUSA for the calculus related to LOCA simulation for licensing matter). SUSA software has been applied to the reference case, a double-ended LBLOCA in Angra 2, simulated with a RELAP5 code nodalization developed by the thermal hydraulic technicians of CNEN and its research institutes. This original nodalization has been improved for the development of the main objective of Task 2.1. The recommendations that our European counterparts provided on the last workshop, held at CNEN in Rio de Janeiro from January 28th to February 2nd, 2018, have been implemented as far as feasible.

    Palavras-Chave: angra-2 reactor; boundary conditions; cladding; data covariances; lbloca; pressure vessels; r codes; reactor accident simulation; reactor cores; s codes; steady-state conditions

  • IPEN-DOC 08784

    CARVALHO, M.A.G.; HIROMOTO, G. . Aplicacao do modelo de dois componentes para calculo de erro, a analise de dados de monitoracao ambiental. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; NATIONAL MEETING ON NUCLEAR APPLICATIONS, 6th, Aug. 11-16, 2002, Rio de Janeiro, RJ. Proceedings... Rio de Janeiro: ABEN, 2002, 2002.

    Palavras-Chave: radiation monitoring; environment; alpha detection; data covariances; statistics

  • IPEN-DOC 10956

    MOREIRA, E.G. ; VASCONCELLOS, M.B.A. ; SAIKI, M. . Avaliacao da incerteza associada a solucoes padrao em analise quimica: estudo de caso para a diluicao de uma solucao de molibdenio. In: ENCONTRO PARA A QUALIDADE DE LABORATORIOS, 1-3 jun, 2004, Sao Paulo, SP. Anais... 2004.

    Palavras-Chave: molybdenum; dilution; chemical analysis; data covariances; validation

  • IPEN-DOC 26378

    GOMES, DANIEL de S. ; GIOVEDI, CLAUDIA. Combining probabilistic and deterministic methods for accident analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 5429-5442.

    Abstract: This study describes a practical method applied to nuclear reactor safety analysis (NRSA), based on an approach so-called best estimate plus uncertainty (BEPU). The innovative analysis approach involves statistical methods integrated with deterministic rules to fuel licensing code (FLC). The goal of NRSA is to improve safety margins in the nuclear reactor operation, which has partially achieved with uncertainty treatment. Previously, BEPU analysis was widely used to study the loss of coolant accident (LOCA), via inclusion in thermal-hydraulic codes (THC). The systems can measure the impact caused by uncertainties spread in core reactors with a coupling of THC and optimization packages. This paper shows the result of applying the UA/SA technique to FRAPCON, joined with DAKOTA toolkit. This integration will offer the probabilistic analysis coupled with empirical rules. A perfect fusion of the concepts permits the exploration of parametric uncertainties and calibration of physical models. We can use the combined utilization of FLC systems and the DAKOTA toolkit to produce sensitivity analysis. The first step in this approach is to identify all uncertainty sources of the physical models, the reactor design, and manufacturing parameters. It is subsequently used into an FLC, such as FRAPCON, as input parameters. The uncertainties usually distributed using the Wilks formula, which determines the number of samples required for unilateral tolerance. According to Wilks' method, it needs 59 data samples to achieve a confidence level of 95%. Results from Wilks formula found via Monte Carlo simulation, which applies to FLC coupled with sensitivity analysis.

    Palavras-Chave: cladding; data covariances; deterministic estimation; f codes; fuel rods; loss of coolant; probabilistic estimation; reactivity; reactor accidents; reactor cores; reactors; safety analysis; sensitivity analysis; transients

  • IPEN-DOC 12120

    DIAS, MAURO S. ; CARDOSO, VANDERLEI; FIGUEIREDO, ANA M.G. ; KOSKINAS, MARINA F. . Covariance analysis of detection processes in K0 NAA methodology. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: data covariances; efficiency; experimental data; gamma spectroscopy; iear-1 reactor; lanthanum 140; neutron activation analysis; radiation sources; scandium 46

  • IPEN-DOC 10663

    ANDRADE, M.C.V.; NASCIMENTO, C.A.O.; MIGLIAVACCA, S.C.P. . Detection of outliers in gas centrifuge experimental data. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE FISICA E REATORES THERMAL HIDRAULICA, 14th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: data covariances; errors; experimental data; gas centrifuges; isotope separation; neural networks; optimization; ultracentrifuges

  • IPEN-DOC 08025

    VIVOLO, V. ; COSTA, A.M.; MANZOLI, J.E. ; CALDAS, L.V.E. . Determinacao dos parametros dos campos de radiacao gama do Laboratorio de Calibracao do IPEN. In: FROTA, M.N. (Ed.); CARMO, L.C.S. (Ed.) INTERNATIONAL CONFERENCE ON ADVANCED METROLOGY IN CHEMISTRY AND LABORATORY QUALITY; BRAZILIAN CONGRESS OF METROLOGY, 2nd; INTER-AMERICAN CONGRESS ON METROLOGY IN CHEMISTRY, 2nd; NATIONAL MEETING OF ACCREDITED LABORATORIES, 2nd, Dec. 4-7, 2000, Sao Paulo, SP. Proceedings... 2000.

    Palavras-Chave: radiation detectors; portable equipment; gamma radiation; calibration; data covariances; radiation sources; americium 241; cesium 137; cobalt 60

  • IPEN-DOC 21069

    BARROS, LIVIA F. ; DIAS, MAURO S. ; KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; SEMMLER, RENATO . Determination of ksub(0) for sup(63)Cu(n,'gamma')sup(64)Cu reaction with covariance analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 12th; MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 19th; MEETING ON NUCLEAR INDUSTRY, 4th, October 4-9, 2015, São Paulo, SP. Proceedings... 2015.

    Palavras-Chave: neutron activation analysis; copper 63; copper 64; reactors; irradiation; iear-1 reactor; high-purity ge detectors; gamma spectrometers; data covariances

  • IPEN-DOC 26197

    ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Efficiency stability of HPGe detectors under distinct count rates. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 1092-1096.

    Abstract: In this work the reproducibility of the e ciency of di erent HPGe detectors was analyzed under a series of di erent conditions. The detectors studied were plugged either to a regular analogical ampli er or to a digital signal processing (DSP) device, in order to evaluate the possible di erences between either setup. Detectors were inspected by performing a long series of sequential measurements with standard calibration sources, and comparing the standard deviation of the number of counts per second in each series to the uncertainty of the individual measurements. Detectors were also subjected to distinct count rates, in order to verify the possible experimental issues associated with this parameter. The results allow a discussion on the stability of the detectors' e ciencies over a few days, the possible dependence with the count rate, and the estimation of the uncertainty related to the e ciency variation.

    Palavras-Chave: calibration standards; comparative evaluations; data covariances; efficiency; high-purity ge detectors; stability

  • IPEN-DOC 08561

    CANTAGALLO, M.I.C.. Estimativa de incertezas na titulacao redox de uranio - aplicacao pratica. In: CONGRESSO INTERNACIONAL DE METROLOGIA EM QUIMICA, 3, 30 set. - 3 out, 2002, Curitiba, PR. Anais... 2002.

    Palavras-Chave: uranium; redox potential; titration; potentiometry; data covariances

  • IPEN-DOC 24074

    ZAHN, GUILHERME S. ; TICIANELLI, REGINA B. ; SAIKI, MITIKO ; GENEZINI, FREDERICO A. . Evaluation of the uncertainty associated with sample holders in NAA measurements in LAN/IPEN. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: In IPEN’s Neutron Activation Laboratory (LAN/IPEN), thin stainless steel sample holders are used for gamma spectrometry in NAA measurements. This material is very practical, but its chemical composition may be troublesome, as it presents large amounts of elements with intermediate atomic number, with attenuation factors for low-energy gamma-rays that must not be neglected. In this study, count rates obtained using different sample holders were compared. To accomplish that, an Am-241 source, with 59-keV gamma emission, was used so that low-energy gamma attenuation differences can be determined. Moreover, in order to study the energy dependence of these differences, a Ho-166m source was also used. From these results, it was possible to analyze the experimental error associated to the variations between sample holders, with the aim of introducing an addictive term to the uncertainty analysis of comparative Neutron Activation Analysis results.

    Palavras-Chave: neutron activation analysis; sample holders; americium 241; holmium 166; gamma spectroscopy; data covariances; stainless steels; comparative evaluations; brazilian cnen; energy dependence; counting rates

  • IPEN-DOC 26361

    GOMES, DANIEL de S. ; GIOVEDI, CLAUDIA. Importance of uncertainty modelling for nuclear safety analysis. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 5010-5023.

    Abstract: The U.S. Nuclear Regulatory Commission (NRC) reviewed the 10CFR50.46c regulations regard the loss-of-coolant-accident (LOCA), and emergency core cooling system (ECCS). In this planned rulemaking named as 10CFR50.46c. New LOCA criteria included the integration of models used to the hydrogen uptake changes equivalent cladding react (ECR), coupled with peak cladding temperature (PCT). This rule inserts the embrittlement mechanism considering the hydrogen buildup as a pre-transient condition, reducing a loss of operational margin. 10CFR50.46c criteria should combine the effects produced from different fields, such as neutronic analysis, thermal-hydraulic, with fuel performance codes. Besides, it should contemplate Best-Estimate Plus Uncertainty (BEPU) practices. Consequently, increases the challenges to safety analysis because of nuclear power plants run for extended periods than planned initially. In these circumstances, nuclear units need to operate on extended life cycles based on safety margins. With a lifespan of 60 years or more, we reviewed the behavior of the structural material on accident scenarios. This work showed the importance of uncertainties created by physical models such as the fission gas release, thermal conductivity, and loss of ductility caused by hydrides.

    Palavras-Chave: cladding; data covariances; f codes; fuel rods; l codes; lifetime extension; loss of coolant; nuclear fuels; safety analysis; sensitivity analysis; steady-state conditions; thermal hydraulics; transients

  • IPEN-DOC 12130

    POTIENS, MARIA da P.A. ; LUCENA, RODRIGO F.; SANTOS, GELSON P. ; VIVOLO, VITOR . Improvement of gamma calibration procedures with commecial management software. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... São Paulo: ABEN, 2007, 2007.

    Palavras-Chave: a codes; air; calibration; cesium 137; cobalt 60; data covariances; experimental data; gamma radiation; iso; kerma; laboratory equipment; portable equipment; radiation sources

  • IPEN-DOC 09889

    HORTELLANI, M.A. ; SARKIS, J.E.S. . Incerteza associada a determinacao de mercurio em sedimentos. In: CONGRESSO BRASILEIRO DE METROLOGIA - METROLOGIA PARA A VIDA, 3., 1-5 set, 2003, Recife, PE. Anais... 2003.

    Palavras-Chave: sediments; mercury; diagrams; absorption spectroscopy; data covariances

  • IPEN-DOC 26383

    VIEIRA NETO, ANTONIO S. ; OLIVA, AMAURY M. ; SAUER, MARIA E.L.J. ; HUNOLD, MARCOS C. ; OLIVEIRA, PATRICIA da S.P.de ; ANDREA, VINICIUS . Knowledge base about risk and safety of nuclear facilities to support analysts and decision makers. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 5513-5522.

    Abstract: Epistemic uncertainty (uncertainty related to lack of knowledge), often found in the documentation of nuclear facility engineering projects, can affect the decision-making process of managers and analysts on safety and risk issues. This article conceptualizes the nature of the major uncertainties involved in engineering projects and describes a knowledge base developed in order to gather data and information related to the project of an Open-Pool Light-water Research Rector (OPLRR) and whose purpose is to assist professionals who work in the áreas of safety, design, operation, and maintenance of nuclear facilities. In order to reduce the epistemic uncertainties that may rise in the project, the OPLRR knowledge base is designed to contain a set of information that allows identifying and facilitating the forwarding of solutions to address inconsistencies, and/or pending issues that may exist in the project. In this sense, the information and the documents related to the project are organized in a graphical and hierarchical architecture, allowing the knowledge base users to quickly and easily obtain information regarding the systems, processes, equipment, and components of the Project. Besides that, a set of documents containing descriptions, reliability data and some other important information about the systems and components are specially created to the knowledge base and it is crucial to reduce epistemic uncertainties, once it raises the issues and the inconsistencies of the project, as well as it clarifies the interrelations between the systems, the functioning of the equipment, their failures modes and the consequences of their failures, and some other data, which are not originally contained in the documents of the project.

    Palavras-Chave: data covariances; decision making; design; information dissemination; knowledge base; maintenance; nuclear facilities; personnel; pool type reactors; reactor cores; risk assessment; safety

  • IPEN-DOC 10618

    MOREIRA, E.G. ; VASCONCELLOS, M.B.A. ; SAIKI, M. . Measurement uncertainty assessment in the instrumental neutron activation analysis of chromium, manganese, molybdenum and nickel in steel. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: calibration standards; concentration ratio; data covariances; experimental data; low alloy steels; multi-element analysis; neutron activation analysis; quality assurance

  • IPEN-DOC 26156

    TAPPIZ, BRUNO ; MOREIRA, EDSON G. . Measurement uncertainty evaluation in fish samples analyzed by INAA and AAS. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 521-528.

    Abstract: Measurement uncertainty was estimated following the EURACHEM guide (Quantifying Uncertainty in Analytical Measurement) for the elements As, Br, Cl, Co, Cr, Cs, Fe, K, Mg, Mn, Na, Rb, Sb, Se and Zn determined by Instrumental Neutron Activation Analysis (INAA) and for the elements Cd, Hg and Pb determined by Atomic Absorption Spectrometry (AAS) in the fillet of the most consumed fish species at São Paulo city, Brazil. INAA expanded uncertainties ranged from 1.0 to 21% and the main contributions were due the counting statistics of sample and pipetted standards. For AAS, expanded uncertainties ranged from 6.5 to 13% and the main contributions were associated to the calibration curves. Uncertainty results were compared with the standard deviations of the mass fraction in the fishes (n = 10). Due to the wide variability in the mass fraction in the analyzed fish tissues, explained by factors such gender, age, fat content and fishing location of the specimens of each specie, standard deviations were greater than expanded uncertainties, which means that the natural variability of the elements determined is greater than the data dispersion associate

    Palavras-Chave: absorption spectroscopy; brazil; data covariances; elements; evaluation; fishes; neutron activation analysis; toxicity

  • IPEN-DOC 10666

    MIGLIAVACCA, E. ; ANDRADE, D.A. . Modelagem do poder de separacao de ultracentrifugas por regressao multivariada com matriz de covariancia. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE FISICA E REATORES THERMAL HIDRAULICA, 14th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: data covariances; experimental data; isotope separation; least square fit; optimization; ultracentrifuges; uranium

  • IPEN-DOC 24065

    BARROS, LIVIA F. ; DIAS, MAURO S. ; KOSKINAS, MARINA F. ; YAMAZAKI, IONE M. ; SEMMLER, RENATO . Preliminary measurements of k0 values for W-186. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: There are various methods of neutron activation analysis, one of these is the k0 Method for quantitative reactor Neutron Activation Analysis (NAA). The k0-NAA procedure is nowadays widely used in numerous laboratories performing NAA all over the world. Among these reactions, 186W(n, )187W can be considered important because it can be used for a W concentration measurements. The irradiations were performed at position 24A, near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP – Nuclear and Energy Research Institute), in São Paulo, Brazil. Two irradiations were carried out in sequence, using two sets of samples: the first with a cadmium cover around the samples and the second without, in a total of three data sets with and without Cd cover performed in 2014 and 2015. The activity measurements were carried out in an HPGe gamma-ray spectrometer. Standard sources of 152Eu, 133Ba, 60Co and 137Cs supplied by the IAEA were used in order to obtain the HPGe gamma-ray peak efficiency as a function of the energy. The covariance matrix methodology was applied to all uncertainties involved. The preliminary values of k0 for 186W(n, )187W reaction for the gamma transition energy of 479.53 keV was 3.17x10-2(5), for 618.77 keV was 9.08x10-3(15) and for 685.77 keV was 3.88x10-2(6). These preliminary values for k0 have been compared with the literature.

    Palavras-Chave: activity levels; cadmium; data covariances; high-purity ge detectors; neutron activation analysis; tungsten 186

  • IPEN-DOC 07764

    ULRICH, J.C. ; BUCHMANN, J.H. ; SARKIS, J.E.S. . Programa de qualidade em um laboratorio analitico de ultra-tracos. In: FROTA, M.N. (Ed.); CARMO, L.C.S. (Ed.) INTERNATIONAL CONFERENCE ON ADVANCED METROLOGY IN CHEMISTRY AND LABORATORY QUALITY; BRAZILIAN CONGRESS OF METROLOGY, 2nd; INTER-AMERICAN CONGRESS ON METROLOGY IN CHEMISTRY, 2nd; NATIONAL MEETING OF ACCREDITED LABORATORIES, 2nd, Dec. 4-7, 2000, Sao Paulo, SP. Proceedings... 2000. p. 518-528.

    Palavras-Chave: quality control; laboratories; chemical analysis; isotope ratio; trace amounts; elements; data covariances

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.