Navegação Eventos - Resumos por Autores IPEN "RAELE, MARCUS P."

Classificar por: Ordenar: Resultados:

  • IPEN-DOC 25015

    SILVA, ANDRE F. ; COSTA, PRISCILA ; MACHADO, NOE G.P. ; SAMAD, RICARDO E. ; ZEZELL, DENISE M. ; RAELE, MARCUS P. ; ZAMATARO, CLAUDIA B. . Analysis of temperature on microscope slide by a boron pulsed laser deposition process. In: ENCONTRO DE OUTONO, 41., 06-11 de maio, 2018, Foz do Iguaçu, PR. Resumo... São Paulo: Sociedade Brasileira de Física, 2018. p. 1-1.

    Abstract: A boron thin ¯lm can be used for neutrons conversion and in electrically charged particles and further detection. Since boron has a high evaporation temperature and the thickness of the boron layer needs to have few microns, pulsed laser deposition also known as PLD can be used. When producing thin ¯lms with the PLD technique, the target absorbs energy promoting the material ablation creating a plasma plume that deposits material on a substrate, thus creating a thin ¯lm. Since all the deposition occurs in a vacuum chamber, the residual heat of the plasma that condensate at the substrate can build up, thus potentially source of concern if the substrate sensitive to temperature somehow. This work reports the analysis of the variation of temperature in a microscope slide (substrate) as a function of the energy of femtosecond laser pulses. For measuring the substrate temperature a type-K thermocouple was used together with associated electronics. The thermocouple was ¯xed to the back of substrate with thermal grease for vacuum and connected to the microchip using a feed through in the vacuum chamber. Was detected the increase of the substrate+¯lm starting at 6oC from initial temperature (room) for the minimal laser energy 100 microjoules (25 femtoseconds).

  • IPEN-DOC 16002

    AMARAL, MARCELLO M. ; RAELE, MARCUS P. ; LANDULFO, EDUARDO ; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. de . Application of LIDAR-like equations to OCT signal analysis for total extinction coefficient determination. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 33., 10-14 de maio, 2010, Aguas de Lindoia, SP. Resumos... 2010.

    Palavras-Chave: tomography; optical properties; interferometry; biological materials; animal tissues; diagnosis

  • IPEN-DOC 13819

    AMARAL, MARCELLO M. ; TARELHO, LUIZ V.G. ; RAELE, MARCUS P. ; FREITAS, ANDERSON Z. de ; VIEIRA JUNIOR, NILSON D. ; SANTOS JUNIOR, DARIO; KRUG, FRANCISCO. Bulk characterization of 'Estado Novo' coins by laser induced breakdown spectroscopy. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 31., Aguas de Lindoia, SP, 2008, 5-9 de maio. Resumo... 2008.

    Palavras-Chave: emission spectroscopy; energy; ion temperature; laser spectroscopy; laser-produced plasma; plasma production; plasma; qualitative chemical analysis; stark effect

  • IPEN-DOC 16001

    FREITAS, ANDERSON Z. de ; SUZUKI, LUIS C. ; PRATES, RENATO A. ; RAELE, MARCUS P. ; AMARAL, MARCELLO M. ; RIBEIRO, MARTHA S. . Candida albicans biofilm alterations during photodynamic therapy by optical coherence tomography video monitoring. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 33., 10-14 de maio, 2010, Aguas de Lindoia, SP. Resumos... 2010.

    Palavras-Chave: therapy; tomography; optical properties; candida; microorganisms; methylene blue; in vitro; photosensitivity

  • IPEN-DOC 13524

    FREITAS, ANDERSON Z. de ; RAELE, MARCUS P. ; VIEIRA JUNIOR, NILSON D. ; BABY, ANDRE R.; KANEKO, TELMA M.; VELASCO, MARIA V.R.. Caracterizacao da fibra capilar por tomografia de coerencia optica (OCT). In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 31., 5-9 de maio, 2008, Aguas de Lindoia, SP. Resumo... 2008.

    Palavras-Chave: hair; tomography; optical properties; in vitro

  • IPEN-DOC 26847

    COSTA, PRISCILA ; RAELE, MARCUS P. ; DOMIENIKAN, CLAUDIO ; COSTA, FABIO E. ; MADI FILHO, TUFIC ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . A compact electronic system for a photodiode neutron detector. In: JAKSIC, ALEKSANDAR (Ed.); KARAMARKOVIC, JUGOSLAV (Ed.) INTERNATIONAL CONFERENCE ON RADIATION APPLICATIONS, September 16-19, 2019, Belgrade, Serbia. Abstract... Niš, Serbia: Sievert Association, 2019. p. 36-36.

    Abstract: The demand for portable neutron detectors is on the rise, and for that purpose, low cost boron-10 has been frequently used instead of helium-3, which is usually employed in large and expensive detectors. Portable detectors are of interest in some applications, such as neutron dosimeters or inspection systems targeted in the detection of fissile material and drugs in airports. In this work a portable thermal neutron detection system was developed which is based on a commercial silicon photodiode coupled to a boron converter; this prototype is then plugged into a portable electronic system. The boron layer was produced by pulsed laser deposition, either on a thin glass slide or on the photodiode itself. The boron deposition in the photodiode was made directly in the active area of the detector, so before and after the deposition process a characterization of the device regarding both the dark current and the operation voltage was performed using an americium source. Finally, both configurations were tested. The neutron detection process occurs by detecting the alpha and lithium particles produced by the interaction of the incoming neutron with the boron-10 nuclides. These heavy ions then interact with the active area of the reverse-biased photodiode, producing an electric signal that has to be preamplified and then properly amplified by the portable electronic system, which in turn produces an output that can either be sent to a multichannel analyzer or to a digital counter. The integrated circuit of the low noise preamplifier transforms the detector’s current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy output pulse. The performance of the photodiode-amplifier set for alpha particles was successively tested using a 243Am radioactive source. Initial tests were made using the boron-deposited glass, and the electronic signal was properly read. However, when the same system was tested using the boron deposited directly in the photodiode, the output signal couldn’t be read, due to the fact that during the deposition process there was an increase in the dark current and a decrease in the operation bias. In this way, a new portable electronic system was developed using a hybrid integrated amplifier circuit. This new electronic setup allowed the use of both configurations, and was tested both with alpha-emitting Americium and neutron-emitting AmBe sources. In conclusion, both portable electronic systems have proven suitable for the thermal neutron detector developed.

  • IPEN-DOC 14141

    RAELE, MARCUS P. ; AMARAL, MARCELLO M.; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. de . Comparing methods of FD-OCT signal processing via computer simulations. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 32., 11-15 de maio, 2009, Aguas de Lindoia, SP. Resumo... 2009.

    Palavras-Chave: laser radiation; tomography; optical properties; interferometry; signals; processing; computerized simulation

  • IPEN-DOC 13507

    BENETTI, CAROLINA; GOULART, VIVIANE P.; RAELE, MARCUS P. ; FREITAS, ANDERSON Z. de ; ZEZELL, DENISE M. . Determinacao do limiar de ablacao o e coefeciente de absorcao o do osso para o laser de Er, Cr:YSGG. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 31., 5-9 de maio, 2008, Aguas de Lindoia, SP. Resumo... 2008.

    Palavras-Chave: skeleton; tibia; rabbits; sample preparation; laser radiation; erbium; chromium; surgery; tomography; optical properties

  • IPEN-DOC 15998

    RAELE, MARCUS P. ; AMARAL, MARCELLO M. ; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. de . Development of a Mueller matrix optical coherence tomography system. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 33., 10-14 de maio, 2010, Aguas de Lindoia, SP. Resumos... 2010.

    Palavras-Chave: tomography; optical properties; interferometry; matrices; polarization

  • IPEN-DOC 14142

    AMARAL, MARCELLO M.; RAELE, MARCUS P. ; SAMAD, RICARDO E. ; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. de . Development of a new methodology of roughness measurement using optical coherence tomography (OCT) according DIN 4768. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 32., 11-15 de maio, 2009, Aguas de Lindoia, SP. Resumo... 2009.

    Palavras-Chave: laser radiation; tomography; optical properties; roughness; surface properties; sample preparation; resolution; programming

  • IPEN-DOC 27949

    AMARAL, MARCELLO M.; DEL-VALLE, MATHEUS ; RAELE, MARCUS P. ; PRETTO, LUCAS R. de . Laser speckle imaging for osteoporosis evaluation. In: ENCONTRO DE OUTONO DA SOCIEDADE BRASILEIRA DE FÍSICA, 43., 23-26 de novembro, 2020, Online. Resumo... São Paulo, SP: Sociedade Brasileira de Física, 2020.

    Abstract: Osteoporosis is a common disease characterized by the reduction on Bone Mineral Density (BMD), leading to weakening of bone structure, Chronic pain, deformities and loss of quality of life. In addition to the clinical evaluation, dual-energy X-ray absorptiometry is one of the main techniques to diagnose it. However, this technique uses ionizing radiation to assess the bone structure and therefore cannot be used very often by patients, due to radiological safety reasons. On the other hand, optical techniques are known for its safe use, due to non-ionizing radiation, however, optical techniques do not easily allows the analysis of bone tissue. This limitation could be circumvented in the oral cavity area. In this work we used the Laser Speckle Imaging (LSI) technique to evaluate maxilla and mandible bones after demineralization prosses in an animal in vitro model. Osteoporosis lesions were simulated in sixteen mandible and twelve maxilla slabs using Ethylenediaminetetraacetic Acid (EDTA) 0.5 M for 0 (control) 7, 15 and 30 days. The roughness parameters Ra and Rq were analyzed with optical profilometry (ZeGage, Zygo, USA) to characterize the demineralization process. The LSI images were measured by custom experimental setup. A collimated laser beam at 635 nm and 1.3mW (Thorlabs CPS635R), expanded by a diverging lens (-75 mm), illuminates the sample. The scattered signal was imaged by a CCD camera (Thorlabs - DCC1645-HQ), an adapter (Thorlabs MVLCMC) and objective lens (Thorlabs/Navitar - MVL12X3Z) setting. A custom software was implemented to measure the speckle patches ratio and the speckle contrast ratio from speckle images obtained by a custom LSI setup. The speckle contrast ratio method only differentiate sound from osteoporotic tissue. The speckle patches ratio method presented a negative correlation with the roughness parameter, and consequently with the demineralization level. It was concluded that LSI is a promissory technique for assessment osteoporosis lesions on alveolar bone and, for that, the patches ratio is the best methodology for detecting and differentiating several degrees of demineralization.

  • IPEN-DOC 27065

    COSTA, PRISCILA ; RAELE, MARCUS P. ; YORIYAZ, HELIO ; ZAHN, GUILHERME S. ; GENEZINI, FREDERICO A. . Modelling a prototype of thermal neutron detector using a thin boron film and a photodiode. In: ENCONTRO DE FÍSICA; ENCONTRO NACIONAL DE FÍSICA DA MATÉRIA CONDENSADA, 39.; REUNIÃO DE TRABALHO SOBRE FÍSICA NUCLEAR NO BRASIL, 39.; ENCONTRO NACIONAL DE FÍSICA DE PARTÍCULAS E CAMPOS, 37.; ENCONTRO BRASILEIRO DE FÍSICA DOS PLASMAS, 13.; ENCONTRO DE PESQUISA EM ENSINO DE FÍSICA, 16., 3-7 de setembro, 2016, Natal, RN. Resumo... São Paulo, SP: Sociedade Brasileira de Física, 2016.

    Abstract: Neutron detection is an important task especially for worker protection in nuclear installations. For that purpose, it is desired to have portable and compact detectors, an aim which can be achieved using semiconductor detectors. In this work the Monte Carlo modelling of a neutron detector based on a thin boron film and photodiode is presented. The simulation was carried out using the MCNP6 code, in order to evaluate the detection efficiency for the alpha particles emitted in the boron neutron capture reaction. Two different setup subsets were modelled, taking into account the fact that the film could be deposited either in direct contact to the photodiode surface, or in indirect contact, where the film was deposited in a substrate (glass). In direct contact the thin film thickness ranged from 0 to 5 μm. For the indirect contact the thicknesses of the substrate and air region were varied. For both cases, the model was also prepared to consider the situation in which the film was sandwiched between two photodiodes in order to increase alpha particle detection efficiency. The results show that the thickness of the substrate, of 150 μm or 1000 μm, has a small influence on the alpha particle flux on the photodiode surface. The increase of the air region causes a decrease of 57 % in the flux of alpha particles in the photodiode. These different setups allowed determining the thickness values of thin boron film that delivers a higher alpha particle flux, which will lead to an optimum detection efficiency.

  • IPEN-DOC 13522

    FREITAS, ANDERSON Z. de ; RAELE, MARCUS P. ; VIEIRA JUNIOR, NILSON D. ; SANGLARD, LUCIANA F.; RODRIGUES, CELIA R.M.D.. Optical coherence tomography study of wear and tear in microabrasion enamel of primary teeth. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 31., 5-9 de maio, 2008, Aguas de Lindoia, SP. Resumo... 2008.

    Palavras-Chave: teeth; enamels; abrasives; tomography

  • IPEN-DOC 26544

    AMARAL, MARCELLO M.; PRETTO, LUCAS de ; RAELE, MARCUS P. . Optical evaluation of polymer deposition for 3D printing. In: ENCONTRO DE OUTONO DA SOCIEDADE BRASILEIRA DE FÍSICA, 42., 26-31 de maio, 2019, Aracaju, SE. Resumo... São Paulo, SP: Sociedade Brasileira de Física, 2019.

    Abstract: 3D printing is a technology that is revolutionizing the productive sector [1]. It allows the production of free- form components and systems. It may ¯nd application from biomedical to aerospace engineering, as well as in the production of unique and speci¯c components needed in basic science laboratories. One of the most common approaches for 3D printing is the fused deposition modeling were a plastic ¯lament is fused and the component shape is modeled by layers deposition [2]. The success in the manufacture of the component is related to the addition between successive deposited layers. Increasing the temperature of the ¯lament to ensure perfect adhesion may compromise the desired shape and function characteristics for the component. Scanning Electronic Microscopy (SEM) is the gold standard technique to ensure the ideal condition for the 3D printing and evaluate the bonding between successive layers [2]. However, in this context, SEM is a destructive technique and do not allow real time application. Low Coherence Interferometry (LCI) is an optical technique capable to performing non-destructive tomography evaluation of scatter medium [3]. Using a Michelson interferometer to measure the backscattered light intensity as a function of depth position associated to a lateral scanning it is possible to obtain a cross-section image of the sample [3]. It is non-invasive, relatively inexpensive technique and could allow real time application during manufacturing. The aim of this work was to investigate the use of low coherence interferometry to evaluate the adhesion of successive layers on 3D printed plastic material. A set of samples were manufactured using a 3D printing (Cliever CL1, Brazil), with layer thickness from 100¡250¹m using PLA ¯lament. The sample were evaluated using a SEM and a commercial LCI (OCP930SR - Thorlabs Inc.) and the images were compared. It was possible to observe a correlation on the observed fused ¯laments between the images acquired by SEM and LCI proving that it is possible to use the optical technique as a alternative for 3D printing quality evaluation.

  • IPEN-DOC 14140

    RAELE, MARCUS P. ; AMARAL, MARCELLO M.; VIEIRA JUNIOR, NILSON D. ; FREITAS, ANDERSON Z. de . PS-OCT birrefringence measurements. In: ENCONTRO NACIONAL DE FISICA DA MATERIA CONDENSADA, 32., 11-15 de maio, 2009, Aguas de Lindoia, SP. Resumo... 2009.

    Palavras-Chave: laser radiation; tomography; optical properties; interferometry; diagnosis; sample preparation; spectrometers; signals; programming

A pesquisa no RD utiliza os recursos de busca da maioria das bases de dados. No entanto algumas dicas podem auxiliar para obter um resultado mais pertinente.

É possível efetuar a busca de um autor ou um termo em todo o RD, por meio do Buscar no Repositório , isto é, o termo solicitado será localizado em qualquer campo do RD. No entanto esse tipo de pesquisa não é recomendada a não ser que se deseje um resultado amplo e generalizado.

A pesquisa apresentará melhor resultado selecionando um dos filtros disponíveis em Navegar

Os filtros disponíveis em Navegar tais como: Coleções, Ano de publicação, Títulos, Assuntos, Autores, Revista, Tipo de publicação são autoexplicativos. O filtro, Autores IPEN apresenta uma relação com os autores vinculados ao IPEN; o ID Autor IPEN diz respeito ao número único de identificação de cada autor constante no RD e sob o qual estão agrupados todos os seus trabalhos independente das variáveis do seu nome; Tipo de acesso diz respeito à acessibilidade do documento, isto é , sujeito as leis de direitos autorais, ID RT apresenta a relação dos relatórios técnicos, restritos para consulta das comunidades indicadas.

A opção Busca avançada utiliza os conectores da lógica boleana, é o melhor recurso para combinar chaves de busca e obter documentos relevantes à sua pesquisa, utilize os filtros apresentados na caixa de seleção para refinar o resultado de busca. Pode-se adicionar vários filtros a uma mesma busca.

Exemplo:

Buscar os artigos apresentados em um evento internacional de 2015, sobre loss of coolant, do autor Maprelian.

Autor: Maprelian

Título: loss of coolant

Tipo de publicação: Texto completo de evento

Ano de publicação: 2015

Para indexação dos documentos é utilizado o Thesaurus do INIS, especializado na área nuclear e utilizado em todos os países membros da International Atomic Energy Agency – IAEA , por esse motivo, utilize os termos de busca de assunto em inglês; isto não exclui a busca livre por palavras, apenas o resultado pode não ser tão relevante ou pertinente.

95% do RD apresenta o texto completo do documento com livre acesso, para aqueles que apresentam o significa que e o documento está sujeito as leis de direitos autorais, solicita-se nesses casos contatar a Biblioteca do IPEN, bibl@ipen.br .

Ao efetuar a busca por um autor o RD apresentará uma relação de todos os trabalhos depositados no RD. No lado direito da tela são apresentados os coautores com o número de trabalhos produzidos em conjunto bem como os assuntos abordados e os respectivos anos de publicação agrupados.

O RD disponibiliza um quadro estatístico de produtividade, onde é possível visualizar o número dos trabalhos agrupados por tipo de coleção, a medida que estão sendo depositados no RD.

Na página inicial nas referências são sinalizados todos os autores IPEN, ao clicar nesse símbolo será aberta uma nova página correspondente à aquele autor – trata-se da página do pesquisador.

Na página do pesquisador, é possível verificar, as variações do nome, a relação de todos os trabalhos com texto completo bem como um quadro resumo numérico; há links para o Currículo Lattes e o Google Acadêmico ( quando esse for informado).

ATENÇÃO!

ESTE TEXTO "AJUDA" ESTÁ SUJEITO A ATUALIZAÇÕES CONSTANTES, A MEDIDA QUE NOVAS FUNCIONALIDADES E RECURSOS DE BUSCA FOREM SENDO DESENVOLVIDOS PELAS EQUIPES DA BIBLIOTECA E DA INFORMÁTICA.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

1. Portaria IPEN-CNEN/SP nº 387, que estabeleceu os princípios que nortearam a criação do RDI, clique aqui.


2. A experiência do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP) na criação de um Repositório Digital Institucional – RDI, clique aqui.

O Repositório Digital do IPEN é um equipamento institucional de acesso aberto, criado com o objetivo de reunir, preservar, disponibilizar e conferir maior visibilidade à Produção Científica publicada pelo Instituto, desde sua criação em 1956.

Operando, inicialmente como uma base de dados referencial o Repositório foi disponibilizado na atual plataforma, em junho de 2015. No Repositório está disponível o acesso ao conteúdo digital de artigos de periódicos, eventos, nacionais e internacionais, livros, capítulos, dissertações, teses e relatórios técnicos.

A elaboração do projeto do RI do IPEN foi iniciado em novembro de 2013, colocado em operação interna em julho de 2014 e disponibilizado na Internet em junho de 2015. Utiliza o software livre Dspace, desenvolvido pelo Massachusetts Institute of Technology (MIT). Para descrição dos metadados adota o padrão Dublin Core. É compatível com o Protocolo de Arquivos Abertos (OAI) permitindo interoperabilidade com repositórios de âmbito nacional e internacional.

O gerenciamento do Repositório está a cargo da Biblioteca do IPEN. Constam neste RI, até o presente momento 20.950 itens que tanto podem ser artigos de periódicos ou de eventos nacionais e internacionais, dissertações e teses, livros, capítulo de livros e relatórios técnicos. Para participar do RI-IPEN é necessário que pelo menos um dos autores tenha vínculo acadêmico ou funcional com o Instituto. Nesta primeira etapa de funcionamento do RI, a coleta das publicações é realizada periodicamente pela equipe da Biblioteca do IPEN, extraindo os dados das bases internacionais tais como a Web of Science, Scopus, INIS, SciElo além de verificar o Currículo Lattes. O RI-IPEN apresenta também um aspecto inovador no seu funcionamento. Por meio de metadados específicos ele está vinculado ao sistema de gerenciamento das atividades do Plano Diretor anual do IPEN (SIGEPI). Com o objetivo de fornecer dados numéricos para a elaboração dos indicadores da Produção Cientifica Institucional, disponibiliza uma tabela estatística registrando em tempo real a inserção de novos itens. Foi criado um metadado que contém um número único para cada integrante da comunidade científica do IPEN. Esse metadado se transformou em um filtro que ao ser acionado apresenta todos os trabalhos de um determinado autor independente das variáveis na forma de citação do seu nome.