Navegação Eventos - Artigos por assunto "kerma"

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 24057

    FONTES, LADYJANE P. ; POTIENS, MARIA da P.A. . Application of the correction factor for radiation quality Kq in dosimetry with pencil-type ionization chambers using a tandem system. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 22-27, 2017, Belo Horizonte, MG. Proceedings... Rio de Janeiro, RJ: Associação Brasileira de Energia Nuclear, 2017.

    Abstract: The pencil-type ionization chamber widely used in computed tomography (CT) dosimetry, is a measuring instrument that has a cylindrical shape and provides uniform response independent of the angle of incidence of ionizing radiation. Calibration and measurements performed with the pencil-type ionization chamber are done in terms of Kerma product in air-length (Pk,l) and values are given in Gy.cm. To obtain the values of (Pk,l) during clinical measurements, the readings performed with the ionization chamber are multiplied by the calibration coefficient (Nk,l) and the correction factor C for quality (Kq) which are given in Calibration certificates of the chambers. The application of the correction factor for radiation quality Kq is done as a function of the effective energy of the beam that is determined by the Half Value layer (HVL) calculation. In order to estimate the HVL values in this work, a Tandem system made up of cylindrical aluminum and PMMA absorber layers was used as a low cost and easy to apply method. From the Tandem curve, it was possible to construct the calibration curve and obtain the appropriate Kq to the beam of the computed tomography equipment studied.

    Palavras-Chave: calibration; computerized tomography; corrections; dosimetry; ionization chambers; kerma; layers; pmma; quality assurance

  • IPEN-DOC 20607

    BATISTA, WILSON O.; SOARES, MARIA R.; OLIVEIRA, MARCUS V.L. de; MAIA, ANA F.; CALDAS, LINDA V.E. . Assessment of protocols in CBCT with symmetric and asymmetric beam using effective dose and Psub(KA). In: INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY , 14th, April 13-16, 2014, Cusco, Peru. Proceedings... 2014. p. 423-432.

    Palavras-Chave: dentistry; radiology; cat scanning; kerma; symmetry; images; jaw; phantoms; radiation doses; dose equivalents

  • IPEN-DOC 10630

    ALVAREZ, O.T.B.; CALDAS, L.V.E. . Avaliacao do desempenho de dos modelos de camaras poco utilizados em braquiterapia LDR. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: air; brachytherapy; calibration standards; cesium 137; cobalt 57; experimental data; ionization chambers; kerma; low dose irradiation; performance testing; radiation sources; technetium 99

  • IPEN-DOC 10701

    MIRANDA, J.A.; POTIENS, M.P.A. . Avaliacao dos valores de taxa de kerma no ar dos sistemas de radiacao X utilizados na calibracao de intrumentos de medida em radiodiagnostico. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; ENCONTRO NACIONAL DE APLICACOES NUCLEARES, 7th, ago. 28 - set. 2, 2005, Santos, SP. Anais... Sao Paulo: ABEN, 2005, 2005.

    Palavras-Chave: air; calibration standards; calibration; ionization chambers; kerma; quality assurance; radiation doses; radiation protection; radiation quality; x-ray equipment

  • IPEN-DOC 10439

    POTIENS, M.P.A. ; CALDAS, L.V.E. . Calibration methodology for instruments utilized in X radiation beams diagnostic level. In: INTERNATIONAL JOINT MEETING/CONGRESO INTERNACIONAL CONJUNTO, Jul. 11-14, 2004, Cancun, Quintana Roo, Mexico. Proceedings... 2004.

    Palavras-Chave: americium 241; calibration; diagrams; dosimetry; electric potential; experimental data; gamma radiation; high-purity ge detectors; ionization chambers; iso; kerma; measuring instruments; peaks; radiation protection; radiation quality; radiology; x radiation

  • IPEN-DOC 21410

    SILVA, NATALIA F. ; XAVIER, MARCOS ; VIVOLO, VITOR ; CALDAS, LINDA V.E. . Caracterização de uma camara de ionização de ar livre para baixas energias / Characterization of a free air ionization chamber for low energies. In: CONGRESSO BRASILEIRO DE METROLOGIA, 8., 29 de novembro - 4 de dezembro, 2015, Bento Gonçalves, RS. Anais... 2015.

    Palavras-Chave: ionization chambers; kerma; x-ray sources; beams

  • IPEN-DOC 13365

    AFONSO, L.C.; VIVOLO, V. ; CALDAS, L.V.E. . Characteristics of a tandem system of ionization chambers in X-ray beams mammography level. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 7th, June 22-27, 2008, Praga, Republica Tcheca. Proceedings... 2008.

    Palavras-Chave: biomedical radiography; dosemeters; dosimetry; ionization chambers; kerma; mammary glands; quality control; x radiation; x-ray equipment

  • IPEN-DOC 22367

    POTIENS JUNIOR, A.J. ; COSTA, N.A. ; SANTOS, L.R. ; CORREA, E.L.; VIVOLO, V. ; POTIENS, M.P.A. . Comparison of a KAP meter and a PDC behaviour using mathematical simulation in reference diagnostic radiology qualities. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 9th, July 6-11, 2014, Valencia, Espanha. Proceedings... 2014.

    Palavras-Chave: comparative evaluations; kerma; evaluation; measuring instruments; diagnosis; radiology; monte carlo method

  • IPEN-DOC 22369

    MARTINS, ELAINE W. ; POTIENS, MARIA da P.A. . Design and development of a pediatric phantom. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 9th, July 6-11, 2014, Valencia, Espanha. Proceedings... 2014.

    Palavras-Chave: design; construction; phantoms; surface air; kerma; comparative evaluations; patients; children; patients; children

  • IPEN-DOC 27083

    MARTINS, E.W. ; CARDOSO, J.V.; POTIENS, M.P.A. . Determination of computed tomography quantities using a new pediatric phantom. In: INTERNATIONAL CONFERENCE ON RADIATION PROTECTION IN MEDICINE: ACHIEVING CHANGE IN PRACTICE, December 11-15, 2017, Vienna, Austria. Proceedings... Vienna, Austria: International Atomic Energy Agency, 2018. p. 1-5.

    Abstract: A computed tomography pediatric head phantom that uses special materials to simulate the cortical and the cancellous bone was developed. This paper shows its behavior to determine the specific computed tomography radiation quantities at two calibration laboratory, the LCI-IPEN, Brazil and LMRI-IST, Portugal. The specific quantities measured were: air kerma index(Ca,100), weighted air kerma index (Cw), average volumetric air kerma index (Cvol) and the air kerma- lenght product (PKL). The reference radiation qualities used in both laboratories were the radiation qualities recommended by the norm IEC 61267 (RQT8, RQT9 e RQT10) to computed tomography dosimetry measurements. The calculated values of CW show attenuation of 11%, 13% and 10% for the qualities RQT 8, RQT 9 and RQT 10, respectively, from cortical to cancellous bone.

    Palavras-Chave: phantoms; pediatrics; computerized tomography; kerma

  • IPEN-DOC 18539

    MARTINS, ELAINE W.; POTIENS, MARIA da P.A. . Determination of specific CT quantities in standard beams using phantoms. In: SYMPOSIUM ON RADIATION MEASUREMENTS AND APPLICATIONS, May 14-17, 2012, Oakland, USA. Proceedings... 2012.

    Palavras-Chave: computerized tomography; dosimetry; calibration; ionization chambers; phantoms; kerma; radiation doses

  • IPEN-DOC 20424

    BARREIRA, J.S.; VIVOLO, V. . Determination of the tube voltage from clinic mammographic system using two types of detectors. In: CONGRESSO DE PROTEÇÃO CONTRA RADIAÇÕES DA COMUNIDADE DE PAISES DE LÍNGUA PORTUGUESA, 4.; CONGRESSO INTERNACIONAL DE RADIOPROTEÇÃO INDUSTRIAL, 6.; ENCONTRO DE PROTEÇÃO RADIOLÓGICA DO CONE SUL, 1.; CONGRESSO BRASILEIRO DE PROTEÇÃO RADIOLÓGICA, 4., August 26-29, 2014, Gramado, RS. Proceedings... 2014.

    Palavras-Chave: diagnostic techniques; mammary glands; neoplasms; calibration; air; kerma; electric currents; x-ray tubes; radiation doses; radiation detectors; radiation quality

  • IPEN-DOC 22370

    COSTA, N. ; POTIENS, M. . Development of a calibration methodology and tests of kerma area product meters. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATION, 9th, July 6-11, 2014, Valencia, Espanha. Proceedings... 2014.

    Palavras-Chave: calibration; diagnosis; dosemeters; kerma; meters; patients; quality control; radiation doses; radiology

  • IPEN-DOC 18554

    COSTA, N.A.; POTIENS, M.P.A. . Development of a calibration methodology of the patient dose calibrator. In: INTERNATIONAL CONFERENCE ON RADIATION IN MEDICINE, December 3-7, 2012, Bonn, Germany. Proceedings... 2012.

    Palavras-Chave: diagnostic techniques; radiology; calibration; kerma; meters; radiation doses; dosemeters; patients

  • IPEN-DOC 18542

    COSTA, NATHALIA A.; POTIENS, MARIA da P.A. . Development of a quality control program of the patient dose calibrator. In: CONGRESSO BRASILEIRO DE FÍSICA MEDICA, 17., 8-11 de agosto, 2012, Salvador, BA. Anais... 2012.

    Palavras-Chave: diagnostic techniques; x radiation; radiation doses; patients; kerma; calibration; quality control; performance

  • IPEN-DOC 26132

    PRIMO, CAMILA de O. ; ANGELOCCI, LUCAS V. ; KARAM JUNIOR, DIB; ZEITUNI, CARLOS A. ; ROSTELATO, MARIA E.C.M. . Dose-rate constant and air-kerma strength evaluation of a new 125-I brachytherapy source using Monte-Carlo. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE, October 21-25, 2019, Santos, SP. Proceedings... Rio de Janeiro: Associação Brasileira de Energia Nuclear, 2019. p. 167-174.

    Abstract: Brachytherapy is a modality of radiotherapy which treats tumors using ionizing radiation with sources located close to the tumor. The sources can be produced from several radionuclides in various formats, such as Iodine-125 seeds and Iridium-192 wires. In order to produce a new Iodine-125 seed in IPEN/CNEN and ensure its quality, it is essential to describe the dosimetry of the seed, so when applied in a treatment the lowest possible dose to neighboring healthy tissues can be reached. The report by the AAPM’s Task Group 43 U1 is a document that indicates the dosimetry procedures in brachytherapy based on physical and geometrical parameters. In this study, dose-rate constant and air-kerma strength parameters were simulated using the Monte Carlo method radiation transport code MCNP4C. The air-kerma strength is obtained from an ideal modeled seed, since its actual value should be measured for seeds individually in a specialized lab with a Wide-Angle Free-Air Chamber (WAFAC). Dose-rate constant and air-kerma strength are parameters that depends on intrinsic characteristics of the source, i.e. geometry, radionuclide, encapsulation, and together they define the dose-rate to the reference point, defined as the dose-rate to a point 1 cm away from the geometric center of the source, in its transverse plane. This study presents the values found for these parameters with associated statistical uncertainty, and is part of a larger project that aims the full dosimetry of this new seed model, including experimental measures.

    Palavras-Chave: brachytherapy; computerized simulation; dose rates; dosimetry; iodine 125; kerma; monte carlo method

  • IPEN-DOC 20653

    SOARES, M.R.; BATISTA, W.O.G.; MAIA, A.F.; CALDAS, L.V.E. ; LARA, P.A.. Effective dose comparison between protocols stitched and usual protocols in dental CBCT for complete arcade. In: INTERNATIONAL SYMPOSIUM ON SOLID STATE DOSIMETRY, 14th, April 13-16, 2014, Cusco, Peru. Proceedings... 2014. p. 433-442.

    Palavras-Chave: dentistry; radiology; phantoms; radiation doses; kerma; thermoluminescent dosimetry; simulators; computerized tomography

  • IPEN-DOC 27609

    XAVIER FILHO, JOEL M. ; SILVEIRA, IURY S. ; CALDAS, LINDA V.E. . Espectros de feixes padrões de radiação X nas qualidades de radiodiagnóstico e mamografia a partir de simulações Monte Carlo. In: CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIAÇÕES IONIZANTES, 7., 23-25 de novembro, 2020, Online. Anais... Rio de Janeiro, RJ: Sociedade Brasileira de Metrologia, 2020. p. 1-9.

    Abstract: Foram simulados os seis feixes RQR 5, 8, M1, M2, M3 e M4 descritos na norma TRS-457 (IAEA) utilizando o código de Monte Carlo EGSnrc. Foram realizadas simulações computacionais de um tubo de raios X para a obtenção de seus espectros utilizando o software BEAMnrc. As curvas de atenuação para cada espectro foram obtidas com o aplicativo egs_kerma. Por meio das 1ª e 2ª camadas semi-redutoras, dos coeficientes de homogeneidade e das energias médias foi possível determinar a qualidade de cada um dos feixes simulados. Todos os parâmetros de qualidade foram próximos aos estabelecidos na norma TRS-457 (IAEA).

    Palavras-Chave: beams; computer codes; computerized simulation; kerma; monte carlo method; quality control; standards

  • IPEN-DOC 18743

    VIVOLO, VITOR ; NEVES, LUCIO P. ; PERINI, ANA P. ; CALDAS, LINDA V.E. . Establishment of the practical peak voltage for standard computed tomography radiation qualities at a Calibration Laboratory. In: INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, 13th, May 13-18, 2012, Glasgow, Scotland. Proceedings... 2012.

    Palavras-Chave: brazilian cnen; laboratories; dosemeters; radiation detectors; calibration; computerized tomography; voltmeters; kerma; meters; x radiation

  • IPEN-DOC 12127

    POTIENS, MARIA P.A. ; FRANCISCATTO, PRISCILA C.; MIRANDA, JUREMA A. de. Evaluation of an ionization chamber response with different phantoms in diagnostic radiology fields. In: INTERNATIONAL NUCLEAR ATLANTIC CONFERENCE; MEETING ON NUCLEAR APPLICATIONS, 8th/ MEETING ON REACTOR PHYSICS AND THERMAL HYDRAULICS, 15th, Sept. 30 - Oct. 5, 2007, Santos, SP. Proceedings... Sao Paulo: ABEN, 2007, 2007.

    Palavras-Chave: air; calibration; diagnostic techniques; distance; ionization chambers; kerma; phantoms; radiation quality; radiology; x radiation

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.