Navegação Eventos - Resumos por Autores IPEN "ALENCAR, M.C."
-
MICELLI, A.L.
; MUCSI, C.S.
; ROSSI, J.L.
; ARANHA, L.C.
; ALENCAR, M.C.
; BOTTREL, J.; ANGELO, M.B.; ZAGNI, R.F.; RANGEL, E.T.
; NIGRO, F.
.
Analysis of the tensile strength of straight and angled abutments in narrow diameter implants.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 3885-3885.
Abstract:
Despite the success of osseointegrated implants, some biomechanical problems, such
as loosening or fracture of the abutment, crown fixation screw loosening and prosthetic
instability, are common problems reported in the literature. Thus, the objective of the
present study was to analyse the tensile strength of straight and angled abutments in
narrow diameter implants installed by means of friction. The specimen was composed
of an implant of 3.3x11mm fixed 2 mm above of a resin block. The abutments were
fixed by friction receiving 3, 5 and 7 beats along the implant axis, and were positioned
with 0, 10 and 20 degrees of angulation. The abutments were subjected to tensile
force, totalizing 10 repetitions for each test. The results showed higher values of
removal strength for the abutments with 7 beats, and no statistical difference with 5
beats suggesting better mechanical stability.
MICELLI, A.L.; MUCSI, C.S.; ROSSI, J.L.; ARANHA, L.C.; ALENCAR, M.C.; BOTTREL, J.; ANGELO, M.B.; ZAGNI, R.F.; RANGEL, E.T.; NIGRO, F.
Analysis of the tensile strength of straight and angled abutments in narrow diameter implants.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 3885-3885.
Disponível em: http://repositorio.ipen.br/handle/123456789/29532. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
BOTTREL, J.S.; MUCSI, C.S.
; ROSSI, J.L.
; ARANHA, L.C.
; ANGELO, M.B.; ALENCAR, M.C.
; ZAGNI, R.F.; MICELLI, A.L.
; LEITE, D.M.C.
; RANGEL, E.T.
.
Análise morfológica das roscas dos implantes odontológicos.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 3972-3972.
Abstract:
O objetivo da pesquisa foi avaliar a morfologia dos implantes dentários, sua
macrogeometria, diante do torque de inserção em ossos sintéticos tipo I e IV. A
biomecânica de um implante dental está intimamente ligado às partes constituintes,
ou estruturas que compõem o implante, conhecidas como desenho ou geometria. As
roscas dos implantes são usadas para agir como ferramenta de corte, para a
construção da rosca no osso e; aumentar a sua estabilidade inicial, maximizar o
contato entre o osso e o implante, e direcionar para uma melhor dissipação das cargas
oclusais. Portanto, a análise do passo da rosca, a geometria da rosca, o ângulo da
hélice, a profundidade da rosca e a largura, bem como o módulo da crista do implante
são alguns dos vários padrões geométricos que determinam a superfície funcional da
rosca e afetam na distribuição das cargas biomecânicas nos implantes.
Caracterização das roscas, por microscopias ótica, eletrônica e metrologia. Para
avaliação dos esforços de inserção dos implantes nos ossos foi utilizado um micro
torquímetro, simulando a prática clínica, mas com um sistema de aquisição de dados
que permitiu a analisar a evolução temporal dos esforços de inserção dos implantes.
Os resultados obtidos indicam como a geometria da rosca afeta a distribuição das
forças de sobrecarga mecânica em torno do implante. Menor passo de rosca pode
influenciar positivamente a estabilidade do implante. O excesso de ângulos de hélice,
apesar de uma inserção mais rápida, pode comprometer a capacidade dos implantes
de sustentar a carga axial. Os segmentos mais profundos parecem ter um efeito
importante na estabilização em situações mais precárias de qualidade óssea.
Aumento do número de fio no módulo da crista de um implante pode fornecer um
melhor contato do osso para o implante, preservando osso marginal.
BOTTREL, J.S.; MUCSI, C.S.; ROSSI, J.L.; ARANHA, L.C.; ANGELO, M.B.; ALENCAR, M.C.; ZAGNI, R.F.; MICELLI, A.L.; LEITE, D.M.C.; RANGEL, E.T.
Análise morfológica das roscas dos implantes odontológicos.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 3972-3972.
Disponível em: http://repositorio.ipen.br/handle/123456789/29535. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
NIGRO, F.
; ROSSI, J.L.
; MUCSI, C.S.
; SATURNINO, P.; BARBOSA, B.A.; ARANHA, L.C.
; MICELLI, A.L.
; ALENCAR, M.C.
.
Avaliação dos desgastes das fresas após diversas utilizações nas perfurações ósseas para instalação de implantes dentais.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5400-5400.
Abstract:
A utilização dos implantes osseointegrados trouxe uma nova realidade nas
reabilitações orais, uma vez que estes irão substituir as raízes dos dentes ausentes
para a confecção de um novo dente. Para se obter sucesso na instalação destes
implantes e consequentemente na osseointegração e na longevidade deste implante
em função, diversos aspectos devem ser observados, dentre estes um dos principais
é a confecção do alvéolo cirúrgico. Nessa fase a região óssea que irá receber o
implante passará por uma sequência de fresagens, de tal maneira a ir-se ampliando
progressivamente e gradativamente o osso até se atingir o diâmetro e o comprimento
desejado para a instalação do implante. Na realização deste ato cirúrgico diversas
fresas são usadas sucessivamente. Durante este ato cirúrgico também se deve utilizar
de uma irrigação abundante. Estes fatores são importantes para que durante a
fresagem do osso não ocorra um aquecimento excessivo deste, uma vez que é sabido
que não se pode exceder a 47 °C, pois temperaturas acima podem gerar uma necrose
óssea e consequentemente interferir ou até mesmo inviabilizar o processo de
osseointegração. Dentre estes cuidados a utilização das fresas são de fundamental
importância, pois estas sofrem desgastes com o uso sucessivo. A recomendação tem
sido de utilizar-se estas para aproximadamente 20 perfurações. Mediante o exposto o
presente trabalho teve o objetivo de avaliar os desgastes ocorridos na superfície das
fresas, bem como se houve algum dano da cobertura de DLC (diamond like carbon).
Foram realizadas 50 perfurações, com cada fresa, em costela bovina, seguindo-se a
sequência recomendada para a instalação de implantes com 4 mm de diâmetro e
13mm de profundidade. Foram feitos dois grupos. No grupo G1 utilizou-se as fresas
sem irrigação e no grupo G2 utilizou-se as fresas com irrigação. Para cada grupo
foram feitas 3 sequências de fresagens. Após essa etapa as fresas foram observadas
em MEV (microscopia eletrônica de varredura) e também em microscopia óptica - MO.
Observou-se que estas sofrem um arredondamento nos ângulos de corte e que em
alguns pontos ocorre o arrancamento da camada DLC. Estes achados podem ser
sugestivos que a utilização de fresas já desgastadas podem gerar um aquecimento
acima do desejado. Esses achados implicam que as fresas devam ser substituídas,
após uma quantidade de fresagens sugeridas entre 25 e 30 vezes, a fim de não se
comprometer a osseointegração durante esse procedimento.
NIGRO, F.; ROSSI, J.L.; MUCSI, C.S.; SATURNINO, P.; BARBOSA, B.A.; ARANHA, L.C.; MICELLI, A.L.; ALENCAR, M.C.
Avaliação dos desgastes das fresas após diversas utilizações nas perfurações ósseas para instalação de implantes dentais.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5400-5400.
Disponível em: http://repositorio.ipen.br/handle/123456789/29579. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ANGELO, M.B.; MUCSI, C.S.
; ROSSI, J.L.
; ARANHA, L.C.
; BOTTREL, J.; MICELLI, A.L.
; ALENCAR, M.C.
; TAKEDA, E.
; NIGRO, F.
; LEITE, D.M.C.
.
Caracterização morfológica de membrana polimérica em duas gramaturas distintas.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 7151-7151.
Abstract:
Regenerações ósseas maxilares, são procedimentos onde o cirurgião dentista
reconstrói cirurgicamente uma falha óssea gerada por um trauma causado por um
acidente, por cirurgias pregressas como extrações dentárias, pela perda óssea
crônica devido a má higiene bucal durante a vida do paciente ou até mesmo por lesões
que acometeram a estrutura óssea dessas regiões maxilares. Biomateriais sintéticos,
cada vez mais são desenvolvidos para auxiliar nessas regenerações, evitando assim
a utilização de materiais que apresentam maiores riscos e morbidades aos pacientes.
Um exemplo de biomaterial que possui características interessantes é a membrana
polimérica. A membrana atua como barreira seletiva, impedindo a migração de células
epiteliais e tecido gengival, para a área contendo biomaterial. promovendo a
manutenção do arcabouço ósseo, mantendo assim melhores condições para que
possa ocorrer a formação de novo tecido ósseo e assim uma melhor reparação da
área afetada. A membrana é composta de copolímeros de PLGA 85/15, (poli lactatoco-
poli glicolato) um polímero biodegradável utilizado há anos na indústria médica,
juntamente ao PLGA, a membrana contem também fosfatos de cálcio na forma de
Hidróxiapatita e BTCP. Estes fosfatos são convertidos em novo tecido ósseo por
células especializadas (osteoblastos), sendo absorvidos pelo corpo humano. Eles
também auxiliam no processo de adesão celular por parte dos osteoblastos, gerando
um ambiente mais favorável para o crescimento e formação de novo tecido ósseo.
Visando a melhor indicação clínica da odontologia, principalmente na implantodontia
auxiliando nas regenerações ósseas, o objetivo desse trabalho é a caracterização
morfológica através do microscópio eletrônico de varredura (MEV) de uma membrana
polimérica com 2 diferentes gramaturas, 500 micrometros e 700 micrometros
respectivamente, em desenvolvimento por uma empresa nacional. A estrutura macro
e micro foi analisada, notando-se a malha polimérica formada pelo PLGA e a presença
dos grânulos de hidroxiapatita e BTCP em ambas amostras. Não foram observadas
morfologicamente diferenças na rede polimérica do PLGA, nem nos grânulos de
hidroxiapatita e BTCP adicionados ao polímero, nas amostras das duas gramaturas
distintas. Apesar da caracterização morfológica através do microscópio eletrônico de
varredura (MEV) ser de grande importância para o seguinte estudo, outros ensaios
devem ser realizados para uma melhor caracterização do biomaterial, como
hidrofilicidade, ensaio de tração, teste de degradação e área de superfície.
ANGELO, M.B.; MUCSI, C.S.; ROSSI, J.L.; ARANHA, L.C.; BOTTREL, J.; MICELLI, A.L.; ALENCAR, M.C.; TAKEDA, E.; NIGRO, F.; LEITE, D.M.C.
Caracterização morfológica de membrana polimérica em duas gramaturas distintas.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 7151-7151.
Disponível em: http://repositorio.ipen.br/handle/123456789/29659. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MUCSI, C.S.
; ROSSI, J.L.
; NOGUEIRA, E.J.
; ARANHA, L.C.
; JESUS, E.R.B.
; ALENCAR, M.C.
.
Characterization of the implant-abutment interface with a dynamic microtorquemeter.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 22.,
06-10 de novembro, 2016,
Natal, RN.
Abstract...
2016.
p. 5719.
Abstract:
The insertion of odontological implants as well as its abutments represent an important factor to the components performance in patient oral rehabilitation. This work presents the efforts in the characterization of the interfaces between implant and abutment of two different families of implants with the use of a specifically developed microtorquimeter. A set of tests were performed torqueing the abutment into the implant with subsequent detorqueing. The strain caused on the microtorquimeter torque bar were recorded in a myDAQ National Instruments equipment and then processed and analysed in order to identify signatures on the signal and relate them to mechanical behavior of the interfaces. Results indicate an important difference between the signals of the two families and lead the authors to identify possible failures in performance related to them.
MUCSI, C.S.; ROSSI, J.L.; NOGUEIRA, E.J.; ARANHA, L.C.; JESUS, E.R.B.; ALENCAR, M.C.
Characterization of the implant-abutment interface with a dynamic microtorquemeter.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 22.,
06-10 de novembro, 2016,
Natal, RN.
Abstract...
2016.
p. 5719.
Disponível em: http://repositorio.ipen.br/handle/123456789/27250. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ALENCAR, M.C.
; CIONE, F.C.
; REIS, L.A.M.
; MUCSI, C.S.
; SOUZA, M.M.; ROSSI, J.L.
; ARANHA, L.C.
.
Comparative study on extensômetria and finite element simulation for deformation for torsion.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6380-6380.
Abstract:
The use of finite element simulation has been widely employed by industry and
academia, for design and development of mechanical systems; and with that there's a
considerable savings in time, financial and manpower. In this project we will be
evaluating and comparing the results of the behavior of a piece by computer simulation
by finite elements, using the software Ansys ® Academic, for a bar with strain
concentration profile, where this will be applied to twist. With the results of the
simulations, compared with the results of the same piece materialized and with
installation of strain gages to measure the deformation exerted on the. These sensors
convert the mechanical deformation in electrical signal by formation of a Wheatstone
bridge. In this way, with the results of the two reviews, simulation and measurement,
we note that there is similarity between the results, Since we work within the
component's elastic deformation curve.
ALENCAR, M.C.; CIONE, F.C.; REIS, L.A.M.; MUCSI, C.S.; SOUZA, M.M.; ROSSI, J.L.; ARANHA, L.C.
Comparative study on extensômetria and finite element simulation for deformation for torsion.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6380-6380.
Disponível em: http://repositorio.ipen.br/handle/123456789/29609. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ALENCAR, M.C.
; MUCSI, C.S.
; GOMES, C.D.; REIS, L.A.M.
; SOUZA, M.M.; ROSSI, J.L.
.
Development of primary system for calibration of torque measuring instruments.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6247-6247.
Abstract:
The importance of torque measurement is already known in the academic, scientific
and industrial, but the reliability of these measurements can be questioned when the
equipment has no calibration. That's why the periodic calibration of such equipment is
essential to ensure that the measurements that will be performed on this instrument
are trusted. With that comes the proposal of building a device for calibration of torque
measuring instruments, where we had the premise of the development of a primary
system torque generation, so that we can calibrate torque measuring instruments of
any class of accuracy. The development followed mechanical and geometrical
construction standards to ensure the best design and balance between the positions
of load application. In conjunction with torque application system was scaled and
constructed a set of calibrated masses, He served as charge for applying torque, so
we can define precisely the value of the torque to be applied.
ALENCAR, M.C.; MUCSI, C.S.; GOMES, C.D.; REIS, L.A.M.; SOUZA, M.M.; ROSSI, J.L.
Development of primary system for calibration of torque measuring instruments.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6247-6247.
Disponível em: http://repositorio.ipen.br/handle/123456789/29605. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MUCSI, C.S.
; ROSSI, J.L.
; ALENCAR, M.C.
; REIS, L.A.M.
; ROSSI, A.C.
.
Uma discussão sobre a aeroelasticidade de quadricópteros não tripulados, drones, oferecendo subsídios para projetos.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6986-6986.
Abstract:
Os veículos aéreos não tripulados vem ganhando grande notoriedade, face à ampla
gama de suas aplicações científicas e tecnológicas. Estes apresentam construções
tão simples como brinquedos até equipamentos com altíssimo valor técnico científico
agregado, destinados à missões relevantes. O presente trabalho visa apresentar uma
discussão sobre a aeroelasticidade destes equipamentos na escala métrica, assunto
árido e escasso nesta nova aeronáutica. São apresentados resultados de simulações
numéricas relacionando o comportamento dos componentes estruturais em função
dos esforços mecânicos, mormente os relacionados à mudança de atitude do
equipamento, rotações e inclinações. Os resultados obtidos indicam a necessidade
de cuidado e atenção no projeto dos braços dos quadcópteros, com especial atenção
às suas seções transversais e à raiz do braço, na junção com o corpo; para evitar
instabilidades que de outra maneira sobrecarregariam o processador do estabilizador
de vôo. Estes dados estão servindo de base para o projeto e construção de um
equipamento voltado à detecção e localização de fontes radioativas.
MUCSI, C.S.; ROSSI, J.L.; ALENCAR, M.C.; REIS, L.A.M.; ROSSI, A.C.
Uma discussão sobre a aeroelasticidade de quadricópteros não tripulados, drones, oferecendo subsídios para projetos.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6986-6986.
Disponível em: http://repositorio.ipen.br/handle/123456789/29623. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
VIVEIROS, B.V.G. de
; ALENCAR, M.C.
; BERBEL, L.O.
; DONATUS, U.
; COSTA, I.
.
Estudo da resistência à corrosão das ligas AA2050-T84 e AA7050-T7451 soldadas por FSW.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5003-5003.
Abstract:
As ligas de alumínio da série 2XXX e 7XXX são muito utilizadas comercialmente em
indústrias aeronáuticas pela presença de boas características como resistência à
corrosão, resistência mecânica e baixa densidade. Porém, quando soldadas, suas
microestruturas sofrem mudanças, o que altera suas propriedades. Neste estudo, as
ligas 2XXX e 7XXX foram soldadas pelo método de fricção e mistura, também
conhecido como “friction stir welding” (FSW), que aquece e quebra os grãos pela
tensão aplicada resultando na soldagem no estado sólido das duas ligas. Neste
estudo a resistência à corrosão das ligas AA2050-T84 e AA7050-T7451 soldadas por
FSW foi investigada pela técnica “Scanning Vibrating Electrode Technique” (SVET), e
por “Scanning Ion - Electrode Technique” (SIET), em que foi realizada a medição de
pH localizado. O eletrólito usado neste estudo foi composto por 5 mM de NaCl sendo
que a região analisada da solda foi a secção transversal. As zonas afetadas pelo
processo FSW são apresentadas e caracterizadas a partir do tamanho de grãos
existentes, como metal base (MB), zona termicamente afetada (ZTA), zona
termomecanicamente afetada (ZTMA), zona de transição da zona
termomecanicamente afetada das ligas (ZTMA trans) e a zona de mistura (ZM), que
é a área de recristalização dos grãos. Foram também realizados ensaios de potencial
de circuito aberto (OCP) e impedância eletroquímica (EIS) nas mesmas regiões
observadas e ensaiadas dos ensaios anteriores, também com solução de 5 mM de
NaCl. Os resultados mostraram que nas primeiras horas de ensaio, a área mais
suscetível ao ataque foi a zona de transição das ligas (ZTMA trans), mas após 24 h
de ensaio, a zona mais suscetível foi a ZTMA da liga 7050-T7451. Esses resultados
foram correlacionados com a microestrutura das diferentes zonas.
Palavras-Chave:
aluminium alloys;
corrosion resistant alloys;
welding;
friction welding;
electrodes;
electrolytes;
ph value
VIVEIROS, B.V.G. de; ALENCAR, M.C.; BERBEL, L.O.; DONATUS, U.; COSTA, I.
Estudo da resistência à corrosão das ligas AA2050-T84 e AA7050-T7451 soldadas por FSW.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5003-5003.
Disponível em: http://repositorio.ipen.br/handle/123456789/29564. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MUCSI, C.S.
; NOGUEIRA, E.J.
; ROSSI, J.L.
; ALENCAR, M.C.
; JESUS, E.R.B.
; ANDRADE AMORIN, T.C. de
.
Project and construction of an automated control for a laboratory var furnace.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 22.,
06-10 de novembro, 2016,
Natal, RN.
Abstract...
2016.
p. 7667.
Abstract:
The quality of an alloy is intrinsically connected to the melting environment and the stability of the melting conditions. This is specially true when dealing with aerospace and nuclear oriented alloys. This work present the efforts in the development of an automated control system for the operation of a laboratory scale VAR (Vacuum Arc Remelting) furnace to be used in the melting o zirconium alloys. An automated control was devised using micro controllers to control electrode position to keep a constant electric arc length despite variations in the electrode consumption. The operation of the furnace was recorded by means of data acquisition system in order to analyse and keep track of the furnace parameters behaviour. Results show that the operation parameters were kept within the specified margins maintaining the furnace power well controlled.
MUCSI, C.S.; NOGUEIRA, E.J.; ROSSI, J.L.; ALENCAR, M.C.; JESUS, E.R.B.; ANDRADE AMORIN, T.C. de.
Project and construction of an automated control for a laboratory var furnace.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIENCIA DOS MATERIAIS, 22.,
06-10 de novembro, 2016,
Natal, RN.
Abstract...
2016.
p. 7667.
Disponível em: http://repositorio.ipen.br/handle/123456789/27258. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
MUCSI, C.S.
; ROSSI, J.L.
; ALENCAR, M.C.
; CIONE, F.C.
; SOUZA, M.M. de.
Projeto, construção e testes iniciais de dispositivo para ensaios de compressão com alta taxa de deformação – Hopkinson Bar.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6246-6246.
Abstract:
A caracterização mecânica de materiais tem importância fundamental no
desenvolvimento de produtos tecnológicos com melhor desempenho de engenharia
aliado a menores custos de produção final. Outrossim, oferece informações sobre o
material e permite a realização de projetos embasados em condições mais reais de
aplicação. Esta consideração aplica-se, especialmente aos projetos de subsistemas
veiculares e dos casques para o transporte de materiais radioativos. Com este objetivo
foi projetado um dispositivo tipo barra de Hopkinson, para a caracterização dinâmica
de metais, por compressão. Nestes dispositivos a aplicação da deformação dinâmica
é aplicada à amostra através de uma onda mecânica longitudinal deslocando-se por
barras de aço alinhadas; o comportamento das ondas que transitam pelo dispositivo
é registrado através de um sistemas de extensômetros e de um sistema eletrônico de
aquisição de dados; os dados adquiridos são então analisados quanto à dispersão, e
deformação da onda e, como resultado obtém-se a curva tensão-deformação,
associada à uma dada taxa de deformação da amostra. Neste trabalho foram
utilizados dois sistemas de aquisição de dados, com 50 kS/s e 2 GS/s e os resultados
são comparados, quanto aos custos envolvidos e à qualidade dos sinais obtidos. Os
dados obtidos para maiores taxas de aquisição apresentaram maior resolução, porém
os custos associados são bastantes mais elevados. Em contraponto, menores taxas
de aquisição exigem a utilização de extensômetros muito maiores, com menor custo,
mas com uma resolução no campo de frequências menor. São também apresentadas
discussões sobre as dimensões e posicionamento dos extensômetros.
MUCSI, C.S.; ROSSI, J.L.; ALENCAR, M.C.; CIONE, F.C.; SOUZA, M.M. de.
Projeto, construção e testes iniciais de dispositivo para ensaios de compressão com alta taxa de deformação – Hopkinson Bar.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6246-6246.
Disponível em: http://repositorio.ipen.br/handle/123456789/29602. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
REIS, L.A.M.
; ALENCAR, M.C.
; GOMES, M.P.
; PEREIRA, L.A.T.
; BARBOSA, L.P.
; MUCSI, C.S.
; ROSSI, J.L.
.
Recycling process viability from zirconium alloys scraps of lathe melted in the vacuum arc remelting (VAR) furnace.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5713-5713.
Abstract:
Pressurized water reactors (PWR) commonly use U235 enriched uranium dioxide
pellets as a nuclear fuel, these are assembled and cladded in zirconium alloy (M5,
Zirlo, Zircaloy) tubes and end caps. During the machining of these components, large
amounts of turning lathe chips are generated which are contaminated with cutting fluid.
Its storage presents safety and environmental risks due to its pyrophoric and reactive
nature. Recycling industry has shown interest in its recycling due to its strategic
importance of these scraps. This paper presents the steps on the recycling processes
and the results for the search of an efficient way on the cleaning, quality control,
manufacturing, and melting of electrodes for Vacuum Arc Remelting (VAR) furnace.
The process starts with cutting oil washout and this step consists of a water dissolution
followed by a degreasing process, the water rinse by continuous flow of water and
finally drying in hot air. Process evaluation was first made by means the X-ray
fluorescence tests in order to define the quality of the scraps that after washing were
pressed in 20 mm diameter briquettes, melted and subjected to such analysis. The
next step consists in the pressing with a die square section with 40 mm2 and 500 mm
long, producing an electrode with 20% of the Zircaloy bulk density. The electrode was
melted in a laboratory scale VAR furnace located at the CCTM – IPEN producing a 0.8
kg ingot. The microstructural and macro structural characterization is being done by
analyzes performed in the optical microscope and scanning electron microscope (from
portuguese Microscópio Eletronico de Varredura - MEV). Gas analyzes were carried
out with the intention of evaluating possible gases resulting from the melting and
evaluating their influence. X-ray diffraction analyzes were also performed to identify
the phases present in the material after the melting process The authors conclude that
the samples obtained from the fuel element industry can be melting in a VAR furnace
reducing 40 times the storage volume, however, it is necessary to remelt the ingots by
correcting their composition intended for reuse.
REIS, L.A.M.; ALENCAR, M.C.; GOMES, M.P.; PEREIRA, L.A.T.; BARBOSA, L.P.; MUCSI, C.S.; ROSSI, J.L.
Recycling process viability from zirconium alloys scraps of lathe melted in the vacuum arc remelting (VAR) furnace.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5713-5713.
Disponível em: http://repositorio.ipen.br/handle/123456789/29594. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
ALENCAR, M.C.
; REIS, L.A.M.
; MUCSI, C.S.
; SOUZA, M.M.; ARANHA, L.C.
; ROSSI, J.L.
.
Study development and characterization of micro torque transducer applied on screw elements analysis.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6245-6245.
Abstract:
The measurement of torque in threaded elements currently is an important step in
fixing of components, because knowing the torque applied can ensure the life of this
component, ensuring that the same will not be failed for lack of grip or excess. Micro
torque measurement to the control becomes more critical, Yes because working with
very low torques, until 1 N.m, It is necessary that the instrument has greater sensitivity
to be able to measure with accuracy required. The development of a micro torque
measurement system, where he studied and developed a micro torque transducer,
Since the design of the shaft and the design of the concentration of efforts, using the
help of the software of computer simulation by finite element analysis Ansys Academic,
to ensure that this work on elastic and with a uniform distribution of forces in the
specified region. After the shaft machining, was installed as sensor element four
precision strain gage, to form a wheatstone bridge, where converted to mechanical
tension due to the torque generated in electrical signal. Being possible to correlate the
mechanical deformation in ?? with the electrical signal generated in mV/V. With this
micro torque transducer mounted the metrological characterization, defined its
properties and measurement accuracy. From the statistical evaluation of the results
obtained during the tests, it was possible to quantify the uncertainty of measurement
for the transducer, that can be used in further work carried out in this equipment.
ALENCAR, M.C.; REIS, L.A.M.; MUCSI, C.S.; SOUZA, M.M.; ARANHA, L.C.; ROSSI, J.L.
Study development and characterization of micro torque transducer applied on screw elements analysis.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 6245-6245.
Disponível em: http://repositorio.ipen.br/handle/123456789/29601. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
-
COUTO, C.P.
; COSTA, I.
; VIVEIROS, B.G. de
; ALENCAR, M.C.
; PANOSSIAN, Z.; ROSSI, J.L.
; COLOSIO, M.A..
The use of scanning vibrating electrode technique to evaluate the effect of hot stamping on corrosion resistance of press hardened steel 22MnB5 metallic coated with electroplated ZnNi.
In: CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5149-5149.
Abstract:
The carmakers and all their production chain must achieve worldwide targets of
lightweight, safety and reduced fuel consumption. The use of ultra high strength steel,
such as press-hardened steels (PHS), in vehicle structures has been contributing with
this. This type of steel is widely used in hot stamping process, which consists in heating
the steel blank to the total austenitization temperature, and then transferring it from the
furnace into the die where the steel is deformed and quenched at the same time, with
a minimum cooling rate of 27 K/s. The boron-manganese PHS steel comprises perlite
and ferrite microstructure, and its tensile strength is around 600 MPa in the annealed
condition. Thus, after the hot stamping process the PHS microstructure completely
changes to martensite and the tensile strength increases to 1500 MPa or more. The
transferring step is a critical one, due to the contact of the hot steel blank with the
atmospheric air; as consequence, it causes the steel oxidation. To avoid that, the steel
is protected with metallic coatings. The hot-dip AlSi is the most currently used coating
for this application, however, in order to keep up with the high PHS demand, alternative
coatings, like zinc-base is under investigation. This work had the objective of evaluating
the corrosion resistance of PHS, 22MnB5 grade, coated with electroplated ZnNi before
and after hot stamping, using scanning vibrating electrode technique (SVET). The
corrosion-localized techniques are more suitable, once the results showed that after
hot stamping the coating layer changes completely, as a result of chemical elements
diffusion. Thus, different phases of Zn-Fe-Ni are formed and random distributed which
impacts the corrosion resistance of the steel.
Palavras-Chave:
corrosion resistance;
surface coating;
steels;
ferrite;
scanning electron microscopy;
perlite;
hardening;
pressing;
zinc;
nickel;
coatings
COUTO, C.P.; COSTA, I.; VIVEIROS, B.G. de; ALENCAR, M.C.; PANOSSIAN, Z.; ROSSI, J.L.; COLOSIO, M.A.
The use of scanning vibrating electrode technique to evaluate the effect of hot stamping on corrosion resistance of press hardened steel 22MnB5 metallic coated with electroplated ZnNi.
In:
CONGRESSO BRASILEIRO DE ENGENHARIA E CIÊNCIA DOS MATERIAIS, 23.,
04-08 de novembro, 2018,
Foz do Iguaçu, PR.
Resumo...
2018.
p. 5149-5149.
Disponível em: http://repositorio.ipen.br/handle/123456789/29567. Acesso em: $DATA.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.
Como referenciar este item
Buscar no repositório
Navegar
-
Todo o repositório
-
Esta coleção
Minha conta
Visualizar
A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.
✔ É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do
Buscar no Repositório
, isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.
✔ A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em
Navegar
✔ Os filtros disponíveis em
Navegar
tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro,
Autores IPEN
apresenta uma relação com os autores vinculados ao IPEN; o
ID Autor IPEN
diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome;
Tipo de acesso
diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.
A opção
Busca avançada
utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.
Exemplo:
Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.
Autor: Maprelian
Título: loss of coolant
Tipo de publicação: Texto completo de evento
Ano de publicação: 2015
✔ Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da
International Atomic Energy Agency – IAEA
, por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.
✔ 95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o
significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN,
bibl@ipen.br
.
✔ Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.
✔ O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.
✔ Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo
será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.
✔ Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).
ATENÇÃO!
ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI,
clique aqui.
2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI,
clique aqui.
O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.
Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.
A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.
O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.